MKVV / MKVVP 450/750 V Mining Control Cable

MKVV and MKVVP mining control cables connect fixed control, monitoring and protection circuits at 450/750 V. Both use copper conductors with PVC insulation and a flame-retardant PVC sheath; MKVVP adds an overall copper-wire braid. The listed configurations cover 0.75–10 mm², with core counts depending on conductor size. Send the model, core schedule, route and required documents for a quotation.

Product information
SKU
TF-MIN-P1B2-M009
Brand
TEBAOFLEX
Product overview

MKVV mining control cable carries control, monitoring and protection circuits in fixed underground installations at 450/750 V. This family covers two constructions: unscreened MKVV and overall copper-braided MKVVP. Both use copper conductors and PVC insulation and sheathing. Choose between them from the circuit and routing requirements, then select the conductor size and number of cores from the separate configuration tables.

The P suffix identifies the copper-wire screen. It changes the termination arrangement and cable diameter, so an MKVVP cable should not be ordered from an MKVV dimension alone. Where screening is required, the panel entry, screen connection and equipment earthing arrangement need to work together. Where the circuit does not require a screen, the unscreened construction offers a distinct selection within the same fixed control-cable family.

These products serve fixed routes between control cabinets, distribution equipment and monitoring or protection devices. Their copper conductors are Class 1 or Class 2, rather than a high-flexibility conductor selected for repeated movement. A cable that fits a stationary panel connection still needs a different duty assessment if it will travel on a reel, pass through a drag chain or hang unsupported in a shaft.

Use the model-specific size tables to check entries and available space before requesting a quote. Final conductor class, core identification, screen termination and drum lengths belong on the order specification. TEBAOFLEX supplies this family from 50 m, with a confirmed production lead-time range of 7–45 working days.

Explore the mining and tunneling cable range for related configurations.

Construction

Construction

MKVV and MKVVP share copper conductors, PVC-insulated cores and a PVC outer sheath. MKVVP adds one overall copper-wire braid outside the bound core assembly. The main image illustrates a representative MKVVP 3 × 1.5 mm² construction with solid copper conductors.

MKVV / MKVVP 450/750 V Mining Control Cable construction
ComponentMaterial and construction
ConductorsCopper, Class 1 solid or Class 2 stranded to GB/T 3956; specify the conductor class on the order.
Core insulationPVC insulation on each conductor. Core identification is selected to match the circuit schedule.
Core assemblyInsulated cores laid together with fillers and binding tape as required by the configuration.
MKVV screenNo metallic screen in the MKVV construction.
MKVVP screenOverall copper-wire braid around the bound core assembly; this is an electrical screen, not steel armour.
Outer sheathFlame-retardant PVC. Neither construction includes a steel-tape or steel-wire armour layer.
Applications

Applications

Select MKVV or MKVVP for fixed control wiring after checking the circuit voltage, installation route and required screen connection. The two models share a nominal voltage but have different outer dimensions.

  • Fixed control connections between mine electrical equipment and control cabinets.
  • Monitoring, signalling and protection circuits specified for 450/750 V control cable.
  • MKVVP where an overall copper braid is required by the control-system design; arrange screen termination with the equipment supplier.
  • MKVV where the specified fixed circuit does not require an overall metallic screen.
  • Select a cable designed for repeated movement for reels or cable chains. Neither the braid nor the PVC sheath supplies a rated shaft suspension member.

For route and construction selection, see mining and tunneling cable selection.

For an industrial circuit that requires flexible conductors, compare the Y / YCY / VCT flexible PVC control family and verify the installation duty and voltage separately.

For copper communication circuits arranged as pairs or quads, see the MHYV mining communication cable family. Its circuit grouping and construction differ from this multicore control range.

Specifications

Specifications

MKVV / MKVVP 450/750 V Mining Control Cable technical data
ParameterValue
ModelMKVV / MKVVP
Voltage rating450/750 V
ConductorCopper, Class 1 or Class 2
Insulation / sheathPVC / flame-retardant PVC
ScreenMKVV: none; MKVVP: overall copper-wire braid
InstallationFixed control, monitoring and protection circuits
Operating temperature−20 to +70 °C
Minimum bending radius6 × cable outer diameter
Conductor sizes0.75, 1.0, 1.5, 2.5, 4, 6 and 10 mm²
Minimum order quantity50 m
Production lead time7–45 working days
MKVV reference configurations, diameters and weights
Model and core configurationReference outer diameter (mm)Reference weight (kg/km)
MKVV 2 × 0.75 mm²7.060
MKVV 3 × 0.75 mm²7.372
MKVV 4 × 0.75 mm²7.988
MKVV 5 × 0.75 mm²8.6104
MKVV 7 × 0.75 mm²9.2125
MKVV 8 × 0.75 mm²10.2152
MKVV 10 × 0.75 mm²11.5178
MKVV 12 × 0.75 mm²11.8201
MKVV 14 × 0.75 mm²12.4228
MKVV 16 × 0.75 mm²13.6274
MKVV 19 × 0.75 mm²14.3308
MKVV 24 × 0.75 mm²16.5385
MKVV 27 × 0.75 mm²16.8421
MKVV 30 × 0.75 mm²17.4460
MKVV 37 × 0.75 mm²18.7546
MKVV 2 × 1.0 mm²7.369
MKVV 3 × 1.0 mm²7.785
MKVV 4 × 1.0 mm²8.4104
MKVV 5 × 1.0 mm²9.0123
MKVV 7 × 1.0 mm²9.7150
MKVV 8 × 1.0 mm²10.8181
MKVV 10 × 1.0 mm²12.1212
MKVV 12 × 1.0 mm²12.5243
MKVV 14 × 1.0 mm²13.7294
MKVV 16 × 1.0 mm²14.4329
MKVV 19 × 1.0 mm²15.1372
MKVV 24 × 1.0 mm²17.5467
MKVV 27 × 1.0 mm²17.9512
MKVV 30 × 1.0 mm²18.5561
MKVV 37 × 1.0 mm²20.3686
MKVV 2 × 1.5 mm²8.288
MKVV 3 × 1.5 mm²8.7111
MKVV 4 × 1.5 mm²9.4136
MKVV 5 × 1.5 mm²10.2163
MKVV 7 × 1.5 mm²11.1201
MKVV 8 × 1.5 mm²12.4244
MKVV 10 × 1.5 mm²14.5306
MKVV 12 × 1.5 mm²15.0350
MKVV 14 × 1.5 mm²15.7398
MKVV 16 × 1.5 mm²16.5447
MKVV 19 × 1.5 mm²17.4507
MKVV 24 × 1.5 mm²20.6656
MKVV 27 × 1.5 mm²21.1721
MKVV 30 × 1.5 mm²21.8790
MKVV 37 × 1.5 mm²23.5942
MKVV 2 × 2.5 mm²9.5123
MKVV 3 × 2.5 mm²10.0157
MKVV 4 × 2.5 mm²10.9196
MKVV 5 × 2.5 mm²11.9236
MKVV 7 × 2.5 mm²13.5313
MKVV 8 × 2.5 mm²15.1378
MKVV 10 × 2.5 mm²17.0447
MKVV 12 × 2.5 mm²17.5514
MKVV 14 × 2.5 mm²18.4587
MKVV 16 × 2.5 mm²19.8679
MKVV 19 × 2.5 mm²20.8773
MKVV 24 × 2.5 mm²24.3975
MKVV 27 × 2.5 mm²24.81075
MKVV 30 × 2.5 mm²25.71182
MKVV 37 × 2.5 mm²27.81417
MKVV 2 × 4 mm²10.3160
MKVV 3 × 4 mm²11.0209
MKVV 4 × 4 mm²11.9262
MKVV 5 × 4 mm²13.6337
MKVV 7 × 4 mm²14.8424
MKVV 8 × 4 mm²16.6512
MKVV 10 × 4 mm²18.7607
MKVV 12 × 4 mm²19.8722
MKVV 14 × 4 mm²20.7825
MKVV 16 × 4 mm²21.9933
MKVV 19 × 4 mm²23.01067
MKVV 2 × 6 mm²11.4210
MKVV 3 × 6 mm²12.1278
MKVV 4 × 6 mm²13.8372
MKVV 5 × 6 mm²15.1452
MKVV 7 × 6 mm²16.4576
MKVV 8 × 6 mm²18.4692
MKVV 10 × 6 mm²21.2846
MKVV 12 × 6 mm²21.9983
MKVV 14 × 6 mm²23.01128
MKVV 16 × 6 mm²24.31277
MKVV 19 × 6 mm²25.61469
MKVV 2 × 10 mm²15.3361
MKVV 3 × 10 mm²16.3477
MKVV 4 × 10 mm²17.9605
MKVV 5 × 10 mm²19.6739
MKVV 7 × 10 mm²21.8961
MKVV 8 × 10 mm²24.61165
MKVV 10 × 10 mm²27.91388
MKVVP reference configurations, diameters and weights
Model and core configurationReference outer diameter (mm)Reference weight (kg/km)
MKVVP 2 × 0.75 mm²7.784
MKVVP 3 × 0.75 mm²8.097
MKVVP 4 × 0.75 mm²8.6115
MKVVP 5 × 0.75 mm²9.3134
MKVVP 7 × 0.75 mm²9.9158
MKVVP 8 × 0.75 mm²10.9188
MKVVP 10 × 0.75 mm²12.2219
MKVVP 12 × 0.75 mm²13.1262
MKVVP 14 × 0.75 mm²13.7292
MKVVP 16 × 0.75 mm²14.5338
MKVVP 19 × 0.75 mm²15.2376
MKVVP 24 × 0.75 mm²17.4465
MKVVP 27 × 0.75 mm²17.7502
MKVVP 30 × 0.75 mm²18.3545
MKVVP 37 × 0.75 mm²20.0655
MKVVP 2 × 1.0 mm²8.094
MKVVP 3 × 1.0 mm²8.4111
MKVVP 4 × 1.0 mm²9.1133
MKVVP 5 × 1.0 mm²9.7155
MKVVP 7 × 1.0 mm²10.4184
MKVVP 8 × 1.0 mm²11.5220
MKVVP 10 × 1.0 mm²13.4274
MKVVP 12 × 1.0 mm²13.8307
MKVVP 14 × 1.0 mm²14.6359
MKVVP 16 × 1.0 mm²15.3398
MKVVP 19 × 1.0 mm²16.0444
MKVVP 24 × 1.0 mm²18.4552
MKVVP 27 × 1.0 mm²18.8599
MKVVP 30 × 1.0 mm²19.4651
MKVVP 37 × 1.0 mm²21.2784
MKVVP 2 × 1.5 mm²8.9117
MKVVP 3 × 1.5 mm²9.4142
MKVVP 4 × 1.5 mm²10.1170
MKVVP 5 × 1.5 mm²10.9200
MKVVP 7 × 1.5 mm²11.8241
MKVVP 8 × 1.5 mm²13.7307
MKVVP 10 × 1.5 mm²15.4376
MKVVP 12 × 1.5 mm²15.9422
MKVVP 14 × 1.5 mm²16.6473
MKVVP 16 × 1.5 mm²17.4526
MKVVP 19 × 1.5 mm²18.3600
MKVVP 24 × 1.5 mm²21.5756
MKVVP 27 × 1.5 mm²22.0824
MKVVP 30 × 1.5 mm²22.7896
MKVVP 37 × 1.5 mm²24.41057
MKVVP 2 × 2.5 mm²10.2157
MKVVP 3 × 2.5 mm²10.7193
MKVVP 4 × 2.5 mm²11.6235
MKVVP 5 × 2.5 mm²13.2297
MKVVP 7 × 2.5 mm²14.4377
MKVVP 8 × 2.5 mm²16.0450
MKVVP 10 × 2.5 mm²17.9529
MKVVP 12 × 2.5 mm²18.4599
MKVVP 14 × 2.5 mm²19.7694
MKVVP 16 × 2.5 mm²20.7775
MKVVP 19 × 2.5 mm²21.7874
MKVVP 24 × 2.5 mm²25.41124
MKVVP 27 × 2.5 mm²25.91227
MKVVP 30 × 2.5 mm²26.81339
MKVVP 37 × 2.5 mm²29.51628
MKVVP 2 × 4 mm²11.0197
MKVVP 3 × 4 mm²11.7248
MKVVP 4 × 4 mm²13.2323
MKVVP 5 × 4 mm²14.5401
MKVVP 7 × 4 mm²15.7494
MKVVP 8 × 4 mm²17.5592
MKVVP 10 × 4 mm²20.0716
MKVVP 12 × 4 mm²20.7818
MKVVP 14 × 4 mm²21.6925
MKVVP 16 × 4 mm²22.81039
MKVVP 19 × 4 mm²23.91179
MKVVP 2 × 6 mm²12.1251
MKVVP 3 × 6 mm²13.4340
MKVVP 4 × 6 mm²14.7438
MKVVP 5 × 6 mm²16.0525
MKVVP 7 × 6 mm²17.3655
MKVVP 8 × 6 mm²19.7799
MKVVP 10 × 6 mm²22.1949
MKVVP 12 × 6 mm²22.81090
MKVVP 14 × 6 mm²23.91240
MKVVP 16 × 6 mm²25.41426
MKVVP 19 × 6 mm²26.71626
MKVVP 2 × 10 mm²16.2434
MKVVP 3 × 10 mm²17.2555
MKVVP 4 × 10 mm²18.8692
MKVVP 5 × 10 mm²20.9853
MKVVP 7 × 10 mm²22.71067
MKVVP 8 × 10 mm²25.71316
MKVVP 10 × 10 mm²29.01559

The tables list discrete configurations. For 0.75–2.5 mm², the listed core counts are 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30 and 37. For 4 and 6 mm², the list ends at 19 cores; for 10 mm² it ends at 10 cores.

Diameters and weights are reference design values. Confirm the final construction drawing before selecting glands, clamps, drum capacity or transport allowances. Do not apply the unscreened dimensions to the braided cable.

The 6D radius uses the finished cable outer diameter. It is a bending requirement for this fixed-installation family, not a flex-cycle or reeling-life rating.

Specify conductor class, core identification, circuit voltage, screening arrangement, route exposure and the installation temperature. The operating-temperature range is not an instruction to install the cable at its lower limit.

Standards

Standards

MKVV / MKVVP 450/750 V Mining Control Cable standards and test references
Standard or specificationApplication
GB/T 3956Conductor construction: Class 1 or Class 2 copper, as specified for the order.
MT 386 series / KA/T 386-2011Coal-mine cable flame-test methods and assessment rules. The current KA/T 386-2011 registration replaces MT/T 386-2011; retain the exact standard designation on the applicable project documents.

Official standards and approval references

Use the specified conductor standard and flame-test designation when defining the cable inspection and documentation requirements. A standards reference and a product approval serve different purposes.

Certifications and document support

Review our company certificates and document scopes when identifying the documentation required for the quoted construction.

Company certificates describe their stated organizational scope. For this control-cable family, request the model-specific documents required by the destination mine and match them to the quoted construction. Certificates for MYP, MYPT or MYPTJ cover different product models.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.