UL 3644 Silicone Appliance Wire, 200°C 1000V
UL 3644 is a UL-certified silicone appliance wire rated 1000 V AC, with 150°C and 200°C constructions. It is intended for internal appliance wiring where the wire is totally enclosed, and the required temperature grade should appear on the equipment specification.
- Voltage: 1000 V AC
- Temperature: 150°C or 200°C by construction
- Insulation / covering: extruded silicone rubber
- Size selection: 30 AWG–1000 kcmil style range; table: 30 AWG–4/0 AWG
- Certification: UL-certified AWM; UL 758
UL 3644 wire selection
UL 3644 is a UL-certified silicone appliance wire rated 1000 V AC, with 150°C and 200°C constructions. It is intended for internal appliance wiring where the wire is totally enclosed, and the required temperature grade should appear on the equipment specification.
The dimension table now includes 19 conductor sizes from 30 AWG through 4/0 AWG. The nominal insulation wall changes with conductor size, starting at 0.82 mm for the 30–10 AWG rows. Stranding and finished diameter are shown together, while a separate style thickness schedule covers the wider range up to 1000 kcmil. This separates a finished-wire dimension from the minimum insulation requirement used to define the construction.
When replacing an enclosed appliance lead, check the temperature grade and the available bend space before assuming that another 1 kV silicone wire will fit. The listed constructions use a bend radius of 10 times finished diameter. A different wall schedule can change the terminal entry clearance even when the AWG and voltage rating match.
See the Specifications tab for the model and size tables. Browse the high-temperature cable range for related constructions. Compare UL 3580 for 150°C motor lead duty and UL 3645 when an additional outer covering is specified.
Construction
UL 3644 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

| Component | Construction detail |
|---|---|
| Conductor | Solid or stranded copper; dimensioned examples are stranded |
| Insulation | Extruded silicone rubber |
Applications
UL 3644 is intended for appliance internal wiring inside a complete enclosure. Select the 150°C or 200°C construction to match the local thermal duty and connection materials.

UL 3644 replacement selection
For replacement enquiries, include the existing wire marking and the equipment connection drawing so the conductor, insulation and terminal arrangement can be matched.
Specifications
| Parameter | Specification |
|---|---|
| UL style | UL 3644 |
| Voltage rating | 1000 V AC |
| Temperature rating | 150°C or 200°C by construction |
| Insulation / covering | extruded silicone rubber |
| Conductor size coverage | 30 AWG–1000 kcmil style range; table: 30 AWG–4/0 AWG |
| Bending radius for listed construction | 10 × finished OD |
Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.
| Model and conductor size | Stranding (No./mm) | Nominal silicone wall (mm) | Nominal OD / tolerance (mm) |
|---|---|---|---|
| UL 3644 4/0 AWG | 2146/0.254 | 2.09 | 17.77 ±0.15 |
| UL 3644 3/0 AWG | 1615/0.254 | 2.09 | 15.97 ±0.15 |
| UL 3644 2/0 AWG | 1330/0.254 | 2.09 | 14.88 ±0.15 |
| UL 3644 1/0 AWG | 1026/0.254 | 2.09 | 13.58 ±0.15 |
| UL 3644 2 AWG | 665/0.254 | 1.58 | 10.73 ±0.15 |
| UL 3644 4 AWG | 420/0.254 | 1.58 | 9.18 ±0.15 |
| UL 3644 6 AWG | 259/0.254 | 1.58 | 7.89 ±0.15 |
| UL 3644 8 AWG | 161/0.254 | 1.20 | 6.88 ±0.15 |
| UL 3644 10 AWG | 105/0.254 | 0.82 | 4.65 ±0.15 |
| UL 3644 12 AWG | 65/0.254 | 0.82 | 4.01 ±0.15 |
| UL 3644 14 AWG | 41/0.254 | 0.82 | 3.52 ±0.15 |
| UL 3644 16 AWG | 26/0.254 | 0.82 | 3.14 ±0.15 |
| UL 3644 18 AWG | 34/0.18 | 0.82 | 2.86 ±0.15 |
| UL 3644 20 AWG | 21/0.18 | 0.82 | 2.60 ±0.15 |
| UL 3644 22 AWG | 17/0.16 | 0.82 | 2.41 ±0.15 |
| UL 3644 24 AWG | 11/0.16 | 0.82 | 2.26 ±0.15 |
| UL 3644 26 AWG | 7/0.16 | 0.82 | 2.13 ±0.15 |
| UL 3644 28 AWG | 7/0.127 | 0.82 | 2.03 ±0.15 |
| UL 3644 30 AWG | 7/0.10 | 0.82 | 1.95 ±0.15 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average silicone wall (mils) | Minimum point wall (mils) |
|---|---|---|
| UL 3644 30–9 AWG | 30 | 27 |
| UL 3644 8 AWG | 45 | 40 |
| UL 3644 7–2 AWG | 60 | 54 |
| UL 3644 1–4/0 AWG | 80 | 72 |
| UL 3644 250–500 kcmil | 95 | 85 |
| UL 3644 501–1000 kcmil | 110 | 99 |
Selecting the specified construction
Identify UL 3644, conductor size and 150°C or 200°C grade together. Use the selected row for nominal OD and the appropriate thickness group for construction review.
Standards
TEBAOFLEX UL 3644 wire is UL-certified appliance wiring material.
| Item | Requirement or reference |
|---|---|
| Certification | UL-certified AWM |
| Style designation | UL 3644 |
| Construction standard | UL 758 — Appliance Wiring Material |
| Style flame classification | Horizontal flame |
Identify the UL style, conductor size, voltage and temperature grade on the purchasing specification. Include the required product identification and certification documents with the enquiry.
Request a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.