MINING & TUNNELING CABLES TEBAOFLEX

Mining Cap Lamp Cable — 2 × 1 mm² Battery Lead

Two-core mining cap lamp cable for a 4 V, 1 A battery-to-headlamp connection. The 2 × 1 mm² construction combines flexible tinned copper conductors, EPDM insulation, a central textile strainer and a heavy-duty chloroprene sheath, with a 500 V dielectric-test reference.

Product information
Brand
TEBAOFLEX
Product overview

Mining cap lamp cable connects a miner’s battery pack to the helmet-mounted lamp. This two-core 2 × 1 mm² design is intended for standard 4 V, 1 A headcap lamp circuits. Fine-stranded tinned copper conductors, EPDM core insulation and a heavy-duty chloroprene outer sheath form a compact flexible lead for repeated handling.

The two insulated cores are laid up around a central flexible strainer. This internal support element is separate from the electrical conductors and helps maintain the cable assembly under mechanical stress. The nominal conductor diameter is 1.30 mm, while the finished cable outside diameter is 8.7–8.8 mm. These dimensions provide a useful starting point for choosing lamp entries, battery-pack glands and strain-relief components.

Cable selection should follow the complete lamp assembly. Match the battery and lamp connections, polarity, finished lead length and routing around the wearer’s clothing and protective equipment. The 44 mm minimum bending radius applies to the listed construction; allow smooth bends at the battery enclosure and lamp entry rather than concentrating movement at a sharp exit.

The 500 V value is the cable’s dielectric-test reference, separate from the 4 V lamp supply. For procurement, provide the cap-lamp model, terminal drawing, required length and assembly requirements so the cable can be specified with the correct electrical connection and mechanical fit.

Explore the mining and tunneling cable range for related configurations.

For fixed and mobile extra-low-voltage signaling and illumination circuits along underground faces, compare these mining cables: Longwall Signal and Mine Lighting Cable — 50 V / 110 V (for 50 V and 110 V longwall face signaling and roadway luminaire feeder runs); 2YSLGCGOEU 250/250 V Signal and Control Cable (for 250/250 V overall-copper-screened multi-core signal and telemetry cables). Verify conductor cross-section, cord outer diameter for lamp gland entry, and flex-life requirements before ordering.

Construction

Construction

Exactly two insulated electrical cores are laid up around a central flexible textile strainer. The central strainer is a mechanical support element, not an additional conductor.

Two-core mining cap lamp cable cross-section showing red and black insulated conductors, a central nonmetallic textile strainer and a round chloroprene sheath
Representative cable construction.
Mining Cap Lamp Cable — 2 × 1 mm² Battery Lead construction
ComponentMaterial and construction
Conductors2 × 1 mm² electrolytic tinned copper conductors, IEC 60228 Class 5; each conductor has 32 strands of 0.201 mm diameter.
Core insulationEPDM insulation on each conductor.
Lay-up and supportThe two insulated cores are helically laid around a central flexible textile strainer.
Outer sheathHeavy-duty black chloroprene rubber sheath.
Applications

Applications

Use this flexible two-core lead between the battery pack and headcap lamp of a compatible 4 V, 1 A mining lamp assembly.

Miner helmet with cap lamp and a black flexible cable routed with broad bends to a separate battery pack on a clean lamp-room workbench
Application illustration.
  • Battery-to-headlamp interconnection for standard 4 V, 1 A mining cap lamps.
  • Flexible replacement leads where the lamp and battery interfaces match the 2 × 1 mm² cable construction.
  • Cap-lamp assembly and maintenance requiring an 8.7–8.8 mm cable outside diameter.
  • Wearable lamp cable routing with secure strain relief and bends of at least 44 mm radius.
  • Specify the completed lamp assembly and its applicable mine-use requirements, including cable entry, termination and mechanical retention.

For broader underground mining cable classifications and heavy-duty mobile face power leads, consult these references: What Is a Mining Cable? (explaining construction differences between personal cords, signal cables, trailing feeders, and armoured shaft cables); NSSHOU / (N)SSHÖU O/J, 3E and 3E + ST 0.6/1 kV Heavy-Duty Rubber Cable (for 0.6/1 kV heavy-duty polychloroprene rubber power and control cables with optional earth-check cores). Check chemical/oil exposure, tensile strain relief, and outer sheath tear strength.

Specifications

Specifications

Mining Cap Lamp Cable — 2 × 1 mm² Battery Lead technical data
ParameterValue
Lamp operating condition4 V, 1 A battery-fed headcap lamp circuit.
Dielectric-test reference500 V.
Core configuration2 × 1 mm².
ConductorTinned copper, IEC 60228 Class 5; 32/0.201 mm.
Insulation / sheathEPDM insulation / heavy-duty chloroprene sheath.
Central supportFlexible textile strainer.
Overall diameter8.7–8.8 mm.
Minimum bending radius44 mm.
Mining cap lamp cable — 2 × 1 mm² configuration and dimensions
ConfigurationStranding (number/mm)Nominal conductor diameter (mm)Overall diameter, min.–max. (mm)Minimum bending radius (mm)Approx. weight (kg/km)Copper weight (kg/km)
Mining Cap Lamp Cable 2 × 1 mm²32/0.2011.308.7–8.84414020
Mining cap lamp cable — electrical application and test condition
ParameterValue / scope
Lamp supply voltage4 V
Lamp circuit current1 A
Dielectric-test voltage500 V
Electrical conductors2 × 1 mm² tinned copper
Conductor classIEC 60228 Class 5

The 4 V, 1 A values describe the lamp application. The 500 V value is a dielectric-test reference.

The dimensional data and 44 mm bending radius apply to the listed 2 × 1 mm² construction.

The central textile strainer is a mechanical element; the cable has two electrical conductors.

Confirm terminal geometry, polarity, strain relief and completed lead length against the lamp and battery drawings.

Standards

Standards

Mining Cap Lamp Cable — 2 × 1 mm² Battery Lead standards and test references
Standard or specificationApplication
IEC 60228 Class 5Conductor construction reference for the flexible tinned copper conductors.
MGM 101/1982Technical specification reference for flexible miner’s cap-lamp cable.
Dielectric test500 V test-voltage reference for the listed cable construction.

IEC 60228 conductor standard

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.