(N)TSCGECECWÖU 8.7/15kV 12/20kV TBM Reeling Cable
(N)TSCGECECWÖU 8.7/15kV 12/20kV TBM Reeling Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. Voltage drop depends on conductor size and power factor. At power factor 0.8, typical voltage drop values are 1.45V/A/km for 25mm², 1.06V/A/km for 35mm², 0.77V/A/km for 50mm², 0.56V/A/km for 70mm², 0.45V/A/km for 95mm² and 0.36V/A/km for 120mm². Send the exact size, length, installation duty and documentation requirements for a technical quotation.
(N)TSCGECECWÖU 8.7/15kV 12/20kV TBM Reeling Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. Voltage drop depends on conductor size and power factor. At power factor 0.8, typical voltage drop values are 1.45V/A/km for 25mm², 1.06V/A/km for 35mm², 0.77V/A/km for 50mm², 0.56V/A/km for 70mm², 0.45V/A/km for 95mm² and 0.36V/A/km for 120mm². Current capacity should also be corrected for ambient temperature. At 40°C the de-rating factor is 0.91; at 50°C it is 0.82; at 60°C it is 0.71; and at 80°C it is 0.41. For TBM reeling systems, cable selection should consider more than rated voltage. Buyers should check drum diameter, number of reeled layers, travel route, bending radius, torsion, ambient temperature, current load, voltage drop and available installation space. The same conductor size can carry different current depending on whether it is laid on the floor or reeled in multiple layers, so project quotations should include both the electrical load and the reeling arrangement. (N)TSCGECECWÖU Cable is a medium voltage reeling cable for tunnel boring machines and tunnel power applications. The source record places this product in mining & tunneling cables. Before ordering, confirm the exact product variant, conductor or core arrangement, system rating, route conditions, equipment connection and required documentation against the project specification.
(N)TSCGECECWÖU 8.7/15kV 12/20kV TBM Reeling Cable construction
Cable Construction
- Phase conductor: Class 5 tinned copper conductor.
- Insulation: Rubber compound for medium voltage flexible cable service.
- Semiconductive layers: Semiconductive tape over the conductor plus inner and outer semiconductive rubber layers on the insulation.
- Protective earth conductor: Individual copper wire screen.
- Control conductor: Class 5 tinned copper conductor.
- Central filler: Semiconductive compound on a textile polyester support.
- Inner sheath: Rubber compound.
- Monitoring conductor: Copper wire screen over the inner sheath.
- Outer sheath: Red rubber compound.
(N)TSCGECECWÖU 8.7/15kV 12/20kV TBM Reeling Cable applications
Applications
- Reeling drum power supply for tunnel boring machines.
- Medium voltage flexible cable routes in tunnel construction.
- Indoor and outdoor tunnel applications requiring red rubber-sheathed medium voltage cable.
- Mobile power supply where bending radius, torsional stress, tensile load and cable weight must be checked before installation.
- Project designs that require protective earth, control conductor and monitoring conductor functions in one cable construction.
Selection Notes for Buyers
For TBM reeling systems, cable selection should consider more than rated voltage. Buyers should check drum diameter, number of reeled layers, travel route, bending radius, torsion, ambient temperature, current load, voltage drop and available installation space. The same conductor size can carry different current depending on whether it is laid on the floor or reeled in multiple layers, so project quotations should include both the electrical load and the reeling arrangement.
Selection checks
Confirm the equipment interface, installation method, route length, movement or flexing duty, environmental exposure, conductor or core requirements and project documentation before final selection.
(N)TSCGECECWÖU 8.7/15kV 12/20kV TBM Reeling Cable specifications
The source-listed technical notes are retained below. Confirm the final size, tolerance, installation basis and ordered configuration before release.
Voltage Drop and De-Rating Notes
Voltage drop depends on conductor size and power factor. At power factor 0.8, typical voltage drop values are 1.45V/A/km for 25mm², 1.06V/A/km for 35mm², 0.77V/A/km for 50mm², 0.56V/A/km for 70mm², 0.45V/A/km for 95mm² and 0.36V/A/km for 120mm². Current capacity should also be corrected for ambient temperature. At 40°C the de-rating factor is 0.91; at 50°C it is 0.82; at 60°C it is 0.71; and at 80°C it is 0.41.
Source-listed technical tables
The tables below retain the original product data, including units, ranges and ordering examples.
| Product Type | Medium voltage TBM reeling drum cable |
| Type Designation | (N)TSCGECECWÖU |
| Rated Voltage Uo/U | 8.7/15kV; 12/20kV |
| Test Voltage | 24kV for 8.7/15kV; 29kV for 12/20kV |
| Ambient Temperature, Fixed | -40°C to +80°C |
| Ambient Temperature, Flexed | -25°C to +80°C |
| Minimum Bending Radius, Fixed | 6 x overall diameter |
| Minimum Bending Radius, Flexed | 10 x overall diameter |
| Maximum Torsional Stress | ±25°/m |
| Sheath Colour | Red |
| Construction | VDE 0250 Part 813 |
| Conductor Reference | VDE 0295, EN 60228 |
| Flame Retardant | IEC/EN 60332-1-2 |
| Voltage | Construction | Phase Conductor | Earth Conductor | Control Conductor | Conductor Diameter | Overall Diameter | Max Tensile Load | Nominal Weight |
|---|---|---|---|---|---|---|---|---|
| 8.7/15kV | 3+3+3+ÜL | 25mm² | 25/3E | 2.5ST | 6.8mm | 48.0 - 51.5mm | 1125N | 3590kg/km |
| 8.7/15kV | 3+3+3+ÜL | 35mm² | 25/3E | 2.5ST | 7.8mm | 49.5 - 53.1mm | 1575N | 3990kg/km |
| 8.7/15kV | 3+3+3+ÜL | 50mm² | 25/3E | 2.5ST | 9.4mm | 54.4 - 58.2mm | 2250N | 4880kg/km |
| 8.7/15kV | 3+3+3+ÜL | 70mm² | 35/3E | 2.5ST | 11.2mm | 58.2 - 62.2mm | 3150N | 5950kg/km |
| 8.7/15kV | 3+3+3+ÜL | 95mm² | 50/3E | 2.5ST | 12.7mm | 61.4 - 65.7mm | 4275N | 7030kg/km |
| 8.7/15kV | 3+3+3+ÜL | 120mm² | 70/3E | 2.5ST | 14.4mm | 67.4 - 71.9mm | 5400N | 8690kg/km |
| 12/20kV | 3+3+3+ÜL | 25mm² | 25/3E | 2.5ST | 6.8mm | 50.5 - 54.1mm | 1125N | 3860kg/km |
| 12/20kV | 3+3+3+ÜL | 35mm² | 25/3E | 2.5ST | 7.8mm | 52.3 - 56.0mm | 1575N | 4260kg/km |
| 12/20kV | 3+3+3+ÜL | 50mm² | 25/3E | 2.5ST | 9.4mm | 57.5 - 61.4mm | 2250N | 5190kg/km |
| 12/20kV | 3+3+3+ÜL | 70mm² | 35/3E | 2.5ST | 11.2mm | 61.0 - 65.3mm | 3150N | 6280kg/km |
| 12/20kV | 3+3+3+ÜL | 95mm² | 50/3E | 2.5ST | 12.7mm | 66.4 - 70.9mm | 4275N | 7640kg/km |
| 12/20kV | 3+3+3+ÜL | 120mm² | 70/3E | 2.5ST | 14.4mm | 70.5 - 75.2mm | 5400N | 9050kg/km |
| Nominal Cross Section | Laying on Floor | Reeled 1 Layer | 2 Layers | 3 Layers | 4 Layers | 5 Layers | 6 Layers | 7 Layers |
|---|---|---|---|---|---|---|---|---|
| 25mm² | 139A | 111A | 85A | 68A | 58A | 53A | 38A | 31A |
| 35mm² | 172A | 138A | 105A | 84A | 72A | 65A | 46A | 38A |
| 50mm² | 216A | 173A | 132A | 106A | 91A | 82A | 58A | 48A |
| 70mm² | 265A | 212A | 162A | 130A | 111A | 101A | 72A | 58A |
| 95mm² | 319A | 255A | 195A | 156A | 134A | 121A | 86A | 70A |
| 120mm² | 371A | 297A | 226A | 182A | 156A | 141A | 100A | 82A |
Original product attributes
These product attributes are retained as supplied and should be checked against the ordered construction.
| Product Type | Medium voltage TBM reeling drum cable |
|---|---|
| Model | (N)TSCGECECWÖU |
| Voltage Rating | 8.7/15kV; 12/20kV |
| Test Voltage | 24kV for 8.7/15kV; 29kV for 12/20kV |
| Conductor | Class 5 tinned copper conductor |
| Insulation | Rubber compound with semiconductive layers |
| Protective Earth | Individual copper wire screen |
| Monitoring Conductor | Copper wire screen over inner sheath |
| Outer Sheath | Red rubber compound |
| Fixed Temperature | -40°C to +80°C |
| Flexed Temperature | -25°C to +80°C |
| Flexed Bending Radius | 10 x overall diameter |
| Maximum Torsional Stress | ±25°/m |
| Flame Retardant | IEC/EN 60332-1-2 |
(N)TSCGECECWÖU 8.7/15kV 12/20kV TBM Reeling Cable standards and compliance
The following standard references are carried over from the original product record. They identify the source basis and do not replace project-specific certification or inspection requirements.
- Construction VDE 0250 Part 813
- Conductor Reference VDE 0295, EN 60228
- Flame Retardant IEC/EN 60332-1-2
Where a project requires a test report, certificate, marking record or inspection release, include that requirement in the quotation request.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
NSHCGEÖU KON+ST+UL 0.6/1 kV Monitored Tunnel Cable
A related cable option for a different application or duty profile.