Marine & Offshore Cables TEBAOFLEX

TF-HULL Ship Hull Biofouling Cleaning & Grooming Robot Buoyant Hybrid Tether Cable (8GAX50, 12GAX49, 24XM308 & 13XM469 Series)

TF-HULL (TF-HULL-TETHER) is a neutrally or slightly positively buoyant electro-optical hybrid tether cable for in-water ship hull biofouling cleaning, proactive hull grooming and cavitation jetting robots from 3 kW to 75 kW. Rated 400–1,000 V DC and 0.6/1 kV AC with Class 5/6 copper or lightweight aluminum-alloy cores, stainless-steel tube fibers or subsea Cat 6, aramid/LCP tensile braid and barnacle-cut-resistant Shore 94A PUR or low-drag UV-LDPE jackets.

Product information
SKU
TF-HULL-TETHER
Brand
TEBAOFLEX
Product overview

TF-HULL ship hull biofouling cleaning robot tether cables transmit 3 kW to 75 kW (400–1,000 V DC or 0.6/1 kV AC) thruster/brush/cavitation-pump power, gigabit optical or subsea Cat 6 video telemetry, and optional polyamide fluid-sampling lines across Ø 11.3 mm to Ø 39.25 mm buoyant cross-sections with 5 kN to 70 kN minimum breaking load.

In-water hull cleaning (IWHC) and proactive hull-grooming vehicles operate in the harshest shallow subsea zone: murky 0.5–30 m port anchorages with 1–3 knot tidal currents, sharp calcareous barnacle and tubeworm encrustation along bilge keels and sea chests, oily harbor slicks, and exposed ship propellers. Standard sinking ROV umbilicals drag into seabed silt or snag rudder horns, whereas soft TPR jackets slice open on barnacle edges and wick seawater longitudinally into vehicle junction boxes. TF-HULL combines closed-cell syntactic buoyancy layers, dry swelling water-blocking tapes/compounds, high-modulus aramid or liquid-crystal-polymer (LCP) contra-helical braids, and cut-resistant Shore 94A matte PUR (including high-visibility Neon Yellow or Fluorescent Orange for turbid harbor water) or low-drag UV-LDPE outer sheaths.

Select from six TF-HULL power-and-telemetry tiers (TF-HULL-3K through TF-HULL-75K) or specify direct dimensional equivalents to European marine tether references 8GAX50, 12GAX49, 13XM469, 24XM308, 3GAX47, 12GAX64, 12XM463 and 12XM388. Supplied as continuous bulk cable on wooden reels with heat-shrink end caps from 50 m MOQ in 7 to 45 working days.

Explore the marine, offshore and shipboard cable range for related configurations.

Construction

TF-HULL Biofouling Cleaning Robot Tether Construction

Engineered with longitudinally water-blocked power, optical and optional fluid-sampling elements, balanced synthetic fiber strength members and barnacle-resistant buoyant outer sheaths.

Clean 2D circular engineering cross-section of TF-HULL buoyant hull-cleaning ROV tether showing neon-yellow outer PUR jacket, golden aramid tensile braid, white syntactic foam ring, four insulated power cores, stainless-steel FIMT optical unit and polyamide tube
Cross-section: radial syntactic flotation and longitudinal water-blocking surrounding power, stainless-steel optical tube and fluid-sampling elements.
TF-HULL Ship Hull Biofouling Cleaning & Grooming Robot Buoyant Hybrid Tether Cable (8GAX50, 12GAX49, 24XM308 & 13XM469 Series) construction
ComponentMaterial and construction
1. Power Conductors (Tinned/Bare Class 5/6 Copper or Lightweight Aluminum Alloy)IEC 60228 Class 5/6 flexible tinned or bare copper conductors (1.5 mm² to 25 mm²) insulated with thin-wall crosslinked HDPE, XLPE, PP or ETFE; lightweight aluminum-alloy power cores available on weight-critical 24XM308 / 12GAX64 builds.
2. Optical & High-Speed Data Elements (FIMT Fiber or Subsea Cat 6)4 to 12 single-mode (ITU-T G.657.A2) or multimode (50/125 OM3) fibers housed inside a crush-resistant gel-filled stainless-steel tube (FIMT) with PE jacket, or 4×2×24 AWG 100-ohm shielded subsea Cat 6 data core.
3. Optional Polyamide (PA) Sampling / Flushing Micro-Tube & Water-BlockingOptional chemical-resistant polyamide tube (for antifouling biocide/effluent monitoring or pressure sensor reference) laid up with solid/silicone water-blocking compound and super-absorbent swelling tapes.
4. Closed-Cell Buoyancy Layer & Aramid / LCP Tensile BraidHydrostatic pressure-rated cellular polyolefin or syntactic foam inner sheath paired with torque-balanced high-modulus aramid or liquid-crystal-polymer (LCP) fiber braid (5 kN to 70 kN breaking load).
5. Barnacle-Cut & Hydrocarbon-Resistant Outer SheathHydrolysis- and UV-stabilized Shore 94A matte polyether PUR (Neon Yellow, Fluorescent Orange or Black; oil/diesel/crude resistant on heavy grades) or low-friction slick UV-LDPE sheath.

TF-HULL Power Tiers & GAX / XM Reference Code Breakdown

  • TF-HULL-3K .. 75K: TEBAOFLEX hull-cleaning ROV hybrid tether sized by vehicle shaft/thruster power (3 kW grooming up to 75 kW heavy cavitation/brush)
  • 8GAX50 / 12GAX49 / 3GAX47: Compact mini-ROV (11.3 mm), slick LDPE abrasion-resistant (17.0 mm) and 70 kN long-range (23.0 mm) neutrally buoyant tether equivalents
  • 24XM308 / 12GAX64: Weight-balanced tinned-copper + aluminum-alloy electro-optical (22.7 mm) and subsea Cat 6 (31.1 mm) neutral tether builds
  • 13XM469 / 12XM463 / 12XM388: High-power hull-cleaning ROV buoyant hybrid umbilicals (17.0 mm PA-tube, 33.6 mm FR-PUR and 39.25 mm crude/diesel-resistant PUR)
  • -NY / -FO / -LDPE: Outer jacket options: turbid-water Neon Yellow PUR (-NY), Fluorescent Orange PUR (-FO), or low-drag UV-LDPE (-LDPE)
Applications

TF-HULL In-Water Hull Cleaning, Grooming & Port ROV Duty

Built for commercial port hull-grooming drones, high-power cavitation/brush IWHC vehicles, biofouling capture ROVs and long-reach hull inspection.

Subsea ship hull biofouling cleaning ROV grooming barnacle and algae growth along a submerged cargo vessel hull plate while trailing a floating neon-yellow TF-HULL hybrid tether cable clear of the propeller
In-water hull cleaning (IWHC) robot operating at berth with a slightly buoyant TF-HULL hybrid tether floating clear of hull appendages.
  • Proactive ship hull grooming robots and magnetic/suction-adhesion slime-wiping vehicles operating at berth or anchorage.
  • High-power rotary brush and hydrodynamic cavitation hull-cleaning ROVs (15–75 kW) with effluent filtration and propeller polishing.
  • Sea-chest grating, bulbous bow, thruster tunnel, rudder stock and niche-area biofouling inspection and cleaning vehicles.
  • Turbid-water port security, submerged hull contraband sweeps and long-range dam/outfall tunnel inspection ROVs (up to 7,000 m single length on 3GAX47 grade).

TF-HULL Buoyant Tether vs Magnetic Crawler & Hydraulic Umbilicals

TF-HULL Biofouling Cleaning Robot Tether vs TF-MCR Magnetic Crawler Umbilical vs TF-HULLUMB Hydraulic Hose Umbilical vs DLRB/GAX Mini Tether
Umbilical / Tether FamilyPrimary Vehicle & DutyWeight / Buoyancy ProfileBest Engineering Fit
TF-HULL Tether (this page)3–75 kW floating/swimming & suction IWHC robotsNeutral or slightly floating (-35 to 0 kg/km)In-water ship hull biofouling grooming, brush & cavitation ROVs
TF-MCR Magnetic Crawler CableDry-dock & amphibious magnetic wheeled crawlersUltra-low air weight (112–740 kg/km) to prevent de-mag25–40 m vertical hull UHP hydroblasting, grit blasting & NDT
TF-HULLUMB Hydraulic Umbilical172–350 bar hydraulic brush-cart hull cleanersMulti-hose thermoplastic bundle (-561 kg/km buoyant)Twin/triple hydraulic brush carts & diver brush tools
DLRB / 2GAX–8GAX Mini TetherMicro observation ROVs (250–300 V, 26 AWG)Ultra-slim Ø 4.0–8.2 mm neutral buoyancyLight visual hull & sea-chest camera inspection only

Does your hull-cleaning vehicle swim/hover with thrusters or climb dry vertical hull plates on permanent magnets? Use buoyant TF-HULL in water so slack floats clear of propellers; use ultralight TF-MCR in dry dock where foam flotation adds dead weight in air.

TF-HULL Hull-Cleaning Robot Tether Engineering RFQ Checklist

  • Vehicle electrical load (kW, operating voltage in V DC or V AC, max current, and tether run length in meters, e.g., 100 m, 250 m or 400 m).
  • Conductor preference: standard Class 5/6 tinned or bare copper, or custom lightweight aluminum-alloy power cores (24XM308 / 12GAX64 type).
  • Optical / data / fluid core count: SM G.657.A2 or MM OM3 fiber count, subsea Cat 6 pairs, and any polyamide (PA) sampling micro-tube ID/OD.
  • Target water density (river/brackish SG 1.000 vs seawater SG 1.026) and outer jacket choice (Shore 94A Neon Yellow / Fluorescent Orange / Black PUR, hydrocarbon-resistant PUR, or slick UV-LDPE).
  • Required continuous reel length(s) (supplied as bulk cable with heat-shrink water-blocking end caps; MOQ 50 m, lead time 7 to 45 working days).

Related selection resources

TF-HULL Ship Hull Biofouling Cleaning Robot Tether FAQ

Why do ship hull biofouling cleaning robots require slightly positive or neutral buoyancy on TF-HULL tether cables?

0 to -30 g/m tuned buoyancy keeps unused tether slack floating near the water surface away from rudder pintles, bilge keels, thruster tunnels and seabed debris while minimizing hydrodynamic drag on the cleaning vehicle.

How does the TF-HULL outer jacket resist barnacle shell cuts and port fuel slicks?

Shore 94A high-tear polyether polyurethane (or high-density slick UV-LDPE on 12GAX49 / 3GAX47 builds) resists slicing against sharp calcareous barnacles and oyster shells, while oil-resistant matte PUR grades (12XM388) withstand crude oil, diesel, naphtha and antifouling paint residue.

Can TF-HULL be manufactured with lightweight aluminum-alloy power conductors or high-visibility turbid-water jackets?

Yes — alongside standard Class 5/6 tinned and bare copper conductors, we manufacture custom aluminum-alloy subsea power cores (matching 12GAX64 and 24XM308 weight budgets) and extrude Neon Yellow or Fluorescent Orange PUR sheaths for murky harbor visibility without fragile electroluminescent wires.

Does TF-HULL ship with pre-molded subsea connectors or as bulk cable on reels?

100% of TF-HULL orders are delivered as continuous cut-to-length bulk cable on wooden drums with heat-shrink water-blocking end caps so your team can terminate and pot subsea wet-mateable plugs and strain-relief grips matching your exact vehicle bulkhead.

What is the minimum order quantity and production lead time for TF-HULL hull-cleaning robot tethers?

50 m minimum order quantity per specification, custom-extruded and tested with delivery in 7 to 45 working days.

Specifications

TF-HULL (3–75 kW & 8GAX / XM Series) Tether Schedule

TF-HULL Buoyancy Trim, Barnacle-Cut Jacket & 50 m MOQ

  • Harbor seawater buoyancy tuning: Formulated for exact neutral or slightly floating trim (-35 to +20 g/m) across river-estuary anchorages (SG 1.000) and ocean ports (SG 1.025–1.028) to keep slack clear of vessel propellers and thrusters
  • Barnacle-cut & bunker-oil jacket: High-tear Shore 94A hydrolysis-resistant polyether PUR (or slick low-friction UV-LDPE) resists razor-sharp barnacle/oyster shells, port bunker fuel, diesel, crude residue and copper antifouling leachates
  • 3–75 kW copper or Al-alloy cores: Standard IEC 60228 Class 5/6 tinned or bare copper power cores with syntactic foam flotation, plus optional lightweight aluminum-alloy subsea power conductors (24XM308 / 12GAX64 builds)
  • FIMT fiber, Cat 6 & PA micro-tube: Integrates laser-welded stainless-steel tube G.657.A2 fibers, 100-ohm subsea Cat 6 Ethernet and optional polyamide (PA) water-quality / biocapture sampling micro-hoses
  • Continuous bulk reel, MOQ 50 m: Delivered as continuous cut-to-length bulk cable on wooden drums with heat-shrink water-blocking end caps (connectors field-potted by client); MOQ 50 m in 7 to 45 working days
TF-HULL Ship Hull Biofouling Cleaning & Grooming Robot Buoyant Hybrid Tether Cable (8GAX50, 12GAX49, 24XM308 & 13XM469 Series) technical data
ParameterValue
Rated voltage400 to 1000 V DC (Power-over-Tether) and 0.6/1 kV AC power cores; 250 to 300 V signal and data pairs
Conductor optionsIEC 60228 Class 5 or Class 6 tinned or bare copper (1.5 to 25 mm2), plus custom lightweight aluminum-alloy subsea power cores
Buoyancy and water-blockingCustom neutral or slightly floating trim (-35 to +20 kg/km) tuned to fresh/brackish (SG 1.000) or seawater (SG 1.025 to 1.028); longitudinal water-blocked
Strength member and jacketTorque-balanced aramid or LCP yarn braid (5 to 70 kN MBL); Shore 94A cut-resistant PUR (Neon Yellow, Fluorescent Orange, Black) or slick UV-LDPE
Supply form and MOQContinuous bulk cable on wooden drums with heat-shrink water-blocking end caps (no pre-potted connectors); MOQ 50 m in 7 to 45 working days
Operating temperature and depth-30 °C to +80 °C dynamic marine operation; syntactic/cellular flotation rated from shallow port surface down to 300 m (up to 500 m on solid builds)
Hydrocarbon and chemical resistanceResistant to seawater, harbor bunker fuel, diesel, crude oil slicks, condensate, naphtha and copper/zinc antifouling paint leachates

TF-HULL (3–75 kW) Hull Biofouling Cleaning Robot Tether Schedule

TF-HULL Ship Hull Biofouling Cleaning & Grooming Robot Tether Schedule (3 kW to 75 kW Engineering Series)
Model & Power TierPower & Control CoresOptical / Ethernet & TubeNom. OD (mm)Seawater Weight SG 1.026 (kg/km)Min. Breaking Load (kN)Min. Dyn. Bend Radius (mm)Next step
TF-HULL-3K (Grooming)4 × 1.5 mm² (600/1,000 V)Subsea Cat 6 (4P×24 AWG)13.8-5 (Slightly Floating)8.5140Request this size
TF-HULL-7K (Light IWHC)4 × 2.5 mm² + 2 × 0.5 mm²4 SM G.657.A2 FIMT16.5-8 (Slightly Floating)15.0165Request this size
TF-HULL-15K (Brush/Jet)4 × 6.0 mm² + 2P × 0.34 mm²4 SM + 4 MM FIMT + PA Tube22.80 to -12 (Neutral/Float)25.0230Request this size
TF-HULL-30K (Cavitation)3 × 10 + 1G6 mm² (0.6/1 kV)8 SM/MM FIMT + PA Tube28.50 to -18 (Neutral/Float)38.0285Request this size
TF-HULL-50K (Work IWHC)3 × 16 + 1G10 mm² (0.6/1 kV)8 SM FIMT + 2P × 0.5 mm²33.60 to -25 (Buoyant PUR)50.0340Request this size
TF-HULL-75K (Heavy IWHC)3 × 25 + 1G16 mm² (Cu or Al-Alloy)8 SM FIMT + 4P × 0.5 mm²39.20 to -30 (Buoyant Oil-PUR)65.0395Request this size

TF-HULL (8GAX / 3GAX / XM Series) Cross-Reference Tether Schedule

TF-HULL Cross-Reference Marine Biofouling & ROV Hybrid Tether Schedule (8GAX50, 12GAX49, 24XM308, 3GAX47, 12GAX64 & XM469–XM388)
Model & Cross-ReferenceConductor & Core MakeupData / Fiber / Tube ElementNom. OD (mm)Jacket & Buoyancy DesignBreaking Load (kN)Bulk Reel MOQNext step
TF-HULL 8GAX50Tinned Cu power + signal cores (HDPE)Twisted telemetry pairs11.3Foam PUR + UV-PUR (Neutral)6.050 mRequest this size
TF-HULL 12GAX49Bare Cu heavy-duty ROV power/controlControl & video pairs17.0Foamed polyolefin + slick UV-LDPE18.050 mRequest this size
TF-HULL 13XM469Tinned Cu + XLPE / ETFE power coresSM/MM FIMT + Polyamide (PA) hose17.0LCP/Aramid + matte UV-PUR (Buoyant)20.050 mRequest this size
TF-HULL 24XM308Balanced Tinned Cu + Al-Alloy power (PP)Electro-optical SM/MM fiber unit22.7Swelling waterblock + Aramid + PUR28.050 mRequest this size
TF-HULL 3GAX47XL-HDPE power/signal + TCWB overall screenSingle-mode long-range fiber unit23.0Aramid + UV-LDPE (Neutral, up to 7 km)68.6 (7,000 kg)50 mRequest this size
TF-HULL 12GAX64Lightweight Aluminum-Alloy power (PE)Integrated flexible subsea Cat 631.1Aramid braid + UV-PUR (Neutral)35.050 mRequest this size
TF-HULL 12XM463High-power tinned Cu + XLPE coresMM/SM FIMT + glass/aramid barrier33.6Halogen-free flame-retardant PUR (Buoyant)45.050 mRequest this size
TF-HULL 12XM388High-power bare Cu + XL-HDPE cores4-pair SM fiber unit + waterblock39.25Crude/naphtha/diesel-resistant matte PUR60.050 mRequest this size

Note on harbor salinity and conductor selection: freshwater river ports (such as anchorage basins at SG 1.000) provide 2.6% less buoyant lift than open ocean ports (SG 1.026). State your target port salinity and whether you prefer standard tinned/bare copper or lightweight aluminum-alloy conductors (as in 24XM308 and 12GAX64) so our engineers lock foam density prior to extrusion.

ASCII part references for BOM and ERP entry: TF-HULL-3K, TF-HULL-7K, TF-HULL-15K, TF-HULL-30K, TF-HULL-50K, TF-HULL-75K, TF-HULL-8GAX50, TF-HULL-12GAX49, TF-HULL-13XM469, TF-HULL-24XM308, TF-HULL-3GAX47, TF-HULL-12GAX64, TF-HULL-12XM463, TF-HULL-12XM388.

Standards

TF-HULL Subsea Umbilical & Fiber Reference Standards

TF-HULL Ship Hull Biofouling Cleaning & Grooming Robot Buoyant Hybrid Tether Cable (8GAX50, 12GAX49, 24XM308 & 13XM469 Series) standards and test references
Standard or specificationApplication
IEC 60228 Class 5 / Class 6 & Custom Aluminum-Alloy Subsea ConductorsFlexible multi-strand bare/tinned electrolytic copper conductors and weight-saving marine aluminum-alloy power conductors.
ISO 13628-5 / IEC 60794-3 & Longitudinal Water-Blocking DesignSubsea umbilical layout, crush-resistant stainless-steel optical tube (FIMT) attenuation control and dry swelling water-blocking verification.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and hydrostatic/electrical factory verification

ISO 13628-5 — Design and verification principles for subsea electro-optical umbilicals

IEC 60794-3 — Optical fibre cables for submarine and harsh outdoor environments

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.