Thermo-Trex 2800 RTD Cable 41250 Alternative — TEBAOFLEX Specification Review
Searching for Thermo-Trex 2800 RTD cable 41250? This TEBAOFLEX specification-review page captures the original three-conductor 18 AWG high-temperature RTD reference so a cable engineer can compare a proposed construction against the correct instrument lead rather than a single-core Thermo-Trex 2800 power cable. The listed 530°C and 600 V values are original Amphenol TPC data, not confirmed TEBAOFLEX ratings.
- Original 41250 configuration: 18 AWG × 3 in a red/red/white triplet.
- Source conductor system: finely stranded nickel-plated copper with mica/glass insulation.
- Source screen: nickel-plated copper braid, drain wire and tape wrap.
- Source outer layer: woven, impregnated glass braid rather than a smooth polymer jacket.
- Confirm the exact hot-zone length, bending duty, shield termination and abrasion protection before quoting.
Share the installed cable marking, sensor and terminal drawing, temperature map, desired length and certification needs.
Review the 41250 RTD signal route separately from heater and power cable
Thermo-Trex 2800 RTD 41250 is an original Amphenol TPC reference for an 18 AWG, three-conductor instrument cable. The manufacturer specifies a triplet for resistance-temperature-detector control and a mica/glass construction for severe heat. A buyer looking for an alternative needs the actual temperature along the cable, conductor-count and color-code requirements, shield/earth termination, bend duty and cable-entry fit. This TEBAOFLEX page collects the original-model facts for an engineering enquiry; it does not state that an untested TEBAOFLEX cable has the original 530°C or 600 V ratings.
The Specifications tab uses the original manufacturer’s published product page and datasheet as reference sources. The 530°C figure is the maximum conductor temperature in that reference; the allowable temperature of the sensor termination, conduit, gland or moving section can be lower. The manufacturer’s parallel Thermo-Trex 2800 power/control range is a different product and its sizes should not be imported into this RTD enquiry.
- Identify the RTD circuit: confirm three-wire sensor wiring, red/red/white assignment and instrument input.
- Map the route: distinguish a static hot zone from any flexing or cold-entry transition.
- Define the screen: specify how the braid and drain wire are bonded.
- Require a matched drawing: the finished OD, braid, wall and thermal tests must belong to the offered TEBAOFLEX construction.
For unshielded high-temperature leads rather than a three-core RTD signal cable, compare the MGT mica-glass lead wire.
Construction
Amphenol TPC's original 41250 reference describes three nickel-plated copper conductors in a triplet with a red/red/white code. The cores use mica tape and glass-fiber insulation; a nickel-plated copper braid with a flat drain wire and tape wrap surrounds the cable. The outer surface is a woven glass-fiber braid impregnated with a high-temperature finish. This layered, textile-covered construction differs materially from a fluoropolymer-jacketed RTD cable. A TEBAOFLEX design must be checked against its own cross-section and materials before these details become product commitments.
| Original reference element | Reason to confirm |
|---|---|
| 18 AWG, 16/30 nickel-plated copper, three-core triplet | Sensor lead resistance and termination fit |
| Mica/glass-fiber core insulation | Layer integrity at the specified high-temperature route |
| 90% nickel-plated copper braid, 20 AWG drain in online table | Instrument-noise screening and earth termination |
| Black woven glass-braid outer covering | Abrasion protection and handling of a textile surface |

Applications
The original Thermo-Trex 2800 RTD reference is for high-temperature resistance-temperature-detector control and instrumentation, particularly where a three-conductor signal lead must cross a severe thermal route. Identify the thermal profile of each segment: a hot stationary section, transition through a gland, and any section expected to move can have different limits. A nominal maximum conductor temperature is not the rated temperature of every connected component.
- Use a three-wire RTD circuit only where the probe and input instrument are wired for that configuration.
- Specify the hot-zone distance, continuous versus intermittent exposure and any flame, chemical or abrasion exposure separately.
- Check the shield and drain termination against the instrument manufacturer's guidance.
- Keep the reference bend radius and cable entry dimensions in the design review; glass-braid surfaces need appropriate handling and protection.

Specifications
The following is original Amphenol TPC part 41250 reference data taken from its current public product page and PDF; the local directory provides imagery only. It supports a precise RFQ target but is not a TEBAOFLEX test sheet.
| Original model + configuration | Nominal OD | Nominal weight | Original source conductor / drain |
|---|---|---|---|
| Thermo-Trex 2800 RTD 41250 — 18 AWG × 3 triplet, 600 V, 530°C max conductor | 0.350 in (8.89 mm) | 96 lb / 1,000 ft | 16/30 conductor; 20 AWG drain |
Original-family rating and geometry data
| Original reference property | Source value |
|---|---|
| Nominal voltage | 600 V |
| Maximum conductor temperature | 530°C (manufacturer also prints 1000°F; not an exact conversion) |
| Cold-temperature rating | −65°C |
| Original core colors | Red / red / white |
| Nominal insulation thickness | 0.025 in, manufacturer's current online table |
| Nominal jacket thickness | 0.015 in, manufacturer's current online table |
| Overall braid coverage | 90%, original manufacturer statement |
| Minimum bend radius, static | 6 × finished cable OD |
| Minimum bend radius, dynamic | 8 × finished cable OD |
Standards
The original manufacturer's public 41250 data states a 600 V nominal rating and maximum conductor temperature of 530°C. Those ratings are a comparison target. A TEBAOFLEX quotation should identify the electrical test method, material and thermal validation for the actual offered cable, together with any project-specific documentation.
| Evidence item | Original reference | Evidence to request for quoted construction |
|---|---|---|
| Original part identity | TPC 41250 product page and specification PDF | TEBAOFLEX drawing with own model and section |
| 600 V electrical rating | Original product page and PDF | Applicable test procedure and result |
| 530°C maximum conductor temperature | Original product page and PDF | Temperature-duration basis and finished-cable scope |
| Project declarations or approvals | Buyer to specify applicable market requirements | Declarations or approvals covering the offered cable where required |
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
MGT Cable — Mica-Glass High Temperature Lead Wire 450°C / 538°C
A related cable option for a different application or duty profile.
View productUL 5390 Mica-Glass Wire, 550°C 300V
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.