IEC 62613 Shore-to-Ship (AMP / Cold Ironing) High-Voltage Port Reeling Cable (6.6 / 11 kV)
High-voltage shore-to-ship connection (HVSC / AMP / Cold Ironing) reeling cables rated 6/10 (12) kV (for 6.6 kV berth systems) and 8.7/15 (17.5) kV (for 11 kV berth systems), engineered for containerized shore-power dispenser reels, quay-side cable management cranes and shipboard AMP reels. Manufactured under Jiangsu Tebaoflex Special Cable Co., Ltd.'s ISO 9001:2015 certified production scope explicitly naming shore-to-ship power connection reeling cables.
High-Voltage Shore Connection (HVSC)—also referred to as Alternative Maritime Power (AMP) or Cold Ironing—allows container vessels, cruise ships, Ro-Ro carriers and LNG tankers to shut down auxiliary diesel generators at berth and draw 6.6 kV or 11 kV shore power throughIEC 62613-2 plugs and motorized cable management reels. Because the cable is repeatedly deployed between the quay or barge reel and the vessel receiving cubicle, it requires flexible Class 5 tinned-copper conductors, integrated pilot/optical control circuits and a marine-grade outer jacket.
Jiangsu Tebaoflex Special Cable Co., Ltd. holds valid ISO 9001:2015 certification (certificate no. 244-24-QI-17425-R0-Q, valid through 2027-12-17) whose certified production scope explicitly names reeling cables for shore-to-ship power connection (岸电连接), alongside ISO 14001:2015 (cert. 033825E01477R1SXSNIEY) and ISO 45001:2018 (cert. 033825S01277R1SEJOTLU) covering the sales and management of shore-to-ship connection cables.
Designed in accordance with IEC/IEEE 80005-1, IEC 62613-1 / IEC 62613-2 and DIN VDE 0250-813, each cable integrates three triple-extruded +90 °C EPR medium-voltage power cores (35 mm² to 185 mm²), one or two concentric/interstitial earth conductors, pilot control cores for safety-loop interlocks and an optional metal-free fibre-optic subunit for ship-to-shore PLC communication, all protected by an anti-torsion braid and a saltwater-, oil- and UV-resistant polychloroprene (5GM5) or halogen-free SHF2 elastomer jacket.
Confirm your vessel/berth system voltage (6.6 kV or 11 kV), single-cable vs. parallel-cable ampacity requirement, IEC 62613 coupler pinout (pilot core or fibre-optic count) and dispenser reel dimensions when requesting a quotation. TEBAOFLEX supplies custom shore-to-ship reeling lengths from a 50 m minimum order quantity with a standard lead time of 7–45 working days.
Explore the port and festoon cable range for related configurations.
For related berth shore-power dispensers and medium-voltage port crane reeling cables, compare these specifications: (N)TSCGEW11Y 6/10 kV Shore Power Reeling Cable (for halogen-free PUR-sheathed 6/10 kV berth and mobile dispenser reeling); STS (Ship-to-Shore) Quay Crane Main Drum & Spreader Reeling Cable (0.6/1–20 kV) (for high-speed container quay crane main drum and spreader reeling up to 20 kV). Verify pilot-core allocation, integrated optical fibres, and berth voltage before ordering.
Construction
The representative construction illustrates 6/10 (12) kV 3×95 + 1G50 + 4×2.5 mm² Shore-to-Ship AMP Reeling Cable: three Class 5 flexible tinned-copper phase cores with inner semiconductive screen, +90 °C EPR insulation, outer semiconductive screen and tinned-copper composite shield, cabled with one flexible tinned-copper earth core and one jacketed pilot/control subunit in the interstitial valleys, surrounded by a light-grey inner elastomer sheath, open-weave anti-torsion aramid braid and a black marine-grade 5GM5 polychloroprene outer sheath.

| Component | Material and construction |
|---|---|
| Phase conductors | Three Class 5 extra-flexible rope-lay stranded tinned copper conductors per IEC 60228 (35 mm² to 185 mm²), corrosion-protected for marine atmosphere. |
| Triple-extruded MV dielectric | Extruded inner semiconductive layer, +90 °C ozone-resistant ethylene-propylene rubber (EPR) insulation (3.4 mm for 6/10 kV; 4.5 mm for 8.7/15 kV) and extruded outer semiconductive screen. |
| Metallic phase shield | Combined tinned-copper wire and synthetic-fibre braid/spiral shield over each phase core for earth-fault current conduction. |
| Earth & pilot / fibre-optic elements | Flexible tinned-copper protective earth conductor (25 mm² to 95 mm²) plus pilot control subunit (such as 2×2.5 or 4×2.5 mm²) or 6–24 core G50/125 / E9/125 fibre-optic module. |
| Inner sheath & anti-torsion braid | Extruded light-grey 5GM3 elastomeric inner sheath and high-tenacity aramid anti-torsion braid to withstand vertical ship-side suspension and horizontal quay reeling. |
| Marine outer jacket | Heavy-duty black polychloroprene (PCP / 5GM5) or halogen-free cross-linked elastomer (SHF2 per IEC 60092-360) resistant to seawater immersion, fuel oil, solar UV and abrasion. |
Applications
Select 6/10 (12) kV cables for 6.6 kV container and Ro-Ro shore power systems, or 8.7/15 (17.5) kV cables for 11 kV cruise ship and high-capacity container terminal HVSC installations.

- Quay-side containerized AMP / Cold Ironing cable dispenser reels and jib-arm cable management systems at container and cruise terminals.
- Shipboard HVSC motorized cable reels installed inside container vessel and Ro-Ro carrier shore-power receiving rooms.
- Mobile dockside cable reel trailers and floating power-barge to vessel high-voltage shore connections.
- Direct termination into IEC 62613-2 high-voltage shore connection plugs and sockets with integrated safety pilot interlocks.
For container terminal shore-power vaults, mobile cable dispensers, and vessel-side CMS reels, review these solutions: Port & Container Crane Cable Solutions (for complete berth, quay crane, and container yard electrification engineering); E-RTG & Automated Container Crane (ASC / RMG) High-Speed Reeling Cable (0.6/1–20 kV) (for automated stacking crane and electric RTG high-speed drum reeling up to 20 kV). Confirm plug compatibility under IEC 62613, seawater-oil resistance, and drum bending radius.
Specifications
| Parameter | Value |
|---|---|
| Rated voltage (U0/U (Um)) | 6/10 (12) kV for 6.6 kV HVSC systems; 8.7/15 (17.5) kV for 11 kV HVSC systems |
| Maximum continuous conductor temperature | +90 °C (+250 °C short-circuit, 5 s max.) |
| Ambient operating temperature | -35 °C to +80 °C (marine dockside and shipboard reel service) |
| Permissible dynamic tensile load | 25 N/mm² of total power copper cross-section |
| Minimum dynamic bending radius | 10 × to 12 × cable outside diameter |
| Marine environmental resistance | Saltwater, oil (EN 60811-404), ozone, UV and flame-retardant per IEC 60332-1-2 / IEC 60332-3-22 |
| Certified quality & environmental systems | ISO 9001:2015 cert. 244-24-QI-17425-R0-Q (production of shore-to-ship reeling cables); ISO 14001 cert. 033825E01477R1SXSNIEY & ISO 45001 cert. 033825S01277R1SEJOTLU (sales of shore-to-ship connection cables) |
| Commercial supply terms | Minimum order quantity 50 m; manufacturing lead time 7–45 working days |
| HVSC system & cable voltage grade | Nominal configuration (power + earth + pilot/FO, mm²) | Nominal insulation thickness (mm) | Nominal outside diameter (mm) | Max. dynamic tensile load (N) | Continuous ampacity at 45 °C marine ambient (A) | Approx. weight (kg/km) |
|---|---|---|---|---|---|---|
| 6.6 kV HVSC (6/10 kV) | 3×35 + 1G25 + 4×2.5 | 3.4 | 45.8 | 2,625 | 152 | 3,280 |
| 6.6 kV HVSC (6/10 kV) | 3×50 + 1G25 + 4×2.5 | 3.4 | 49.4 | 3,750 | 185 | 4,020 |
| 6.6 kV HVSC (6/10 kV) | 3×70 + 1G35 + 4×2.5 | 3.4 | 53.8 | 5,250 | 229 | 5,080 |
| 6.6 kV HVSC (6/10 kV) | 3×95 + 1G50 + 4×2.5 | 3.4 | 58.6 | 7,125 | 277 | 6,390 |
| 6.6 kV HVSC (6/10 kV) | 3×120 + 1G70 + 4×2.5 | 3.4 | 62.8 | 9,000 | 322 | 7,680 |
| 6.6 kV HVSC (6/10 kV) | 3×150 + 1G70 + 4×2.5 | 3.4 | 67.2 | 11,250 | 367 | 9,010 |
| 6.6 kV HVSC (6/10 kV) | 3×185 + 1G95 + 4×2.5 | 3.4 | 72.0 | 13,875 | 418 | 10,680 |
| 11 kV HVSC (8.7/15 kV) | 3×35 + 1G25 + 4×2.5 | 4.5 | 50.2 | 2,625 | 154 | 3,760 |
| 11 kV HVSC (8.7/15 kV) | 3×50 + 1G25 + 4×2.5 | 4.5 | 53.8 | 3,750 | 188 | 4,540 |
| 11 kV HVSC (8.7/15 kV) | 3×70 + 1G35 + 4×2.5 | 4.5 | 58.2 | 5,250 | 233 | 5,640 |
| 11 kV HVSC (8.7/15 kV) | 3×95 + 1G50 + 4×2.5 | 4.5 | 63.0 | 7,125 | 281 | 6,990 |
| 11 kV HVSC (8.7/15 kV) | 3×120 + 1G70 + 4×2.5 | 4.5 | 67.2 | 9,000 | 326 | 8,320 |
| 11 kV HVSC (8.7/15 kV) | 3×150 + 1G70 + 4×2.5 | 4.5 | 71.6 | 11,250 | 372 | 9,710 |
| 11 kV HVSC (8.7/15 kV) | 3×185 + 1G95 + 4×2.5 | 4.5 | 76.4 | 13,875 | 424 | 11,420 |
| 11 kV HVSC + FO (8.7/15 kV) | 3×70 + 2G25 + 12FO | 4.5 | 58.8 | 5,250 | 233 | 5,710 |
| 11 kV HVSC + FO (8.7/15 kV) | 3×95 + 2G25 + 12FO | 4.5 | 63.4 | 7,125 | 281 | 7,040 |
| 11 kV HVSC + FO (8.7/15 kV) | 3×120 + 2G35 + 12FO | 4.5 | 67.6 | 9,000 | 326 | 8,380 |
Continuous current ratings are stated at +90 °C conductor temperature and +45 °C marine ambient air (IEC/IEEE 80005-1 reference); apply drum layer derating when multiple layers remain wound on the AMP reel during operation.
ISO 9001:2015 certificate 244-24-QI-17425-R0-Q is held by Jiangsu Tebaoflex Special Cable Co., Ltd. for the production of reeling cables including shore-to-ship power connection; ISO 14001 and ISO 45001 certificates cover the sales and related management activities of shore-to-ship connection cables.
Both pilot-core configurations (e.g., + 2×2.5 or 4×2.5 mm²) and hybrid fibre-optic configurations (+ 12FO / 24FO) are available to match the shore-power switchgear design.
Standards
| Standard or specification | Application |
|---|---|
| IEC/IEEE 80005-1 | Utility connections in port — Part 1: High Voltage Shore Connection (HVSC) systems — general requirements for 6.6 kV and 11 kV shore-to-ship power cables. |
| IEC 62613-1 & IEC 62613-2 | Plugs, socket-outlets and ship couplers for high-voltage shore connection (HVSC) systems — dimensional and pilot-circuit interface compatibility. |
| DIN VDE 0250-813 | Medium-voltage flexible elastomer reeling cables for high mechanical stress. |
| ISO 9001:2015 (Cert. 244-24-QI-17425-R0-Q) | Certified quality management system for the production of shore-to-ship power connection reeling cables (Jiangsu Tebaoflex Special Cable Co., Ltd.). |
IEC/IEEE 80005-1 High Voltage Shore Connection Standard Reference
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
(N)TSCGEW11Y 6/10 kV Shore Power Reeling Cable
A related cable option for a different application or duty profile.
View productStacker-Reclaimer & Bucket-Wheel Excavator Drum Reeling Cable (0.6/1–35 kV)
A related cable option for a different application or duty profile.
View product(N)TSCGEH3S Cable 3.6/6 kV and 6/10 kV Luminescent Mining Trailing Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.