UL 5359 Mica-Glass Wire, 600V 200/450°C
UL 5359 is a UL-certified mica-insulated wire rated 600 V AC, with 200°C and 450°C construction options. This page includes a detailed 450°C single-conductor selection table for high-temperature equipment leads protected from mechanical damage.
- tension: 600 V AC
- Température: 200°C or 450°C by construction
- Isolation / revêtement : mica tape and treated fiberglass braid
- Sélection de la taille : 30 AWG–4/0 AWG style range; table: 26 AWG–4/0 AWG
- Certification : AWM certifié UL; UL 758
UL 5359 wire selection
UL 5359 is a UL-certified mica-insulated wire rated 600 V AC, with 200°C and 450°C construction options. This page includes a detailed 450°C single-conductor selection table for high-temperature equipment leads protected from mechanical damage.
The 18 dimensioned configurations cover 26 AWG through 4/0 AWG. Each row combines UL 5359 with the conductor size and lists stranding, mica thickness, fiberglass-braid thickness and finished diameter. The wall schedule increases in steps as the conductor becomes larger, so the table supports both electrical size selection and the practical fit of sleeves, clamps and equipment entries.
For heater, oven or process-equipment wiring, choose the required temperature grade before comparing diameters. The 200°C and 450°C constructions are separate selections under the same style number. Installation should avoid repeated flexing and protect the mica-and-braid system from mechanical abuse. The operating current must be assessed for the selected conductor, ambient conditions, grouping and complete equipment application.
Consultez l’onglet Caractéristiques pour les tableaux de modèles et de calibres. Parcourez la gamme de câbles haute température pour des constructions apparentées. Comparer MGT mica-glass wire for the existing 5107/5128 lead wire construction.
Construction
UL 1813 utilise le système conducteur et d'isolation suivant. Le schéma illustre la séquence des couches ; sélectionnez la construction du conducteur et le revêtement indiqués dans les spécifications de taille requises.

| Composant | détail de construction |
|---|---|
| Conducteur | Stranded nickel-coated copper or nickel, selected for the required construction |
| Isolation | Ruban mica |
| Revêtement extérieur | Treated fiberglass braid |
Applications
UL 5359 is used for protected internal leads in high-temperature equipment, including heaters and ovens. Keep the mica-insulated lead supported and avoid locations with repeated bending or rubbing.

UL 5359 replacement selection
Pour une demande de remplacement, fournissez le marquage du fil existant et le schéma de raccordement de l’équipement afin de comparer le conducteur, l’isolation et la disposition des bornes.
Caractéristiques techniques
| Paramètre | Spécification |
|---|---|
| Style UL | UL 5359 |
| Tension assignée | 600 V AC |
| Indice de température | 200°C or 450°C by construction |
| Isolation / revêtement | mica tape and treated fiberglass braid |
| Plage de calibres du conducteur | 30 AWG–4/0 AWG style range; table: 26 AWG–4/0 AWG |
| Temperature choices | 200°C or 450°C, according to construction |
| Tension assignée | 600 V AC |
| Installation | Protected internal wiring without repeated flexing |
450°C single-conductor dimensional reference. Nominal construction dimensions are for selection; the quotation drawing defines the supplied configuration.
| Modèle et calibre du conducteur | Brins du conducteur (n°/mm) | Mica wall (mm) | Braid wall (mm) | Diamètre extérieur nominal / tolérance (mm) |
|---|---|---|---|---|
| UL 5359 26 AWG | 7/0.16 | 0.41 | 0.18 | 1.8±0.1 |
| UL 5359 24 AWG | 7/0.2 | 0.41 | 0.18 | 1.9±0.1 |
| UL 5359 22 AWG | 7/0.254 | 0.41 | 0.18 | 2.1±0.2 |
| UL 5359 20 AWG | 10/0.254 | 0.41 | 0.18 | 2.2±0.2 |
| UL 5359 18 AWG | 16/0.254 | 0.41 | 0.18 | 2.5±0.2 |
| UL 5359 16 AWG | 26/0.254 | 0.41 | 0.18 | 2.8±0.2 |
| UL 5359 14 AWG | 41/0.254 | 0.41 | 0.18 | 3.2±0.3 |
| UL 5359 12 AWG | 65/0.254 | 0.41 | 0.18 | 3.6±0.3 |
| UL 5359 10 AWG | 103/0.254 | 0.51 | 0.38 | 5.1±0.5 |
| UL 5359 8 AWG | 163/0.254 | 0.51 | 0.38 | 6.0±0.5 |
| UL 5359 6 AWG | 260/0.254 | 0.51 | 0.38 | 7.1±0.5 |
| UL 5359 4 AWG | 413/0.254 | 0.51 | 0.38 | 8.2±0.5 |
| UL 5359 2 AWG | 168/0.5 | 0.64 | 0.51 | 10.5±0.8 |
| UL 5359 1 AWG | 212/0.5 | 0.64 | 0.51 | 11.5±0.8 |
| UL 5359 1/0 AWG | 268/0.5 | 0.64 | 0.51 | 12.7±0.8 |
| UL 5359 2/0 AWG | 342/0.5 | 0.64 | 0.51 | 14.0±0.8 |
| UL 5359 3/0 AWG | 430/0.5 | 0.64 | 0.51 | 15.4±0.8 |
| UL 5359 4/0 AWG | 538/0.5 | 0.64 | 0.51 | 17.0±0.8 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average mica wall (mils) | Minimum average treated braid (mils) |
|---|---|---|
| UL 5359 30–12 AWG | 16 | 7 |
| UL 5359 11–4 AWG | 20 | 15 |
| UL 5359 3–4/0 AWG | 25 | 20 |
Choix de la construction spécifiée
Specify UL 5359, AWG, 600 V AC and the required 200°C or 450°C construction. The dimension table below applies to the 450°C mica/fiberglass version.
Normes
TEBAOFLEX UL 5359 wire is UL-certified appliance wiring material.
| Article | Exigence ou référence |
|---|---|
| Certification | AWM certifié UL |
| Désignation du style | UL 5359 |
| Norme de construction | UL 758 — Matériaux de câblage pour appareils |
| Classement au feu du style | Flamme horizontale |
Indiquez le style UL, le calibre du conducteur et les classes de tension et de température dans le cahier des charges. Joignez à la demande l’identification du produit et les documents de certification requis.
Demandez une recommandation et un devis pour un câble.
Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.
- Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
- Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.