MKYJV & MKYJVP (450/750 V) XLPE Insulated & Braided-Screen Mining Control Cable
450/750 V coal-mine control cable with annealed copper conductors to GB/T 3956, 90 C XLPE insulation and a flame-retardant PVC sheath designed to MT/T 386 (KA/T 386): MKYJV unscreened and MKYJVP with a collective copper wire braid screen. Discrete range from 0.75 mm2 to 10 mm2 in 2 to 37 cores.
Coal-mine switchgear, conveyor controls, pump automation and substation protection panels need multi-core control cable that stays stable at higher conductor temperatures and resists fire spread along cable trays. MKYJV and MKYJVP are 450/750 V mining control cables with annealed copper conductors to GB/T 3956, 90 °C cross-linked polyethylene (XLPE) insulation and a flame-retardant PVC sheath designed to the MT/T 386 (KA/T 386) flame test.
MKYJV is the unscreened version for general control, signalling and interlock circuits. MKYJVP adds a collective braided screen of tinned or bare copper wires over the laid-up cores, giving immunity to interference from frequency converters, contactors and power cables sharing the same tray. The production matrix is discrete: 0.75, 1.0, 1.5 and 2.5 mm2 in 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30 and 37 cores; 4 and 6 mm2 in 2 to 19 cores; and 10 mm2 in 2 to 10 cores, always within the same core-count steps.
Compared with PVC-insulated MKVV and MKVVP, the XLPE insulation adds a 90 °C rating instead of 70 °C, lower dielectric losses and capacitance, and better resistance to heat ageing near hot equipment. Armoured or flexible versions are separate enquiry options and are not implied by the MKYJV designation.
Explore the mining and tunneling cable range for related configurations.
MKYJV and MKYJVP 450/750 V XLPE Control Cable Construction & Screen
The representative horizontal sample shows an MKYJVP 450/750 V 10x1.5 mm2 control cable: ten annealed copper conductors with XLPE insulation and core numbering, a binder tape, a collective braid of tinned copper wires and a black flame-retardant PVC outer sheath.

| Component | Material and construction |
|---|---|
| Copper Conductors | Annealed copper Class 1 or Class 2 conductors to GB/T 3956 (IEC 60228), 0.75 mm2 to 10 mm2. |
| XLPE Insulation (90 C) | Cross-linked polyethylene insulation with numbered or colour-coded cores; lower permittivity than PVC for reduced capacitance. |
| Core Lay-Up and Binder | Cores laid up in concentric layers with fillers where needed and wrapped with a binder tape. |
| Collective Braid Screen (MKYJVP only) | Braid of tinned or bare annealed copper wires over the laid-up cores for interference immunity; MKYJV has no screen. |
| Flame-Retardant PVC Sheath | Flame-retardant PVC outer sheath designed to the MT/T 386 (KA/T 386) flame test. |
MKYJV and MKYJVP Type Designation Breakdown
- M: coal-mine cable (Chinese MT/KA designation system)
- K: control cable
- YJ: cross-linked polyethylene (XLPE) insulation
- V: PVC sheath
- P: braided copper wire collective screen (MKYJVP)
MKYJV and MKYJVP Coal-Mine Control Applications
Choose MKYJV for general control wiring and MKYJVP wherever converters or power cables share the route.

- Control and interlock wiring for underground switchgear, starters and mine substation protection panels.
- Conveyor, pump and fan automation circuits near frequency converters where the braided screen of MKYJVP limits interference.
- Fixed control runs near hot equipment where the 90 C XLPE rating gives more margin than 70 C PVC-insulated control cable.
- Surface preparation plants and coal-handling buildings at Chinese-standard mines specifying MKYJV or MKYJVP by designation.
MKYJV and MKYJVP vs MKVV, Flexible PVC Control Cable and AS/NZS 1972 Type 9 Selection Boundary
| Product | Insulation | Max conductor temperature | Screen | Best fit |
|---|---|---|---|---|
| MKYJV and MKYJVP (this page) | XLPE | 90 C | None (MKYJV) or copper wire braid (MKYJVP) | Fixed mining control circuits needing thermal margin |
| MKVV / MKVVP 450/750 V Mining Control Cable | PVC | 70 C | None (MKVV) or copper screen (MKVVP) | Standard PVC mining control wiring |
| Flexible PVC Control Cable — Y, YCY and 600 V VCT | PVC | 70 C | Unscreened or screened options | Flexible industrial control wiring |
| AS/NZS 1972 Type 9 Screened Mining Control and Signalling Cable | Per AS/NZS 1972 | Per AS/NZS 1972 | Screened | AS/NZS-specified mining control and signalling |
Armoured or flexible-conductor versions of MKYJV are separate enquiry options and are not implied by this designation.
Related selection resources
- Mining and tunneling cable engineering solutions
- What is XLPE insulation? Ratings, XLPE vs PVC and TR-XLPE
- MKVV / MKVVP 450/750 V Mining Control Cable
- Flexible PVC Control Cable — Y, YCY and 600 V VCT
- SOOW Multi-Core 600V MSHA Mining Control Cable
MKYJV and MKYJVP Frequently Asked Questions
What is the difference between MKYJV and MKYJVP?
Both have 90 C XLPE insulation and a flame-retardant PVC sheath. MKYJVP adds a collective braid of tinned or bare copper wires over the laid-up cores to protect control signals from electrical interference.
Which core counts are available?
For 0.75, 1.0, 1.5 and 2.5 mm2: 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30 and 37 cores. For 4 and 6 mm2: 2 to 19 cores in the same steps. For 10 mm2: 2, 3, 4, 5, 7, 8 and 10 cores.
Why choose XLPE control cable instead of MKVV?
XLPE allows 90 C conductor temperature instead of 70 C, has lower dielectric losses and capacitance, and resists heat ageing better near hot equipment.
What are the MOQ and lead time?
The minimum order quantity is 50 m and the manufacturing lead time is 7 to 45 working days, depending on construction and quantity.
MKYJV and MKYJVP Core x Cross-Section Matrix & Technical Specifications
MKYJV and MKYJVP Key Specifications
- Voltage: 450/750 V
- Insulation: XLPE, 90 °C, flame-retardant PVC sheath
- Screen: Copper wire braid on MKYJVP; none on MKYJV
- Range: 0.75 to 10 mm², 2 to 37 cores in discrete steps
- Supply: MOQ 50 m; 7 to 45 working days
| Parameter | Value |
|---|---|
| Design standard reference | Conductors to GB/T 3956; flame test to MT/T 386 (KA/T 386); the applicable MT/T 818 (KA/T 818) part is confirmed per order |
| Rated voltage | 450/750 V |
| Conductor temperature | 90 C continuous; 250 C short-circuit for max 5 s |
| MKYJV vs MKYJVP | MKYJV unscreened; MKYJVP with collective tinned or bare copper wire braid screen |
| Core and cross-section matrix | 0.75 to 2.5 mm2: 2 to 37 cores; 4 and 6 mm2: 2 to 19 cores; 10 mm2: 2 to 10 cores (discrete steps only) |
| Commercial supply terms | Minimum order quantity 50 m; manufacturing lead time 7 to 45 working days; reference O.D. and mass confirmed on the quotation drawing |
| Selection boundary vs MKVV / MKVVP and Flexible PVC Control Cable | Choose MKYJV / MKYJVP for 90 C XLPE fixed mining control circuits; choose MKVV / MKVVP for 70 C PVC-insulated mining control cable and Flexible PVC Control Cable for flexible industrial control wiring. |
MKYJV and MKYJVP Core x Cross-Section Matrix
| Model and Cross-Section | Available Core Counts (MKYJV and MKYJVP) | Number of Core Options | Next step |
|---|---|---|---|
| MKYJV / MKYJVP 0.75 mm² | 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37 | 15 | Request this size |
| MKYJV / MKYJVP 1.0 mm² | 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37 | 15 | Request this size |
| MKYJV / MKYJVP 1.5 mm² | 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37 | 15 | Request this size |
| MKYJV / MKYJVP 2.5 mm² | 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37 | 15 | Request this size |
| MKYJV / MKYJVP 4.0 mm² | 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19 | 11 | Request this size |
| MKYJV / MKYJVP 6.0 mm² | 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19 | 11 | Request this size |
| MKYJV / MKYJVP 10 mm² | 2, 3, 4, 5, 7, 8, 10 | 7 | Request this size |
MKYJV vs MKYJVP Construction Comparison
| Parameter | MKYJV (unscreened) | MKYJVP (braid screened) |
|---|---|---|
| Rated voltage U0/U | 450/750 V | 450/750 V |
| Conductor | Annealed copper, Class 1 or Class 2 to GB/T 3956 | Annealed copper, Class 1 or Class 2 to GB/T 3956 |
| Insulation | XLPE, 90 C continuous | XLPE, 90 C continuous |
| Collective screen | None | Braid of tinned or bare copper wires over the laid-up cores |
| Outer sheath | Flame-retardant PVC to the MT/T 386 (KA/T 386) flame test | Flame-retardant PVC to the MT/T 386 (KA/T 386) flame test |
| Short-circuit conductor temperature | 250 C for max 5 s | 250 C for max 5 s |
| Minimum bending radius | At least 6 x overall diameter | At least 12 x overall diameter |
| Installation | Fixed installation on trays, in ducts or on brackets | Fixed installation on trays, in ducts or on brackets |
| Core identification | Numbered or colour-coded cores | Numbered or colour-coded cores |
Only the listed core counts are offered for each cross-section; reference outer diameters and masses for each combination are issued on the quotation drawing.
Under China National Mine Safety Administration Announcement No. 2 of 2026, MT 818.1 became KA 818.1 and MT/T 818.2 to MT/T 818.14 and MT/T 386 became KA/T 818.2 to KA/T 818.14 and KA/T 386, keeping their years; project-specific certification and test scope is verified per order, and no MA safety-mark coverage is claimed on this page.
ASCII part references for BOM and ERP entry: MKYJV and MKYJVP 2x0.75 to 37x0.75, MKYJV and MKYJVP 2x1.0 to 37x1.0, MKYJV and MKYJVP 2x1.5 to 37x1.5, MKYJV and MKYJVP 2x2.5 to 37x2.5, MKYJV and MKYJVP 2x4.0 to 19x4.0, MKYJV and MKYJVP 2x6.0 to 19x6.0, MKYJV and MKYJVP 2x10 to 10x10.
MKYJV Standards & Test References (GB/T 3956, MT/T 386, GB/T 9330)
| Standard or specification | Application |
|---|---|
| GB/T 3956 / IEC 60228 | Conductors of insulated cables: Class 1 and Class 2 copper conductors and maximum DC resistance. |
| MT/T 386-2011 (KA/T 386-2011) | Flame-retardant performance test methods and assessment rules for coal-mine cables. |
| GB/T 9330 | Plastic-insulated control cables, used as the general construction reference for XLPE-insulated control cable. |
| MT/T 818 series (KA/T 818 series) | Coal-mine cable standard series; the part applicable to the ordered construction is confirmed per order. |
Certifications and document support
TEBAOFLEX company certificates and quality system documentation
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
MKVV / MKVVP 450/750 V Mining Control Cable
A related cable option for a different application or duty profile.
View productFlexible PVC Control Cable – Y, YCY and 600 V VCT
A related cable option for a different application or duty profile.
View productSOOW Multi-Core 600V MSHA Mining Control Cable (5 to 60 Cores)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.