Submersible Pump Cables TEBAOFLEX

S07RC4N8-F 450/750 V Screened Submersible Pump Cable

S07RC4N8-F is a 450/750 V screened rubber cable for submersible wastewater pumps and frequency-converter-controlled motors. It combines EPR-insulated conductors, an overall tinned-copper braid and a black CPE outer sheath.

  • 450/750 V
  • EPR insulation, EPDM inner sheath, tinned-copper braid and black CPE outer sheath
  • Class 5 copper; tinned up to 6 mm², plain above 6 mm²
  • 90 °C maximum conductor temperature

Send the configuration, motor or controller drawing, installed length and entry dimensions for a technical quotation.

Product information
Brand
TEBAOFLEX
Product overview

S07RC4N8-F for Pump Connections

S07RC4N8-F is a 450/750 V screened rubber cable for submersible wastewater pumps and frequency-converter-controlled motors. It combines EPR-insulated conductors, an overall tinned-copper braid and a black CPE outer sheath.

The four-core G configurations include a protective conductor as well as the phase conductors. The braid provides the EMC screening function and is not a substitute for the PE connection. Effective screen contact at both cable ends should be planned with the drive, motor and cable-entry system. Keep the braid termination accessible and mechanically protected during installation.

The size table covers 4G1.5 through 4G120, with separate minimum and maximum finished diameters and approximate masses. Use the whole diameter range when choosing a gland or sealing sleeve. A screened cable has a different outside diameter and termination build from an unscreened lead of the same conductor section.

Give the drive output, motor current, installed length and routing with the enquiry. These inputs help coordinate conductor sizing, screen termination and the available bending space. Provide independent cable supports and include the wastewater composition when selecting the sheath and accessories. Immersion depth and water-temperature limits are confirmed for the specified installation.

  • Keep the braid and protective conductor as separate connection functions.
  • Select the seal from the finished OD limits of the exact 4G configuration.
  • Allow space for screen preparation, strain relief and the specified bend.

Selection resources: submersible pump cable range · VFD cable guide.

Construction

Construction

EPR insulation, EPDM inner sheath, tinned-copper braid and black CPE outer sheath. The representative image follows the selected configuration; other sizes retain their stated core arrangement.

S07RC4N8-F 4G10 cross-section with four equal cores, EPDM inner sheath and overall braid
Representative S07RC4N8-F 4G10 construction; configuration-specific dimensions are tabulated separately.
S07RC4N8-F layer schedule
LayerConstruction
ConductorFlexible copper, Class 5; tinned through 6 mm² and plain above 6 mm².
InsulationEPR rubber; four-core power identification to DIN VDE 0293-308.
Inner sheathEPDM rubber where applicable to the selected construction.
SeparatorThin separating film in the illustrated construction.
Overall screenTinned-copper wire braid between inner and outer sheath.
Outer sheathBlack CPE rubber.
Applications

Applications

S07RC4N8-F is a 450/750 V screened rubber cable for submersible wastewater pumps and frequency-converter-controlled motors. It combines EPR-insulated conductors, an overall tinned-copper braid and a black CPE outer sheath.

Black screened pump cable supported along guide rails to a wastewater pump
Application illustration: independently supported electrical cable route and a separate pump lifting arrangement.
S07RC4N8-F selection checkpoints
Selection pointWhat to coordinate
EMC connectionProvide effective braid contact at both cable ends and a separate PE connection.
Entry dimensionsMatch the exact 4G size and its OD limits to the gland or sealing sleeve.
Drive dutyState drive output, motor-cable length, current and routing for the connection design.
Bending spaceAllow the required radius beyond the prepared screen termination and strain relief.

Confirm immersion depth and the maximum permitted water temperature with the enquiry. Support the cable independently; use a separate mechanical system to lift the pump.

Specifications

Specifications

Keep the exact configuration and its installation conditions together when selecting the cable entry and route.

S07RC4N8-F technical parameters
ParameterValue
Rated voltage U₀/U450/750 V
ConductorClass 5 copper; tinned up to 6 mm², plain above 6 mm²
Insulation and sheathEPR insulation, EPDM inner sheath, tinned-copper braid and black CPE outer sheath
Temperature condition90 °C maximum conductor temperature
Maximum operating voltage AC476/825 V
Maximum operating voltage DC619/1238 V
Maximum short-circuit conductor temperature250 °C
Minimum ambient temperature−40 °C fixed; −25 °C flexible
Maximum tensile stress on conductor15 N/mm²
Minimum bending radius4 × maximum OD, fixed; 6 × maximum OD, flexible

S07RC4N8-F Configurations

S07RC4N8-F dimensions and configuration data
ConfigurationMinimum OD (mm)Maximum OD (mm)Approximate mass (kg/km)
S07RC4N8-F 4G1.512.814.4266
S07RC4N8-F 4G2.515.217.2388
S07RC4N8-F 4G41719516
S07RC4N8-F 4G618.920.9630
S07RC4N8-F 4G1023.125.1972
S07RC4N8-F 4G1626.629.61447
S07RC4N8-F 4G2531.834.82015
S07RC4N8-F 4G3535.338.32539
S07RC4N8-F 4G5040.543.53458
S07RC4N8-F 4G7045.248.24586
S07RC4N8-F 4G9550545350
S07RC4N8-F 4G1205760.56780
Standards

Standards

The following references identify the conductor, material and test requirements relevant to this construction.

S07RC4N8-F standards and tests
ReferenceApplication
EN 50525-2-21Design and water-resistance reference
IEC 60228Class 5 conductor reference
EN 60332-1-2Single-cable flame-test reference
EN 60811-404Oil-resistance test reference
AC voltage test2.5 kV AC for 15 minutes

For conductor classes, see the IEC 60228 standard scope.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.