Submersible Pump Cables TEBAOFLEX

Li-09YSCH PiMF-100 Cat. 5 Submersible Pump Data Cable

Li-09YSCH PiMF-100 is a 100/100 V four-pair screened data cable for submersible pump sensors and monitoring equipment in contaminated water.

  • Tinned flexible copper conductors, Class 6.
  • Foam-skin polypropylene insulation.
  • Individual foil pair screens and an overall tinned-copper braid.
  • XL copolymer outer sheath.
  • Cat. 5 / Class D transmission reference up to 100 MHz.

Send the controller interface, pair assignment, cable length, entry drawing and water conditions for a technical quotation.

Product information
Brand
TEBAOFLEX
Product overview

Li-09YSCH PiMF-100 Data Connections for Submersible Pumps

Li-09YSCH PiMF-100 is a 100/100 V screened data cable for pumps with integrated sensors and monitoring equipment in contaminated water under medium mechanical stress. Four signal pairs combine foam-skin polypropylene insulation, individual aluminium-coated foil screens and an overall tinned-copper braid inside an XL copolymer sheath.

The paired construction keeps each signal circuit identifiable through the pump entry and control cabinet. The Cat. 5 transmission reference corresponds to Class D channel characteristics up to 100 MHz. Select the complete data connection with the controller interface, connector layout and installed length; maintain the pair assignment and twist through the termination.

  • Match the data circuit: provide the sensor interface, pair allocation, impedance requirement and connection drawing.
  • Plan both screen levels: coordinate the individual pair foils and overall braid with the equipment’s termination design.
  • Design the wet-to-dry transition: select the cable-entry seal, supported bend and dry enclosure connection together.

Specify motor-power and data circuits separately, including their routing and entry arrangements. Effective screening requires good braid contact to ground at both cable ends. Use the separate fixed and flexible bend factors, and support the cable independently of the pump lifting system. Include water chemistry, cleaning media and installed length with the enquiry. Immersion depth and the permitted water-temperature limit are confirmed for the specified project.

For Li-09YSCH pump connections, explore the submersible pump cable range; for Li-09YSCH conductor surface selection, read the tinned copper comparison.

Construction

Construction

The PiMF arrangement screens each of the four signal pairs individually. One common tinned-copper braid surrounds the complete paired assembly.

Li-09YSCH PiMF-100 cross-section with eight PP-insulated cores in four foil-screened pairs
Representative four-pair Li-09YSCH PiMF-100 arrangement with one foil screen per pair and an overall tinned-copper braid.
Li-09YSCH PiMF-100 four-pair construction
ParameterValue or condition
Cable formRound four-pair assembly: eight insulated signal conductors.
ConductorTinned finely stranded copper, Class 6 according to DIN EN 60228.
Core insulationFoam-skin polypropylene (PP).
Pair identificationWhite/orange–orange, white/green–green, white/brown–brown and white/blue–blue.
Pair screensEach pair has its own aluminium-coated foil screen.
Overall screenTinned-copper wire braid around the four screened pairs.
Outer sheathCross-linked copolymer (XL copolymer).
Li-09YSCH PiMF-100 pair identification
PairCore colours
Pair 1White/orange and orange
Pair 2White/green and green
Pair 3White/brown and brown
Pair 4White/blue and blue
Applications

Applications

Data and sensor connections for modern submersible pumps, wastewater tanks and process-water equipment under medium mechanical stress, including supported indoor and outdoor routes.

Li-09YSCH PiMF-100 data cable in a supported wastewater pump monitoring connection
Application illustration: supported data-cable routing between wastewater-pump monitoring equipment and a dry control enclosure.
Li-09YSCH PiMF-100 connection planning
ParameterValue or condition
Data interfaceSpecify controller protocol, pair assignment, impedance requirement, channel length and connector layout.
Pair preparationMaintain the pair identification and twist to the equipment termination; coordinate foil breakout with the entry drawing.
Overall braid terminationProvide effective braid contact to ground at both cable ends, with coordinated gland and enclosure bonding.
Cable entryMatch the selected finished dimensions, sealing profile and strain relief to the pump drawing.
Bending and supportUse 6 × maximum OD for fixed installation and 10 × maximum OD for flexible use; provide independent cable supports.
Power and data routingCoordinate the signal route and the separate motor-power connection with the complete equipment layout.
Water chemistryState the actual water composition, treatment chemicals and cleaning media for material selection.
Project water dutyConfirm immersion depth and the permitted maximum water temperature with the project enquiry.
Specifications

Specifications

Li-09YSCH PiMF-100 data-cable selection summary
ParameterValue
Rated voltage100/100 V
Pair arrangement4 × 2
ConductorTinned flexible copper, Class 6
InsulationFoam-skin polypropylene
ScreenIndividual pair foil screens and overall tinned-copper braid
Li-09YSCH PiMF-100 electrical and installation profile
ParameterValue or condition
Rated voltage100/100 V
Maximum AC operating voltage300 V
AC test voltage1000 V / 1 minute
Pair arrangement4 × 2 insulated signal cores
ConductorTinned finely stranded copper, Class 6
Core insulationFoam-skin polypropylene (PP)
Individual pair screensAluminium-coated foil around each pair
Overall screenTinned-copper wire braid
Outer sheathXL copolymer
Transmission referenceCat. 5; transmission Class D according to EN 50173-1; channel frequency band up to 100 MHz
Maximum conductor temperature90 °C
Short-circuit conductor temperature250 °C
Minimum ambient temperature — fixed installation−40 °C
Minimum ambient temperature — flexible use−25 °C
Maximum tensile load on the conductor15 N/mm²
Minimum bending radius — fixed installation6 × maximum cable OD
Minimum bending radius — flexible use10 × maximum cable OD
Project water dutyConfirm immersion depth and the permitted maximum water temperature with the project enquiry.

Specify the required conductor cross-section, finished cable dimensions, installed length and entry seal together with the complete data-channel layout.

Standards

Standards

Li-09YSCH PiMF-100 construction and transmission references
ReferenceApplication
EN 50525-2-21Construction and water-resistance reference.
EN 50173-1Transmission Class D reference for a channel frequency band up to 100 MHz.
DIN EN 60228 / IEC 60228Class 6 conductor reference.
DIN EN 60332-1-2Single-cable flame-propagation test reference.
DIN EN 60811-404Oil-resistance test reference.
DIN EN 50565-2General cable-use and installation guidance.

For conductor classes, see the IEC 60228 standard scope.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.