Submersible Pump Cables TEBAOFLEX

(N)TS-TGSH 3.6/6 kV Medium Voltage Hot Water Pump Cable

(N)TS-TGSH is a 3.6/6 kV halogen-free hot-water pump cable with SIR insulation, inner semiconductive field control and an EVA outer sheath.

  • Class 5 finely stranded tinned copper
  • 130 °C maximum conductor temperature
  • 11 kV / 5 minutes main-core AC test
  • Separate fixed and flexible bend requirements

Send the motor voltage, core configuration, installed length, pump-entry drawing and water conditions for a technical quotation.

Product information
Brand
TEBAOFLEX
Product overview

(N)TS-TGSH for Medium-Voltage Hot-Water Pump Connections

(N)TS-TGSH is a 3.6/6 kV round, halogen-free cable for hot-water pump connections and immersed electrical equipment under medium mechanical stress. Its construction combines Class 5 tinned copper conductors, an inner semiconductive rubber field-control layer, SIR silicone rubber insulation and an EVA outer sheath. An EPDM inner sheath is used where included in the selected construction.

The medium-voltage connection needs coordinated electrical and mechanical preparation. Match the motor circuit and termination to the actual core arrangement, insulation system and inner field-control layer. Include the pump-entry drawing, available sealing length and termination space when specifying a replacement cable.

Plan the route around the selected finished diameter. Fixed supported sections and flexible sections have separate bend requirements, so allow adequate space at wellheads, glands and changes of direction. Provide independent cable supports and use the pump’s designated lifting equipment. Select the required protective conductor from the motor connection drawing.

The conductor-temperature limit applies to the current-carrying conductor. State the actual water composition, treatment chemicals, immersion conditions and installed length for the project assessment. Immersion depth and the permitted water-temperature limit are confirmed for the specified project. Use this construction in non-hazardous locations.

For (N)TS-TGSH selection, explore the submersible pump cable range; for (N)TS-TGSH insulation selection, read the high-temperature wire insulation guide.

Construction

Construction

Select the core count, protective-conductor arrangement and inner-sheath construction for the pump connection. The inner semiconductive rubber layer provides electrical field control.

(N)TS-TGSH four-core cross-section with inner semiconductive field control, SIR insulation and EVA sheath
Representative (N)TS-TGSH four-core G arrangement with inner field control on the power cores and an EPDM inner sheath.
(N)TS-TGSH medium-voltage construction
ElementConstruction
ConductorClass 5 finely stranded tinned copper.
Electrical field controlInner layer of semiconductive rubber compound on the power conductors.
Core insulationSIR silicone rubber.
Core identificationNumbering; G configurations include a green/yellow protective conductor.
Inner sheathEPDM rubber where included in the selected construction.
Outer sheathEVA rubber compound.
Metallic screenUnscreened family construction.
ShapeRound.
Applications

Applications

Medium-voltage power connections to hot-water pumps and immersed equipment in industrial, agricultural, indoor and outdoor supported installations under medium mechanical stress.

(N)TS-TGSH medium-voltage hot-water pump cable on a supported industrial route
Application illustration: a supported medium-voltage cable route to a hot-water pump connection.
(N)TS-TGSH installation selection
Selection pointRequirement
Voltage and terminationCoordinate the 3.6/6 kV motor circuit, inner field-control layer and termination preparation with the equipment drawing.
Entry fitSpecify the finished diameter, seal range, strain relief and space for the termination.
Bending and supportReserve 6 × maximum diameter for fixed routes and 10 × maximum diameter for flexible sections. Support the cable independently from the pump lifting system.
Conductor and water temperaturesUse the conductor-temperature limit for the electrical loading assessment; confirm the project’s water conditions separately.
Water chemistryState water composition and treatment chemicals for material selection.
Location restrictionNot for explosion-hazardous areas.
Specifications

Specifications

Medium-voltage hot-water pump cable selection summary
ParameterValue
Rated voltage U₀/U3.6/6 kV
ConductorClass 5 flexible tinned copper
Core insulationSIR silicone rubber
Electrical field controlInner semiconductive rubber layer
Outer sheathEVA

Keep the operating-voltage limits, main-core test and installation conditions together when selecting the medium-voltage pump connection.

(N)TS-TGSH 3.6/6 kV technical profile
ParameterValue or condition
Rated voltage U₀/U3.6/6 kV
Maximum AC operating voltage4.2/7.2 kV
Maximum DC operating voltage5.4/10.8 kV
AC test voltage — main cores11 kV / 5 minutes
Maximum conductor temperature130 °C
Short-circuit conductor temperature / duration350 °C / maximum 5 s
Minimum ambient temperature, fixed−50 °C
Minimum ambient temperature, flexible−25 °C
Maximum conductor tensile stress15 N/mm²
Minimum bend radius, fixed6 × maximum overall diameter
Minimum bend radius, flexible10 × maximum overall diameter
Family range1–4 cores; cross-sections up to 70 mm². Select core count and cross-section together.
ConductorClass 5 flexible tinned copper
Core insulationSIR silicone rubber
Electrical field controlInner semiconductive rubber layer
Outer sheathEVA
Metallic screenUnscreened
Location restrictionNot for explosion-hazardous areas.
Standards

Standards

(N)TS-TGSH construction and test references
ReferenceApplication
EN 50525-2-21Construction reference: based on EN 50525-2-21.
DIN EN 60228Class 5 conductor reference.
DIN EN 50525-2-21Water-resistance reference.
DIN VDE 0298-3General cable-use and installation guidance.
Main-core AC cable test11 kV for 5 minutes.

For conductor classes, see the IEC 60228 standard scope.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.