OnGcekż-G2 0.6/1 kV Single-Sheath Longwall & Heading Mining Trailing Cable
OnGcekż-G2 (OnGcekz-G2) is a 0.6/1 kV screened flexible mining trailing cable built to the WT-96/K-346 construction, with six EPR-insulated tinned copper power cores, each under a semi-conducting tape and 75% tinned copper/fibre braid, laid up around a central insulated and screened pilot group with a 25 mm² earth conductor under a single extra-heavy-duty ON-4 polychloroprene sheath.
Longwall face equipment, roadheaders and heading machines in Polish-standard and Central European coal mines draw heavy currents through a single trailing cable that is dragged, twisted and crushed every shift. OnGcekż-G2, also written OnGcekz-G2, answers this duty at 0.6/1 kV by splitting each phase over two power cores: six flexible tinned copper conductors with EPR insulation are laid up around a central group of insulated and screened pilot cores, with a 25 mm² tinned copper earth conductor.
Every power core carries a semi-conducting tape and a composite tinned copper/fibre braid with 75% coverage, so a damaged core faults to the screen and the earth-leakage protection trips quickly. The cable is finished with one extra-heavy-duty ON-4 polychloroprene sheath, 5.0 mm thick, that resists impact, abrasion, tearing, oil and water and is flame retardant. The reference schedule covers 6×35, 6×50, 6×70 and 6×95 mm² layouts and three dual-circuit layouts, 3×70+3×16, 3×70+3×25 and 3×70+3×35 mm², whose current ratings are stated per circuit, for example 190+117 A.
OnGcekż-G2 is the single-sheath version. Choose O2nGcekż-G2 when the route needs a double sheath with an open polyamide braid, OnGcekż-G for three-power-core trailing cable, and 1-CBEH where a gassy-mine cable with dedicated control and monitoring cores is specified. Approval documents for the destination mine are confirmed per order.
Explore the mining and tunneling cable range for related configurations.
OnGcekż-G2 (OnGcekz-G2) 0.6/1 kV Cable Construction & Layer Structure
The representative horizontal sample shows OnGcekż-G2 6x50+25+6x2.5 mm²: six tinned copper power cores with EPR insulation, semi-conducting tape and tinned copper/fibre braid screens, laid up around a central group of six screened 2.5 mm² pilot cores with a 25 mm² earth conductor under one black ON-4 polychloroprene sheath.

| Component | Material and construction |
|---|---|
| Power Conductors | Six flexible tinned copper conductors to PN-EN 60228 (IEC 60228) Class 5, 35 mm² to 95 mm², or a dual-circuit 3x70 mm² plus 3x16, 3x25 or 3x35 mm² layout. |
| EPR Insulation | Ethylene-propylene rubber type IEP to PN-89/E-29100, 2.0 mm, over a polyester separator tape. |
| Power Core Screen | Semi-conducting tape plus composite tinned copper/fibre braid with 75% coverage on each power core. |
| Pilot Group and Earth | Insulated and screened annealed tinned copper pilot cores (6x2.5, 7x4 or 1x4 mm²) at the centre, with a 25 mm² flexible tinned copper earth conductor. |
| Single ON-4 Sheath | One extra-heavy-duty polychloroprene sheath type ON-4 to PN-89/E-29100, 5.0 mm, black, oil resistant and flame retardant. |
OnGcekż-G2 Type Designation Breakdown
- O: flexible rubber-sheathed (oponowy) cable
- n: oil-resistant, flame-retardant polychloroprene sheath
- G: mining (górniczy) duty
- e: screened power cores (semi-conducting tape and tinned copper/fibre braid)
- k: pilot (control) cores in the cable
- ż: protective earth conductor
OnGcekż-G2 0.6/1 kV Mining Applications & Duty Scope
Specify OnGcekż-G2 where a 0.6/1 kV machine needs high current through split power cores and a single heavy sheath is sufficient.

- Longwall shearers, face conveyors and stage loaders fed at 0.6/1 kV through heavily stressed trailing cable.
- Roadheaders and heading machines in coal and salt mines where the cable is dragged along the floor and around props.
- Machines with two separately protected circuits, using the dual-circuit 3x70 mm² plus 16, 25 or 35 mm² layouts.
- Mobile mining and industrial machines in methane and coal-dust hazard areas, subject to the approval documents required by the mine.
OnGcekż-G2 vs O2nGcekż-G2, OnGcekż-G and 1-CBEH Selection Boundary
| Model | Power cores | Sheath | Best fit |
|---|---|---|---|
| OnGcekż-G2 (this page) | Six (or 3+3 dual circuit) | Single ON-4 polychloroprene | High-current 0.6/1 kV face and heading machines |
| O2nGcekż-G2 | Six (or 3+3 dual circuit) | Double layer with open polyamide braid | Same layouts where extra tear and pull resistance is needed |
| OnGcekż-G | Three | Polychloroprene | Standard three-core screened trailing duty |
| 1-CBEH | Three plus control and monitoring cores | Heavy-duty elastomer | Gassy-mine machines needing control and monitoring cores |
Single-sheath and double-sheath versions share the same core layouts but are not interchangeable without checking gland diameter and handling duty.
Related selection resources
- Mining and tunneling cable engineering solutions
- Underground vs surface mining cables: longwall, hard-rock heading and open-pit selection guide
- O2nGcekż-G2 0.6/1 kV Double-Sheath Mining Cable
- OnGcekż-G 0.6/1 and 3.6/6 kV Screened Mining Cable
- 1-CBEH 0.6/1 kV Gassy Mine Cable with Control and Monitoring Cores
OnGcekż-G2 (OnGcekz-G2) Frequently Asked Questions
What is the difference between OnGcekż-G2 and O2nGcekż-G2?
Both have six screened EPR power cores around a screened pilot group. OnGcekż-G2 has one ON-4 polychloroprene sheath; O2nGcekż-G2 has a double-layer jacket with an open polyamide braid between the layers.
Why does the cable have six power cores?
Each phase is split over two cores, which keeps the cable flexible while carrying high current. The dual-circuit layouts instead feed a main 3x70 mm² circuit and a smaller auxiliary circuit.
How is OnGcekz-G2 written without Polish characters?
OnGcekz-G2. Both spellings refer to the same 0.6/1 kV construction to WT-96/K-346.
What are the MOQ and lead time?
The minimum order quantity is 50 m and the manufacturing lead time is 7 to 45 working days, depending on layout and quantity.
OnGcekż-G2 Dimensions, Ampacity & Technical Specifications
OnGcekż-G2 Key Specifications
- Voltage: 0.6/1 kV
- Layouts: 6x35 to 6x95 mm² plus dual-circuit 3x70+3x16 to 3x70+3x35 mm²
- Screen: Semi-conducting tape and 75% tinned copper/fibre braid on each power core
- Sheath: Single ON-4 polychloroprene layer, 5.0 mm
- Supply: MOQ 50 m; 7 to 45 working days
| Parameter | Value |
|---|---|
| Construction reference | WT-96/K-346; conductors to PN-EN 60228 (IEC 60228) Class 5; EPR and ON-4 compounds to PN-89/E-29100 |
| Rated voltage | 0.6/1 kV |
| Core arrangement | Six power cores (or 3+3 dual circuit) around a screened pilot group, with a 25 mm² earth conductor |
| Conductor temperature | 90 °C maximum; ambient -35 °C to +55 °C |
| Minimum bending radius | 8 x overall diameter |
| Commercial supply terms | Minimum order quantity 50 m; manufacturing lead time 7 to 45 working days; final values confirmed on the quotation drawing |
| Selection boundary vs O2nGcekż-G2, OnGcekż-G and 1-CBEH | Choose OnGcekż-G2 for six split power cores under one ON-4 sheath; choose O2nGcekż-G2 for a double sheath with polyamide braid, OnGcekż-G for three power cores and 1-CBEH for gassy-mine control and monitoring cores. |
OnGcekż-G2 0.6/1 kV Reference Schedule
| Size (mm²) | Power Core Insulation (mm) | Outer Jacket (mm) | Max. O.D. or Min./Approx./Max. O.D. (mm) | Approx. Weight (kg/km) | Ampacity at 25 °C (A) | Max. Recommended Tension (N) | Next step |
|---|---|---|---|---|---|---|---|
| OnGcekż-G2 6x35+25+6x2.5 | 2.0 | 5.0 | 65.0 | 5250 | 150 | 3150 | Request this size |
| OnGcekż-G2 6x50+25+6x2.5 | 2.0 | 5.0 | 65.0 | 6100 | 188 | 4500 | Request this size |
| OnGcekż-G2 6x70+25+6x2.5 | 2.0 | 5.0 | 65.0 | 8070 | 230 | 6300 | Request this size |
| OnGcekż-G2 6x95+25+7x4 | 2.0 | 5.0 | 75.0 | 9300 | 276 | 8550 | Request this size |
| OnGcekż-G2 3x70+3x16+25+4 | 2.0 | 5.0 | 57.0/60.1/63.0 | 6470 | 190+117 | 3870 | Request this size |
| OnGcekż-G2 3x70+3x25+25+4 | 2.0 | 5.0 | 57.0/60.1/64.0 | 6875 | 190+149 | 4275 | Request this size |
| OnGcekż-G2 3x70+3x35+25+4 | 2.0 | 5.0 | 57.0/60.1/64.0 | 7015 | 190+180 | 4725 | Request this size |
OnGcekż-G2 Construction and Rating Parameters
| Parameter | Value |
|---|---|
| Rated voltage U0/U | 0.6/1 kV |
| Construction reference | WT-96/K-346 |
| Power conductors | Flexible tinned copper, PN-EN 60228 (IEC 60228) Class 5 |
| Insulation | Ethylene-propylene rubber (EPR) type IEP to PN-89/E-29100, 2.0 mm |
| Power core screen | Semi-conducting tape plus composite tinned copper/fibre braid, 75% coverage |
| Earth conductor | Flexible tinned copper, 25 mm² |
| Pilot cores | Annealed tinned copper in a group, insulated and screened, at the centre of the lay-up |
| Core identification | Power cores two red, two green, two natural (black, grey, brown on request) |
| Outer sheath | Single layer extra-heavy-duty polychloroprene type ON-4 to PN-89/E-29100, 5.0 mm, black |
| Temperatures | Ambient -35 °C to +55 °C; maximum conductor temperature 90 °C |
| Minimum bending radius | 8 x overall diameter |
Dual-circuit ampacities such as 190+117 A give the main 3x70 mm² circuit and the auxiliary 3x16, 3x25 or 3x35 mm² circuit separately; three-value diameters are minimum/approximate/maximum.
Polish designations and the ZN / WT works standards are cited as construction references; TEBAOFLEX builds to the referenced construction and does not claim a Polish mining admission or third-party approval for it, so state the approval documents your mine requires when requesting a quotation.
ASCII part references for BOM and ERP entry: OnGcekz-G2 6x35+25+6x2.5, OnGcekz-G2 6x50+25+6x2.5, OnGcekz-G2 6x70+25+6x2.5, OnGcekz-G2 6x95+25+7x4, OnGcekz-G2 3x70+3x16+25+4, OnGcekz-G2 3x70+3x25+25+4, OnGcekz-G2 3x70+3x35+25+4.
OnGcekż-G2 Standards & Test References (WT-96/K-346)
| Standard or specification | Application |
|---|---|
| WT-96/K-346 | Works construction reference for OnGcekż-G2 and O2nGcekż-G2 0.6/1 kV mining trailing cables. |
| PN-EN 60228 / IEC 60228 | Conductors of insulated cables: Class 5 flexible tinned copper conductors and maximum DC resistance. |
| PN-89/E-29100 | Polish compound specification for EPR insulation type IEP and polychloroprene sheath type ON-4. |
| IEC 60332-1-2 | Vertical flame propagation test for a single insulated wire or cable, the flame reference for the sheath. |
Certifications and document support
TEBAOFLEX company certificates and quality system documentation
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
O2nGcekż-G2 0.6/1 kV Double-Sheath Mining Cable
A related cable option for a different application or duty profile.
View productOnGcekż-G 0.6/1 & 3.6/6 kV Screened Mining Cable
A related cable option for a different application or duty profile.
View product1-CBEH 0.6/1kV Gassy Mine Cable with Control and Monitoring Cores
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.