Solicite um orçamento
Cabos de alta temperatura

UL 3580 Silicone Motor Lead Wire, 150°C 1000V

UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.

  • Tensão: 1000 V AC
  • Temperatura: 150°C
  • Isolamento / revestimento: extruded silicone rubber
  • Seleção de tamanho: 26 AWG–500 kcmil style range; table: 26–6 AWG
  • Certificação: AWM com certificação UL; UL 758
Informações sobre o produto
Visão geral do produto

UL 3580 wire selection

UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.

The detailed size table covers 26–6 AWG. Nominal silicone thickness is 1.20 mm in the 26–10 AWG rows and 1.58 mm in the 8–6 AWG rows. Conductor stranding and finished diameter are listed with each model-size combination to help check motor terminal entries, connection boxes and protective sleeves. A separate insulation schedule explains the larger conductor groups within the style range.

For a motor connection, allow space for the finished wire rather than selecting the entry around the bare conductor size. The listed construction uses a bend radius of 10 times its finished diameter. Check the temperature near the winding exit and at the connection hardware, because the 150°C wire rating must be compatible with the rest of the assembly.

Consulte o separador Especificações para ver as tabelas de modelos e tamanhos. Explore a gama de cabos de alta temperatura for related constructions. Compare UL 3644 for a different 1 kV wall schedule and the família de fios de ligação de silicone for lower-voltage options.

Construção

Construção

O UL 1056 utiliza o sistema de condutor e isolamento indicado a seguir. O esquema mostra a sequência das camadas; selecione a construção do condutor e o revestimento previstos na especificação do tamanho necessário.

Illustrative UL 3580 single-core conductor and insulation construction cutaway
Illustrative UL 3580 construction; layer dimensions are not to scale.
UL 3580 construction layers
ComponenteDetalhes da construção
CondutorSolid or stranded copper; dimensioned examples are stranded
IsolamentoBorracha de silicone extrudida
Aplicações

Aplicações

UL 3580 is used as motor lead wire and for internal appliance or electronic equipment wiring. Route and support the lead to prevent rubbing or mechanical damage at the winding exit and terminal enclosure.

Illustrative UL 3580 insulated lead routed inside industrial equipment
Illustrative UL 3580 equipment application; shown as an installation concept.

UL 3580 replacement selection

Para pedir um fio de substituição, envie a marcação do fio existente e o esquema de ligação do equipamento. Assim, podem comparar-se o condutor, o isolamento e a disposição dos terminais.

Especificações

Especificações

UL 3580 technical data
ParâmetroEspecificação
Estilo ULUL 3580
Tensão nominal1000 V AC
Classificação de temperatura150°C
Isolamento/revestimentoextruded silicone rubber
Gama de tamanhos do condutor26 AWG–500 kcmil style range; table: 26–6 AWG
Bending radius for listed construction10 × finished OD

Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.

UL 3580 size and dimension table
Modelo e tamanho do condutorFios do condutor (n.º/mm)Nominal silicone wall (mm)Diâmetro externo nominal / tolerância (mm)
UL 3580 6 AWG259/0.2541.587.89 ±0.10
UL 3580 8 AWG161/0.2541.586.88 ±0.10
UL 3580 10 AWG105/0.2541.205.41 ±0.10
UL 3580 12 AWG65/0.2541.204.77 ±0.10
UL 3580 14 AWG41/0.2541.204.28 ±0.10
UL 3580 16 AWG26/0.2541.203.90 ±0.10
UL 3580 18 AWG34/0.181.203.62 ±0.10
UL 3580 20 AWG21/0.181.203.36 ±0.10
UL 3580 22 AWG17/0.161.203.17 ±0.10
UL 3580 24 AWG11/0.161.203.02 ±0.10
UL 3580 26 AWG7/0.161.202.89 ±0.10

Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.

UL 3580 insulation thickness by conductor size
Model and conductor groupMinimum average silicone wall (mils)Minimum point wall (mils)
UL 3580 26–9 AWG4540
UL 3580 8–2 AWG6054
UL 3580 1–4/0 AWG8072
UL 3580 250–500 kcmil9586

Seleção da construção especificada

Specify UL 3580 with AWG or kcmil, stranding, required OD and connection temperature. For a size outside the dimension table, use the insulation schedule as a starting point and request the corresponding drawing.

Padrões

Normas

TEBAOFLEX UL 3580 wire is UL-certified appliance wiring material.

UL 3580 certification and standards
ItemRequisito ou referência
CertificaçãoAWM com certificação UL
Designação do estiloUL 3580
Norma de construçãoUL 758 — Material de cablagem para aparelhos
Classificação de inflamabilidade do estiloChama horizontal

Indique o estilo UL, o tamanho do condutor e as classificações de tensão e temperatura na especificação de compra. Junte ao pedido a identificação do produto e os documentos de certificação exigidos.

Cotação elaborada por engenheiros

Solicite uma recomendação e orçamento de cabos.

Envie-nos as especificações dos serviços necessários, comprimento do cabo, capacidade mecânica, ambiente, tipo de terminação e quantidade. Nossa equipe analisará a solicitação antes de enviar um orçamento.

  • Inclua o nome do produto ou o código SKU, além do comprimento e da quantidade de cabos necessários.
  • Anexe uma especificação, desenho ou ficha técnica, quando disponíveis.

    Ao enviar este formulário, concorda que a TEBAOFLEX utilize os dados de contacto e os ficheiros fornecidos para analisar e responder ao seu pedido. Os ficheiros são utilizados na elaboração do orçamento e nos esclarecimentos técnicos relativos ao seu pedido. Consulte a nossa política de Privacidade para obter informações atuais sobre o tratamento e a retenção de dados.

    * Campos obrigatórios. Inclua os detalhes principais do cabo ou da aplicação para análise.