MINING & TUNNELING CABLES TEBAOFLEX

2YSLGCGOEU 250/250 V Signal and Control Cable

250/250 V screened signal, control and bus cable with paired cores, PE insulation and tinned copper braid screen.

Product information
Brand
TEBAOFLEX
Product overview

2YSLGCGOEU is a screened signal, control and bus cable for open-cast mining, conveyor systems, material handling and automation circuits. The supplied VDE sheet specifies paired cores, flexible stranded copper conductors, PE type 2YI1 insulation, EM2 inner and outer sheaths and a tinned copper braid screen. It names VDE 0250 Part 812 and DIN VDE 0295 and provides size data for 2 × 2 × 1, 5 × 2 × 1, 10 × 2 × 1 and 20 × 2 × 1 arrangements. Voltage, test, thermal and mechanical fields were added after the authorized cross-check of three public technical references for the same designation: 250/250 V rated voltage, 350 V peak maximum AC and DC operating voltage, 1.5 kV test voltage, 60 °C maximum conductor temperature, 150 °C short-circuit temperature, fixed service from −40 °C to +60 °C and fully flexible service from −25 °C to +60 °C. The reference set also identifies a 15 N/mm² tensile value and ±25°/m torsion value. Confirm the pair count, protocol or control function, route, movement duty, screening termination, marking, length and required test documents with TEBAOFLEX before quotation.

Construction

2YSLGCGOEU paired-core construction

2YSLGCGOEU is arranged as paired cores in layers with a continuous non-hygroscopic serving over the conductor assembly. The supplied drawing identifies flexible Class 5 copper conductors, PE type 2YI1 insulation, EM2 inner and outer sheaths and a tinned copper wire braid screen.

2YSLGCGOEU cable cross-section showing paired cores, PE insulation, copper braid screen and EM2 sheaths
Supplied 2YSLGCGOEU cross-section showing the paired-core screened signal and control construction.
Construction identified in the supplied VDE datasheet
ParameterSource-listed value
ConductorsFlexible stranded copper conductor, Class 5 according to DIN VDE 0295
InsulationPE insulation type 2YI1
Cable elementCores laid up in pairs in layers with continuous non-hygroscopic serving
Inner sheathCM type EM2
ScreenTinned copper wire braid
Outer sheathCM type EM2

The paired layout and braid screen are the key selection points for process-data, automation and bus applications. Confirm the transmission requirement and final pair count rather than treating every control cable as a bus cable.

Applications

Applications for 2YSLGCGOEU

The supplied application identifies control, signalling and bus connections for electric and electronic equipment, measured-value processing, process-data systems and automation units in open-cast mining. It is suitable for laying alongside conveyor belts and on material-handling equipment.

2YSLGCGOEU signal and control cable application alongside an open-cast mining conveyor system
Existing Media Library application image illustrating a mining conveyor and material-handling route; confirm the required pair count, transmission function and installation mode for 2YSLGCGOEU.
  • Open-cast mining control, signalling and bus circuits
  • Measured-value processing, process-data systems and automation units
  • Routes alongside conveyor belts and on material-handling equipment
  • Fixed or fully flexible installation within the cross-checked temperature and mechanical reference window
  • Confirm pair count, protocol/transmission requirement, route, movement, screening termination and final marking before quotation

The 250/250 V rating is a signal/control-circuit reference, not a substitute for the equipment interface or communication-system specification. Include the required pair arrangement and cable length in the RFQ.

Specifications

2YSLGCGOEU specifications

The supplied VDE sheet provides the construction and size table. Voltage, test, thermal and mechanical fields below were cross-checked on 2026-08-30 against three public technical references for the same 2YSLGCGOEU designation, as authorized for this upload. Confirm the final cable marking and project documentation before order release.

2YSLGCGOEU voltage, temperature and mechanical reference fields
ParameterSource-listed value
Rated voltage U₀/U250/250 V
Maximum permissible AC operating voltage350 V peak value
Maximum permissible DC operating voltage350 V peak value
AC test voltage1.5 kV
Maximum conductor operating temperature60 °C
Maximum short-circuit conductor temperature150 °C
Fixed ambient temperature−40 °C to +60 °C
Fully flexible ambient temperature−25 °C to +60 °C
Maximum tensile load15 N/mm²
Maximum torsional stress±25°/m
Minimum bending radiusAccording to DIN VDE 0298 Part 3; public references also list 4 × Ø fixed and 5 × Ø moving
2YSLGCGOEU size and weight data
Number of cores × nominal cross-sectionMinimum OD (mm)Maximum OD (mm)Nominal weight (kg/km)
2 × 2 × 111.013.0245
5 × 2 × 116.019.0440
10 × 2 × 120.023.0700
20 × 2 × 125.029.01040

Standard values are based on the supplied technical data table. Other packing forms and delivery lengths are available on request.

Standards

2YSLGCGOEU standards and cross-checked reference fields

The supplied VDE sheet names VDE 0250 Part 812 and DIN VDE 0295. The voltage, temperature and mechanical fields are included after the authorized three-source public cross-check for this designation.

Standards, tests and approvals referenced for this product
ParameterSource-listed value
Cable standardVDE 0250 Part 812
Conductor standardDIN VDE 0295
Rated voltage250/250 V
AC test voltage1.5 kV
Fixed ambient temperature−40 °C to +60 °C
Fully flexible ambient temperature−25 °C to +60 °C
Flame referenceVDE 0482-332-1-2 / IEC 60332-1-2 — public technical reference cross-check
Oil referenceEN 60811-404 — public technical reference cross-check

For quotation, provide the intended pair/core configuration, bus or control function, route, fixed/moving duty and required test documentation. Public reference values do not replace the final TEBAOFLEX order drawing.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    Optional: attach a cable specification, drawing, data sheet or product image (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG or PNG; maximum 10 MB).

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.