INDUSTRIAL CABLES TEBAOFLEX

NTSCGCWOEU 12/20 kV Floating PV Shore Connection Cable

NTSCGCWOEU is a 12/20 kV screened single-core cable for floating photovoltaic shore connections and medium-voltage routes in water.

  • Class 5 finely stranded tinned copper
  • EPR insulation with inner and outer semiconductive field control
  • Water-resistant EPR inner sheath and concentric tinned-copper wire earth screen
  • Seven listed conductor / concentric-earth configurations
  • Separate fixed and flexible bend requirements

Send the conductor configuration, circuit duty, shore-route drawing, bonding arrangement and water conditions for a technical quotation.

Product information
Brand
TEBAOFLEX
Product overview

NTSCGCWOEU Single-Core Cable for Floating PV Shore Connections

NTSCGCWOEU is a 12/20 kV single-core flexible medium-voltage cable for shore connections from floating photovoltaic installations. It combines a Class 5 tinned-copper conductor, semiconductive EPR field-control layers, special EPR insulation, a water-resistant EPR inner sheath, a concentric tinned-copper wire screen and a special rubber outer sheath.

Plan the shoreline as a connected set of mechanical and electrical interfaces. The cable leaves a floating structure, passes through a supported water route and reaches fixed equipment on land. Independent strain relief, abrasion protection and controlled bend space keep mooring loads and concentrated movement away from the electrical connection.

The seven listed configurations identify the conductor and concentric-earth arrangement together. Compare the minimum and maximum finished diameters with the gland range, and use the cable mass when planning landing supports. Coordinate the wire-screen termination and bonding scheme with the complete single-core phase layout and fault-duty assessment.

For electrical selection, use the resistance, capacitance and current-reference conditions alongside the route length and installation drawing. Fixed and flexible sections have different bend requirements. The conductor-temperature limit applies to the electrical conductor; immersion depth and the permitted water temperature are confirmed for the project.

For NTSCGCWOEU material selection, review plain and tinned copper conductors; for NTSCGCWOEU applications, explore the industrial cable range.

Construction

Construction

The single-core assembly uses a concentric wire screen and a separate inner and outer sheath. Coordinate the wire-screen termination and bonding design with the complete phase circuit.

NTSCGCWOEU 1X70/16KON cross-section with EPR insulation and concentric tinned-copper wire earth screen
Representative single-core construction with inner and outer semiconductive field control, EPR inner sheath and concentric wire earth screen.
NTSCGCWOEU screened single-core construction
ElementConstruction
ConductorClass 5 finely stranded tinned copper.
Inner field-control layerSemiconductive EPR next to the conductor.
InsulationEPR rubber, special compound > 3GI3.
Outer field-control layerSemiconductive EPR over the insulation.
Inner sheathSpecial water-resistant EPR rubber.
Metallic screen / earthConcentric tinned-copper wire screen / earth conductor.
Outer sheathSpecial rubber compound.
GeometrySingle-core round construction.
Applications

Applications

Medium-voltage water routes and floating photovoltaic shore connections with mechanical exposure, supported transitions and controlled movement between floating and fixed equipment.

Supported medium-voltage cable route between a floating photovoltaic platform and shore equipment
Application illustration of a supported floating PV shore connection; the cable is independent of the mooring system.
NTSCGCWOEU floating PV route selection
ParameterValue
Floating PV power exportRoute medium-voltage power between the floating installation and shore-side equipment.
Shore transitionsSupport both landings and coordinate abrasion protection, controlled bends and independent strain relief.
Water-level movementReserve service length within the specified bending and torsion limits; transfer mooring loads to the mechanical support system.
Phase routing and bondingCoordinate the separate single-core phase routes, concentric-earth terminations and bonding design.
Thermal and current selectionApply the listed current values only with their stated installation and ambient reference; assess the actual water route separately.
Entry fitMatch the selected diameter range, cable mass and termination envelope to the landing hardware and gland.
Water compatibilitySpecify the actual water medium, immersion conditions and contaminant exposure.
Specifications

Specifications

Select the conductor and concentric-earth configuration together, then coordinate the diameter range, cable mass, electrical duty and shore-route interfaces.

NTSCGCWOEU ratings and construction profile
ParameterValue
Rated voltage U₀/U12/20 kV
Core count1
ConductorClass 5 finely stranded tinned copper
InsulationEPR special compound > 3GI3
Sheath systemWater-resistant EPR inner sheath; special rubber outer sheath
Metallic screen / earthConcentric tinned-copper wire screen / earth conductor
Highest system voltage Uₘ24 kV
Test voltage29 kV
Maximum conductor temperature90 °C
Short-circuit conductor temperature250 °C
Ambient temperature, fixed installation−40 to +80 °C
Ambient temperature, flexible installation−25 to +60 °C
Minimum bend radius, fixed6 × cable diameter D
Minimum bend radius, flexible10 × cable diameter D
Permanent conductor tensile stress15 N/mm²
Torsional limit±25 °/m
Water-service design referenceAD8
Water-service conditionsImmersion depth and permitted water temperature are confirmed for the project.
NTSCGCWOEU 12/20 kV configurations and dimensions
Model and basic configurationConductor diameter (mm)Minimum cable diameter (mm)Maximum cable diameter (mm)Cable mass (kg/km)
NTSCGCWOEU 1X70/16KON10.833362050
NTSCGCWOEU 1X95/16KON12.635.238.22380
NTSCGCWOEU 1x120/16KON14.236.839.82690
NTSCGCWOEU 1x150/25KON15.840.643.63320
NTSCGCWOEU 1X185/25KON17.441.644.63630
NTSCGCWOEU 1X240/25KON20.444.547.54250
NTSCGCWOEU 1X300/25KON22.947504890
NTSCGCWOEU configuration electrical and mechanical values
Model and basic configurationMaximum tensile force (N)Nominal capacitance (nF/km)Conductor resistance at 20 °C (Ω/km)Reference current (A)
NTSCGCWOEU 1X70/16KON10502400.277360
NTSCGCWOEU 1X95/16KON14252700.21434
NTSCGCWOEU 1x120/16KON18002900.164505
NTSCGCWOEU 1x150/25KON22503200.132582
NTSCGCWOEU 1X185/25KON27753400.108664
NTSCGCWOEU 1X240/25KON36003900.0817780
NTSCGCWOEU 1X300/25KON45004300.0641897

Reference current: one cable on a surface at 30 °C ambient temperature, according to DIN VDE 0298-4, Table 15. Assess the actual route, grouping and thermal conditions before selecting the operating current.

D is the selected cable diameter. Use the fixed or flexible bend factor for the corresponding route section and coordinate termination dimensions with the equipment drawing.

Standards

Standards

NTSCGCWOEU construction and test references
ReferenceApplication
DIN VDE 0250-813Construction reference for the selected medium-voltage cable family.
DIN VDE 0298-3Bending and installation guidance.
DIN VDE 0298-4, Table 15Current-reference conditions: one cable on a surface at 30 °C ambient temperature.
DIN EN 60811-404 / IEC 60811-404Oil-resistance reference.
DIN EN 50525-2-21Water-service material reference.
DIN EN 60332-1-2 / IEC 60332-1-2Single-cable flame-performance reference.
AD8Water-service design reference.

Consult the official DIN VDE 0250-813 standard entry for its scope and edition.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.