NEK 606 P108 UX Earth Cable for Offshore Earthing and Bonding
The NEK 606 P108 UX earth cable is a single-core green/yellow 0.6/1 kV cable for fixed protective-earthing and equipotential-bonding routes on offshore oil and gas installations. The construction combines a Class 2 stranded tinned copper conductor with an SHF2 H-M halogen-free covering. It is intended for projects that specify the P108 UX designation rather than a general industrial green/yellow conductor.
Use the Construction, Applications, Specifications and Standards tabs to review the supplied materials, use boundaries, nominal size data and test references.
Quick Suitability Check
- Suitable for: fixed earthing and bonding connections on offshore platforms, drilling units and associated marine oil and gas equipment where P108 UX is specified.
- Confirm before use: protective-conductor size, prospective fault current, protection clearing time, route exposure, terminal type, bend radius and required NEK 606 edition.
- Not intended as specified: phase or neutral identification, continuous reeling, trailing, festoon, repeated-flex or submerged service.
Selection Notes for Offshore Projects
Size the bonding conductor for the fault duty
Continuous current capacity is only one input. Protective-earthing and bonding conductors must be checked against the project earthing design, prospective fault current, protective-device clearing time, permitted conductor temperature and applicable installation rules. The supplied one-second short-circuit values provide a reference, but the project engineer must confirm the final size and protection coordination.
Check the complete route exposure
P108 UX is selected for offshore routes where salt-laden air, hydrocarbons, mineral or hydraulic oils and drilling fluids or muds may be relevant. State the actual chemicals, concentration, temperature, exposure duration and cleaning regime in the RFQ. A general mud- or oil-resistance reference should not be treated as universal chemical compatibility.
Coordinate lugs, glands and mechanical support
Use the nominal diameter and weight table to plan cleats, supports, entry seals and handling. Confirm the final manufactured diameter before ordering compression lugs, glands or transit components. The minimum bend value is 4 × cable OD for fixed installation; repeated bending requires a different moving-duty assessment.
Related Offshore Cable Selection
Browse the Marine & Offshore Cables range or the related Oil & Gas Cables range. For project schedules requiring a different NEK 606 power or control construction, review the 0.6/1 kV RFOU marine and offshore cable and the 5G 35 mm² RFOU cable. These are related project options, not direct replacements for a P108 UX earth cable.
Information Needed for Quotation
- Required designation and project NEK 606 edition
- Conductor cross-sectional area and total cable length
- Prospective earth-fault current and protection clearing time
- Installation area, route, support spacing and minimum bend diameter
- Salt, UV, oil, hydrocarbon, drilling-fluid and mud exposure details
- Lug, gland, transit, marking, packing and drum requirements
- Required test reports, third-party inspection or classification documents
Request a technical quotation with the cable schedule, route conditions and required documentation.
Why Work With TEBAOFLEX
TEBAOFLEX can review the requested conductor size, length, marking, packing and documentation package before quotation. Jiangsu Tebaoflex Special Cable Co., Ltd. holds ISO 9001, ISO 14001 and ISO 45001 management-system certificates within their stated company scopes. These credentials support company management systems and do not replace an exact-model NEK 606 product approval or project classification certificate.
FAQ
What is NEK 606 P108 UX earth cable used for?
It is used as a fixed single-core protective-earthing and equipotential-bonding cable on offshore oil and gas installations where the project specifies the P108 UX construction.
Can P108 UX cable be used as a phase or neutral conductor?
The supplied cable is identified green/yellow for earthing and bonding duty. It should not be reassigned as a phase or neutral conductor.
What sizes are available in the supplied range?
The supplied table covers one-core constructions from 6 to 400 mm². Final dimensions and availability should be confirmed with the quotation.
What is the operating temperature?
The supplied maximum conductor operating temperature is +90°C. No minimum installation or operating temperature was supplied, so the lower limit must be confirmed for the project.
Is this TEBAOFLEX P108 UX cable DNV, Lloyd’s Register or ABS approved?
No exact-model TEBAOFLEX approval scope was supplied for those classification societies. If class approval is mandatory, state the required society and certificate in the RFQ so the documentation can be confirmed before order.
What information is needed to select the conductor size?
Provide the earthing-system design, prospective fault current, protection clearing time, cable route, ambient conditions, required length, termination method and applicable project standard.