Halogen-Free 50 Ω & 75 Ω Marine Coaxial Cable
Halogen-free flame-retardant 50 Ω and 75 Ω shipboard RF coaxial cables designed to MIL-C-17 / IEC 60092-350 electrical dimensions with SHF1 and oil-resistant SHF2 outer sheaths. Covers RG-58 C/U, RG-223/U, RG-213/U, RG-214/U, low-loss cellular-PE 2.7/7.3 AF (50 Ω) and RG-59 B/U, RG-6/U, RG-11/U and RG-12 A/U (75 Ω) for marine radar, VHF/UHF, AIS, GPS, VSAT and shipboard TV/CCTV.
Marine coaxial cables connect masthead VHF/UHF radio antennas, AIS transponders, DGPS/GNSS receivers, X-band/S-band radar transceivers, Inmarsat/VSAT satellite domes and onboard CCTV/MATV distribution networks. Standard PVC or PE commercial coaxial cables fail shipboard fire safety rules; these marine coaxial constructions replace PVC with halogen-free flame-retardant SHF1 or cross-linked oil-resistant SHF2 jackets tested to IEC 60332-1-2 and IEC 60332-3-22 Category A while preserving exact MIL-C-17 / DIN core and dielectric dimensions for standard N, BNC, TNC and UHF connectors.
The 50 Ω radio-frequency series includes compact RG-58 C/U (5.0 mm OD) and double-silver-braided RG-223/U (5.4 mm OD) for equipment rack jumpers and short cabin runs, alongside heavy-duty RG-213/U (10.3 mm OD) and double-silver-braided RG-214/U (10.8 mm OD) for mast feeders up to 3 GHz.
For long mast-to-bridge runs where standard solid-PE RG-213 attenuation is excessive, the low-loss 50 Ω 2.7/7.3 AF (9YH(ST)CH) construction uses a 2.75 mm solid copper inner conductor, 7.25 mm cellular foam-PE dielectric (85% velocity of propagation) and foil-plus-tinned-copper-braid shielding to cut signal loss in half across VHF, AIS and L-band satellite frequencies.
The 75 Ω video and satellite IF series covers RG-59 B/U (6.2 mm OD), double-screened RG-6/U (6.9 mm OD), long-haul RG-11/U (10.3 mm OD) and armoured RG-12 A/U (14.0 mm OD). Compare the dimensional and frequency-attenuation tables below and specify the RG type, 50 Ω or 75 Ω impedance, and SHF1 or SHF2 jacket grade for quotation.
Explore the marine and offshore cable range for related configurations.
Construction
The representative cutaway shows a double-braided 50 Ω RG-214/U marine coaxial cable with a 7-wire stranded silver-plated copper inner conductor, solid polyethylene dielectric core, two concentric silver-plated copper wire braid screens and a black halogen-free SHF1/SHF2 outer sheath.

| Component | Material and construction |
|---|---|
| Inner conductor | Stranded or solid bare, tinned or silver-plated copper (or copper-clad steel on RG-59) matched to the exact MIL-C-17 / DIN diameter for standard RF connector pins. |
| Dielectric insulation | Solid polyethylene (PE, velocity ratio 66%) on standard RG-58, RG-223, RG-213, RG-214 and RG-59; low-loss cellular/foamed polyethylene (Foam PE, velocity ratio 82%–85%) on 2.7/7.3 AF and RG-6. |
| Outer conductor / RF shield | Single copper braid (RG-58, RG-213, RG-59, RG-11), double silver-plated copper braids for high screening effectiveness (RG-223, RG-214), or laminated Al/PET foil tape plus tinned copper braid (2.7/7.3 AF and RG-6). |
| Outer sheath | Black UV- and weather-resistant halogen-free flame-retardant SHF1 or oil-resistant cross-linked SHF2 compound to IEC 60092-359 / IEC 60092-360. |
Applications
Select 50 Ω coaxial types for RF transmitters/antennas and 75 Ω coaxial types for baseband video, CCTV and satellite IF distribution.

- Marine VHF/UHF radiotelephone, GMDSS, AIS transponders, NAVTEX and GNSS/DGPS mast antenna feeders (50 Ω RG-213, RG-214 and low-loss 2.7/7.3 AF).
- Radar IF interconnects, bridge console RF jumpers and high-screening test leads up to 3 GHz (50 Ω double-braided RG-223 and RG-214).
- Cellular 4G/5G maritime routers, FleetBroadband and L-band satellite antenna runs requiring low attenuation over 20–50 m mast routes (50 Ω 2.7/7.3 AF).
- Shipboard analogue/HD-SDI CCTV cameras, passenger cabin MATV/CATV television distribution and Ku/Ka-band VSAT IF trunks (75 Ω RG-59, RG-6, RG-11 and armoured RG-12).
Specifications
| Parameter | Value |
|---|---|
| Characteristic impedance | 50 Ω ± 2 Ω (RG-58, RG-223, RG-213, RG-214, 2.7/7.3 AF) or 75 Ω ± 3 Ω (RG-59, RG-6, RG-11, RG-12). |
| Capacitance & velocity ratio | 50 Ω solid PE: 101 pF/m, 66% VP; 50 Ω foam PE (2.7/7.3 AF): 78 pF/m, 85% VP; 75 Ω solid/foam PE: 53–67 pF/m, 66%–82% VP. |
| Frequency range | DC up to 1 GHz (RG-58 / RG-59) and up to 3 GHz (RG-223, RG-213, RG-214, 2.7/7.3 AF, RG-6). |
| Peak operating & test voltage | Operating peak voltage 1.4 kV to 3.7 kV RMS depending on dielectric diameter; spark/dielectric test 3.0 kV to 10.0 kV RMS. |
| Sheath options | Halogen-free SHF1 (standard shipboard & weather deck) or cross-linked oil-resistant SHF2 (machinery spaces & open deck). |
| Fire & smoke compliance | IEC 60332-1-2, IEC 60332-3-22 Cat. A bunched fire test, IEC 60754-1/-2 zero halogen, IEC 61034-1/-2 low smoke. |
| Operating temperature | −30 °C to +80 °C fixed (−40 °C to +85 °C on cross-linked SHF2 builds); −15 °C minimum installation temperature. |
| Minimum bending radius | 10 × OD during installation / 5 × OD static installed. |
| Marine coaxial type | Inner conductor | Dielectric Ø & type (mm) | RF shielding structure | Nominal outer Ø (mm) | Approx. mass (kg/km) | Min. bend install / static (mm) | Impedance | Capacitance (pF/m) | Velocity (%) |
|---|---|---|---|---|---|---|---|---|---|
| RG-58 C/U Marine (50 Ω) | 19 × 0.18 mm tinned copper (0.90 mm) | 2.95 (Solid PE) | Single tinned copper braid | 5.0 | 39 | 50 / 25 | 50 ± 2 Ω | 101 | 66 |
| RG-223/U Marine Double-Screened (50 Ω) | 1 × 0.89 mm silver-plated copper | 2.95 (Solid PE) | Double silver-plated copper braids | 5.4 | 54 | 55 / 27 | 50 ± 2 Ω | 101 | 66 |
| RG-213/U Marine (50 Ω) | 7 × 0.75 mm bare copper (2.25 mm) | 7.25 (Solid PE) | Single bare copper braid | 10.3 | 156 | 105 / 52 | 50 ± 2 Ω | 101 | 66 |
| RG-214/U Marine Double-Screened (50 Ω) | 7 × 0.75 mm silver-plated copper (2.25 mm) | 7.25 (Solid PE) | Double silver-plated copper braids | 10.8 | 206 | 110 / 55 | 50 ± 2 Ω | 101 | 66 |
| Low-Loss 2.7/7.3 AF Marine (50 Ω, 9YH(ST)CH) | 1 × 2.75 mm solid bare copper | 7.25 (Foam PE) | Al/PET/Al tape + tinned copper braid | 10.3 | 135 | 105 / 52 | 50 ± 2 Ω | 78 | 85 |
| RG-59 B/U Marine (75 Ω) | 1 × 0.58 mm copper-clad steel / Cu | 3.70 (Solid PE) | Single bare/tinned copper braid | 6.2 | 56 | 62 / 31 | 75 ± 3 Ω | 67 | 66 |
| RG-6/U Marine Double-Screened (75 Ω) | 1 × 1.02 mm bare copper (18 AWG) | 4.60 (Foam PE) | Al/PET foil + tinned copper braid | 6.9 | 62 | 70 / 35 | 75 ± 3 Ω | 53 | 82 |
| RG-11/U Marine (75 Ω) | 7 × 0.40 mm tinned copper (1.20 mm) | 7.25 (Solid / Foam PE) | Single bare/tinned copper braid | 10.3 | 142 | 105 / 52 | 75 ± 3 Ω | 67 (PE) / 54 (Foam) | 66 / 82 |
| RG-12 A/U Armoured Marine (75 Ω) | 7 × 0.40 mm tinned copper (1.20 mm) | 7.25 (Solid PE) | Inner braid + galvanised steel / Cu armour | 14.0 | 310 | 140 / 70 | 75 ± 3 Ω | 67 | 66 |
| Frequency | RG-58 C/U (50 Ω) | RG-223/U (50 Ω) | RG-213/U (50 Ω) | RG-214/U (50 Ω) | Low-Loss 2.7/7.3 AF (50 Ω) | RG-59 B/U (75 Ω) | RG-6/U Foam (75 Ω) | RG-11/U (75 Ω) |
|---|---|---|---|---|---|---|---|---|
| 10 MHz | 4.6 | 4.5 | 2.0 | 1.9 | 1.1 | 3.5 | 2.1 | 1.9 |
| 50 MHz | 10.8 | 10.5 | 4.6 | 4.5 | 2.5 | 7.8 | 4.7 | 4.2 |
| 100 MHz | 15.8 | 15.2 | 6.9 | 6.7 | 3.6 | 11.2 | 6.6 | 6.1 |
| 200 MHz | 23.2 | 22.0 | 10.2 | 9.9 | 5.2 | 16.3 | 9.5 | 9.0 |
| 400 MHz | 34.5 | 32.5 | 15.2 | 14.7 | 7.6 | 23.8 | 13.7 | 13.4 |
| 800 MHz | 51.5 | 48.2 | 23.1 | 22.2 | 11.1 | 35.2 | 19.8 | 20.2 |
| 1000 MHz | 58.8 | 55.0 | 26.5 | 25.4 | 12.6 | 40.1 | 22.4 | 23.1 |
| 1500 MHz | — | 70.2 | 34.2 | 32.6 | 15.9 | — | 28.0 | 29.8 |
| 2000 MHz | — | 83.5 | 41.0 | 39.0 | 18.8 | — | 32.8 | 35.8 |
| 2400 MHz | — | 93.2 | 46.1 | 43.8 | 21.0 | — | 36.2 | 40.2 |
| 3000 MHz | — | 107.0 | 53.2 | 50.5 | 24.0 | — | 41.0 | 46.5 |
All marine RG coaxial cables maintain standard MIL-C-17 core and dielectric diameters (e.g., 2.95 mm dielectric on RG-58/RG-223 and 7.25 mm dielectric on RG-213/RG-214/2.7-7.3 AF/RG-11), ensuring direct compatibility with standard crimp and clamp N, BNC, TNC and UHF connectors.
For high-power transmitters or RF runs routed parallel to radar waveguide/power feeders, select double-braided silver-plated RG-223/U or RG-214/U (screening attenuation ≥ 75–85 dB) or foil-plus-braid 2.7/7.3 AF (≥ 90 dB).
For pressure-rated subsea coaxial tethers, ROV video links or hydrophone arrays operating underwater, refer to our dedicated Underwater Coaxial Cable page.
Standards
| Standard or specification | Application |
|---|---|
| MIL-DTL-17 (MIL-C-17) & IEC 61196-1 | Dimensional, impedance and radio-frequency transmission reference standards for RG-series coaxial communication cables. |
| IEC 60092-350 & IEC 60092-359 / -360 | Shipboard electrical and electronic cable test methods and halogen-free SHF1 / cross-linked SHF2 sheathing compounds. |
| IEC 60332-1-2 & IEC 60332-3-22 (Cat. A) | Single-cable vertical flame propagation test and bunched vertical flame spread test (Category A). |
| IEC 60754-1 / -2 & IEC 61034-1 / -2 | Halogen-free gas emission, low acidity/conductivity and low smoke opacity verification. |
IEC 61196-1 coaxial communication cable electrical test methods scope
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Underwater Coaxial Cable - 50/75 Ohm PUR Options
A related cable option for a different application or duty profile.
View productHalogen-Free Cat5e–Cat7 Marine Ethernet Cable
A related cable option for a different application or duty profile.
View productLSZH SHF1 Shipboard Marine Fibre Optic Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.