UL 21618 Screened FEP Data Cable & 260 °C FEP/PFA Controlled-Impedance Cable
UL 21618 screened FEP high-temperature data cables (2 to 14 cores, 28 AWG to 20 AWG, -90 °C to +180/+200 °C) and FEP/PFA controlled-impedance twisted-pair bus cables (50, 75, 100 and 120 Ohm, -90 °C to +260 °C) protect RS-485, CANbus, encoder and sensor signals in extreme thermal and chemical environments.
UL 21618 screened FEP data cables and FEP/PFA controlled-impedance shielded twisted-pair cables enable low-capacitance, interference-free digital communication and precision sensor telemetry across -90 °C to +200 °C (FEP) and up to +260 °C (PFA), spanning miniature 2.3 mm single-pair bus leads up to 6.4 mm 12-core instrumentation trunks.
Standard PVC, PE or polyurethane RS-485, CANbus and encoder cables suffer severe dielectric constant drift, attenuation spikes and jacket melting above +80 °C to +105 °C, or crack in -90 °C environmental test chambers and chemical vapour hoods. Because FEP and PFA maintain a virtually constant 2.1 dielectric constant from sub-zero cryogenics to +260 °C, signal propagation velocity (66 % to 80 %) and characteristic impedance (50, 75, 100 or 120 Ohm) remain locked without bit-error reflection.
Specify multi-core UL 21618 screened FEP data cable (28 AWG to 20 AWG, 600 V AWM / 375 V peak, 2,000 V test) for compact multi-channel encoders, load cells and analyzer buses up to +180/+200 °C, or specify 91 % silver-copper-braided FEP/PFA controlled-impedance twisted pairs (100 Ohm Ethernet/LVDS or 120 Ohm RS-485/CANbus) up to +260 °C (MOQ 300 m reel, 7 to 45 working days).
Explore the high-temperature wire and cable range for related configurations.
UL 21618 & FEP/PFA Data Cable Construction
Precision-twisted on tension-controlled data-twinning lines to hold tight impedance and capacitance tolerances.

| Component | Material and construction |
|---|---|
| 1. Stranded Tinned or Silver-Plated Copper Conductors | 7-strand ASTM B286 tinned copper (28/7 to 20/7 AWG) on UL 21618 multi-core data cables; 19-strand silver-plated copper (26/19, 24/19, 22/19 AWG) on controlled-impedance twisted pairs. |
| 2. Low-Capacitance FEP or PFA Dielectric Insulation | Thin-wall extruded FEP (VDE 6YI1, -90/+200 °C) or PFA (-90/+260 °C) primaries colour-coded per DIN 47100 or differential pair colours. |
| 3. High-Coverage Braided Metallic EMC Shield | >= 85 % tinned copper wire braid on UL 21618; 91 % optical coverage silver-plated copper braid (5–25 mOhm/m transfer impedance at 1 MHz) on controlled-impedance pairs. |
| 4. Chemical- & Solvent-Proof FEP or PFA Outer Sheath | Extruded pearl-white (RAL 1013), black or translucent FEP (VDE 6YM1) or PFA outer jacket resistant to acids, halogens, bases, fuels and 10 Mrad radiation. |
UL 21618 & Controlled-Impedance Code Breakdown
- UL 21618: 600 V AWM screened multi-core FEP high-temperature data cable specification (28–20 AWG)
- 6YI1 / 6YM1: DIN VDE 0207-6 FEP core insulation (6YI1) and FEP outer jacket (6YM1) compounds
- FP / FA Grade: FP = FEP (-60/-90 °C to +200 °C); FA = PFA (-90 °C to +260 °C) controlled-impedance pairs
- 50 / 75 / 100 / 120 Ohm: Characteristic differential impedance matched to RF, video, Ethernet/LVDS or RS-485/CANbus
- CuSn / CuAg Braid: >= 85 % tinned copper (UL 21618) or 91 % silver-plated copper (controlled-impedance) EMC screen
UL 21618 RS-485, CANbus, Encoder & Chamber Applications
Built for high-temperature digital buses, environmental test chambers, semiconductor tools and oilfield surface/downhole instrumentation.

- 120 Ohm RS-485 / Modbus / CANbus / PROFIBUS and 100 Ohm differential LVDS / industrial Ethernet links inside -90 °C to +260 °C thermal chambers.
- Lithium-ion battery formation ovens, semiconductor bake/etch tools, vacuum furnaces and autoclave pressure/flow transmitter trunks.
- High-temperature servo motor encoders, resolver feedback, strain-gauge load cells and multi-channel analytical chromatographs (UL 21618).
- Downhole tool string interconnects, turbine test-cell telemetry and chemical-plant hazardous-fume analyzer networks.
UL 21618 & FEP/PFA Data vs LIHCH FE180 vs PAS 5308
| Data / Signal Cable | Temp. Envelope | Impedance & Capacitance | Target Protocol & Environment |
|---|---|---|---|
| UL 21618 Screened FEP (this page) | -90 °C to +180 / +200 °C | Low-cap (~55 pF/m) multi-core encoder/sensor bus | Multi-channel encoders, load cells & chemical/oven PLC I/O |
| FEP/PFA Controlled-Impedance (this page) | -90 °C to +200 °C (FEP) / +260 °C (PFA) | 50, 75, 100 or 120 Ohm (+/- 10 %), 91 % CuAg braid | High-temp RS-485, CANbus, Modbus, LVDS & chamber Ethernet |
| LIHCH FE180 (ID 8033) | -30 °C to +90 °C (FE180 fire) | Fire-survival 300 V building alarm & PA/VA loop | Tunnels, hospitals & metro fire-alarm circuits (not +200 °C ambient) |
| BS/PAS 5308 Part 1 XLPE (ID 4278) | -40 °C to +90 °C | Collective/individual foil process 4–20 mA trunk | Ambient petrochemical plant trays below +90 °C |
Select 120 Ohm PFA twisted pair for RS-485 / CANbus above +200 °C up to +260 °C; select UL 21618 for multi-core 28–20 AWG sensor/encoder looms.
UL 21618 & Controlled-Impedance Data Cable RFQ Checklist
- Cable architecture: multi-core UL 21618 screened FEP (2–14 cores) or controlled-impedance twisted pair (50, 75, 100 or 120 Ohm).
- Polymer temperature grade: FEP (-90 °C to +180/+200 °C) or PFA (-90 °C to +260 °C).
- Conductor AWG gauge (28, 26, 24, 22 or 20 AWG) and pair/core count.
- Outer sheath colour (pearl-white RAL 1013, black or translucent) and total meterage (MOQ 300 m / 305 m reel, 7 to 45 working days).
Related selection resources
- Browse all High-Temperature Fluoropolymer & Sensor Cables
- Compare 200 °C Fluoropolymer RTD Sensor Cable Configurations
- Engineering guide: Braided shield transfer impedance and coverage
- Instrumentation cable screening and pair twisting fundamentals
- Compare FEP vs PFA vs PTFE vs ETFE temperature ratings
UL 21618 Screened FEP & 260 °C Data Cable FAQ
Why use FEP/PFA controlled-impedance cable instead of standard RS-485 or CANbus cable above +125 °C?
2.1 constant relative permittivity across -90 °C to +260 °C keeps FEP/PFA characteristic impedance locked at 100 Ohm or 120 Ohm (+/- 10 %), whereas PE or PVC foam dielectrics soften, shift impedance and cause packet loss above +80 °C to +105 °C.
What is the temperature rating of UL 21618 screened FEP data cable?
-90 °C to +180 °C continuous (+200 °C short-term) under DIN VDE thermal criteria and +150 °C / 600 V under UL 758 Style 21618 geometry.
When should I choose PFA over FEP for controlled-impedance twisted-pair data cables?
Above +200 °C up to +260 °C continuous ambient temperature (or down to -90 °C dynamic thermal shock), specify the FA-grade PFA insulation and PFA outer jacket with 19-strand silver-plated or nickel-plated copper.
How small is the outer diameter of UL 21618 screened FEP sensor cable?
2.4 mm nominal outer diameter on 2x28 AWG and just 3.3 mm on 4x24 AWG allow UL 21618 to route through miniature M8/M12 sensor glands and robotic wrists.
What is the minimum order quantity and lead time for UL 21618 and FEP/PFA data cables?
300 m or 305 m (1,000 ft) minimum order per specification on continuous factory reels, with a 7 to 45 working days production lead time.
UL 21618 & 50/75/100/120 Ohm Twisted-Pair Schedules
UL 21618 & FEP/PFA Impedance, Capacitance & Reel Summary
- UL 21618 multi-core screened FEP: 2 to 14 cores (28/7 to 20/7 AWG tinned copper) with VDE 6YI1 FEP primaries, >= 85 % tinned copper braid and RAL 1013 white FEP jacket (2.4 to 6.4 mm OD)
- 50 / 75 / 100 / 120 Ohm twisted pairs: Controlled-impedance 19-strand silver-plated copper twisted pairs in FEP (-60/+200 °C) or PFA (-90/+260 °C) with 91 % silver-copper braid
- Frequency-stable low permittivity: FEP and PFA relative permittivity (2.1) stays flat across temperature and MHz frequency, keeping working capacitance down to 40–90 pF/m
- Cryogenic -90 °C to +260 °C duty: Reliable high-speed digital bus, LVDS, RS-422/RS-485, CANbus and encoder telemetry from liquid-nitrogen cold boxes to +260 °C chambers
- 300 m / 305 m factory reel supply: Supplied in 300 m or 305 m continuous melt-extruded reels with 7 to 45 working days manufacturing lead time
| Parameter | Value |
|---|---|
| Rated voltage | 600 V AWM / 375 V peak (2000 V AC core-to-core and core-to-screen test) on UL 21618; up to 600 V max operating voltage on FEP/PFA twisted pairs |
| Conductor and pair configurations | 2 to 14 cores in 28 AWG to 20 AWG (UL 21618) plus 1 to 4 twisted pairs in 26, 24 and 22 AWG at 50, 75, 100 or 120 Ohm characteristic impedance |
| Dielectric, screen and sheath | Extruded FEP (-90 C to +200 C) or PFA (-90 C to +260 C) with 85% tinned copper or 91% silver-plated copper braid shield |
| Capacitance, attenuation and bend radius | 40 to 90 pF/m working capacitance, 4 to 5 dB/100 m max attenuation at 20 MHz (100/120 Ohm), and 7.5x OD minimum bending radius |
| Standard put-up and lead time | 300 m or 305 m minimum order continuous factory reels delivered in 7 to 45 working days |
| Standards compliance note | Engineered to UL 758 AWM Style 21618 I/II A/B (FT1/FT2) and DIN 47100 colour-code specifications (third-party UL/CSA mark is not claimed) |
| Oil, radiation and chemical resistance | Passes UL 758 80 C 80-day oil immersion criteria, tolerates up to 10^7 cJ/kg radiation, and resists acids, bases and chlorinated solvents |
UL 21618 Screened FEP Data Cable Schedule (28–20 AWG)
| Model & Core Size | Strand Ø (mm) | Nom. Outer Ø (mm) | Copper Index (kg/km) | Approx. Weight (kg/km) | Test Voltage (Core/Screen) | Standard Reel MOQ | Next step |
|---|---|---|---|---|---|---|---|
| UL 21618 2x28 AWG (7w) | 0.127 | 2.4 | 8.8 | 12.3 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 3x28 AWG (7w) | 0.127 | 2.6 | 9.7 | 13.9 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 4x28 AWG (7w) | 0.127 | 2.8 | 13.8 | 17.8 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 7x28 AWG (7w) | 0.127 | 3.2 | 16.6 | 23.3 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 12x28 AWG (7w) | 0.127 | 4.0 | 27.4 | 35.9 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 2x26 AWG (7w) | 0.160 | 2.7 | 13.0 | 16.1 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 4x26 AWG (7w) | 0.160 | 3.1 | 15.9 | 20.6 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 7x26 AWG (7w) | 0.160 | 3.5 | 20.2 | 28.1 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 2x24 AWG (7w) | 0.203 | 3.1 | 14.5 | 18.8 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 3x24 AWG (7w) | 0.203 | 3.1 | 16.6 | 21.6 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 4x24 AWG (7w) | 0.203 | 3.3 | 18.4 | 25.0 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 7x24 AWG (7w) | 0.203 | 4.0 | 25.2 | 36.8 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 10x24 AWG (7w) | 0.203 | 5.0 | 36.9 | 53.4 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 2x22 AWG (7w) | 0.254 | 3.3 | 17.1 | 21.9 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 4x22 AWG (7w) | 0.254 | 3.8 | 27.4 | 33.4 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 7x22 AWG (7w) | 0.254 | 4.4 | 37.8 | 49.4 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 12x22 AWG (7w) | 0.254 | 5.8 | 60.3 | 80.2 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 2x20 AWG (7w) | 0.320 | 3.7 | 24.6 | 29.3 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 4x20 AWG (7w) | 0.320 | 4.3 | 35.6 | 44.5 | 2,000 V AC | 300 m / 305 m | Request this size |
| UL 21618 10x20 AWG (7w) | 0.320 | 6.4 | 75.4 | 95.1 | 2,000 V AC | 300 m / 305 m | Request this size |
FEP/PFA 50, 75, 100 & 120 Ohm Controlled-Impedance Twisted-Pair Schedule
| Model, Impedance & Gauge | SPC Stranding | Impedance Tolerance | Attenuation @ 20 MHz | Nom. Outer Ø (mm) | Approx. Weight (kg/km) | Standard Reel MOQ | Next step |
|---|---|---|---|---|---|---|---|
| FEP/PFA 50 Ohm 1x2x26 AWG | 19x0.10 SPC | 50 +/- 5 Ohm | 30 dB/100 m | 2.3 | 13.0 | 300 m / 305 m | Request this size |
| FEP/PFA 50 Ohm 1x2x24 AWG | 19x0.13 SPC | 50 +/- 5 Ohm | 30 dB/100 m | 2.7 | 16.1 | 300 m / 305 m | Request this size |
| FEP/PFA 75 Ohm 1x2x26 AWG | 19x0.10 SPC | 75 +/- 8 Ohm | 15 dB/100 m | 2.8 | 15.4 | 300 m / 305 m | Request this size |
| FEP/PFA 75 Ohm 1x2x24 AWG | 19x0.13 SPC | 75 +/- 8 Ohm | 15 dB/100 m | 3.4 | 21.5 | 300 m / 305 m | Request this size |
| FEP/PFA 100 Ohm 1x2x26 AWG | 19x0.10 SPC | 100 +/- 10 Ohm | 5 dB/100 m | 3.7 | 23.3 | 300 m / 305 m | Request this size |
| FEP/PFA 100 Ohm 1x2x24 AWG | 19x0.13 SPC | 100 +/- 10 Ohm | 5 dB/100 m | 4.4 | 30.9 | 300 m / 305 m | Request this size |
| FEP/PFA 100 Ohm 2x2x24 AWG | 19x0.13 SPC | 100 +/- 10 Ohm | 5 dB/100 m | 6.2 | 54.0 | 300 m / 305 m | Request this size |
| FEP/PFA 120 Ohm 1x2x26 AWG | 19x0.10 SPC | 120 +/- 12 Ohm | 4 dB/100 m | 4.4 | 30.9 | 300 m / 305 m | Request this size |
| FEP/PFA 120 Ohm 1x2x24 AWG | 19x0.13 SPC | 120 +/- 12 Ohm | 4 dB/100 m | 5.3 | 51.2 | 300 m / 305 m | Request this size |
| FEP/PFA 120 Ohm 1x2x22 AWG | 19x0.16 SPC | 120 +/- 12 Ohm | 4 dB/100 m | 6.5 | 70.3 | 300 m / 305 m | Request this size |
ASCII part references for BOM and ERP entry: TF-UL21618-4X24AWG, TF-UL21618-7X24AWG, TF-UL21618-4X22AWG, TF-UL21618-12X22AWG, TF-IMP100-FEP-1P24AWG, TF-IMP120-PFA-1P24AWG, TF-IMP120-PFA-1P22AWG.
Specify FP-grade FEP (-60 °C to +200 °C) or FA-grade PFA (-90 °C to +260 °C) when ordering controlled-impedance 50 / 75 / 100 / 120 Ohm twisted pairs.
UL 21618, DIN 47100 & RS-485/CANbus Reference Standards
| Standard or specification | Application |
|---|---|
| UL 758 Style 21618 (Engineered to Dimensional & Electrical Spec) | 600 V AWM / 150 °C (VDE -90/+180 °C, +200 °C peak) screened FEP multi-conductor data cable with FT1/FT2 flame performance (third-party UL/CSA mark is not claimed). |
| DIN 47100 & TIA/EIA-485 (RS-485) / ISO 11898 (CANbus) | Colour coding for multi-core electronic data cables and 100 Ohm / 120 Ohm differential characteristic impedance matching. |
| IEC 60332-1-2 | Flame-retardant self-extinguishing behaviour on single vertical screened fluoropolymer data cables. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and impedance/spark test verification
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Chem-Gard 200 RTD Cable 40551 / 40552 Alternative — TEBAOFLEX Specification Review
A related cable option for a different application or duty profile.
View productFFCT Fluoroplastic Cable 600 V 200°C
A related cable option for a different application or duty profile.
View productFEP Hook-Up Wire — UL 1330, UL 1331, UL 1332 & UL 1333 Wire (150–200 °C, 300/600 V)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.