Marine & Offshore Cables TEBAOFLEX

RM-Series & EOM Torque-Balanced Steel-Armoured Work-Class ROV Main-Lift Umbilical Cable (1–4.5 kV)

RM-Series and EOM torque-balanced steel-armoured ROV main-lift umbilical cables (RM0049, RM0066, RM0037, RM0067, RM0060 and A304-series, 17.3 to 45.5 mm OD) integrate 1.0 to 4.5 kV medium-voltage copper power triads, shielded control pairs and hermetically sealed stainless-steel FIMT optical tubes beneath 2- or 3-layer contra-helical high-tensile galvanized steel wire armour rated 185 to 880 kN minimum breaking load.

Product information
SKU
TF-EOM-ROV-MAINLIFT
Brand
TEBAOFLEX
Product overview

RM-Series and EOM torque-balanced steel-armoured ROV main-lift umbilical cables (spanning RM0049 at 17.3 mm / 185 kN through RM0060 at 41.2 mm / 880 kN and A304562 at 45.5 mm / 845 kN) serve as the primary electro-opto-mechanical lifting line between vessel Launch and Recovery Systems (LARS) and deepwater Tether Management Systems (TMS) or free-swimming work-class vehicles down to 4,000–6,000 m.

In vertical deployment through harsh splash zones and active heave compensation (AHC) sheave cycling, an uncompensated single-lay wire rope spins under load, hockling conductors and snapping optical fibres when tension relaxes on the seabed. Each TEBAOFLEX EOM main-lift cable balances helical torque across opposing left- and right-hand layers of high-tensile galvanized improved plow steel (GIPS) or Zn-5Al alloy wire, pressure-injected with marine bitumen/grease blocking compound over a water-blocked polymeric inner jacket housing 3 to 20 medium-voltage copper power cores, shielded instrumentation pairs/quads and gel-filled stainless-steel Fiber-In-Metal-Tube (FIMT) assemblies.

Choose RM-Series and EOM bare steel-armoured main-lift umbilicals for high-tension traction or Lebus storage winches supporting heavy work-class ROV garages, subsea ploughs and salvage spreads. Where a companion flame-retardant topside jumper is also needed see our RS726 / FMBP Umbilical & Deck Cable page, or for neutral-buoyancy cage-to-vehicle excursion tethers select our GAX / Synthetic ROV Tether series.

Explore the marine, offshore and shipboard cable range for related configurations.

Construction

EOM RM-Series Torque-Balanced Steel-Armoured Main-Lift Construction

Every EOM main-lift umbilical combines void-free water-blocked electrical-optical core stranding with computer-balanced contra-helical high-tensile steel armour layers engineered to prevent birdcaging and torsional spin during deepwater AHC cycling.

Clean 2D engineering cross-section of EOM work-class ROV main-lift umbilical cable showing concentric medium-voltage copper power conductors, shielded signal pairs, gel-filled stainless-steel FIMT optical fibre tube, water-blocked inner sheath and two opposing contra-helical galvanized steel wire armour layers
EOM main-lift cross-section: MV tinned copper power cores, shielded telemetry pairs, 316L stainless-steel FIMT tube, HDPE/polyester inner sheath and opposing SWA layers.
RM-Series & EOM Torque-Balanced Steel-Armoured Work-Class ROV Main-Lift Umbilical Cable (1–4.5 kV) construction
ComponentMaterial and construction
1. Medium-Voltage Power ConductorsFine-stranded tinned annealed copper (IEC 60228 Class 5, 3.0 to 16.0 mm² / 12 to 6 AWG) insulated with thin-wall cross-linked polyolefin, EPR or polypropylene for 1.0 kV, 3.0 kV or 4.5 kV 3-phase vehicle and TMS motor supply.
2. Control, Telemetry & Auxiliary CoresInsulated tinned copper control singles, shielded twisted pairs or star quads (0.50 to 2.5 mm², 600/1000 V) with aluminium/PET or tinned copper braid screening for sonar, valve packs and TMS sensors.
3. Hermetic Stainless-Steel Optical Element (FIMT)One or two laser-welded 316L stainless-steel tubes (1.5 to 3.2 mm tube OD, thixotropic hydrogen-scavenging gel) over-sheathed in polyolefin, protecting 4 to 12 single-mode (G.652.D / G.657.A1) or multimode fibres to 60 MPa.
4. Water-Blocked Interstices & Inner SheathElastomeric water-blocking compound and synthetic fillers eliminating internal compression voids, enclosed by a tough seamless HDPE, thermoplastic polyester or polyurethane inner bedding jacket.
5. Inner & Outer Contra-Helical Steel Wire ArmourTwo (or three) opposing helical layers of preformed galvanized improved plow steel (GIPS, 1,770 to 2,160 MPa tensile grade) or Zn-5Al coated steel wires engineered for near-zero net torque across 10% to 50% MBL.
6. Pressure-Injected Corrosion & Wear MatrixMarine-grade anti-corrosive wire-rope lubricant pressure-injected across every armour interstice to cut inter-wire fretting over AHC sheaves (optional extruded HDPE or PUR outer jacket available for corrosive/abrasive winches).
TEBAOFLEX factory sample photograph of double contra-helical galvanized steel wire armoured ROV and subsea main-lift umbilical cable cut cross-section showing outer ring of six heavy copper power conductors, inner control cores, stainless-steel optical FIMT tube and dual steel wire armour layers
TEBAOFLEX workshop production sample: dual contra-helical steel wire armour enclosing six outer heavy copper power cores, inner control cores and stainless-steel FIMT tube.

EOM & RM-Series Main-Lift Umbilical Code & Layer Breakdown

  • EOM: Electro-Opto-Mechanical umbilical combining medium-voltage electrical power, optical fibre telemetry and load-bearing steel armour in one dynamic lift line
  • RM0037 / RM0049 / RM0060 / RM0066 / RM0067: standardized ROV main-lift umbilical configurations spanning 17.3 mm (185 kN) light work-class to 41.2 mm (880 kN) ultra-heavy work-class builds
  • FIMT (1x6SM / 2x4SM): Fiber-In-Metal-Tube: laser-welded 316L stainless-steel micro-tube filled with hydrogen-scavenging gel housing 4 to 12 single-mode optical fibres
  • GIPS / Zn-5Al Contra-Helical SWA: two or three opposing helical layers of Galvanized Improved Plow Steel or zinc-5% aluminium coated high-tensile wire balanced for near-zero torque
Applications

EOM Work-Class ROV, AHC LARS Winch & Trenching Main-Lift Applications

Specify RM-Series and EOM torque-balanced steel-armoured umbilicals on offshore construction vessels, drillships and subsea intervention spreads operating heavy LARS winches.

Offshore vessel aft deck A-frame Launch and Recovery System lowering a heavy work-class ROV and Tether Management System cage into deep ocean swells on a tensioned torque-balanced steel-wire-armoured main-lift umbilical cable
Work-class ROV and TMS cage deployed through the splash zone on a torque-balanced steel-armoured EOM main-lift umbilical.
  • Deepwater work-class ROV + top-hat or side-entry Tether Management System (TMS) main-lift winches rated 1,500 to 4,000 m.
  • Active Heave Compensation (AHC) traction and storage winch systems demanding torque-neutral steel armour over flag and overboarding sheaves.
  • High-power subsea pipeline trenchers, cable-burial ploughs and salvage tool skids drawing 100 to 400 kVA over minimal umbilical diameter.
  • Scheduled drum re-roping and emergency short-lead replacement of RM0037, RM0049, RM0060, RM0066, RM0067 and A304-class main-lift cables.

EOM Steel-Armoured Main-Lift vs Synthetic Lift vs Excursion Tether Boundary

EOM Steel-Armoured Main-Lift Umbilical vs Synthetic Aramid Lift Umbilical vs Excursion Tether
Umbilical ArchitectureStrength MemberSeawater Weight & Depth AdvantagePrimary ROV Role
RM-Series / EOM Steel-Armoured (this page)2- or 3-layer contra-helical GIPS / Zn-5Al steel wire815 to 5,193 kg/km | high crush resistance on multi-layer drums100 to 4,000 m work-class ROV + heavy TMS cage main lift
Synthetic-Armoured Lift Umbilical (ID 6024)Contra-helical LCP / aramid yarn under PUR jacketNear-neutral to light negative | eliminates steel self-weightUltra-deepwater (> 3,500 m) or weight-limited portable LARS winches
Neutrally Buoyant ROV Tether (ID 6016 / 6018)Braided aramid fibre + foamed buoyancy TPR/PUR jacketZero / slightly positive buoyancy in seawater150 to 1,000 m horizontal excursion from TMS garage to free-flying ROV
RS726-DC FMBP Deck Jumper (UMB01)Dual galvanized steel tape + flame-retardant PVCTopside tray routing only (not for submerged winching)Static deck interconnect between HPU van and winch slip-ring box

In 500 to 3,500 m work-class ROV operations with heavy TMS cages, bare contra-helical steel wire armour remains the offshore workhorse because its radial stiffness resists multi-layer drum crushing and conducts heat rapidly into seawater.

EOM ROV Main-Lift Umbilical RFQ Engineering & Winch Specification Checklist

  • Reference model (such as RM0049, RM0066, RM0037, RM0067, RM0060 or A304562) or custom core count + target outer diameter (mm).
  • Operating water depth (m), ROV + TMS wet weight (kg), AHC dynamic load factor and required Minimum Breaking Load (kN).
  • Power circuit voltage (for example 3,000 V or 4,160 V 3-phase), apparent power (kVA), acceptable voltage drop (%) and control pair/quad count.
  • Optical fibre count (SM 9/125 µm or MM 50/125 µm) and whether redundant dual stainless-steel FIMT tubes are required.
  • Existing LARS drum core diameter, Lebus groove pitch, traction/overboarding sheave root diameter and slip-ring/socket interface.
  • Continuous length per reel (MOQ 50 m; lead time 7 to 45 working days) and export steel drum dimensional/weight limits.

Related selection resources

EOM Steel-Armoured ROV Main-Lift Umbilical Frequently Asked Questions

What minimum breaking load do RM-Series and EOM steel-armoured ROV main-lift umbilicals provide?

185 kN to 880 kN across standard builds: EOM RM0049 (17.3 mm OD) provides 185 kN, EOM RM0037 (35.1 mm) provides 680 kN, EOM RM0066 (34.1 mm) provides 695 kN, and heavy work-class EOM RM0067 (39.7 mm) and EOM RM0060 (41.2 mm) each deliver 880 kN minimum breaking load.

Why do EOM ROV main-lift umbilicals use contra-helical steel wire armour instead of single-layer armour?

2 or 3 opposing helical layers cancel rotational torque under tension. A single armour layer acts like a torsion spring that twists the ROV/TMS during descent and forms destructive kinks (hockles) if tension drops on the seafloor; contra-helical EOM armour keeps rotation within ±2 degrees per meter.

How are optical fibres protected against 4,000 m hydrostatic pressure inside an EOM ROV umbilical?

Laser-welded 316L stainless-steel Fiber-In-Metal-Tube (FIMT) construction protects the fibres. Single-mode or multimode fibres are cushioned in hydrogen-absorbing thixotropic gel with 0.15% to 0.25% excess fibre length inside a seamless steel micro-tube before polymeric over-sheathing, isolating the glass from 40 to 60 MPa water pressure and axial stretch.

Can TEBAOFLEX custom-match an EOM main-lift umbilical outer diameter to an existing Lebus winch shell?

Yes. TEBAOFLEX engineers power conductor insulation wall, filler geometry and contra-helical armour wire gauges to hold nominal outer diameter within ±0.5 to ±0.8 mm of your existing Lebus groove pitch, starting from a 50 m minimum order quantity.

What are the minimum order quantity and delivery lead time for EOM steel-armoured ROV main-lift cables?

50 m minimum order quantity (MOQ), with a production lead time of 7 to 45 working days depending on continuous drum length (up to 5,000 m+) and FIMT/armour specification.

Specifications

EOM RM-Series & A304-Series Dimensional, Weight & Breaking-Load Schedule

EOM ROV Main-Lift Key Mechanical, Electrical & Optical Summary

  • Breaking strength envelope: 185 kN (17.3 mm inspection/light work-class) up to 680–880 kN (35.1–45.5 mm heavy work-class and trenching main lift)
  • Torque-balanced SWA: Contra-helical 2- or 3-layer galvanized improved plow steel (GIPS) or Zn-5Al wire armour holding rotation within ±2 deg/m
  • Deepwater FIMT optics: 1 or 2 laser-welded 316L stainless-steel tubes (4 to 12 SM/MM fibres) qualified for 3,000 to 6,000 m hydrostatic pressure
  • Low-loss HV power delivery: 1.0 to 4.5 kV thin-wall XLPE/EPR/PP insulated tinned copper power cores minimizing voltage drop across 3,000 to 5,000 m winches
  • Custom winch replacement: Engineered to match existing traction winch sheave ratios and drum core diameters; MOQ 50 m, 7 to 45 working days
RM-Series & EOM Torque-Balanced Steel-Armoured Work-Class ROV Main-Lift Umbilical Cable (1–4.5 kV) technical data
ParameterValue
Rated voltage1.0 kV to 4.5 kV AC 3-phase main power cores with 600 to 1000 V auxiliary and instrumentation circuits
Reference model rangeRM0049 (17.3 mm), RM0066 (34.1 mm), RM0037 (35.1 mm), A304472 (36.3 mm), RM0067 (39.7 mm), RM0060 (41.2 mm), A304562 (45.5 mm)
Breaking strength envelope185 kN to 880 kN minimum breaking load (MBL) with torque-balanced 2-layer or 3-layer GIPS / Zn-5Al steel wire armour
Optical telemetry package4 to 12 single-mode or hybrid SM/MM optical fibres sealed in gel-filled 316L stainless-steel FIMT tubes (4,000 to 6,000 m depth)
Bend radius and commercial terms355 to 790 mm minimum bend radius depending on OD with MOQ 50 m and 7 to 45 working days manufacturing lead time
Operating temperature range-20 °C to +60 °C dynamic seawater operation; -30 °C to +75 °C topside winch drum storage (verify top-layer solar/I²R derating)
Torsional stabilityOpposing helical armour lay angles engineered to keep cable rotation within ±2 degrees per meter across working tension

EOM RM-Series & A304-Series Work-Class ROV Main-Lift Umbilical Schedule

RM-Series (RM0005–RM0067, Complete 13-Model Schedule) & A304-Series Steel-Armoured Work-Class ROV Main-Lift EOM Umbilical — Dimensional, Mass & MBL Schedule
Model & Core LayoutNominal Outer Diameter (mm)Power + Control + Fibre CountWeight in Air (kg/km)Weight in Seawater (kg/km)Min. Bend Radius (mm)Min. Breaking Load MBL (kN)Next step
EOM RM0029 (5x4+1x0.22STQ+6SM)17.35x4 mm² + 1x0.22 mm² STQ + 6 SM FIMT1050810280140Request this size
EOM RM0049 (3x5+2x0.5+1x6SM)17.33x5 mm² + 2x0.5 mm² + 6 SM FIMT1060815355185Request this size
EOM RM0026 (3x4+2x2.5+5SM/1MM)19.13x4 mm² + 2x2.5 mm² + 5 SM / 1 MM FIMT1220920260200Request this size
EOM RM0035 (6x6.5+4x1.2+6SM)28.56x6.5 mm² + 4x1.2 mm² + 6 SM FIMT29102260400480Request this size
EOM RM0045 (9x10AWG+13x18AWG+7SM)33.29x10 AWG + 13x18 AWG + 7 SM FIMT41003270750659Request this size
EOM RM0053 (3x8.4+2x1.34STP+6SM)34.13x8.4 mm² + 2x1.34 mm² STP + 6 SM FIMT41003150750695Request this size
EOM RM0066 (3x8.4+4x1.34+1x6SM)34.13x8.4 mm² + 4x1.34 mm² + 6 SM FIMT41003150750695Request this size
EOM RM0015 (11x4+8x1.5+1STQ+8FO)35.111x4 + 8x1.5 mm² + 0.6 STQ + 4SM/4MM (2 FIMT)42003200480680Request this size
EOM RM0037 (11x4+8x1.5+4x0.6+2x4SM)35.111x4 + 8x1.5 + 4x0.6 mm² + 8 SM (2 FIMT)42003200480680Request this size
EOM A304472 (13P+4S+6SM)36.313 Power + 4 Signal + 6 SM FIMT37502838725449Request this size
EOM A302467 (6P+3S+6SM)38.16 Power + 3 Signal + 6 SM FIMT1890746760498Request this size
EOM RM0067 (9x8.4+5x2.5+1x6SM)39.79x8.4 mm² + 5x2.5 mm² + 6 SM FIMT56004350790880Request this size
EOM RM0042 (41x2+1x1.5STP+12SM)39.841x2 mm² + 1x1.5 mm² STP + 12 SM FIMT49603700600720Request this size
EOM RM0060 (12x5+5x3+2x1+4x0.6+1x6SM)41.212x5 + 5x3 + 2x1 + 4x0.6 mm² + 6 SM FIMT57004350700880Request this size
EOM A304562 (20P+4S+1Coax+7SM)45.520 Power + 4 Signal + 1 Coax + 7 SM FIMT66805193910845Request this size
EOM RM0005 (18x10+1x1.34STQ+12SM)58.018x10.0 mm² + 1x1.34 mm² STQ + 12 SM (3 FIMT)1265099508001975Request this size

EOM Steel Armour Safe Working Load & LARS Sheave Integration Parameters

EOM Main-Lift Steel Wire Armour Design Rules — Safe Working Load, Sheave D/d Ratio & Drum Thermal Derating
Engineering Parameter2-Layer Contra-Helical SWA3-Layer Contra-Helical SWALARS Winch & Integration Rule
Typical Safe Working Load (SWL)20% to 25% of MBL (dynamic factor 4:1 to 5:1)22% to 28% of MBL with reduced wire bending stressSum submerged cable weight + ROV/TMS wet weight + AHC snatch load
Recommended Dynamic Sheave Diameter35 x to 40 x Cable OD (min. 20 x OD bend radius)30 x to 36 x Cable OD for compact LARS A-framesMatch sheave groove radius to 0.525–0.55 x nominal cable OD
Optical Fibre Excess Fiber Length (EFL)0.15% to 0.25% positive EFL inside gelled SS tube0.15% to 0.25% positive EFL inside gelled SS tubePrevents tensile strain on G.652.D fibres up to copper yield load
Winch Drum Dead-Wraps CoolingDerate current on > 3 uncooled drum layersDerate current on > 3 uncooled drum layersMaintain forced air/water drum cooling during topside deck testing

Safe Working Load (SWL) in dynamic offshore sea states must account for total suspended seawater mass (for example, 3,000 m of EOM RM0060 adds 3 x 4,350 kg = 13,050 kg / ~128 kN static self-weight before TMS/ROV payload and vessel heave acceleration).

Do not energize full medium-voltage HPU current for extended periods while multiple layers remain coiled in air on an uncooled storage drum; submarine heat dissipation in seawater is 8 to 12 times higher than stagnant multi-layer drum wraps.

Minimum order quantity is 50 m (supporting both short test/termination qualification lengths and continuous 1,500 to 5,000 m production winch lengths), with a lead time of 7 to 45 working days.

ASCII part references: EOM RM0049; EOM RM0066; EOM RM0037; EOM RM0067; EOM RM0060; A304472; A302467; A304835; A304562; ROV main lift EOM umbilical.

Full 13-model RM main-lift & heavy trencher cross-reference coverage: RM0005 (58.0 mm, 1975 kN heavy trencher / deep-ocean research), RM0015 (35.1 mm, 680 kN), RM0026 (19.1 mm, 200 kN), RM0029 (17.3 mm, 140 kN), RM0035 (28.5 mm, 480 kN), RM0037 (35.1 mm, 680 kN), RM0042 (39.8 mm, 720 kN), RM0045 (33.2 mm, 659 kN), RM0049 (17.3 mm, 185 kN), RM0053 (34.1 mm, 695 kN), RM0060 (41.2 mm, 880 kN), RM0066 (34.1 mm, 695 kN) and RM0067 (39.7 mm, 880 kN).

Standards

EOM Subsea Main-Lift Umbilical Standards & Routine Factory Test References

RM-Series & EOM Torque-Balanced Steel-Armoured Work-Class ROV Main-Lift Umbilical Cable (1–4.5 kV) standards and test references
Standard or specificationApplication
ISO 13628-5 (Subsea Umbilicals)Mechanical load-sharing, torque-balance verification, hydrostatic pressure integrity and factory electrical/optical acceptance framework.
DNV-ST-E402 / Offshore LARS PracticeDesign alignment for dynamic umbilical safety factors, minimum overboarding sheave ratios and mechanical socket termination interfaces (project witness testing available on request).
IEC 60228 & High-Voltage DC/AC Routine TestsClass 5 tinned copper conductor resistance and high-voltage dielectric withstand verification across every insulated power and control circuit.
ITU-T G.652.D / G.657.A1 Optical Telemetry1310 nm and 1550 nm OTDR attenuation profiling before and after contra-helical steel wire armouring (typical attenuation <= 0.40 dB/km at 1310 nm, <= 0.25 dB/km at 1550 nm).

Certifications and document support

TEBAOFLEX quality system, HV dielectric withstand and OTDR routine test reports

ISO 13628-5 — Design and operation of subsea production and ROV umbilicals

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.