Submersible Pump Cables TEBAOFLEX

Submersible Pump Data and Control Hybrid Cable 300/500 V

This submersible pump data and control hybrid cable combines four 0.5 mm² control conductors with two 22 AWG data pairs in one screened assembly. The cable family is rated 300/500 V and serves pump monitoring, control supply and network communication.

  • 300/500 V cable family
  • EPR control insulation, PE data insulation, dual shielding and a cross-linked copolymer sheath
  • Plain flexible copper, Class 5
  • 90 °C maximum conductor temperature, cable-family reference

Send the configuration, motor or controller drawing, installed length and entry dimensions for a technical quotation.

Product information
Brand
TEBAOFLEX
Product overview

Submersible pump data and control hybrid cable for Pump Connections

This submersible pump data and control hybrid cable combines four 0.5 mm² control conductors with two 22 AWG data pairs in one screened assembly. The cable family is rated 300/500 V and serves pump monitoring, control supply and network communication.

The two circuit groups remain electrically and mechanically distinct. The four outer control conductors provide a supply pair and a winding-temperature-monitor pair in the illustrated pump interface. A separately screened inner data cable carries the two network pairs. Its PE-insulated conductors sit inside a TPU sheath, with foil and braid shielding; a second overall braid surrounds the hybrid assembly.

Select the cable with the controller pin assignment, pair identification and entry dimensions in hand. The illustrated configuration has an approximate 13.5 mm outside diameter and an 81 mm bend radius in the equipment connection. Check the entry seal and the space for separating control and data cores before cutting back the sheath. Support the hybrid cable independently alongside the pump route.

The 24 VDC supply and the PTC monitor voltage describe device circuits, while 300/500 V describes the cable-family rating. Keep those values separate when specifying insulation, testing and terminations. Confirm the network interface and complete channel arrangement with the equipment drawing, including screen contact and the transition into the control cabinet.

  • Identify supply, PTC monitoring and network pairs separately.
  • Preserve both shielding levels through the specified termination.
  • Coordinate the cable entry and control/data breakout with the equipment drawing.

Selection resources: submersible pump cable range · conductor material guide.

Construction

Construction

EPR control insulation, PE data insulation, dual shielding and a cross-linked copolymer sheath. The representative image follows the selected configuration; other sizes retain their stated core arrangement.

Pump hybrid cable cross-section with four control cores around a separately screened two-pair data unit
Representative Submersible pump hybrid 4×0.5 ST + 2×2×22 AWG construction; configuration-specific dimensions are tabulated separately.
Submersible pump data and control hybrid cable layer schedule
LayerConstruction
ConductorsPlain fine-stranded copper, Class 5. Four 0.5 mm² control cores plus two 22 AWG data pairs.
Control insulationEPR rubber; numbered control cores around the data subcable.
Data insulationPE; white/blue receiving pair and yellow/orange transmitting pair in the illustrated interface.
Data screenAluminium-coated foil and tinned-copper braid.
Data inner sheathTPU around the screened data subcable.
Overall screenTinned-copper braid around the combined control and data assembly.
Outer sheathCross-linked copolymer. No protective-earth or optical-fibre core.
Applications

Applications

This submersible pump data and control hybrid cable combines four 0.5 mm² control conductors with two 22 AWG data pairs in one screened assembly. The cable family is rated 300/500 V and serves pump monitoring, control supply and network communication.

Separate slender data-control and heavier motor cable routes at a wastewater pump and closed instrumentation cabinet
Application illustration: independently supported electrical cable route and a separate pump lifting arrangement.
Submersible pump data and control hybrid cable selection checkpoints
Selection pointWhat to coordinate
Supply pairControl cores 1 (+) and 2 (−): 24 VDC device supply; 12–30 V FELV, maximum 4.5 W.
Winding monitoringControl cores 3 and 4: PTC monitoring circuit, 2.5–7.5 VDC.
Receiving pairWhite RD+ and blue RD− in the illustrated pump interface.
Transmitting pairYellow TD+ and orange TD− in the illustrated pump interface.
Breakout and screenPrepare the data termination in the cabinet and preserve both screen contacts. No connector is included by the cable designation.

Confirm immersion depth and the maximum permitted water temperature with the enquiry. Support the cable independently; use a separate mechanical system to lift the pump.

Specifications

Specifications

Keep the exact configuration and its installation conditions together when selecting the cable entry and route.

Submersible pump data and control hybrid cable technical parameters
ParameterValue
Rated voltage U₀/U300/500 V cable family
ConductorPlain flexible copper, Class 5
Insulation and sheathEPR control insulation, PE data insulation, dual shielding and a cross-linked copolymer sheath
Temperature condition90 °C maximum conductor temperature, cable-family reference
Maximum operating voltage AC, cable family318/550 V
Maximum operating voltage DC, cable family413/825 V
Maximum short-circuit conductor temperature, cable family250 °C
Family minimum ambient temperature−40 °C fixed; −25 °C flexible
Pump-interface ambient range−25 to +40 °C
Maximum tensile stress on conductor, cable family15 N/mm²
Cable-family bending reference6 × maximum OD, fixed; 10 × maximum OD, flexible
Data transmission referenceClass D to EN 50173-1; channel frequency band up to 100 MHz

Pump data/control hybrid cable Configurations

Pump data/control hybrid cable dimensions and configuration data
ConfigurationApproximate OD (mm)Device-assembly bend radius (mm)Circuit functions
Pump hybrid 4×0.5 ST + 2×2×22 AWG13.581Control supply, PTC winding monitor and two network pairs

The 81 mm radius belongs to the illustrated 13.5 mm pump-interface assembly. Cable-family bend factors remain separate fixed/flexible installation references.

Standards

Standards

The following references identify the conductor, material and test requirements relevant to this construction.

Submersible pump data and control hybrid cable standards and tests
ReferenceApplication
EN 50525-2-21Cable-family design and water-resistance reference
IEC 60228Class 5 conductor reference
EN 50173-1Class D channel transmission reference, up to 100 MHz
EN 60332-1-2Single-cable flame-test reference
EN 60811-404Oil-resistance test reference
AC voltage test2 kV AC for 15 minutes, main cores

For conductor classes, see the IEC 60228 standard scope.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.