26/45 kV (N)TMCWOEU Railway Cable
26/45 kV (N)TMCWOEU Railway Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. In the rolling stock industry, fire safety is the absolute highest priority. In the event of an emergency, cables must not propagate flames or release toxic, blinding smoke. Send the exact size, length, installation duty and documentation requirements for a technical quotation.
26/45 kV (N)TMCWOEU Railway Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. In the rolling stock industry, fire safety is the absolute highest priority. In the event of an emergency, cables must not propagate flames or release toxic, blinding smoke. Our (N)TMCWOEU railway cable is constructed with an advanced Halogen-Free HM3 polymer sheath and has achieved top-tier global fire class certifications: To withstand constant vibrations and severe environmental hazards, the cable features a highly robust multi-layer architecture: Our railway connection cables are subjected to rigorous physical and chemical tests to ensure long-lasting performance on the tracks: TEBAOFLEX supplies the (N)TMCWOEU railway cable in various cross-sections. Below are the typical dimensions for our flexible tinned copper series: Overview: The TEBAOFLEX (N)TMCWOEU railway cable is an ultimate 26/45 kV flexible connection cable designed specifically for rolling stock and railway networks. The source record places this product in industrial cables. Before ordering, confirm the exact product variant, conductor or core arrangement, system rating, route conditions, equipment connection and required documentation against the project specification.
For low- and medium-voltage rolling stock traction wiring and cabinet motor leads, evaluate these flexible constructions: Railway Rolling Stock Connection Cable — 4GKW EN / WL1 / WL2 (for 0.6/1 kV to 3.6/6 kV 4GKW EN / WL1 / WL2 halogen-free electron-beam cross-linked coach and bogie wiring); MLFC-Type Motor Lead Wire, 3.3 kV / 6.6 kV (for 3.3 kV and 6.6 kV MLFC-type flexible motor lead wires serving traction motors and auxiliary converters). Match voltage class, thermal rating, and smoke/toxicity performance to the vehicle specification.
26/45 kV (N)TMCWOEU Railway Cable construction
Detailed Cable Construction
To withstand constant vibrations and severe environmental hazards, the cable features a highly robust multi-layer architecture:
Construction details are retained from the original product record and require project confirmation against the ordered cable schedule.
26/45 kV (N)TMCWOEU Railway Cable applications
Our (N)TMCWOEU railway cable is constructed with an advanced Halogen-Free HM3 polymer sheath and has achieved top-tier global fire class certifications: To withstand constant vibrations and severe environmental hazards, the cable features a highly robust multi-layer architecture: Our railway connection cables are subjected to rigorous physical and chemical tests to ensure long-lasting performance on the tracks: TEBAOFLEX supplies the (N)TMCWOEU railway cable in various cross-sections.
Selection checks
Confirm the equipment interface, installation method, route length, movement or flexing duty, environmental exposure, conductor or core requirements and project documentation before final selection.
26/45 kV (N)TMCWOEU Railway Cable specifications
The source-listed technical notes are retained below. Confirm the final size, tolerance, installation basis and ordered configuration before release.
Superior Fire Safety and Halogen-Free Performance
In the rolling stock industry, fire safety is the absolute highest priority. In the event of an emergency, cables must not propagate flames or release toxic, blinding smoke. Our (N)TMCWOEU railway cable is constructed with an advanced Halogen-Free HM3 polymer sheath and has achieved top-tier global fire class certifications:
- Flame Resistance: Fully complies with IEC 60332-1 and EN 50265-2-1.
- Smoke Density & Toxicity: Meets BS 6853 (Vehicle category 1b), NF F 16-101 (Class Fo), and EN 50305 (ITC < 3) standards, ensuring light transmission > 60% with zero toxic halogen gas emission.
- Fire Propagation: Tested to IEC 60332-3 Category C and NF C 32-070 Class C1.
Technical Data & Environmental Resistance
Our railway connection cables are subjected to rigorous physical and chemical tests to ensure long-lasting performance on the tracks:
Dimensions and Weight (26/45 kV Series)
TEBAOFLEX supplies the (N)TMCWOEU railway cable in various cross-sections. Below are the typical dimensions for our flexible tinned copper series:
Source-listed technical tables
The tables below retain the original product data, including units, ranges and ordering examples.
| Rated Voltage | 26/45 kV (Max Continuous: 31/54 kV) |
| Test Voltage & Impulse Peak | 87 kV (AC 5 min) / 250 kV Impulse |
| Conductor Temperature | Max. +90°C (Short circuit: +250°C) |
| Ambient Temp. (Fixed / Flexing) | -40°C to +80°C / -25°C to +80°C |
| Oil & Fuel Resistance | IRM 902 (72h@100°C) / IRM 903 (168h@70°C) |
| Mechanical Toughness | Resistant to rock-falls, hailstones, and vibrations (EN 61373 Cat 1, Class B) |
| Chemical & Weather Resistance | Ozone, UV, Saltwater, Snow, Ice, and Outdoor Cleanser resistant |
| Cross-section (mm²) | Conductor Dia. approx (mm) | Insulation Thickness (mm) | Overall Cable Dia. (mm) | DC Resistance at 20°C (Ω/km) | Weight approx. (kg/km) |
|---|---|---|---|---|---|
| 1 x 50 / 16 | 9.3 | 8.0 | 36 - 38 | 0.393 | 1 900 |
| 1 x 95 / 16 | 12.9 | 8.0 | 40 - 42 | 0.210 | 2 700 |
| 1 x 150 / 25 | 16.0 | 8.0 | 44 - 46 | 0.132 | 3 700 |
| 1 x 240 / 25 | 20.6 | 8.0 | 49 - 51 | 0.082 | 4 500 |
| 1 x 400 / 35 | 26.5 | 8.0 | 55 - 57 | 0.050 | 6 400 |
| 1 x 630 / 35 | 33.9 | 8.0 | 62 - 66 | 0.028 | 9 200 |
26/45 kV (N)TMCWOEU Railway Cable standards and compliance
The following standard references are carried over from the original product record. They identify the source basis and do not replace project-specific certification or inspection requirements.
- Flame Resistance: Fully complies with IEC 60332-1 and EN 50265-2-1.
- Smoke Density & Toxicity: Meets BS 6853 (Vehicle category 1b), NF F 16-101 (Class Fo), and EN 50305 (ITC < 3) standards, ensuring light transmission > 60% with zero toxic halogen gas emission.
- Fire Propagation: Tested to IEC 60332-3 Category C and NF C 32-070 Class C1.
- Conductor: Highly flexible tinned (or plain) copper wire, Class 5 according to DIN VDE 0295 / IEC 60228.
- Outer Sheath: Halogen-free, cross-linked polymer compound HM3 (acc. to DIN VDE 0207-24). Oil resistant, flame retardant, and colored Red.
- Mechanical Toughness Resistant to rock-falls, hailstones, and vibrations (EN 61373 Cat 1, Class B)
Where a project requires a test report, certificate, marking record or inspection release, include that requirement in the quotation request.
Request a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.