High Temperature Cables TEBAOFLEX

UL 21618 Screened FEP Data Cable & 260 °C FEP/PFA Controlled-Impedance Cable

UL 21618 screened FEP high-temperature data cables (2 to 14 cores, 28 AWG to 20 AWG, -90 °C to +180/+200 °C) and FEP/PFA controlled-impedance twisted-pair bus cables (50, 75, 100 and 120 Ohm, -90 °C to +260 °C) protect RS-485, CANbus, encoder and sensor signals in extreme thermal and chemical environments.

Product information
SKU
TF-UL21618-IMP-DATA
Brand
TEBAOFLEX
Product overview

UL 21618 screened FEP data cables and FEP/PFA controlled-impedance shielded twisted-pair cables enable low-capacitance, interference-free digital communication and precision sensor telemetry across -90 °C to +200 °C (FEP) and up to +260 °C (PFA), spanning miniature 2.3 mm single-pair bus leads up to 6.4 mm 12-core instrumentation trunks.

Standard PVC, PE or polyurethane RS-485, CANbus and encoder cables suffer severe dielectric constant drift, attenuation spikes and jacket melting above +80 °C to +105 °C, or crack in -90 °C environmental test chambers and chemical vapour hoods. Because FEP and PFA maintain a virtually constant 2.1 dielectric constant from sub-zero cryogenics to +260 °C, signal propagation velocity (66 % to 80 %) and characteristic impedance (50, 75, 100 or 120 Ohm) remain locked without bit-error reflection.

Specify multi-core UL 21618 screened FEP data cable (28 AWG to 20 AWG, 600 V AWM / 375 V peak, 2,000 V test) for compact multi-channel encoders, load cells and analyzer buses up to +180/+200 °C, or specify 91 % silver-copper-braided FEP/PFA controlled-impedance twisted pairs (100 Ohm Ethernet/LVDS or 120 Ohm RS-485/CANbus) up to +260 °C (MOQ 300 m reel, 7 to 45 working days).

Explore the high-temperature wire and cable range for related configurations.

Construction

UL 21618 & FEP/PFA Data Cable Construction

Precision-twisted on tension-controlled data-twinning lines to hold tight impedance and capacitance tolerances.

Clean 2D engineering cross-section of screened FEP/PFA twisted-pair high-temperature data cable showing pearl-white FEP jacket, dense copper braid shield and four paired cores
Screened FEP/PFA data cross-section: outer fluoropolymer sheath, >= 85–91 % copper braid and paired conductors.
UL 21618 Screened FEP Data Cable & 260 °C FEP/PFA Controlled-Impedance Cable construction
ComponentMaterial and construction
1. Stranded Tinned or Silver-Plated Copper Conductors7-strand ASTM B286 tinned copper (28/7 to 20/7 AWG) on UL 21618 multi-core data cables; 19-strand silver-plated copper (26/19, 24/19, 22/19 AWG) on controlled-impedance twisted pairs.
2. Low-Capacitance FEP or PFA Dielectric InsulationThin-wall extruded FEP (VDE 6YI1, -90/+200 °C) or PFA (-90/+260 °C) primaries colour-coded per DIN 47100 or differential pair colours.
3. High-Coverage Braided Metallic EMC Shield>= 85 % tinned copper wire braid on UL 21618; 91 % optical coverage silver-plated copper braid (5–25 mOhm/m transfer impedance at 1 MHz) on controlled-impedance pairs.
4. Chemical- & Solvent-Proof FEP or PFA Outer SheathExtruded pearl-white (RAL 1013), black or translucent FEP (VDE 6YM1) or PFA outer jacket resistant to acids, halogens, bases, fuels and 10 Mrad radiation.

UL 21618 & Controlled-Impedance Code Breakdown

  • UL 21618: 600 V AWM screened multi-core FEP high-temperature data cable specification (28–20 AWG)
  • 6YI1 / 6YM1: DIN VDE 0207-6 FEP core insulation (6YI1) and FEP outer jacket (6YM1) compounds
  • FP / FA Grade: FP = FEP (-60/-90 °C to +200 °C); FA = PFA (-90 °C to +260 °C) controlled-impedance pairs
  • 50 / 75 / 100 / 120 Ohm: Characteristic differential impedance matched to RF, video, Ethernet/LVDS or RS-485/CANbus
  • CuSn / CuAg Braid: >= 85 % tinned copper (UL 21618) or 91 % silver-plated copper (controlled-impedance) EMC screen
Applications

UL 21618 RS-485, CANbus, Encoder & Chamber Applications

Built for high-temperature digital buses, environmental test chambers, semiconductor tools and oilfield surface/downhole instrumentation.

Pearl-white UL 21618 screened fluoropolymer high-temperature data cables terminated into circular metal instrumentation connectors on an environmental thermal test chamber bulkhead
High-temperature RS-485 and sensor data harnesses routed into a thermal-cycling test chamber bulkhead.
  • 120 Ohm RS-485 / Modbus / CANbus / PROFIBUS and 100 Ohm differential LVDS / industrial Ethernet links inside -90 °C to +260 °C thermal chambers.
  • Lithium-ion battery formation ovens, semiconductor bake/etch tools, vacuum furnaces and autoclave pressure/flow transmitter trunks.
  • High-temperature servo motor encoders, resolver feedback, strain-gauge load cells and multi-channel analytical chromatographs (UL 21618).
  • Downhole tool string interconnects, turbine test-cell telemetry and chemical-plant hazardous-fume analyzer networks.

UL 21618 & FEP/PFA Data vs LIHCH FE180 vs PAS 5308

UL 21618 Screened FEP Data vs 260 °C FEP/PFA Controlled-Impedance vs LIHCH FE180 vs PAS 5308
Data / Signal CableTemp. EnvelopeImpedance & CapacitanceTarget Protocol & Environment
UL 21618 Screened FEP (this page)-90 °C to +180 / +200 °CLow-cap (~55 pF/m) multi-core encoder/sensor busMulti-channel encoders, load cells & chemical/oven PLC I/O
FEP/PFA Controlled-Impedance (this page)-90 °C to +200 °C (FEP) / +260 °C (PFA)50, 75, 100 or 120 Ohm (+/- 10 %), 91 % CuAg braidHigh-temp RS-485, CANbus, Modbus, LVDS & chamber Ethernet
LIHCH FE180 (ID 8033)-30 °C to +90 °C (FE180 fire)Fire-survival 300 V building alarm & PA/VA loopTunnels, hospitals & metro fire-alarm circuits (not +200 °C ambient)
BS/PAS 5308 Part 1 XLPE (ID 4278)-40 °C to +90 °CCollective/individual foil process 4–20 mA trunkAmbient petrochemical plant trays below +90 °C

Select 120 Ohm PFA twisted pair for RS-485 / CANbus above +200 °C up to +260 °C; select UL 21618 for multi-core 28–20 AWG sensor/encoder looms.

UL 21618 & Controlled-Impedance Data Cable RFQ Checklist

  • Cable architecture: multi-core UL 21618 screened FEP (2–14 cores) or controlled-impedance twisted pair (50, 75, 100 or 120 Ohm).
  • Polymer temperature grade: FEP (-90 °C to +180/+200 °C) or PFA (-90 °C to +260 °C).
  • Conductor AWG gauge (28, 26, 24, 22 or 20 AWG) and pair/core count.
  • Outer sheath colour (pearl-white RAL 1013, black or translucent) and total meterage (MOQ 300 m / 305 m reel, 7 to 45 working days).

Related selection resources

UL 21618 Screened FEP & 260 °C Data Cable FAQ

Why use FEP/PFA controlled-impedance cable instead of standard RS-485 or CANbus cable above +125 °C?

2.1 constant relative permittivity across -90 °C to +260 °C keeps FEP/PFA characteristic impedance locked at 100 Ohm or 120 Ohm (+/- 10 %), whereas PE or PVC foam dielectrics soften, shift impedance and cause packet loss above +80 °C to +105 °C.

What is the temperature rating of UL 21618 screened FEP data cable?

-90 °C to +180 °C continuous (+200 °C short-term) under DIN VDE thermal criteria and +150 °C / 600 V under UL 758 Style 21618 geometry.

When should I choose PFA over FEP for controlled-impedance twisted-pair data cables?

Above +200 °C up to +260 °C continuous ambient temperature (or down to -90 °C dynamic thermal shock), specify the FA-grade PFA insulation and PFA outer jacket with 19-strand silver-plated or nickel-plated copper.

How small is the outer diameter of UL 21618 screened FEP sensor cable?

2.4 mm nominal outer diameter on 2x28 AWG and just 3.3 mm on 4x24 AWG allow UL 21618 to route through miniature M8/M12 sensor glands and robotic wrists.

What is the minimum order quantity and lead time for UL 21618 and FEP/PFA data cables?

300 m or 305 m (1,000 ft) minimum order per specification on continuous factory reels, with a 7 to 45 working days production lead time.

Specifications

UL 21618 & 50/75/100/120 Ohm Twisted-Pair Schedules

UL 21618 & FEP/PFA Impedance, Capacitance & Reel Summary

  • UL 21618 multi-core screened FEP: 2 to 14 cores (28/7 to 20/7 AWG tinned copper) with VDE 6YI1 FEP primaries, >= 85 % tinned copper braid and RAL 1013 white FEP jacket (2.4 to 6.4 mm OD)
  • 50 / 75 / 100 / 120 Ohm twisted pairs: Controlled-impedance 19-strand silver-plated copper twisted pairs in FEP (-60/+200 °C) or PFA (-90/+260 °C) with 91 % silver-copper braid
  • Frequency-stable low permittivity: FEP and PFA relative permittivity (2.1) stays flat across temperature and MHz frequency, keeping working capacitance down to 40–90 pF/m
  • Cryogenic -90 °C to +260 °C duty: Reliable high-speed digital bus, LVDS, RS-422/RS-485, CANbus and encoder telemetry from liquid-nitrogen cold boxes to +260 °C chambers
  • 300 m / 305 m factory reel supply: Supplied in 300 m or 305 m continuous melt-extruded reels with 7 to 45 working days manufacturing lead time
UL 21618 Screened FEP Data Cable & 260 °C FEP/PFA Controlled-Impedance Cable technical data
ParameterValue
Rated voltage600 V AWM / 375 V peak (2000 V AC core-to-core and core-to-screen test) on UL 21618; up to 600 V max operating voltage on FEP/PFA twisted pairs
Conductor and pair configurations2 to 14 cores in 28 AWG to 20 AWG (UL 21618) plus 1 to 4 twisted pairs in 26, 24 and 22 AWG at 50, 75, 100 or 120 Ohm characteristic impedance
Dielectric, screen and sheathExtruded FEP (-90 C to +200 C) or PFA (-90 C to +260 C) with 85% tinned copper or 91% silver-plated copper braid shield
Capacitance, attenuation and bend radius40 to 90 pF/m working capacitance, 4 to 5 dB/100 m max attenuation at 20 MHz (100/120 Ohm), and 7.5x OD minimum bending radius
Standard put-up and lead time300 m or 305 m minimum order continuous factory reels delivered in 7 to 45 working days
Standards compliance noteEngineered to UL 758 AWM Style 21618 I/II A/B (FT1/FT2) and DIN 47100 colour-code specifications (third-party UL/CSA mark is not claimed)
Oil, radiation and chemical resistancePasses UL 758 80 C 80-day oil immersion criteria, tolerates up to 10^7 cJ/kg radiation, and resists acids, bases and chlorinated solvents

UL 21618 Screened FEP Data Cable Schedule (28–20 AWG)

Screened FEP High-Temp Data Cable Engineered to UL 21618 (-90 °C to +180/+200 °C, 600 V AWM) — Dimensional & Weight Schedule
Model & Core SizeStrand Ø (mm)Nom. Outer Ø (mm)Copper Index (kg/km)Approx. Weight (kg/km)Test Voltage (Core/Screen)Standard Reel MOQNext step
UL 21618 2x28 AWG (7w)0.1272.48.812.32,000 V AC300 m / 305 mRequest this size
UL 21618 3x28 AWG (7w)0.1272.69.713.92,000 V AC300 m / 305 mRequest this size
UL 21618 4x28 AWG (7w)0.1272.813.817.82,000 V AC300 m / 305 mRequest this size
UL 21618 7x28 AWG (7w)0.1273.216.623.32,000 V AC300 m / 305 mRequest this size
UL 21618 12x28 AWG (7w)0.1274.027.435.92,000 V AC300 m / 305 mRequest this size
UL 21618 2x26 AWG (7w)0.1602.713.016.12,000 V AC300 m / 305 mRequest this size
UL 21618 4x26 AWG (7w)0.1603.115.920.62,000 V AC300 m / 305 mRequest this size
UL 21618 7x26 AWG (7w)0.1603.520.228.12,000 V AC300 m / 305 mRequest this size
UL 21618 2x24 AWG (7w)0.2033.114.518.82,000 V AC300 m / 305 mRequest this size
UL 21618 3x24 AWG (7w)0.2033.116.621.62,000 V AC300 m / 305 mRequest this size
UL 21618 4x24 AWG (7w)0.2033.318.425.02,000 V AC300 m / 305 mRequest this size
UL 21618 7x24 AWG (7w)0.2034.025.236.82,000 V AC300 m / 305 mRequest this size
UL 21618 10x24 AWG (7w)0.2035.036.953.42,000 V AC300 m / 305 mRequest this size
UL 21618 2x22 AWG (7w)0.2543.317.121.92,000 V AC300 m / 305 mRequest this size
UL 21618 4x22 AWG (7w)0.2543.827.433.42,000 V AC300 m / 305 mRequest this size
UL 21618 7x22 AWG (7w)0.2544.437.849.42,000 V AC300 m / 305 mRequest this size
UL 21618 12x22 AWG (7w)0.2545.860.380.22,000 V AC300 m / 305 mRequest this size
UL 21618 2x20 AWG (7w)0.3203.724.629.32,000 V AC300 m / 305 mRequest this size
UL 21618 4x20 AWG (7w)0.3204.335.644.52,000 V AC300 m / 305 mRequest this size
UL 21618 10x20 AWG (7w)0.3206.475.495.12,000 V AC300 m / 305 mRequest this size

FEP/PFA 50, 75, 100 & 120 Ohm Controlled-Impedance Twisted-Pair Schedule

FEP (-60/+200 °C) & PFA (-90/+260 °C) Controlled-Impedance Shielded Twisted-Pair Data Bus Schedule (50 / 75 / 100 / 120 Ohm)
Model, Impedance & GaugeSPC StrandingImpedance ToleranceAttenuation @ 20 MHzNom. Outer Ø (mm)Approx. Weight (kg/km)Standard Reel MOQNext step
FEP/PFA 50 Ohm 1x2x26 AWG19x0.10 SPC50 +/- 5 Ohm30 dB/100 m2.313.0300 m / 305 mRequest this size
FEP/PFA 50 Ohm 1x2x24 AWG19x0.13 SPC50 +/- 5 Ohm30 dB/100 m2.716.1300 m / 305 mRequest this size
FEP/PFA 75 Ohm 1x2x26 AWG19x0.10 SPC75 +/- 8 Ohm15 dB/100 m2.815.4300 m / 305 mRequest this size
FEP/PFA 75 Ohm 1x2x24 AWG19x0.13 SPC75 +/- 8 Ohm15 dB/100 m3.421.5300 m / 305 mRequest this size
FEP/PFA 100 Ohm 1x2x26 AWG19x0.10 SPC100 +/- 10 Ohm5 dB/100 m3.723.3300 m / 305 mRequest this size
FEP/PFA 100 Ohm 1x2x24 AWG19x0.13 SPC100 +/- 10 Ohm5 dB/100 m4.430.9300 m / 305 mRequest this size
FEP/PFA 100 Ohm 2x2x24 AWG19x0.13 SPC100 +/- 10 Ohm5 dB/100 m6.254.0300 m / 305 mRequest this size
FEP/PFA 120 Ohm 1x2x26 AWG19x0.10 SPC120 +/- 12 Ohm4 dB/100 m4.430.9300 m / 305 mRequest this size
FEP/PFA 120 Ohm 1x2x24 AWG19x0.13 SPC120 +/- 12 Ohm4 dB/100 m5.351.2300 m / 305 mRequest this size
FEP/PFA 120 Ohm 1x2x22 AWG19x0.16 SPC120 +/- 12 Ohm4 dB/100 m6.570.3300 m / 305 mRequest this size

ASCII part references for BOM and ERP entry: TF-UL21618-4X24AWG, TF-UL21618-7X24AWG, TF-UL21618-4X22AWG, TF-UL21618-12X22AWG, TF-IMP100-FEP-1P24AWG, TF-IMP120-PFA-1P24AWG, TF-IMP120-PFA-1P22AWG.

Specify FP-grade FEP (-60 °C to +200 °C) or FA-grade PFA (-90 °C to +260 °C) when ordering controlled-impedance 50 / 75 / 100 / 120 Ohm twisted pairs.

Standards

UL 21618, DIN 47100 & RS-485/CANbus Reference Standards

UL 21618 Screened FEP Data Cable & 260 °C FEP/PFA Controlled-Impedance Cable standards and test references
Standard or specificationApplication
UL 758 Style 21618 (Engineered to Dimensional & Electrical Spec)600 V AWM / 150 °C (VDE -90/+180 °C, +200 °C peak) screened FEP multi-conductor data cable with FT1/FT2 flame performance (third-party UL/CSA mark is not claimed).
DIN 47100 & TIA/EIA-485 (RS-485) / ISO 11898 (CANbus)Colour coding for multi-core electronic data cables and 100 Ohm / 120 Ohm differential characteristic impedance matching.
IEC 60332-1-2Flame-retardant self-extinguishing behaviour on single vertical screened fluoropolymer data cables.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and impedance/spark test verification

UL 758 — Standard for Appliance Wiring Material

IEC 60332-1-2 — Vertical flame propagation test

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.