High Temperature Cables TEBAOFLEX

FEP, PFA & PTFE Thermocouple Wire & Screened Multi-Pair Cable (K, J, T, E, N)

FEP (+200 °C), PFA (+260 °C) and sintered PTFE (+260 °C) thermocouple duplex wires and screened multi-pair KX, JX, TX, EX and NX extension cables (TF-FLUORO-TC-KXJX) use genuine calibrated thermocouple alloys per IEC 60584-1/3 and ANSI/ASTM E230 (Class 1 / Special Limits of Error). Available in 24–16 AWG duplex pairs and 1×2 to 24×2 x 0.5–1.5 mm² copper-braided trunk cables on 305 m / 300 m factory reels.

Product information
SKU
TF-FLUORO-TC-KXJX
Brand
TEBAOFLEX
Product overview

FEP, PFA and sintered PTFE thermocouple wires and screened multi-pair KX, JX, TX, EX and NX extension cables eliminate moisture-induced EMF drift and chemical jacket degradation across -90 °C to +260 °C, spanning 1.4 x 2.4 mm compact 24 AWG duplex autoclave sensor leads up to 24x2x1.5 mm² copper-braided petrochemical marshalling trunks.

Conventional fibreglass or ceramic braided thermocouple leads wick ambient humidity, steam and acid condensate, creating parasitic galvanic cells that corrupt millivolt cold-junction readings; PVC thermocouple cables melt above +105 °C. Non-hygroscopic fluoropolymer walls (< 0.01 % water absorption) seal calibrated NiCr-NiAl, Fe-CuNi, Cu-CuNi, NiCr-CuNi and NiCrSi-NiSi conductors against autoclave steam, hydrofluoric/sulfuric fumes, hydraulic fluids and cryogenic LNG cold traps. Matched thermoelectric alloy billets and inline laser eccentricity control keep Seebeck EMF uniform from cold junction to hot tip across 300 m continuous runs.

Specify melt-extruded FEP (+200 °C) or PFA (+260 °C) for continuous pinhole-free pharmaceutical validation, semiconductor furnaces and chemical reactors, or specify fused PTFE (+260 °C) where hot-surface contact could soften thermoplastics. Choose IEC 60584-3 or ANSI MC96.1 colour coding in Class 1 / SLE tolerance (MOQ 305 m / 300 m per item, 7 to 45 working days).

Explore the high-temperature wire and cable range for related configurations.

Construction

FEP, PFA & PTFE Thermocouple Wire & KX Cable Construction

TEBAOFLEX draws and pairs matched EMF thermocouple alloy lots from the same melt heat to prevent inhomogeneous Seebeck voltage errors along long runs.

Clean 2D engineering cross-section of 2-pair screened FEP Type KX thermocouple cable showing green outer jacket, copper braid screen, PTFE binder tape and 4 green/white cores
KX-FEP-C-FEP cross-section: matched positive/negative thermocouple alloy pairs, fluoropolymer insulation, 85 % copper braid and chemical-proof FEP sheath.
FEP, PFA & PTFE Thermocouple Wire & Screened Multi-Pair Cable (K, J, T, E, N) construction
ComponentMaterial and construction
1. Calibrated Thermocouple / Extension Alloy ConductorsSolid (24–14 AWG / 0.5–1.5 mm²) or 7-strand flexible matched alloy pairs: Type K/KX (+NiCr / -NiAl), Type J/JX (+Fe / -CuNi), Type T/TX (+Cu / -CuNi), Type E/EX (+NiCr / -CuNi) and Type N/NX (+NiCrSi / -NiSi).
2. Fluoropolymer Core Insulation (IEC 60584-3 or ANSI MC96.1)Melt-extruded FEP (+200 °C), melt-extruded PFA (+260 °C) or lapped sintered PTFE (+260 °C) polarity-coded insulation over each positive and negative leg.
3. Pair Twisting & EMC Screening (TWSH & Multi-Pair Builds)Short-lay twisted pairs to cancel magnetic 50/60 Hz pickup, wrapped in PTFE binder tape with >= 85 % tinned/silver-plated copper braid (FEP/C/FEP) or individual + overall Al/PET foil + drain wire screens.
4. Fluoropolymer Calibration-Coded Outer JacketExtruded FEP or PFA outer sheath (or fused PTFE tape wrap) colour-coded to IEC 60584-3 (green Type K, black Type J, brown Type T) or ANSI MC96.1.

FEP, PFA & KX Thermocouple Code Breakdown

  • K / J / T / E / N: Sensor-grade calibrated thermocouple alloy pairs per IEC 60584-1 / ASTM E230
  • KX / JX / TX / EX / NX: Matching-alloy extension cables for multi-pair field-to-DCS marshalling
  • FEP / PFA / PTFE: Fluoropolymer insulation grade: FEP (+200 °C), melt-extruded PFA (+260 °C) or fused PTFE (+260 °C)
  • C / TWSH: Twisted pair with >= 85 % tinned or silver-plated copper EMC braid screen
  • Class 1 / SLE: Tightest standard thermoelectric EMF tolerance band (+/-1.5 °C on Type K, +/-0.5 °C on Type T)
Applications

FEP & PFA Autoclave, Semiconductor & Refinery Applications

Built for precision millivolt temperature measurement in wet, corrosive, cleanroom, vacuum or high-ambient industrial zones.

Green FEP screened multi-pair thermocouple extension cables routed along a stainless stanchion into a junction box beside a chemical reactor
Multi-pair fluoropolymer thermocouple extension trunks terminating at a field junction box on a high-temperature chemical reactor.
  • Pharmaceutical steam-sterilization autoclaves, lyophilizer freeze-dryers (-85 °C to +140 °C SIP) and FDA/GMP validation harnesses (Type T & Type K PFA/FEP).
  • Composite aerospace autoclave curing bags, semiconductor diffusion/CVD furnaces and vacuum heat-treat chambers.
  • Refinery hydrotreater skin-point harnesses, sulfuric/hydrochloric acid reactors and hydrometallurgical autoclave multi-pair marshalling trunks.
  • Glass annealing lehrs, plastics injection hot-runner manifolds, battery cell formation ovens and cryogenic LNG storage instrumentation.

FEP vs PFA vs Sintered PTFE vs Fibreglass Thermocouple Wire

FEP (+200 °C) vs PFA (+260 °C) vs Sintered PTFE (+260 °C) vs Fibreglass (+480 °C) Thermocouple Wire
Insulation SystemContinuous Temp.Steam / Acid Moisture SealPrimary Engineering Use
Extruded FEP (this page)-90 °C to +200 °C100 % pinhole-free melt-extruded barrierAutoclave SIP validation, chemical trays & multi-pair KX/TX trunks
Extruded PFA (this page)-90 °C to +260 °CHighest continuous 260 °C melt-extruded puritySemiconductor furnaces, 260 °C acid reactors & long splice-free runs
Sintered PTFE Tape (this page)-190 °C to +260 °CNon-melting fused fluoropolymer wallComposite aerospace curing bags & hot clamping platens
Fibreglass Braid (GL/GL)Up to +480 °C dryPorous weave (absorbs moisture/condensate)Dry steel heat-treat kilns above +260 °C only

Never use porous fibreglass thermocouple wire in steam autoclaves or wet acid zones; moisture wicking shorts EMF polarity.

FEP, PFA & KX Multi-Pair Thermocouple RFQ Checklist

  • Thermocouple calibration letter (Type K/KX, J/JX, T/TX, E/EX or N/NX) and tolerance class (IEC 60584 Class 1 / ASTM SLE or Class 2).
  • Colour code standard required by plant instrumentation (IEC 60584-3 international or ANSI MC96.1 North American).
  • Construction format: duplex wire (24–16 AWG, solid or 7-strand) or multi-pair cable (1x2 to 24x2 x 0.5 / 1.0 / 1.5 mm², overall or individual+overall screen).
  • Fluoropolymer grade (FEP 200 °C, PFA 260 °C or fused PTFE 260 °C) and reel put-up (MOQ 305 m / 300 m, 7 to 45 working days).

Related selection resources

FEP, PFA & PTFE Thermocouple Cable FAQ

Why use PFA or FEP thermocouple wire instead of fibreglass in steam autoclaves?

Under 0.01 % water absorption and pinhole-free melt extrusion keep PFA (+260 °C) and FEP (+200 °C) hermetically sealed under pressurized saturated steam, whereas woven fibreglass wicks condensate that creates false galvanic junctions and fails FDA/GMP thermal mapping.

What is the difference between FEP/PFA thermocouple wire and KX extension cable?

Calibration temperature span separates them: thermocouple-grade wire (K, J, T, E, N) is EMF-calibrated across the full sensor span (for example 0 °C to +260 °C on PFA), while extension-grade multi-pair cable (KX, JX, TX, EX, NX) uses matching alloy compositions calibrated across the ambient marshalling span (-25 °C to +200 °C per IEC 60584-3).

Can TEBAOFLEX supply FEP/PFA and KX thermocouple cables in both IEC 60584-3 and ANSI MC96.1 colours?

Yes — specify IEC 60584-3 (for example Type K/KX green positive, white negative, green jacket) or ANSI MC96.1 (Type K yellow positive, red negative, brown/yellow jacket) on your RFQ; never mix ANSI and IEC polarity colours on the same loop.

Which FEP/PFA thermocouple calibration gives the highest accuracy for pharma validation?

Type T (Cu-CuNi) in IEC 60584 Class 1 / ASTM SLE achieves +/-0.5 °C tolerance (twice as tight as Type K's +/-1.5 °C), making PFA- or FEP-insulated 24 AWG Type T the benchmark for lyophilizers and steam autoclaves.

What is the MOQ and lead time for FEP, PFA & KX thermocouple cables?

305 m (1,000 ft) or 300 m per calibration and cross-section is our standard factory MOQ for both duplex thermocouple wires and screened multi-pair KX/JX/TX/EX/NX cables, with a 7 to 45 working days manufacturing lead time.

Specifications

FEP, PFA & PTFE Duplex & KX Multi-Pair Schedules

KX & Thermocouple Tolerance, Temperature & Reel Summary

  • Genuine K, J, T, E & N alloys: Calibrated NiCr-NiAl (K/KX), Fe-CuNi (J/JX), Cu-CuNi (T/TX), NiCr-CuNi (E/EX) and NiCrSi-NiSi (N/NX) conductors to IEC 60584 Class 1 / ASTM E230 SLE
  • FEP 200 °C, PFA 260 °C & PTFE 260 °C: Melt-extruded FEP (-90 to +200 °C), continuous high-purity PFA (-90 to +260 °C) or fused sintered PTFE tape (-190 to +260 °C) moisture-proof insulation
  • Duplex & multi-pair EMC trunks: Parallel oval or twisted-shielded duplex sensor leads (24–16 AWG) plus 1 to 24 pair individual/overall screened FEP/C/FEP marshalling cables
  • IEC 60584-3 or ANSI colour code: Supplied in IEC 60584-3 colour coding (green KX, black JX, brown TX, violet EX, pink NX) or North American ANSI MC96.1 (yellow/red/brown Type K)
  • Standard factory spool & reel MOQ: Supplied in 305 m (1,000 ft) or 300 m continuous calibrated spools/reels per calibration and size in 7 to 45 working days
FEP, PFA & PTFE Thermocouple Wire & Screened Multi-Pair Cable (K, J, T, E, N) technical data
ParameterValue
Rated voltage300 V / 500 V instrumentation insulation system (2000 V AC dielectric test) engineered for low-level millivolt thermoelectric EMF circuits
Thermocouple calibrations and tolerancesTypes K/KX, J/JX, T/TX, E/EX and N/NX calibrated to IEC 60584-1 Class 1 (for example +/-1.5 C on Type K, +/-0.5 C on Type T) and ASTM E230 SLE
Fluoropolymer insulation optionsMelt-extruded FEP (-90 C to +200 C), melt-extruded PFA (-90 C to +260 C continuous) or fused sintered PTFE (-190 C to +260 C)
Formats and pair countsParallel oval or twisted-shielded duplex wire (24 AWG to 16 AWG) and screened multi-pair cables (1x2, 2x2, 4x2, 8x2, 12x2, 16x2, 24x2 x 0.5 to 1.5 mm2)
Standard put-up and lead time305 m (1000 ft) or 300 m minimum order calibrated factory spools and reels delivered in 7 to 45 working days
Colour coding standardsIEC 60584-3 international colour code or ANSI/ASTM MC96.1 North American colour code (specify at RFQ stage)
Moisture and chemical immunityUnder 0.01% water absorption prevents wet-insulation galvanic EMF drift in steam autoclaves, acids, solvents and outdoor trays

Duplex FEP (200 °C), PFA (260 °C) & PTFE (260 °C) Thermocouple Wire Schedule

Duplex Fluoropolymer Thermocouple Wire (FEP +200 °C, PFA +260 °C & Sintered PTFE +260 °C) — Dimensional & Calibration Schedule
Model & GaugeInsulation / JacketConductor BuildMax. Temp. (°C)CalibrationsNom. Profile / OD (mm)Approx. Weight (kg/km)Standard Spool MOQNext step
TF-TC-FEP 24 AWG SolidFEP / FEP OvalSolid 0.51 mm+200 °CK, J, T, E, N1.4 x 2.49.5305 m / 300 mRequest this size
TF-TC-FEP 24S StrandedFEP / FEP Oval7 x 0.20 mm+200 °CK, J, T, E1.6 x 2.610.5305 m / 300 mRequest this size
TF-TC-FEP 20 AWG SolidFEP / FEP OvalSolid 0.81 mm+200 °CK, J, T, E, N1.7 x 3.016.5305 m / 300 mRequest this size
TF-TC-FEP 20S-TWSHFEP / CuSn Braid / FEP7 x 0.32 mm+200 °CK, J, T, E3.8 round29.5305 m / 300 mRequest this size
KX/TC-PFA 24 AWG SolidPFA / PFA OvalSolid 0.51 mm+260 °CK, J, T, E, N1.4 x 2.49.8305 m / 300 mRequest this size
KX/TC-PFA 24S StrandedPFA / PFA Oval7 x 0.20 mm+260 °CK, J, T, E1.6 x 2.610.8305 m / 300 mRequest this size
KX/TC-PFA 20 AWG SolidPFA / PFA OvalSolid 0.81 mm+260 °CK, J, T, E, N1.7 x 3.016.8305 m / 300 mRequest this size
KX/TC-PFA 20S-TWSHPFA / CuAg Braid / PFA7 x 0.32 mm+260 °CK, J, T, E, N3.8 round30.0305 m / 300 mRequest this size
KX/TC-PFA 16 AWG SolidPFA / PFA OvalSolid 1.29 mm+260 °CK, J, N2.4 x 4.236.0305 m / 300 mRequest this size
KX/TC-PTFE 24S FusedPTFE / PTFE Tape7 x 0.20 mm+260 °CK, J, T, E1.3 x 2.29.5305 m / 300 mRequest this size
KX/TC-PTFE 20S FusedPTFE / PTFE Tape7 x 0.32 mm+260 °CK, J, T, E, N1.5 x 2.716.2305 m / 300 mRequest this size

Screened Multi-Pair KX / JX / TX / EX / NX Fluoropolymer Extension Cable Schedule

Screened Multi-Pair Fluoropolymer Thermocouple Extension Cable (FEP/C/FEP 200 °C & PFA/C/PFA 260 °C) — Marshalling Trunk Schedule
Model & Pair SizeScreen ArchitectureTemp. RatingCalibrationsNom. OD (mm)Approx. Weight (kg/km)Standard Reel MOQNext step
KX-FEP-C-FEP 1x2x0.5Overall CuSn Braid-90 to +200 °CKX, JX, TX, EX, NX4.231300 m reelRequest this size
KX-FEP-C-FEP 2x2x0.5Overall CuSn Braid-90 to +200 °CKX, JX, TX, EX, NX6.458300 m reelRequest this size
KX-FEP-C-FEP 4x2x0.5Ind. + Overall Screen-90 to +200 °CKX, JX, TX, EX, NX8.6108300 m reelRequest this size
KX-FEP-C-FEP 8x2x0.5Ind. + Overall Screen-90 to +200 °CKX, JX, TX, EX, NX11.4196300 m reelRequest this size
KX-FEP-C-FEP 12x2x0.5Ind. + Overall Screen-90 to +200 °CKX, JX, TX, EX13.8285300 m reelRequest this size
KX-FEP-C-FEP 16x2x0.5Ind. + Overall Screen-90 to +200 °CKX, JX, TX, EX15.6368300 m reelRequest this size
KX-FEP-C-FEP 1x2x1.0Overall CuSn Braid-90 to +200 °CKX, JX, TX, EX, NX5.148300 m reelRequest this size
KX-FEP-C-FEP 4x2x1.0Ind. + Overall Screen-90 to +200 °CKX, JX, TX, EX, NX10.5168300 m reelRequest this size
KX-FEP-C-FEP 8x2x1.0Ind. + Overall Screen-90 to +200 °CKX, JX, TX, EX, NX14.2312300 m reelRequest this size
KX-FEP-C-FEP 12x2x1.5Ind. + Overall Screen-90 to +200 °CKX, JX, EX, NX19.4580300 m reelRequest this size
KX-PFA-C-PFA 4x2x0.5Overall CuAg Braid-90 to +260 °CKX, JX, TX, EX, NX8.4112300 m reelRequest this size
KX-PFA-C-PFA 8x2x1.0Overall CuAg Braid-90 to +260 °CKX, JX, TX, EX, NX13.9318300 m reelRequest this size

ASCII part references for BOM entry: TF-TC-FEP-K-24, TF-TC-FEP-T-24, TF-TC-PFA-K-20-SLE, TF-TC-PFA-T-24-SLE, TF-TC-PTFE-K-20S, TF-KX-FEPC-4X2X05, TF-KX-FEPC-8X2X10, TF-KX-PFAC-4X2X05.

Type T (Cu-CuNi) in melt-extruded PFA or FEP Class 1 (+/-0.5 °C) is the preferred pharmaceutical steam-autoclave and cryogenic (-190 °C to +260 °C) validation wire.

Standards

FEP, PFA & KX IEC 60584-1/3 & ANSI MC96.1 Standards

FEP, PFA & PTFE Thermocouple Wire & Screened Multi-Pair Cable (K, J, T, E, N) standards and test references
Standard or specificationApplication
IEC 60584-1 & IEC 60584-3Thermocouple EMF-temperature reference polynomials, Class 1 / Class 2 tolerance bands and international colour coding (green KX, black JX, brown TX, violet EX, pink NX).
ASTM E230 / ANSI MC96.1North American Standard and Special Limits of Error (SLE) EMF tolerances and ANSI polarity/jacket colour coding.
IEC 60332-1-2Single vertical wire and cable flame-retardant self-extinguishing performance.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and thermoelectric EMF lot calibration records

IEC 60584-1 — Thermocouples: EMF specifications and tolerances

IEC 60584-3 — Extension and compensating cables: tolerances and identification system

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.