MINING & TUNNELING CABLES TEBAOFLEX

37-102 Crush- & Impact-Resistant Shielded Mining Instrumentation Cable (0.6/1 kV TC-ER-HL, 1–24 Pairs & 1–12 Triads)

37-102 (part numbers 37-102-610 through 37-102-734) is a 0.6/1 kV crush- and impact-resistant shielded mining instrumentation cable featuring 16 AWG (1.32 mm²) 19-strand tinned copper pairs (1 to 24 pairs) or triads (1 to 12 triads), 90 °C cross-linked polyolefin insulation, individual and overall foil/drain/braid EMI shielding, an impact-absorbing polymeric inner armor layer and an MSHA flame-retardant blackCPE outer jacket.

Product information
SKU
NA-37-102-INST
Brand
TEBAOFLEX
Product overview

In mineral processing plants, preparation plants, SX-EW tankhouses, shaft stations and longwall gate roads, 4–20 mA analog loops, RTD temperature triads and HART/fieldbus instrumentation cables are exposed to falling ore, pinch points and VFD harmonic noise. Conventional metallic-armored MC-HL cables corrode or deform permanently after a single rock impact, whereas standard unarmored tray cables lack the mechanical crush rating required for exposed runs.

The 37-102 crush- and impact-resistant shielded mining instrumentation series (1 to 24 pairs in 37-102-610 through 37-102-699, and 1 to 12 triads in 37-102-668 through 37-102-734) combines 16 AWG (1.32 mm², 19×0.0117 in.) stranded tinned copper conductors and 90 °C flame-retardant cross-linked polyolefin (XLPO) insulation with a multi-stage shield and a high-modulus polymeric crush/impact barrier beneath a heavy-duty black chlorinated polyethylene (CPE) outer jacket. Single-pair (37-102-610) and single-triad (37-102-668) builds use a 100% aluminium/Mylar tape shield, tinned copper drain wire and tinned copper braid, while multi-pair and multi-triad builds add individual 100% aluminium/Mylar shields and drain wires on every numbered pair or triad.

Engineered to pass the UL 2225 crush and impact test levels of metallic-armored MC-HL cable without rigid metal armor, 37-102 is rated 0.6/1 kV, -55 °C cold bend / -40 °C cold impact to +110 °C continuous, MSHA flame-resistant, and UL 1277 TC-ER-HL on constructions up to 1.0 in. O.D. (1, 2 and 4 pairs; 1 and 4 triads) and TC-ER on 8 to 24 pairs and 8 to 12 triads.

Explore the mining and tunneling cable range for related configurations.

Construction

37-102 Shielded Mining Instrumentation Cable Construction & Crush Barrier

The representative horizontal sample shows 37-102-613 (4 Pairs 16 AWG, 0.770 in. O.D.): four numbered black/white XLPO-insulated 16 AWG tinned copper pairs with individual aluminium/polyester shields and drain wires, overall aluminium/polyester tape, tinned copper braid shield, black polymeric crush/impact barrier and outer MSHA/TC-ER-HL black CPE jacket.

Flat 2D cross-section diagram of 37-102 4-pair 16 AWG shielded mining instrumentation cable showing 19-strand tinned copper conductors, XLPO insulation, individual pair foil shields with drain wires, overall foil and tinned copper braid shield, polymeric crush barrier and CPE outer jacket
37-102 cross-section: 16 AWG tinned Cu pairs, individual & overall foil + tinned Cu braid shields, polymeric barrier and CPE jacket.
37-102 Crush- & Impact-Resistant Shielded Mining Instrumentation Cable (0.6/1 kV TC-ER-HL, 1–24 Pairs & 1–12 Triads) construction
ComponentMaterial and construction
Stranded Tinned Copper Conductors16 AWG (1.32 mm²) 19x0.0117 in. concentric-lay stranded annealed tinned copper to ASTM B33; maximum DC resistance 4.52 Ω/1000 ft at 20 °C.
XLPO Insulation & Pair/Triad CodingFlame-retardant 90 °C cross-linked polyolefin (XLPO); pairs colour-coded black and white with printed numbers (triads black, white and red).
Individual Pair/Triad Foil ShieldsOn multi-pair and multi-triad sizes, each pair/triad is wrapped with 100% coverage aluminium/polyester tape and a stranded tinned copper drain wire.
Overall Foil & Tinned Copper Braid Shield100% coverage overall aluminium/polyester tape plus tinned copper drain wire and a high-coverage tinned copper braided shield for low-frequency and high-frequency EMI immunity.
Polymeric Crush Barrier & CPE Outer JacketHigh-modulus polymeric inner crush/impact barrier bonded under a heavy-duty black thermoset/elastomeric CPE outer jacket with rip cord for clean stripping.

37-102 Part Number & Shielding Architecture Breakdown

  • 37-102: 0.6/1 kV crush- and impact-resistant shielded mining instrumentation cable series
  • -610 to -699: 16 AWG shielded twisted pair part numbers covering 1, 2, 4, 8, 12 and 24 pairs
  • -668 to -734: 16 AWG shielded twisted triad part numbers covering 1, 4, 8 and 12 triads
  • TC-ER-HL / MSHA: UL 1277 Tray Cable Exposed Run for Hazardous Locations (up to 1.0 in. O.D.) and MSHA flame compliance
  • XLPO / Al-Braid / CPE: 90 °C XLPO insulation, individual + overall foil & tinned copper braid, polymeric crush barrier and CPE jacket
Applications

37-102 Crush- & Impact-Resistant Mining Instrumentation Applications

Use 37-102 shielded pairs and triads for exposed instrumentation, PLC I/O, RTD and telemetry circuits across surface and underground mines and mineral processing facilities.

37-102 crush-resistant shielded mining instrumentation cables routed along an exposed ore-processing plant cable tray and sensor junction box
37-102 TC-ER-HL / MSHA crush-resistant shielded instrumentation cables in a mineral processing plant.
  • 4–20 mA pressure, flow, level and conveyor belt-scale transmitter loops routed in open cable trays, shaft stations and exposed equipment skids (1 to 24 pairs).
  • 3-wire Pt100 RTD bearing, stator and transformer temperature monitoring circuits on crushers, SAG/ball mills and mine hoists (1 to 12 triads).
  • Class I Division 1 / Zone 1 hazardous-location exposed runs (TC-ER-HL on 37-102-610, -611, -613, -668 and -698 under 1.0 in. O.D.) in coal prep plants and solvent extraction buildings.
  • Direct non-metallic replacement for rigid MC-HL or interlocked-armor instrumentation cables where corrosion, vibration and repeated impact occur.

37-102 vs Crush-Resistant TC-ER Power and BS 5308 Selection Boundary

37-102 Shielded Mining Instrumentation Cable compared with related mining control and instrumentation cables
ModelCore layoutShielding & mechanical barrierBest fit
37-102 Instrumentation (this page)1–24 Pairs or 1–12 Triads, 16 AWG (1.32 mm²)Ind. + overall Al/Mylar + tinned Cu braid + UL 2225 polymeric crush barrierExposed mine & mill 4–20 mA, RTD & HART loops (TC-ER-HL / MSHA)
Crush-Resistant TC-ER Power Cable3/C to 37/C, 14 AWG to 4/0 AWGUnshielded cores + polymeric crush/impact barrier + CPE jacketMine & plant 600 V / 1 kV power, lighting and motor feeders
SOOW Multi-Core Control Cable5/C to 60/C, 18 AWG to 10 AWG (600 V)Unshielded EPDM cores + CPE rubber jacket (MSHA)Flexible pendant and mobile equipment multi-core control
BS 5308 Part 1 Type 1 / Type 21–50 Pairs/Triads, 0.5–1.5 mm² (300/500 V)CAM / ICAM Al/PES tape (and SWA on Type 2)European IEC fixed plant instrumentation

Select 37-102 pairs for 2-wire 4–20 mA and differential signal loops, and 37-102 triads for 3-wire RTD temperature sensors.

Related selection resources

37-102 Shielded Mining Instrumentation Cable Frequently Asked Questions

How does 37-102 achieve MC-HL crush and impact resistance without metallic armor?

Instead of corrugated aluminium or interlocked steel armor that can pinch conductors after rockfall, 37-102 incorporates a high-durometer polymeric crush-and-impact barrier over the tinned copper braid shield and beneath the heavy-duty CPE outer jacket, rebounding elastically after passing UL 2225 MC-HL crush and impact test loads.

Which 37-102 part numbers qualify for UL 1277 TC-ER-HL vs standard TC-ER?

Under UL 1277 and NEC hazardous-location rules, TC-ER-HL applies to cables up to 1.00 in. nominal O.D.: 1 Pair (37-102-610, 0.451 in.), 2 Pairs (37-102-611, 0.725 in.), 4 Pairs (37-102-613, 0.770 in.), 1 Triad (37-102-668, 0.470 in.) and 4 Triads (37-102-698, 0.960 in.). The 8-, 12- and 24-pair and 8- and 12-triad sizes exceed 1.00 in. O.D. and carry UL 1277 TC-ER plus MSHA ratings.

How does the shielding architecture differ between single-pair/triad and multi-pair/triad 37-102 cables?

Single-pair (37-102-610) and single-triad (37-102-668) cables use a 100% coverage aluminium/Mylar tape shield, tinned copper drain wire and an overall tinned copper braid. Multi-pair (2 to 24 pairs) and multi-triad (4 to 12 triads) cables add an individual 100% aluminium/Mylar shield and tinned copper drain wire on every pair or triad in addition to the overall foil, drain wire and tinned copper braid.

What electrical parameters govern loop length calculations on 37-102 16 AWG instrumentation cables?

At 20 °C, each 16 AWG (1.32 mm², 19x0.0117 in.) tinned copper conductor has a maximum DC resistance of 4.52 Ω/1000 ft (14.8 Ω/km), a nominal mutual capacitance of 32 nF/1000 ft (105 nF/km), a nominal inductance of 0.20 mH/1000 ft (0.66 mH/km) and an L/R ratio of 22.1 μH/Ω.

Specifications

37-102 Pairs & Triads Schedules & Technical Specifications

37-102 Key Specifications

  • Pair & triad range: 1, 2, 4, 8, 12, 24 pairs (37-102-610 to -699) & 1, 4, 8, 12 triads (37-102-668 to -734)
  • Conductors & electricals: 16 AWG (1.32 mm², 19x0.0117 in.) tinned Cu; 4.52 Ω/1000 ft DC resistance; 32 nF/1000 ft capacitance
  • Triple EMI shielding: 100% Al/polyester pair/triad shield + overall Al/polyester tape + tinned copper braid + drain wires
  • Crush & impact barrier: Polymeric crush/impact barrier passing UL 2225 MC-HL crush & impact tests without metal armor
  • Ratings & temperature: 0.6/1 kV, UL 1277 TC-ER-HL (up to 1 in. O.D.) / TC-ER, CSA CIC/TC, MSHA, -55 °C to +110 °C
37-102 Crush- & Impact-Resistant Shielded Mining Instrumentation Cable (0.6/1 kV TC-ER-HL, 1–24 Pairs & 1–12 Triads) technical data
ParameterValue
Part number rangePairs: 37-102-610 to 37-102-699 (1–24P); Triads: 37-102-668 to 37-102-734 (1–12T)
Conductor & electrical data16 AWG (1.32 mm², 19x0.0117 in.); 4.52 Ω/1000 ft at 20 °C; 32 nF/1000 ft mutual capacitance; 0.20 mH/1000 ft inductance
Voltage & temperature rating600 V (UL/CSA) and 0.6/1 kV (IEC); -55 °C cold bend, -40 °C cold impact, +110 °C continuous rating
Crush, impact & bend radiusMeets UL 2225 MC-HL crush and impact requirements; minimum bending radius 6 x cable O.D.
Approvals & flame testsUL 1277 TC-ER-HL (up to 1.0 in. O.D.) / TC-ER, CSA C22.2 No. 230/239 CIC/TC FT4, IEEE 1202, IEC 60332-3-22, MSHA
Commercial supply termsMinimum order quantity 50 m; manufacturing lead time 7 to 45 working days; final values confirmed on the quotation drawing
Selection boundary vs TC-ER Power and BS 5308Choose 37-102 for 16 AWG individually and overall braid-shielded pairs/triads with UL 2225 crush/impact protection and MSHA/TC-ER-HL ratings; choose Crush-Resistant TC-ER Power Cable for 14 AWG to 4/0 AWG power/control cores, or BS 5308 Part 1 for European 300/500 V fixed plant instrumentation.

37-102 Shielded Pairs Schedule (1 to 24 Pairs, 16 AWG)

37-102 Shielded Pairs Mining Instrumentation Cable (16 AWG / 1.32 mm², 0.6/1 kV) — Part Numbers & Dimensions
Part No.No. of PairsConductor Size & StrandingNominal O.D.Approx. WeightTray & Mine RatingNext step
37-102-6101 Pair16 AWG (1.32 mm², 19x0.0117 in. tinned Cu)0.451 in. (11.5 mm)106 lbs/1000 ft (158 kg/km)UL 1277 TC-ER-HL & MSHARequest this size
37-102-6112 Pairs16 AWG (1.32 mm², 19x0.0117 in. tinned Cu)0.725 in. (18.4 mm)279 lbs/1000 ft (415 kg/km)UL 1277 TC-ER-HL & MSHARequest this size
37-102-6134 Pairs16 AWG (1.32 mm², 19x0.0117 in. tinned Cu)0.770 in. (19.6 mm)340 lbs/1000 ft (506 kg/km)UL 1277 TC-ER-HL & MSHARequest this size
37-102-6168 Pairs16 AWG (1.32 mm², 19x0.0117 in. tinned Cu)1.075 in. (27.3 mm)702 lbs/1000 ft (1045 kg/km)UL 1277 TC-ER & MSHARequest this size
37-102-61812 Pairs16 AWG (1.32 mm², 19x0.0117 in. tinned Cu)1.235 in. (31.4 mm)1062 lbs/1000 ft (1580 kg/km)UL 1277 TC-ER & MSHARequest this size
37-102-69924 Pairs16 AWG (1.32 mm², 19x0.0117 in. tinned Cu)1.650 in. (41.9 mm)1560 lbs/1000 ft (2321 kg/km)UL 1277 TC-ER & MSHARequest this size

37-102 Shielded Triads Schedule (1 to 12 Triads, 16 AWG)

37-102 Shielded Triads Mining Instrumentation Cable (16 AWG / 1.32 mm², 0.6/1 kV) — Part Numbers & Dimensions
Part No.No. of TriadsConductor Size & StrandingNominal O.D.Approx. WeightTray & Mine RatingNext step
37-102-6681 Triad16 AWG (1.32 mm², 19x0.0117 in. tinned Cu)0.470 in. (11.9 mm)128 lbs/1000 ft (190 kg/km)UL 1277 TC-ER-HL & MSHARequest this size
37-102-6984 Triads16 AWG (1.32 mm², 19x0.0117 in. tinned Cu)0.960 in. (24.4 mm)453 lbs/1000 ft (674 kg/km)UL 1277 TC-ER-HL & MSHARequest this size
37-102-6778 Triads16 AWG (1.32 mm², 19x0.0117 in. tinned Cu)1.200 in. (30.5 mm)825 lbs/1000 ft (1228 kg/km)UL 1277 TC-ER & MSHARequest this size
37-102-73412 Triads16 AWG (1.32 mm², 19x0.0117 in. tinned Cu)1.395 in. (35.4 mm)1235 lbs/1000 ft (1838 kg/km)UL 1277 TC-ER & MSHARequest this size

In the 37-102 series, 1-pair (37-102-610, 0.451 in. O.D.), 2-pair (37-102-611, 0.725 in. O.D.), 4-pair (37-102-613, 0.770 in. O.D.), 1-triad (37-102-668, 0.470 in. O.D.) and 4-triad (37-102-698, 0.960 in. O.D.) have nominal diameters below 1.00 in. and carry the UL 1277 TC-ER-HL hazardous-location rating; larger 8-, 12- and 24-pair and 8- and 12-triad sizes carry UL 1277 TC-ER and MSHA ratings.

MSHA 30 CFR Part 7, UL 1277 TC-ER-HL, ICEA S-75-381 / NEMA WC 58 and CSA C22.2 No. 230 / No. 239 are cited as governing design and test references; TEBAOFLEX manufactures to the referenced construction parameters and confirms project-specific marking and test documentation on the quotation drawing.

ASCII part references for BOM and ERP entry: 37-102-610, 37-102-611, 37-102-613, 37-102-616, 37-102-618, 37-102-699, 37-102-668, 37-102-698, 37-102-677, 37-102-734.

Standards

37-102 Standards & Test References (UL 1277 TC-ER-HL, UL 2225, MSHA)

37-102 Crush- & Impact-Resistant Shielded Mining Instrumentation Cable (0.6/1 kV TC-ER-HL, 1–24 Pairs & 1–12 Triads) standards and test references
Standard or specificationApplication
UL 1277 & UL 2225 (MC-HL Crush/Impact)Tray cable exposed-run (TC-ER / TC-ER-HL) qualification and metallic-clad hazardous-location mechanical crush and impact resistance.
CSA C22.2 No. 230 & No. 239 (CIC/TC FT4)Canadian Control and Instrumentation Cable (CIC) and Tray Cable (TC) standards with FT4 / IEEE 1202 vertical tray flame compliance.
MSHA 30 CFR Part 7 & IEC 60332-3-22Mine Safety and Health Administration flame resistance and IEC Category A bunched vertical flame propagation compliance.
NEC Articles 336, 501, 502 & 725Permitted for cable tray, exposed run (ER) drop to utilization equipment, Class I/II Division 1 & 2 (where TC-ER-HL rated) and Class 1 instrumentation circuits.

Certifications and document support

TEBAOFLEX company certificates and quality system documentation

UL 1277 and UL 2225 tray and hazardous-location cable certification reference

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.