MINING & TUNNELING CABLES TEBAOFLEX

MKYJV & MKYJVP (450/750 V) XLPE Insulated & Braided-Screen Mining Control Cable

450/750 V coal-mine control cable with annealed copper conductors to GB/T 3956, 90 C XLPE insulation and a flame-retardant PVC sheath designed to MT/T 386 (KA/T 386): MKYJV unscreened and MKYJVP with a collective copper wire braid screen. Discrete range from 0.75 mm2 to 10 mm2 in 2 to 37 cores.

Product information
SKU
CN-MKYJV-MKYJVP
Brand
TEBAOFLEX
Product overview

Coal-mine switchgear, conveyor controls, pump automation and substation protection panels need multi-core control cable that stays stable at higher conductor temperatures and resists fire spread along cable trays. MKYJV and MKYJVP are 450/750 V mining control cables with annealed copper conductors to GB/T 3956, 90 °C cross-linked polyethylene (XLPE) insulation and a flame-retardant PVC sheath designed to the MT/T 386 (KA/T 386) flame test.

MKYJV is the unscreened version for general control, signalling and interlock circuits. MKYJVP adds a collective braided screen of tinned or bare copper wires over the laid-up cores, giving immunity to interference from frequency converters, contactors and power cables sharing the same tray. The production matrix is discrete: 0.75, 1.0, 1.5 and 2.5 mm2 in 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30 and 37 cores; 4 and 6 mm2 in 2 to 19 cores; and 10 mm2 in 2 to 10 cores, always within the same core-count steps.

Compared with PVC-insulated MKVV and MKVVP, the XLPE insulation adds a 90 °C rating instead of 70 °C, lower dielectric losses and capacitance, and better resistance to heat ageing near hot equipment. Armoured or flexible versions are separate enquiry options and are not implied by the MKYJV designation.

Explore the mining and tunneling cable range for related configurations.

Construction

MKYJV and MKYJVP 450/750 V XLPE Control Cable Construction & Screen

The representative horizontal sample shows an MKYJVP 450/750 V 10x1.5 mm2 control cable: ten annealed copper conductors with XLPE insulation and core numbering, a binder tape, a collective braid of tinned copper wires and a black flame-retardant PVC outer sheath.

Flat 2D cross-section diagram of MKYJVP mining control cable showing ten XLPE-insulated copper cores, binder tape, copper wire braid screen and PVC outer sheath
MKYJVP cross-section: numbered cores, braid screen and flame-retardant sheath.
MKYJV & MKYJVP (450/750 V) XLPE Insulated & Braided-Screen Mining Control Cable construction
ComponentMaterial and construction
Copper ConductorsAnnealed copper Class 1 or Class 2 conductors to GB/T 3956 (IEC 60228), 0.75 mm2 to 10 mm2.
XLPE Insulation (90 C)Cross-linked polyethylene insulation with numbered or colour-coded cores; lower permittivity than PVC for reduced capacitance.
Core Lay-Up and BinderCores laid up in concentric layers with fillers where needed and wrapped with a binder tape.
Collective Braid Screen (MKYJVP only)Braid of tinned or bare annealed copper wires over the laid-up cores for interference immunity; MKYJV has no screen.
Flame-Retardant PVC SheathFlame-retardant PVC outer sheath designed to the MT/T 386 (KA/T 386) flame test.

MKYJV and MKYJVP Type Designation Breakdown

  • M: coal-mine cable (Chinese MT/KA designation system)
  • K: control cable
  • YJ: cross-linked polyethylene (XLPE) insulation
  • V: PVC sheath
  • P: braided copper wire collective screen (MKYJVP)
Applications

MKYJV and MKYJVP Coal-Mine Control Applications

Choose MKYJV for general control wiring and MKYJVP wherever converters or power cables share the route.

MKYJVP screened control cables on a tray entering an underground mine switchgear and protection panel room
MKYJV-family control cables at mine switchgear.
  • Control and interlock wiring for underground switchgear, starters and mine substation protection panels.
  • Conveyor, pump and fan automation circuits near frequency converters where the braided screen of MKYJVP limits interference.
  • Fixed control runs near hot equipment where the 90 C XLPE rating gives more margin than 70 C PVC-insulated control cable.
  • Surface preparation plants and coal-handling buildings at Chinese-standard mines specifying MKYJV or MKYJVP by designation.

MKYJV and MKYJVP vs MKVV, Flexible PVC Control Cable and AS/NZS 1972 Type 9 Selection Boundary

MKYJV and MKYJVP compared with related control cables
ProductInsulationMax conductor temperatureScreenBest fit
MKYJV and MKYJVP (this page)XLPE90 CNone (MKYJV) or copper wire braid (MKYJVP)Fixed mining control circuits needing thermal margin
MKVV / MKVVP 450/750 V Mining Control CablePVC70 CNone (MKVV) or copper screen (MKVVP)Standard PVC mining control wiring
Flexible PVC Control Cable — Y, YCY and 600 V VCTPVC70 CUnscreened or screened optionsFlexible industrial control wiring
AS/NZS 1972 Type 9 Screened Mining Control and Signalling CablePer AS/NZS 1972Per AS/NZS 1972ScreenedAS/NZS-specified mining control and signalling

Armoured or flexible-conductor versions of MKYJV are separate enquiry options and are not implied by this designation.

Related selection resources

MKYJV and MKYJVP Frequently Asked Questions

What is the difference between MKYJV and MKYJVP?

Both have 90 C XLPE insulation and a flame-retardant PVC sheath. MKYJVP adds a collective braid of tinned or bare copper wires over the laid-up cores to protect control signals from electrical interference.

Which core counts are available?

For 0.75, 1.0, 1.5 and 2.5 mm2: 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30 and 37 cores. For 4 and 6 mm2: 2 to 19 cores in the same steps. For 10 mm2: 2, 3, 4, 5, 7, 8 and 10 cores.

Why choose XLPE control cable instead of MKVV?

XLPE allows 90 C conductor temperature instead of 70 C, has lower dielectric losses and capacitance, and resists heat ageing better near hot equipment.

What are the MOQ and lead time?

The minimum order quantity is 50 m and the manufacturing lead time is 7 to 45 working days, depending on construction and quantity.

Specifications

MKYJV and MKYJVP Core x Cross-Section Matrix & Technical Specifications

MKYJV and MKYJVP Key Specifications

  • Voltage: 450/750 V
  • Insulation: XLPE, 90 °C, flame-retardant PVC sheath
  • Screen: Copper wire braid on MKYJVP; none on MKYJV
  • Range: 0.75 to 10 mm², 2 to 37 cores in discrete steps
  • Supply: MOQ 50 m; 7 to 45 working days
MKYJV & MKYJVP (450/750 V) XLPE Insulated & Braided-Screen Mining Control Cable technical data
ParameterValue
Design standard referenceConductors to GB/T 3956; flame test to MT/T 386 (KA/T 386); the applicable MT/T 818 (KA/T 818) part is confirmed per order
Rated voltage450/750 V
Conductor temperature90 C continuous; 250 C short-circuit for max 5 s
MKYJV vs MKYJVPMKYJV unscreened; MKYJVP with collective tinned or bare copper wire braid screen
Core and cross-section matrix0.75 to 2.5 mm2: 2 to 37 cores; 4 and 6 mm2: 2 to 19 cores; 10 mm2: 2 to 10 cores (discrete steps only)
Commercial supply termsMinimum order quantity 50 m; manufacturing lead time 7 to 45 working days; reference O.D. and mass confirmed on the quotation drawing
Selection boundary vs MKVV / MKVVP and Flexible PVC Control CableChoose MKYJV / MKYJVP for 90 C XLPE fixed mining control circuits; choose MKVV / MKVVP for 70 C PVC-insulated mining control cable and Flexible PVC Control Cable for flexible industrial control wiring.

MKYJV and MKYJVP Core x Cross-Section Matrix

MKYJV and MKYJVP 450/750 V XLPE Mining Control Cable — Discrete Core x Cross-Section Matrix
Model and Cross-SectionAvailable Core Counts (MKYJV and MKYJVP)Number of Core OptionsNext step
MKYJV / MKYJVP 0.75 mm²2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 3715Request this size
MKYJV / MKYJVP 1.0 mm²2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 3715Request this size
MKYJV / MKYJVP 1.5 mm²2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 3715Request this size
MKYJV / MKYJVP 2.5 mm²2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 3715Request this size
MKYJV / MKYJVP 4.0 mm²2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 1911Request this size
MKYJV / MKYJVP 6.0 mm²2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 1911Request this size
MKYJV / MKYJVP 10 mm²2, 3, 4, 5, 7, 8, 107Request this size

MKYJV vs MKYJVP Construction Comparison

MKYJV vs MKYJVP — Construction and Rating Comparison
ParameterMKYJV (unscreened)MKYJVP (braid screened)
Rated voltage U0/U450/750 V450/750 V
ConductorAnnealed copper, Class 1 or Class 2 to GB/T 3956Annealed copper, Class 1 or Class 2 to GB/T 3956
InsulationXLPE, 90 C continuousXLPE, 90 C continuous
Collective screenNoneBraid of tinned or bare copper wires over the laid-up cores
Outer sheathFlame-retardant PVC to the MT/T 386 (KA/T 386) flame testFlame-retardant PVC to the MT/T 386 (KA/T 386) flame test
Short-circuit conductor temperature250 C for max 5 s250 C for max 5 s
Minimum bending radiusAt least 6 x overall diameterAt least 12 x overall diameter
InstallationFixed installation on trays, in ducts or on bracketsFixed installation on trays, in ducts or on brackets
Core identificationNumbered or colour-coded coresNumbered or colour-coded cores

Only the listed core counts are offered for each cross-section; reference outer diameters and masses for each combination are issued on the quotation drawing.

Under China National Mine Safety Administration Announcement No. 2 of 2026, MT 818.1 became KA 818.1 and MT/T 818.2 to MT/T 818.14 and MT/T 386 became KA/T 818.2 to KA/T 818.14 and KA/T 386, keeping their years; project-specific certification and test scope is verified per order, and no MA safety-mark coverage is claimed on this page.

ASCII part references for BOM and ERP entry: MKYJV and MKYJVP 2x0.75 to 37x0.75, MKYJV and MKYJVP 2x1.0 to 37x1.0, MKYJV and MKYJVP 2x1.5 to 37x1.5, MKYJV and MKYJVP 2x2.5 to 37x2.5, MKYJV and MKYJVP 2x4.0 to 19x4.0, MKYJV and MKYJVP 2x6.0 to 19x6.0, MKYJV and MKYJVP 2x10 to 10x10.

Standards

MKYJV Standards & Test References (GB/T 3956, MT/T 386, GB/T 9330)

MKYJV & MKYJVP (450/750 V) XLPE Insulated & Braided-Screen Mining Control Cable standards and test references
Standard or specificationApplication
GB/T 3956 / IEC 60228Conductors of insulated cables: Class 1 and Class 2 copper conductors and maximum DC resistance.
MT/T 386-2011 (KA/T 386-2011)Flame-retardant performance test methods and assessment rules for coal-mine cables.
GB/T 9330Plastic-insulated control cables, used as the general construction reference for XLPE-insulated control cable.
MT/T 818 series (KA/T 818 series)Coal-mine cable standard series; the part applicable to the ordered construction is confirmed per order.

Certifications and document support

TEBAOFLEX company certificates and quality system documentation

National Public Service Platform for Standards Information (SAMR, China) — GB/T and coal-industry standard records

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.