MINING & TUNNELING CABLES TEBAOFLEX

Type A and Type B 1.1/1.1 kV Mine Feeder Cable — AS/NZS 1972

AS/NZS 1972 Type A/B 1.1/1.1 kV cable for fixed mine power distribution: three stranded tinned-copper power cores, EPR insulation, copper-wire earth screens and heavy-duty PCP sheath. Type A offers three optional pilots; Type B is supplied without pilots.

Product information
SKU
TF-MIN-P1-M004
Brand
TEBAOFLEX
Product overview

Type A and Type B mine feeder cable distributes power within mines at 1.1/1.1 kV. The construction uses three stranded tinned-copper power conductors, EPR insulation, copper-wire screens that form the earth conductors, an elastomer centre filler and a heavy-duty PCP outer sheath. The listed power-conductor range is 16–240 mm², with construction references to AS/NZS 1972:2006.

Choose Type A when the specified circuit requires the optional three-pilot arrangement. Each pilot is insulated and covered with CPE and placed between the screened power cores. Type B provides the three screened power cores without pilots. State the required pilot arrangement with the power-conductor size: it determines the auxiliary wiring available at the termination and must agree with the mine’s control and protection circuit.

These configurations serve fixed mine distribution, including underground coal-mine installations selected to the project requirements. The copper-wire screens provide the specified earth-conductor sections; they are distinct from steel-wire armour or an additional insulated earth core. For machine connections specified as Type 1 screened machine cable or Type 2S and Type 2S.3 screened machine cables, use the corresponding construction and its own ratings. Match both the voltage and the specified construction when selecting the cable type.

Use the conductor and screen tables to identify the required build, then check the nominal outside diameter against the cable entry and route. TEBAOFLEX supplies Type A/B cable from a 50 m minimum order quantity, with a manufacturing lead time of 7–45 working days. Include the cable type, power size, pilot requirement, length and installation details in the enquiry.

Explore the mining and tunneling cable range for related configurations.

Construction

Construction

Type A and Type B share the screened three-power-core arrangement. The optional three CPE-covered pilots belong to Type A; Type B has no pilot cores. Copper-wire screens around the power cores provide the earth-conductor system. The main image illustrates Type B without pilots; Type A uses the pilot arrangement specified below.

Type A and Type B 1.1/1.1 kV Mine Feeder Cable — AS/NZS 1972 construction
ComponentMaterial and construction
Power conductorsThree Class 2 stranded, tinned annealed copper conductors; 16–240 mm² in the listed series.
Power insulationEPR around each power conductor; thickness varies with conductor area.
Earth screensCopper-wire screens around the individual insulated power cores, with the screen section listed for each size.
Centre fillerElastomer centre filler supports the three-core arrangement.
Type A pilotsThree optional pilot conductors with composite CPE insulation and covering, laid in the interstitial spaces. Pilot stranding and covering thickness follow the size table.
Type B pilot arrangementNo pilot cores.
Outer sheathHeavy-duty PCP enclosing the assembled core.
Applications

Applications

Use the Type A/B designation, pilot requirement and earth-screen section together when specifying a fixed mine distribution circuit.

  • Fixed 1.1/1.1 kV power distribution within mines.
  • Underground coal-mine distribution circuits where this construction and the applicable mine requirements are specified.
  • Type A feeder circuits that require three auxiliary pilot conductors in addition to the screened power cores.
  • Type B feeder circuits that require the screened power cores without auxiliary pilots.
  • Replacement of an existing Type A/B feeder after checking conductor section, screen section, pilot wiring, entry diameter and installation route.

For route and construction selection, see the mining and tunneling cable application guide.

Specifications

Specifications

Type A and Type B 1.1/1.1 kV Mine Feeder Cable — AS/NZS 1972 technical data
ParameterValue
Rated voltage U₀/U1.1/1.1 kV
Power-core countThree
Listed conductor areas16, 25, 35, 50, 70, 95, 120, 150, 185 and 240 mm²
Conductor materialStranded tinned annealed copper
Insulation / sheathEPR / heavy-duty PCP
Earth-conductor arrangementIndividual copper-wire power-core screens
Type A pilot optionThree CPE-insulated and covered pilot cores
Type B pilot arrangementNo pilot cores
Installation dutyFixed mine distribution
Minimum order quantity50 m
Manufacturing lead time7–45 working days
Type A and Type B 1.1/1.1 kV — construction selection
Model and configurationPower-core insulationEarth-conductor arrangementPilot arrangementOuter sheath
Type A 3 power cores + 3 optional pilotsEPRCopper-wire screen around each power coreThree CPE-insulated and covered pilot cores when specifiedHeavy-duty PCP
Type B 3 power cores, without pilotsEPRCopper-wire screen around each power coreNo pilot coresHeavy-duty PCP
Type A 1.1/1.1 kV — power conductors and optional three-pilot configuration
Model and power configurationPower stranding (no./mm)EPR insulation (mm)Earth screen per core (mm²)Each optional pilot (no./mm)Pilot covering (mm)
Type A 3 × 16 mm² + 3 optional pilots7/1.701.46.024/0.201.6
Type A 3 × 25 mm² + 3 optional pilots19/1.351.47.232/0.201.8
Type A 3 × 35 mm² + 3 optional pilots19/1.531.57.930/0.251.8
Type A 3 × 50 mm² + 3 optional pilots19/1.781.79.050/0.252.0
Type A 3 × 70 mm² + 3 optional pilots19/2.141.813.280/0.252.0
Type A 3 × 95 mm² + 3 optional pilots19/2.522.015.180/0.252.0
Type A 3 × 120 mm² + 3 optional pilots37/2.032.222.980/0.252.0
Type A 3 × 150 mm² + 3 optional pilots37/2.252.324.780/0.252.0
Type A 3 × 185 mm² + 3 optional pilots37/2.522.527.580/0.252.0
Type A 3 × 240 mm² + 3 optional pilots61/2.252.764.480/0.252.0
Type B 1.1/1.1 kV — power conductors and earth screens, without pilots
Model and power configurationPower stranding (no./mm)EPR insulation (mm)Copper screen wires (no./mm)Earth screen per core (mm²)
Type B 3 × 16 mm², no pilots7/1.701.448/0.406.0
Type B 3 × 25 mm², no pilots19/1.351.457/0.407.2
Type B 3 × 35 mm², no pilots19/1.531.563/0.407.9
Type B 3 × 50 mm², no pilots19/1.781.772/0.409.0
Type B 3 × 70 mm², no pilots19/2.141.867/0.5013.2
Type B 3 × 95 mm², no pilots19/2.522.077/0.5015.1
Type B 3 × 120 mm², no pilots37/2.032.265/0.6722.9
Type B 3 × 150 mm², no pilots37/2.252.370/0.6724.7
Type B 3 × 185 mm², no pilots37/2.522.578/0.6727.5
Type B 3 × 240 mm², no pilots61/2.252.745/1.3564.4
Type A/B 1.1/1.1 kV — nominal family dimensions and weight
Model and power configurationPCP sheath (mm)Nominal OD (mm)Nominal mass (kg/100 m)
Type A/B 3 × 16 mm²2.524.6120
Type A/B 3 × 25 mm²2.528.0170
Type A/B 3 × 35 mm²2.530.4205
Type A/B 3 × 50 mm²3.034.9270
Type A/B 3 × 70 mm²3.340.2370
Type A/B 3 × 95 mm²3.846.1490
Type A/B 3 × 120 mm²3.851.1615
Type A/B 3 × 150 mm²4.456.0740
Type A/B 3 × 185 mm²5.162.3915
Type A/B 3 × 240 mm²5.772.91290

The pilot stranding and covering columns apply only to the optional three-pilot Type A build. They are not additional earth-conductor specifications.

The dimensions and weight are a joint Type A/B nominal family series. Identify Type A with the selected pilot option or Type B without pilots on the quotation and termination drawing; do not infer a different Type B weight by subtracting pilot copper.

Screen areas refer to the copper-wire earth screen associated with each power core. Match the specified earth system and protection requirements before selecting the cable.

Stranding is shown as number of wires / wire diameter in millimetres. It must not be read as conductor area.

Mass is expressed in kg per 100 m. Dimensions and masses are nominal reference values; confirm the selected build and cable-entry dimensions on the quotation.

Determine the circuit current rating from the selected conductor and the actual installation, ambient and grouping conditions.

AS/NZS 1972 Type A/B and AS/NZS 1972 machine-cable designations such as Type 1 or Type 2S require their own construction and voltage data; they are not interchangeable names.

Standards

Standards

Type A and Type B 1.1/1.1 kV Mine Feeder Cable — AS/NZS 1972 standards and test references
Standard or specificationApplication
AS/NZS 1972:2006Type A/B mine distribution cable construction reference for this 1.1/1.1 kV series.
AS/NZS 1125Copper conductor construction reference.
AS/NZS 3808Insulation and sheathing compound reference.

Official standards and approval references

Certifications and document support

Review our company certificates and document scopes when identifying the documentation required for the quoted construction.

State the required standard edition, Type A or Type B, conductor size, pilot arrangement and any project-specific acceptance documentation. Match the documents to the fixed-distribution construction and the ordered pilot configuration. Standard references and company management-system records serve different purposes from product-specific approval or test records.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.