TF-FLC-XT 8.7/15 kV 3×120+70+12×2.5+12FO Flat Reeling Cable (RIKEN RNEDAFLAT-XT Replacement)
TF-FLC-XT 8.7/15 kV 3×120 + 70 + 12×2.5 + 12FO (50/125) is TEBAOFLEX's slot-matched flat electro-optical crane reeling cable engineered as a drop-in replacement for legacy RIKEN RNEDAFLAT-XT (crane drawing ref. SP12-31-0117), combining three IEC 60228 Class 5 120 mm² EPR-screened phase cores, one 70 mm² earth core, twelve 2.5 mm² control cores and 12 GI 50/125 or SM 9/125 fibres in a 34.5 × 120.0 mm profile.
TF-FLC-XT 8.7/15 kV 3×120 + 70 + 12×2.5 + 12FO (Um 18 kV AC) resolves spare-part obsolescence on container-terminal ship-to-shore (STS) and rail-mounted gantry (RMG) cranes whose maintenance manuals list legacy RIKEN RNEDAFLAT-XT or equipment drawing SP12-31-0117. Manufactured to a nominal 34.5 × 120.0 mm cross-section (maximum 38.4 × 123.8 mm), minimum 500 mm dynamic single-plane bend radius, 9,750 kg/km linear mass, and 7.9 kN reinforced pulling rating (2.6 kN continuous working tension, ≤ 4.9 kN/m radial drum pressure), it seats directly into existing 125 mm monospiral drum slots without altering flange spacing or wharf trench guides.
Within the heavy-duty black polychloroprene (CR / 5GM5) flat outer sheath, five functional units sit in a balanced parallel plane—L1 (120 mm²) · PE (70 mm²) · L2 (120 mm²) · [12×2.5 mm² control + 12FO optical bundle] · L3 (120 mm²)—eliminating inter-core migration during high-stack radial winding. Every 120 mm² phase core uses full IEC 60228 Class 5 tinned copper stranding (≤ 0.164 Ω/km at 20 °C, approximately 608 × 0.50 mm wires) insulated with triple-extruded inner semi-conductive elastomer, 3GI3 EPR dielectric and strippable outer semi-con screen, routine-tested at 24 kV AC for 5 minutes.
Specify TF-FLC-XT when replacing legacy RNEDAFLAT-XT 8.7/15 kV or 6/10 kV power-control-optical flat crane cables on fixed-slot monospiral reels (MOQ 50 m, 7 to 45 working days lead time). For split-earth DIN VDE 0250-813 standard optical reels choose (N)TSFLCGEWÖU-FO, and for 3.3/6.6 kV JCS drums select FG-H-3PNCT. RIKEN and RNEDAFLAT-XT are third-party designations cited solely for dimensional cross-reference; TEBAOFLEX is an independent manufacturer.
Explore the port, crane reeling and festoon cable range for related configurations.
TF-FLC-XT 8.7/15 kV 3×120+70+12×2.5+12FO Cable Construction
TF-FLC-XT reproduces the exact five-channel single-plane geometry required by legacy Japanese-built container crane monospiral reels while applying verifiable IEC 60228 and DIN VDE 0250-813 medium-voltage dielectric controls: [3 × 120 mm² Class 5 Tinned Cu + Triple-Extruded 3GI3 EPR + Cu Screen (L1, L2, L3)] + [1 × 70 mm² Insulated PE Core] + [Composite Sub-Bundle: Central 12FO (GI 50/125 or SM 9/125) Tube Surrounded by 12 × 2.5 mm² Control Cores] -> [Black CR / 5GM5 Flat Outer Sheath].

| Component | Material and construction |
|---|---|
| 1. Medium-voltage phase conductors (3 × 120 mm²) | Annealed tinned flexible copper to IEC 60228 Class 5 (approx. 608 × 0.50 mm fine wires, max. DC resistance 0.164 Ω/km at 20 °C), preventing strand fatigue over 500 mm minimum bending radii. |
| 2. Triple-extruded 8.7/15 kV EPR dielectric & Cu screen | Simultaneously extruded inner semi-conductive stress-control layer, ≥ 4.5 mm nominal 3GI3 ozone-resistant EPR insulation, cold-strippable outer semi-con layer, and tinned copper wire/tape earth screen on L1, L2 and L3. |
| 3. Dedicated protective earth core (1 × 70 mm²) | IEC 60228 Class 5 tinned copper conductor (max. DC resistance 0.277 Ω/km at 20 °C) with heavy elastomer insulation positioned between L1 and L2 to balance flat-plane bending stiffness. |
| 4. Pilot & auxiliary control cores (12 × 2.5 mm²) | Twelve IEC 60228 Class 5 tinned copper 2.5 mm² cores (max. 8.21 Ω/km at 20 °C) with 0.6/1 kV EPR insulation, high-contrast white number coding, and 3.5 kV / 5 min AC routine dielectric verification. |
| 5. Buffered optical fibre subunit (12FO / 24FO) | Crush-resistant ETFE (7YI1) / PBT loose buffer subunit positioned at the neutral axis of the 12 × 2.5 mm² control assembly, housing 12 multimode GI 50/125 µm (OM2/OM3) or single-mode 9/125 µm (ITU-T G.652.D / G.657.A2) fibres. |
| 6. Heavy-duty flat polychloroprene outer sheath | Vulcanized black CR / 5GM5 rubber compound (brick-red optional) engineered for narrow monospiral flange guidance, mineral-oil immersion (IEC 60811-404), marine UV/salt-mist exposure, and IEC 60332-1-2 flame retardance. |
TF-FLC-XT & RNEDAFLAT-XT Cross-Reference Code Breakdown
- TF-FLC-XT: TEBAOFLEX custom slot-matched flat electro-optical crane reeling series engineered for legacy crane BOM cross-reference replacements
- 8.7/15 kV: Rated phase-to-earth voltage U0 = 8.7 kV and phase-to-phase voltage U = 15 kV (maximum system voltage Um = 17.5–18 kV AC)
- 3×120 + 70: Three 120 mm² individually screened MV phase cores (L1, L2, L3) plus one independent 70 mm² protective earth (PE) conductor
- 12×2.5: Twelve 2.5 mm² EPR-insulated fine-stranded tinned copper control/interlock cores grouped into a balanced sub-bundle
- 12FO (50/125): Twelve graded-index 50/125 µm multimode optical fibres (or optional 9/125 µm single-mode / 24FO upgrade) for crane PLC & TOS telemetry
- Cross-Ref: RNEDAFLAT-XT / SP12-31-0117: Third-party legacy crane reel BOM and equipment drawing identifiers matched dimensionally (34.5 × 120.0 mm) and electrically
TF-FLC-XT Port Crane Monospiral Reel Replacement Applications
TF-FLC-XT is built specifically for port maintenance teams and crane OEMs retrofitting existing narrow-slot monospiral reels without replacing mechanical drums or slip-ring/optical rotary joints.

- Direct slot-matched spare replacement on ship-to-shore (STS) container cranes and rail-mounted gantry (RMG / ASC) cranes originally fitted with legacy RIKEN RNEDAFLAT-XT 8.7/15 kV 3×120 + 70 + 12×2.5 + 12FO (drawing SP12-31-0117).
- 15 kV class automated container terminal quay feeders combining main hoist/trolley MV power, 12 hardwired safety/brake interlock circuits, and 12FO / 24FO optical crane automation in one flat slot.
- Vertical radial monospiral crane reels stacking 8 to 20 layers inside a 125 mm to 130 mm clear flange gap and paying out into slotted wharf trenches or panzerbelt-covered channels.
- Upgrading legacy GI 50/125 multimode crane drum cables to bend-insensitive ITU-T G.657.A2 single-mode 9/125 fibres or 24FO redundant rings while keeping the exact 34.5 × 120.0 mm outer profile.
- Bulk ship unloaders, shipyard Goliath gantry cranes and rail-mounted stacker-reclaimers operating on 6.6 kV, 10 kV or 15 kV networks.
TF-FLC-XT vs (N)TSFLCGEWÖU-FO vs FG-H-3PNCT vs Round Reeling
| Cable series | Core & earth architecture | Voltage & data channels | When to specify on port cranes |
|---|---|---|---|
| TF-FLC-XT (this page) | 5-unit flat: 3 MV + 1 independent PE + [12×2.5 Ctrl + 12/24FO] | 8.7/15 kV & 6/10 kV + 12×2.5 mm² + 12/24FO | Drop-in replacement for legacy RNEDAFLAT-XT / SP12-31-0117 125 mm monospiral crane drum slots |
| (N)TSFLCGEWÖU-FO / -LWL | 4-unit DIN VDE flat: 3 MV with /4E split earth + 1 FO subunit | 3.6/6 to 12/20 kV + 6–24FO | European DIN VDE 0250-813 monospiral drums without 12×2.5 mm² pilot bundles |
| FG-H-3PNCT / FG-H-3PNCT-C | JCS flat: 3 MV + earth + GI 50/125 FO (+/- control) | 3.3 kV and 6.6 kV + 6–12FO | Japanese-standard 3.3 kV and 6.6 kV STS/RTG monospiral crane reels |
| (N)TSCGEWÖU+FO | Round concentric-lay torsional core + FO subunit | 3.6/6 to 20/35 kV + 6–24FO | Cylindrical wide drums or multi-plane roller paths subject to ±25°/m torsion |
Always measure the clear inside flange-to-flange width (mm) of your existing monospiral reel before ordering: TF-FLC-XT-8715-120HYB holds a controlled maximum width of 123.8 mm (nominal 120.0 mm) to prevent sidewall wedging inside 125–130 mm crane drum slots.
TF-FLC-XT (RNEDAFLAT-XT Replacement) Crane Drum RFQ Checklist
- Legacy cable jacket marking or crane manual reference (for example RIKEN RNEDAFLAT-XT 8.7/15 kV 3×120 + 70 + 12×2.5 + 12FO or drawing SP12-31-0117).
- Clear inside flange-to-flange slot width (mm), inner barrel diameter (mm) and number of stacked radial layers on the existing monospiral crane drum.
- Optical fibre interface on existing rotary joint / patch panel: multimode GI 50/125 µm (OM2/OM3) or upgrade to single-mode 9/125 µm (ITU-T G.652.D / G.657.A2), 12FO or 24FO.
- Required factory routine / witnessed FAT 5-minute AC withstand voltage on MV cores (24 kV standard, or 21 kV / 30.5 kV project alignment).
- Outer sheath colour preference (standard black CR / 5GM5 matching legacy Japanese drums, or high-visibility brick-red) and factory pre-terminated pulling eye requirement.
- Cut length per reel (MOQ 50 m; manufacturing lead time 7 to 45 working days) and destination container terminal / port.
Related selection resources
- Port, crane reeling and festoon cable catalog
- Engineering guide: measuring monospiral drum slot width and identifying legacy crane reeling cables
- Engineering guide: monospiral flat vs cylindrical round medium-voltage crane reeling selection
- (N)TSFLCGEWÖU-FO / -LWL 3.6/6–12/20 kV DIN VDE 0250-813 flat optical reeling cable schedule
- 3PNCT, H-3PNCT & FG-H-3PNCT 3.3–6.6 kV Japanese-standard crane reeling cables
- (N)TSCGEWÖU / (N)TSCGEWÖU+FO round torsional medium-voltage crane reeling cable
TF-FLC-XT / Legacy RNEDAFLAT-XT 3×120+70+12×2.5+12FO Replacement FAQ
Is TF-FLC-XT a drop-in slot-matched replacement for RIKEN RNEDAFLAT-XT 8.7/15 kV 3×120 + 70 + 12×2.5 + 12FO?
Yes. TF-FLC-XT-8715-120HYB matches the 34.5 × 120.0 mm nominal flat envelope (maximum 38.4 × 123.8 mm), 500 mm minimum bending radius, and L1(120) · PE(70) · L2(120) · [12×2.5 + 12FO] · L3(120) lay-up required by legacy RNEDAFLAT-XT / SP12-31-0117 crane reels.
What copper stranding is used in the 120 mm² phase cores of TF-FLC-XT 3×120+70+12×2.5+12FO?
608 × 0.50 mm (nominal) fine-stranded tinned copper meeting full IEC 60228 Class 5 cross-section and ≤ 0.164 Ω/km maximum DC resistance at 20 °C is used, ensuring full 290 A single-layer ampacity and flex life.
What 5-minute AC routine test voltage is applied to 8.7/15 kV TF-FLC-XT replacement cables?
24 kV AC for 5 minutes is applied to every phase core as standard with reference to DIN VDE 0250-813, and 21 kV or 30.5 kV 5-minute witnessed FAT protocols can also be executed to match terminal maintenance specifications.
Can TF-FLC-XT upgrade the 12FO (50/125) optical unit to single-mode 9/125 or 24 fibres in the same drum slot?
Yes. TEBAOFLEX can populate the central ETFE/PBT optical subunit with 12 or 24 multimode GI 50/125 µm (OM2/OM3) or bend-insensitive SM 9/125 µm (ITU-T G.657.A2) fibres while keeping maximum width within 123.8 mm.
Is TEBAOFLEX affiliated with Riken Electric Wire, and what are the MOQ and lead time for TF-FLC-XT?
No. TEBAOFLEX is an independent manufacturer referencing RIKEN and RNEDAFLAT-XT strictly for crane reel replacement compatibility; TF-FLC-XT is supplied from a 50 m MOQ in 7 to 45 working days.
TF-FLC-XT Interface Verification & Slot-Matched Size Schedule
TF-FLC-XT Key Electrical, Optical & Monospiral Drum Parameters
- Drop-in 34.5 × 120.0 mm envelope: Matches legacy RNEDAFLAT-XT / SP12-31-0117 crane BOM slot width (max. 38.4 × 123.8 mm for ≥ 125 mm monospiral flanges)
- Asymmetric 5-element flat lay-up: L1 (120) · PE (70) · L2 (120) · [12×2.5 Ctrl + 12FO Subunit] · L3 (120) aligned in one torsion-free plane
- True IEC 60228 Class 5 copper: Full 120 mm² tinned copper phase conductors (≤ 0.164 Ω/km at 20 °C, ~608 × 0.50 mm fine strands) with 3GI3 EPR insulation
- 12FO GI 50/125 or SM 9/125: Crush-buffered 12-fibre (or 24-fibre upgrade) optical unit cabled inside the 12×2.5 mm² control sub-bundle
- Direct project manufacturing: 24 kV / 5 min routine AC test (21 kV / 30.5 kV FAT options); MOQ 50 m in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 8.7/15 kV standard (Um 18 kV AC); also manufactured in 6/10 kV and 12/20 kV slot-matched builds |
| Flagship core configuration | 3x120 mm2 MV screened phase + 1x70 mm2 PE + 12x2.5 mm2 control + 12FO GI 50/125 or SM 9/125 |
| Flat profile dimensions | Nominal 34.5 x 120.0 mm (maximum 38.4 x 123.8 mm) matching 125 mm monospiral crane drum slots |
| Legacy BOM cross-reference | Engineered replacement for legacy RIKEN RNEDAFLAT-XT and crane spec SP12-31-0117 (independent TEBAOFLEX build) |
| Supply terms | MOQ 50 m with 7 to 45 working days manufacturing lead time; approval drawing confirmed before vulcanization |
| Dielectric & OTDR testing | MV cores: 24 kV AC / 5 min (21 kV or 30.5 kV FAT options); control cores: 3.5 kV / 5 min; 100% OTDR trace |
| Dynamic reeling limits | Min. bend radius 500 mm; max. pulling load 7.9 kN (working 2.6 kN); lateral load ≤ 4.9 kN/m; -35 °C to +80 °C flexing |
TF-FLC-XT 8.7/15 kV 3×120+70+12×2.5+12FO Interface & Acceptance Verification
| Engineering parameter | Legacy crane BOM interface (RNEDAFLAT-XT / SP12-31-0117) | TEBAOFLEX TF-FLC-XT-8715-120HYB verified build |
|---|---|---|
| Voltage rating U0/U (Um) | 8.7/15 kV (Um 17.5–18 kV AC, 50/60 Hz) | 8.7/15 kV (Um 18 kV AC; max. DC 13.5/27 kV) |
| Single-plane core sequence | 5-position flat lay-up: 3 MV + 1 PE + 1 control/FO bundle | L1 (120) · PE (70) · L2 (120) · [12×2.5 Ctrl + 12FO] · L3 (120) |
| Flat outer dimensions (H × W) | Fits ~125 mm monospiral drum flange slot (nom. ~34.5 × 120 mm) | Nominal 34.5 × 120.0 mm; controlled maximum 38.4 × 123.8 mm |
| Phase conductors (3 × 120 mm²) | 120 mm² flexible tinned copper | True IEC 60228 Class 5 tinned Cu (~608 × 0.50 mm strands), ≤ 0.164 Ω/km at 20 °C |
| Earth conductor (1 × 70 mm²) | 70 mm² flexible tinned copper PE | IEC 60228 Class 5 tinned Cu, ≤ 0.277 Ω/km at 20 °C, elastomer insulated |
| Control bundle (12 × 2.5 mm²) | 12 × 2.5 mm² numbered pilot/interlock cores | IEC 60228 Class 5 tinned Cu (≤ 8.21 Ω/km), EPR insulated, 3.5 kV / 5 min AC tested |
| Optical fibre subunit (12FO) | 12 × GI 50/125 µm graded-index multimode fibres | 12 × GI 50/125 µm (≤ 2.8 dB/km @ 850 nm, ≤ 1.0 dB/km @ 1300 nm) or optional SM 9/125 µm |
| MV routine 5-min AC test voltage | 21 kV to 30.5 kV / 5 min project specification dependent | 24 kV / 5 min standard (DIN VDE 0250-813); 21 kV or 30.5 kV / 5 min witnessed FAT supported |
| Dynamic reeling & tensile envelope | Bend radius ≥ 500 mm; monospiral radial winding (0°/m torsion) | Min. bend radius 500 mm; max. pull 7.9 kN / working 2.6 kN; sidewall ≤ 4.9 kN/m; 120–180 m/min |
| Outer sheath & temperature range | Heavy-duty black chloroprene rubber, 90 °C conductor | Black CR / 5GM5 polychloroprene (oil & flame resistant); 90 °C conductor, -35 °C to +80 °C flexing |
TF-FLC-XT Slot-Matched Crane Drum Replacement Schedule (8.7/15 kV & 6/10 kV)
| Model & configuration | Voltage U0/U (kV) | Nominal H x W (mm) | Max. H x W (mm) | Min. dynamic bend radius (mm) | Approx. weight (kg/km) | Max. pull / working tension (N) | Max. phase R20 (Ω/km) | 1-layer reel ampacity at 30 °C (A) | Next step |
|---|---|---|---|---|---|---|---|---|---|
| TF-FLC-XT 8.7/15 kV 3x120+1x70+12x2.5+12FO (GI 50/125) | 8.7/15 | 34.5 × 120.0 | 38.4 × 123.8 | 500 | 9,750 | 7,900 / 2,600 | 0.164 | 290 | Request this size |
| TF-FLC-XT 8.7/15 kV 3x120+1x70+12x2.5+12FO (SM 9/125) | 8.7/15 | 34.5 × 120.0 | 38.4 × 123.8 | 500 | 9,750 | 7,900 / 2,600 | 0.164 | 290 | Request this size |
| TF-FLC-XT 8.7/15 kV 3x120+1x70+12x2.5+24FO (GI 50/125 or SM 9/125) | 8.7/15 | 35.0 × 121.0 | 38.4 × 123.8 | 510 | 9,880 | 7,900 / 2,600 | 0.164 | 290 | Request this size |
| TF-FLC-XT 8.7/15 kV 3x95+1x50+12x2.5+12FO (GI 50/125 or SM 9/125) | 8.7/15 | 33.0 × 114.0 | 36.2 × 118.0 | 490 | 8,150 | 6,200 / 2,100 | 0.210 | 248 | Request this size |
| TF-FLC-XT 8.7/15 kV 3x70+1x35+12x2.5+12FO (GI 50/125 or SM 9/125) | 8.7/15 | 31.5 × 108.0 | 34.5 × 112.0 | 480 | 6,950 | 4,800 / 1,600 | 0.277 | 206 | Request this size |
| TF-FLC-XT 6/10 kV 3x120+1x70+12x2.5+12FO (GI 50/125 or SM 9/125) | 6/10 | 33.2 × 116.5 | 36.5 × 120.0 | 490 | 9,240 | 7,900 / 2,600 | 0.164 | 282 | Request this size |
Single-layer reel current ratings at 30 °C ambient are calculated with reference to DIN VDE 0298-4; apply multi-layer drum derating factors according to active stacked turns on the monospiral reel.
Before vulcanization, TEBAOFLEX issues a dimensioned cross-section approval drawing confirming exact H × W tolerances, core sequence (L1 · PE · L2 · Ctrl/FO · L3) and drum flange clearance; final values are confirmed on the quotation drawing.
Trademark & cross-reference notice: RIKEN, RNEDAFLAT and RNEDAFLAT-XT (as well as crane BOM reference SP12-31-0117) are third-party designations referenced strictly for dimensional, electrical and mechanical replacement identification on existing crane reels. TEBAOFLEX is an independent cable manufacturer and is not affiliated with or endorsed by Riken Electric Wire Co., Ltd. or Furukawa Electric.
Minimum order quantity is 50 m and manufacturing lead time is 7 to 45 working days.
ASCII part references: TF-FLC-XT-8715-120HYB; TF-FLC-XT 8.7/15 kV 3x120+1x70+12x2.5+12FO; RIKEN RNEDAFLAT-XT 3x120 + 70 + 12x2.5 + 12FO replacement; 8.7/15kV RNEDAFLAT-XT 3x120+70+12x2.5+12FO (50/125) equivalent; SP12-31-0117 crane flat reeling cable.
TF-FLC-XT Standards, Dielectric Testing & Trademark Attribution
| Standard or specification | Application |
|---|---|
| IEC 60228 Class 5 | Verified flexible tinned copper conductor stranding and maximum 20 °C DC conductor resistance (≤ 0.164 Ω/km on 120 mm², ≤ 0.277 Ω/km on 70 mm², ≤ 8.21 Ω/km on 2.5 mm²). |
| DIN VDE 0250-813 / IEC 60502-2 (reference construction) | Triple-extruded medium-voltage EPR dielectric wall thickness, semi-conductive screen strippability, partial-discharge control and 5-minute AC routine withstand testing. |
| DIN VDE 0207-20 / DIN VDE 0207-21 | 3GI3 medium-voltage EPR insulation compound and heavy-duty 5GM5 / CR polychloroprene flat outer sheath physical, tear and abrasion properties. |
| IEC 60794-1-2 / ITU-T G.651.1 & G.657.A2 | Graded-index 50/125 µm multimode and bend-insensitive 9/125 µm single-mode optical attenuation and dynamic bending verification. |
| IEC 60332-1-2 / IEC 60811-404 | Single-cable vertical flame retardance and hot mineral-oil immersion resistance on completed flat reeling sheaths. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management, MV AC dielectric routine testing and 100% OTDR inspection
IEC Webstore — IEC 60228 Class 5, IEC 60502-2 and IEC 60794-1-2 standards
DIN Media — DIN VDE 0250-813, DIN VDE 0298-4 and DIN VDE 0207 compound references
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
(N)TSFLCGEWÖU-FO / (N)TSFLCGEWOEU-LWL (3.6/6–12/20 kV) Medium-Voltage Optical & Hybrid Flat Reeling Cable
A related cable option for a different application or duty profile.
View product3PNCT, H-3PNCT, FG-H-3PNCT & F-3PNCT (3.3–6.6 kV) Round, Flat & Optical Crane Reeling Cable
A related cable option for a different application or duty profile.
View productNTSFLCGEWOEU Medium Voltage Flat Reeling Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.