FEP-6Y & FEP-C-6Y Multi-Core & Screened FEP Control Cable (-100 to +205 °C)
FEP-6Y unscreened and FEP-C-6Y tinned-copper-braided multi-core high-temperature control cables (300/500 V and 600 V, 2,500 V AC test) combine IEC 60228 Class 5 tinned or silver-plated copper conductors (2×0.25 mm² to 25G1.5 mm² and 5G16 mm²) with full FEP-6Y insulation and outer sheathing for -100 °C to +205 °C chemical and furnace service.
FEP-6Y and screened FEP-C-6Y metric multi-core fluoropolymer control and power cables deliver chemical-proof, space-saving 300/500 V and 600 V interconnects from -100 °C to +205 °C, spanning 3.3 mm outer diameter on 2×0.25 mm² sensor cords up to 14.0 mm on 25G1.5 mm² control trunks and 5G16 mm² hot-zone motor feeders.
In pickling plants, electroplating lines, hot hydraulic presses, automotive paint-curing tunnels and chemical reactors, conventional SiHF / SiHFC silicone rubber cables swell in hot oils/solvents and violate PWIS/LABS silicone-free rules. Replacing elastomeric rubber with all-fluoropolymer FEP-6Y cores and outer sheathing cuts cable outer diameter by roughly one-third while resisting concentrated acids, alkalis, fuels, ozone, UV, microbes and up to 1 Mrad gamma radiation.
Specify unscreened FEP-6Y (OZ without earth or JZ/G with green-yellow earth) for heater contactors, limit switches and solenoid valves, or specify tinned/silver-plated copper braided FEP-C-6Y where frequency inverters or proportioning controllers demand 360-degree EMC screening. Choose tinned Class 5 copper up to +180 °C continuous or silver-plated Class 5 copper up to +205 °C continuous (+230 °C short-term peak), supplied on 300 m minimum order factory reels in 7 to 45 working days.
Explore the high-temperature wire and cable range for related configurations.
FEP-6Y & FEP-C-6Y Multi-Core Cable Construction
Each FEP-6Y and FEP-C-6Y cable uses low-friction fluoropolymer lay-up geometry, colour/number core coding per DIN VDE 0293 and dense metallic EMC braiding.

| Component | Material and construction |
|---|---|
| 1. Fine-Stranded Plated Copper Conductors (IEC 60228 Class 5) | Tinned copper strands (up to +180 °C continuous) or silver-plated copper strands (up to +205 °C continuous, +230 °C short-time). |
| 2. Extruded FEP-6Y Core Insulation & VDE Identification | DIN VDE 0207-6 Type 6Y FEP core wall; colour-coded per DIN VDE 0293 on 0.25 mm² or black cores with white numerals plus green-yellow earth (G) on >= 0.5 mm². |
| 3. PTFE/Fluoropolymer Binder & Optional Copper Braid (FEP-C-6Y) | Low-friction fluoropolymer lapping tape over laid-up cores, plus >= 85 % optical coverage tinned or silver-plated copper wire braid on screened FEP-C-6Y. |
| 4. Extruded FEP-6Y Chemical-Proof Outer Sheath | Non-flammable, abrasion- and solvent-immune FEP outer jacket (brick-red, black, white or blue) meeting IEC 60332-1-2 and < 0.01 % moisture uptake. |
FEP-6Y & FEP-C-6Y Designation Code Breakdown
- FEP: Fluorinated ethylene propylene insulation and outer jacket compound (-100 °C to +205 °C)
- C (in FEP-C-6Y): Concentric tinned or silver-plated copper wire EMC braid screen (>= 85 % optical coverage)
- 6Y: DIN VDE 0207-6 material code for fluoropolymer FEP compound
- G / x (OZ): G = includes green-yellow protective earth core; x (OZ) = numbered/coloured cores without earth
- CuSn / CuAg: Class 5 tinned copper (+180 °C) or silver-plated copper (+205 °C) conductor stranding
FEP-6Y & FEP-C-6Y Chemical, Paint-Oven & Kiln Applications
Engineered for aggressive thermal-chemical zones where elastomeric SiHF silicone or PVC/PUR control cables degrade prematurely.

- Steel strip acid-pickling tanks, hot-dip galvanizing lines, anodizing rectifiers and chemical etching/cleaning machinery.
- Automotive paint-drying ovens and semiconductor cleanrooms requiring 100 % LABS / PWIS silicone-free multi-core power and control wiring.
- Brickworks, ceramic roller kilns, glass annealing lehrs, plastics extrusion lines and commercial baking tunnel conveyors.
- Cryogenic cold-trap valves (-100 °C), pharmaceutical steam-sterilized skids and outdoor UV/ozone-exposed petrochemical analyzers.
FEP-6Y & FEP-C-6Y vs SiHF/SiHFC vs FFCT vs AWG FEP
| Multi-Core Cable Type | Temp. & OD (at 4G1.5) | Chemical, Oil & Silicone-Free Status | When to Specify |
|---|---|---|---|
| FEP-6Y & FEP-C-6Y (this page) | -100 to +205 °C | 6.3 / 7.1 mm OD | Immune to acids/solvents/oils; 100 % PWIS/silicone-free | European mm² chemical tanks, paint ovens, kilns & slim hot-zone conduits |
| SiHF-J & SiHFC Silicone (ID 1433 / 1440) | -60 to +180 °C | 8.0 / 9.2 mm OD | Soft elastomer; swells in hot acids/oils; contains silicone | Dry ventilated ovens, lighting & HVAC without solvent splash |
| FFCT / FFCT-SB (ID 5718) | -60 to +200 °C | JIS mm² | Japanese-standard 600 V fluoroplastic equipment cable | Japanese OEM semiconductor, furnace & machine-tool replacement BOMs |
| 600 V FEP/FEP & UL 20710 (FLU04) | -70 to +200 °C | North American AWG | AWG-gauged K-2 colour-coded FEP/FEP & ETFE control cable | North American 18–2 AWG tray/conduit & UL-style OEM specifications |
Choose FEP-C-6Y whenever VFD motor drives or analog sensors share cable trays in +200 °C or acid-fume zones.
FEP-6Y & FEP-C-6Y Multi-Core Cable RFQ Checklist
- Screening version: unscreened FEP-6Y or copper-braided EMC-screened FEP-C-6Y.
- Core count, earth convention (G with green-yellow earth vs x / OZ without earth) and cross-section (0.25 mm² to 16 mm²).
- Conductor plating: tinned copper (up to +180 °C continuous) or silver-plated copper (up to +205 °C continuous).
- Outer FEP sheath colour (brick-red, black, white or blue) and total meterage (MOQ 300 m factory reel, 7 to 45 working days).
Related selection resources
- Browse all High-Temperature Fluoropolymer, Silicone & Mica Cables
- Compare SiHF & SiHF-J 180 °C Multi-Core Silicone Cable
- Compare SiHFC & SiHF-C-Si Screened EMC Silicone Cable
- Compare Japanese-Standard FFCT & FFCT-SB 200 °C Fluoroplastic Cable
- Engineering guide: Braided copper shielding for industrial EMC
FEP-6Y & FEP-C-6Y Multi-Core FEP Cable FAQ
When should I specify FEP-6Y or FEP-C-6Y instead of SiHF or SiHFC silicone cable?
3 conditions require FEP-6Y over SiHF silicone: continuous exposure to acids, alkalis, hydraulic oils or solvents; automotive/cleanroom PWIS silicone-free mandates; or tight conduits needing a 30 % smaller outer diameter (6.3 mm vs 8.0 mm on 4G1.5 mm²) up to +205 °C.
What is the difference between tinned copper and silver-plated copper in FEP-6Y control cables?
25 °C of continuous conductor rating: tinned copper Class 5 conductors are rated up to +180 °C continuous, while silver-plated copper Class 5 conductors unlock the full +205 °C continuous (+230 °C peak) thermal ceiling of the FEP-6Y jacket.
How much electromagnetic shielding coverage does FEP-C-6Y provide?
85 % minimum optical braid coverage of tinned or silver-plated copper wires surrounds the laid-up FEP cores on FEP-C-6Y, suppressing VFD switching noise and inductive interference when terminated in 360-degree brass EMC glands.
Can FEP-6Y multi-core control cables operate in cryogenic -100 °C chambers?
Yes — unlike PVC or standard elastomers that shatter below -40 °C, FEP-6Y retains dielectric integrity and fixed/occasional-flex toughness down to -100 °C.
What is the minimum order quantity and delivery lead time for FEP-6Y and FEP-C-6Y?
300 m per cross-section on continuous melt-extruded wooden or plywood export reels, with a factory production lead time of 7 to 45 working days.
FEP-6Y & FEP-C-6Y Dimensional & Weight Schedule (0.25–6 mm²)
FEP-6Y & FEP-C-6Y Key Voltage, Thermal & Reel Summary
- Full FEP-6Y core & jacket build: Both core insulation and outer sheath use DIN VDE 0207-6 Type 6Y fluorinated ethylene propylene for total acid, solvent, oil and steam immunity
- Unscreened & EMC-braided options: Available as compact unscreened FEP-6Y or >= 85 % tinned/silver-plated copper braided FEP-C-6Y for VFD, thermocouple-zone and PLC immunity
- Extreme -100 °C to +205 °C span: Operates continuously from -100 °C cryogenic cold rooms up to +180 °C (tinned Cu) or +205 °C (silver-plated Cu, +230 °C short-term peak)
- Slim OD & PWIS/silicone-free: 30 % to 40 % smaller outer diameter than equivalent SiHF silicone cables (e.g. 4G1.5 mm² is just 6.3 mm OD) and 100 % silicone-free
- Industrial production reels: Supplied in 300 m minimum order production reels (continuous melt-extruded lengths) with a 7 to 45 working days factory lead time
| Parameter | Value |
|---|---|
| Rated voltage | 600 V nominal (300/500 V VDE 0298 class) with 2500 V AC 50 Hz routine dielectric withstand test and at least 2 GOhm*km insulation resistance |
| Core count and cross-section range | 2 to 25 cores from 0.25 mm2 to 2.5 mm2 plus 3G4 to 5G16 mm2 hot-zone motor feeders in IEC 60228 Class 5 tinned or silver-plated copper |
| Insulation, screen and outer sheath | Full DIN VDE 0207-6 Type 6Y FEP core insulation and FEP outer sheath, unscreened (FEP-6Y) or with 85% tinned/silver copper braid (FEP-C-6Y) |
| Operating temperature and bend radius | -100 C to +180 C (tinned copper) or +205 C continuous / +230 C peak (silver-plated copper); 4x OD fixed and 10x to 15x OD flexing bend radius |
| Standard put-up and lead time | 300 m minimum order continuous melt-extruded factory reels manufactured in 7 to 45 working days |
| Flame and chemical resistance | Non-flammable and self-extinguishing per IEC 60332-1-2; impervious to acids, alkalis, oils, fuels, solvents and 1 Mrad radiation |
| Silicone-free manufacturing | 100% free of silicone and lacquer-wetting-impairment substances (PWIS/LABS-free) for coating and cleanroom installations |
FEP-6Y & FEP-C-6Y Multi-Core Dimensional & Weight Schedule
| Model & Core Size | FEP-6Y Nom. OD (mm) | FEP-C-6Y Screened OD (mm) | FEP-6Y Cu Index (kg/km) | FEP-6Y Weight (kg/km) | FEP-C-6Y Weight (kg/km) | Standard Reel MOQ | Next step |
|---|---|---|---|---|---|---|---|
| FEP-6Y / FEP-C-6Y 2x0.25 mm² | 3.3 | 3.9 | 5.0 | 17 | 26 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 4G0.25 mm² | 3.8 | 4.4 | 10.0 | 27 | 38 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 2x0.5 mm² | 3.9 | 4.5 | 9.8 | 21 | 33 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 3G0.5 mm² | 4.1 | 4.7 | 14.7 | 32 | 45 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 4G0.5 mm² | 4.7 | 5.3 | 19.6 | 44 | 59 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 7G0.5 mm² | 5.6 | 6.3 | 34.3 | 70 | 91 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 2x0.75 mm² | 4.3 | 4.9 | 14.4 | 31 | 45 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 3G0.75 mm² | 4.8 | 5.4 | 21.6 | 46 | 62 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 4G0.75 mm² | 5.3 | 6.0 | 29.0 | 58 | 77 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 7G0.75 mm² | 6.3 | 7.0 | 50.0 | 92 | 116 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 3G1.0 mm² | 5.2 | 5.9 | 29.0 | 55 | 73 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 4G1.0 mm² | 5.7 | 6.4 | 38.0 | 71 | 92 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 7G1.0 mm² | 6.8 | 7.6 | 67.0 | 113 | 141 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 12G1.0 mm² | 8.0 | 8.8 | 115.2 | 220 | 258 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 2x1.5 mm² | 5.1 | 5.8 | 29.0 | 45 | 64 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 3G1.5 mm² | 5.8 | 6.5 | 43.0 | 70 | 92 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 4G1.5 mm² | 6.3 | 7.1 | 58.0 | 98 | 124 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 5G1.5 mm² | 7.1 | 7.9 | 72.0 | 117 | 147 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 7G1.5 mm² | 7.8 | 8.6 | 101.0 | 184 | 218 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 12G1.5 mm² | 10.2 | 11.1 | 173.0 | 326 | 374 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 18G1.5 mm² | 12.3 | 13.3 | 260.0 | 504 | 565 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 25G1.5 mm² | 14.0 | 15.1 | 360.0 | 682 | 756 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 4G2.5 mm² | 7.3 | 8.1 | 96.0 | 182 | 215 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 5G2.5 mm² | 7.9 | 8.8 | 120.0 | 240 | 278 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 4G4.0 mm² | 8.7 | 9.6 | 154.0 | 304 | 348 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 5G4.0 mm² | 9.7 | 10.7 | 192.0 | 386 | 436 | 300 m reel | Request this size |
| FEP-6Y / FEP-C-6Y 4G6.0 mm² | 10.8 | 11.8 | 230.4 | 445 | 506 | 300 m reel | Request this size |
ASCII part references for BOM and ERP entry: TF-FEP6Y-3G1.5, TF-FEP6Y-4G1.5, TF-FEP6Y-5G1.5, TF-FEP6Y-12G1.5, TF-FEPC6Y-4G0.75, TF-FEPC6Y-4G1.5, TF-FEPC6Y-4G2.5, TF-FEPC6Y-4G4.
G denotes inclusion of a green-yellow protective earth core; x (OZ) denotes all-numbered/coloured cores without earth. Custom PFA-insulated +260 °C builds available on 300 m reels.
FEP-6Y & FEP-C-6Y DIN VDE 0207-6 & IEC Reference Standards
| Standard or specification | Application |
|---|---|
| DIN VDE 0207-6 & DIN VDE 0295 / IEC 60228 Class 5 | Type 6Y fluorinated ethylene propylene insulation and outer jacket compound over fine-stranded Class 5 copper conductors. |
| DIN VDE 0293-308 | Core identification via colour code on 0.25 mm² and white numeral printing on black cores plus green-yellow earth on >= 0.5 mm². |
| IEC 60332-1-2 / EN 60332-1-2 | Self-extinguishing vertical flame-retardant performance with non-dripping fluoropolymer char resistance. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and routine 2,500 V AC test records
IEC 60228 — Conductors of insulated cables (Class 5)
IEC 60332-1-2 — Vertical flame propagation test for insulated cables
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
FFCT Fluoroplastic Cable 600 V 200°C
A related cable option for a different application or duty profile.
View productSiHF & SiHF-J Multi-Core Flexible Silicone Cable (300/500 V, 180 °C)
A related cable option for a different application or duty profile.
View productSiHFC & SiHF-C-Si EMC Screened Silicone Cable (300/500 V, 180 °C)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.