SAE J2031 Class E 7 mm Copper-Core EPDM/Silicone Ignition Cable (180 °C)
Engineered to SAE J2031 Type 1 Class E and ISO 3808 Class E performance criteria, TEBAOFLEX 7.0 mm (plus 5.0 mm and 8.0 mm) copper-core high-voltage ignition cable combines a zero-suppression 16 AWG (19/29) tin-plated copper conductor, a high-dielectric EPDM inner insulator, a reinforcing yarn braid for terminal crimp retention and a +180 °C (356 °F) silicone rubber outer jacket rated to 35 kV dielectric breakdown.
TEBAOFLEX SAE J2031 Type 1 Class E 7.0 mm copper-core ignition cable (alongside compact 5.0 mm 18 AWG and heavy-wall 8.0 mm 14 AWG industrial options) delivers 35,000 V dielectric breakdown strength and zero resistive attenuation (~13.7 to 14.5 Ohm/km DC resistance on 16 AWG / 1.5 mm²) across -40 °C to +180 °C (356 °F) stationary engine and combustion environments.
Automotive carbon-impregnated fibreglass or spiral-wound resistive spark-plug wires rapidly carbon-track and open-circuit under 8,000-hour/year continuous firing on natural-gas CHP cogeneration gensets, landfill-gas engines, industrial boilers and marine auxiliary engines, while plain silicone-only walls lack crimp pull-out strength. Pairing an inner corona-blocking EPDM dielectric with an open-weave reinforcing yarn braid and a vulcanized +180 °C silicone outer jacket maximizes voltage withstand, waterproof RTV boot sealing and mechanical terminal retention.
Specify SAE J2031 Class E 7.0 mm tinned-copper EPDM/silicone cable whenever industrial gas engines, marine engines (not requiring internal wire RFI suppression, or using external resistor caps/plugs), oilfield flare igniters or furnace burners need 7 mm standard ignition gland/boot fitment; choose all-silicone halogen-free FZLSi 10/12 kV where IEC 60754 zero-halogen boiler compliance is mandatory (bulk reels only, MOQ 50 m, 7 to 45 working days).
Explore the high-temperature wire and cable range for related configurations.
SAE J2031 Class E 7 mm EPDM + Braid + Silicone Construction
Each 7.0 mm (and companion 5.0 mm / 8.0 mm) bulk ignition cable uses a dual-elastomer reinforced composite wall engineered for 35 kV dielectric margin and high pull-off force on crimped or screw-thorn ignition terminals.

| Component | Material and construction |
|---|---|
| 1. Tin-Plated Copper Stranded Conductor (Zero RFI Suppression) | 16 AWG (19/29 AWG, ~1.31 mm²) or metric 1.5 mm² (30/0.25 mm) annealed tinned copper strands per ASTM B33 / IEC 60228 for easy soldering, fold-back crimping or axial screw-pin contact. |
| 2. High-Dielectric EPDM Inner Insulator | Extruded electrical-grade ethylene-propylene-diene elastomer (EPDM) providing superior kV/mm impulse dielectric strength (35 kV assembly breakdown) and internal corona resistance. |
| 3. High-Tenacity Reinforcing Braid | Intermediate synthetic/glass reinforcing yarn braid uniting the inner EPDM core and outer jacket so brass or stainless snap-lock terminals grip without tearing through soft elastomer. |
| 4. +180 °C (356 °F) Silicone Rubber Outer Jacket | Smooth black or red heat-resistant silicone rubber outer sheath resisting engine oil splash, ozone, salt fog and +180 °C radiant heat while sealing watertight with silicone boots and RTV. |
SAE J2031 Type 1 Class E Specification Breakdown
- SAE J2031 / ISO 3808: High-tension ignition cable performance standards governing dielectric withstand, thermal aging and fluid resistance
- Type 1 (Metallic): Low-resistance stranded metallic tinned copper conductor (zero internal resistive carbon suppression)
- Class E (180 °C): +180 °C (356 °F) continuous heat-resistance class achieved via vulcanized silicone rubber outer jacketing
- EPDM Inner Core: High-impulse-strength ethylene-propylene-diene dielectric core delivering 35 kV breakdown on 7.0 mm OD
- Reinforcing Braid: Embedded high-tenacity yarn braid preventing snap-lock crimp terminal pull-out under engine vibration
SAE J2031 7 mm Gas Engine, CHP Genset & Burner Applications
Deploy TEBAOFLEX bulk SAE J2031 Class E 7 mm copper-core ignition cable on continuous-duty industrial engines, combustion turbines, marine powerplants and commercial heating systems.

- Stationary natural-gas, biogas, coal-seam-gas and landfill-gas CHP cogeneration engines using external resistor spark plugs or shielded industrial ignition rails.
- Industrial gas/oil boiler burners, hot-air generators, asphalt-plant aggregate dryers, incinerator pilots and petrochemical flare exciters.
- Inboard marine engines, auxiliary pump drives, agricultural irrigation engines and vintage/industrial magneto ignition systems not requiring resistive cable suppression.
- OEM ignition harness assemblers cutting custom lead lengths from 50 m, 100 m or 300 m bulk reels for crimp-terminal or European screw-on suppressor connector assembly.
SAE J2031 7 mm Copper vs FZLSi 10/12 kV vs Style 3257
| Ignition Cable Type | Core & Insulation System | Dielectric / Temp Envelope | When to Specify |
|---|---|---|---|
| SAE J2031 Class E 7 mm (this page) | 16 AWG tinned Cu + EPDM + braid + silicone | 35 kV breakdown, -40 to +180 °C | Industrial gas gensets (CHP), marine engines & burners needing 7 mm boot seal & high crimp pull-out |
| FZLSi 10 kV & 12 kV Cable | 1.0–2.5 mm² tinned Cu + silicone + glass braid + silicone | 10/12 kV (20 kV AC test), -50 to +180 °C | European boiler, kiln & HVAC burners requiring IEC 60754 zero-halogen all-silicone construction |
| UL 3257 / 25 kV Igniter Wire | Tinned/nickel Cu + heavy-wall 250 °C silicone | 10 kV AC / 25 kV DC, +250 °C | High-ambient (>180 °C up to 250 °C) turbine, flare pilot & furnace igniters |
| Automotive Carbon / Spiral Core (Not Supplied) | Carbon-impregnated aramid or ferrite spiral | 3–10 kOhm/m resistive RFI core | Passenger-car street ignition sets — avoid on continuous-duty industrial burners & CHP gensets |
Specify SAE J2031 Class E 7 mm tinned-copper EPDM/silicone bulk cable for continuous-duty CHP gas engines, industrial burners and marine ignition harnesses.
SAE J2031 Class E Bulk Ignition Cable RFQ Checklist
- Outer diameter requirement: standard 7.0 mm (or 5.0 mm compact / 8.0 mm heavy-wall) to match your ignition boots, grommets and coil towers.
- Conductor gauge: 16 AWG (19/29) standard, metric 1.5 mm² (30/0.25) Class 5, or 14 AWG (19/27) on 8.0 mm heavy-wall builds.
- Outer silicone jacket colour (matte black or brick red) and optional unprinted vs custom metre-marked surface.
- Termination method on your assembly line (fold-back brass/stainless snap-lock crimp vs European M4 axial thorn screw-in connector).
- Total meterage and bulk reel size (MOQ 50 m; 50 m, 100 m or 300 m continuous reels, 7 to 45 working days lead time).
Related selection resources
- Full high-temperature and high-voltage ignition cable product range
- 7/10 kV all-silicone single-wall industrial burner ignition cable
- Style 3257 250 °C 10 kV AC / 25 kV DC high-temperature silicone ignition wire
- 25 kV flare-stack and petrochemical high-energy igniter cable
- Engineering guide: Why tinned copper prevents high-temperature conductor oxidation
SAE J2031 7 mm Copper-Core Ignition Cable FAQ
Does SAE J2031 Class E 7 mm copper ignition cable provide RFI or EMI suppression?
No. It uses a solid metallic 16 AWG (19/29) tin-plated copper conductor (~14.5 Ohm/km) with zero resistive suppression so maximum spark energy reaches industrial burner electrodes and gas-engine spark plugs without carbon-core degradation. Where EMI suppression is needed, fit external resistor plugs or 1–5 kOhm suppressor caps.
Why does SAE J2031 Class E 7 mm cable combine an inner EPDM insulator with an outer silicone jacket?
35,000 V breakdown strength plus +180 °C heat resistance. EPDM delivers high kV/mm dielectric puncture strength and mechanical rigidity for terminal crimping, while the outer +180 °C silicone jacket resists radiant exhaust heat, ozone and oil mist and bonds watertight with silicone boots.
Can SAE J2031 Class E 7 mm copper ignition cable be used with European screw-in suppressor caps?
Yes. Both the 16 AWG (19/29) and metric 1.5 mm² (30/0.25) tinned copper conductors accept axial threaded thorn pins on European screw-on suppressor connectors as well as stripped fold-over crimping and direct soldering.
Do you sell SAE J2031 7 mm cable as pre-terminated car spark plug sets or industrial bulk reels?
No retail car sets; TEBAOFLEX supplies un-terminated bulk SAE J2031 Class E ignition cable on 50 m, 100 m and 300 m reels (MOQ 50 m) for CHP genset packagers, industrial burner OEMs, marine engine builders and harness assembly shops.
Is SAE J2031 Class E copper ignition cable also available in 8.0 mm heavy-wall or 5.0 mm OD?
Yes. Alongside our flagship 7.0 mm 16 AWG construction, we extrude 5.0 mm 18 AWG (25 kV breakdown) for compact pilot tubes and 8.0 mm 14 AWG (40 kV breakdown) for long-run high-BMEP stationary natural-gas generator sets.
SAE J2031 Class E 7 mm, 5 mm & 8 mm Bulk Reel Schedule
SAE J2031 7 mm Key Dielectric, Conductor, Temp & Reel Summary
- Zero-resistance copper core: 16 AWG (19 strands of 29 AWG, ~1.31 mm², <= 14.5 Ohm/km) tin-plated copper delivers full spark energy with zero carbon-core burnout on continuous-duty industrial engines
- EPDM + braid + silicone hybrid wall: High-dielectric EPDM inner core (35,000 V breakdown) + reinforcing braid for positive crimp/screw terminal pull-off retention + +180 °C waterproof silicone outer jacket
- SAE J2031 Type 1 Class E thermal grade: Continuous -40 °C to +180 °C (356 °F) service temperature suitable for hot exhaust-manifold proximity on stationary CHP gensets and industrial burners
- Crimp & screw-in terminal ready: Cleanly strips over tinned copper strands for soldering, brass/stainless snap-lock crimping or European M4 threaded suppressor caps
- B2B bulk factory reels only: Supplied exclusively as bulk un-terminated cable on 50 m, 100 m or 300 m reels (MOQ 50 m, 7 to 45 working days; no retail automotive plug-wire sets)
| Parameter | Value |
|---|---|
| Rated voltage | 35000 V (35 kV) dielectric strength engineered to SAE J2031 Type 1 Class E and ISO 3808 Class E high-voltage ignition criteria |
| Conductor and stranding | 16 AWG (19 strands of 29 AWG tinned copper, approx. 1.31 mm2) on 7.0 mm standard build; 18 AWG on 5.0 mm and 14 AWG on 8.0 mm options |
| Composite insulation and jacket | High-dielectric EPDM inner insulator plus reinforcing terminal-retention braid plus +180 C (356 F) silicone rubber outer jacket |
| Service temperature and EMI note | -40 C to +180 C continuous service; metallic copper conductor provides zero internal RFI or EMI suppression (use resistor plugs/caps where required) |
| Bulk reel MOQ and lead time | MOQ 50 m supplied as continuous bulk cable on 50 m, 100 m or 300 m factory reels in 7 to 45 working days (un-terminated bulk cable) |
| Waterproofing and boot fitment | True 7.0 mm (+/- 0.20 mm) circular OD fits standard 7 mm silicone/EPDM boots, brass glands and European screw-in suppressor connectors |
| Strip and termination behaviour | Cleanly strips down to bright tin-plated copper strands for fold-over crimp ferrules, direct soldering or axial thorn-screw ignition caps |
SAE J2031 Class E 7 mm (plus 5 mm & 8 mm) Copper-Core Bulk Reel Schedule
| Model, OD & Conductor Size | Tinned Cu Stranding | Jacket Colour | Dielectric Breakdown | Max. DC Resistance at 20 °C (Ω/km) | Approx. Weight (kg/km) | Bulk Reel Put-Up | Next step |
|---|---|---|---|---|---|---|---|
| SAE J2031 Class E 7.0 mm 16 AWG Black | 19/29 AWG (~1.31 mm²) | Black | 35,000 V | 14.5 | 64 | 50 m / 100 m / 300 m | Request this size |
| SAE J2031 Class E 7.0 mm 16 AWG Red | 19/29 AWG (~1.31 mm²) | Brick Red | 35,000 V | 14.5 | 64 | 50 m / 100 m / 300 m | Request this size |
| SAE J2031 Class E 7.0 mm 1.5 mm² Black | 30/0.25 mm (Class 5) | Black | 35,000 V | 13.7 | 67 | 50 m / 100 m / 300 m | Request this size |
| SAE J2031 Class E 7.0 mm 1.5 mm² Red | 30/0.25 mm (Class 5) | Brick Red | 35,000 V | 13.7 | 67 | 50 m / 100 m / 300 m | Request this size |
| SAE J2031 Class E 5.0 mm 18 AWG Black | 16/30 AWG (~0.82 mm²) | Black | 25,000 V | 23.2 | 38 | 100 m / 300 m | Request this size |
| SAE J2031 Class E 8.0 mm 14 AWG Black | 19/27 AWG (~2.08 mm²) | Black | 40,000 V | 8.9 | 86 | 50 m / 100 m | Request this size |
| SAE J2031 Class E 8.0 mm 14 AWG Red | 19/27 AWG (~2.08 mm²) | Brick Red | 40,000 V | 8.9 | 86 | 50 m / 100 m | Request this size |
Constructed to SAE J2031 Type 1 Class E (metallic conductor, +180 °C / 356 °F temperature class) and ISO 3808 Class E unscreened high-voltage ignition cable dimensional and dielectric test methods; final tolerances are confirmed on the quotation drawing.
IMPORTANT EMI NOTICE: Metallic tin-plated copper conductor cable provides zero internal RFI/EMI resistive suppression; on ECU-controlled engines requiring electromagnetic interference damping, pair with 1 kOhm to 5 kOhm resistor spark plugs or threaded suppressor connectors.
TEBAOFLEX supplies this product strictly as un-terminated B2B bulk cable on factory reels (minimum order quantity 50 m, standard 100 m and 300 m reels; 7 to 45 working days lead time) — pre-cut retail passenger-car spark plug wire sets are not offered.
ASCII part references for BOM and ERP entry: TF-J2031E-7MM-16AWG-BK; TF-J2031E-7MM-16AWG-RD; TF-J2031E-7MM-1.5MM2-BK; TF-J2031E-7MM-1.5MM2-RD; TF-J2031E-5MM-18AWG-BK; TF-J2031E-8MM-14AWG-BK; TF-J2031E-8MM-14AWG-RD.
SAE J2031 Class E, ISO 3808 & ASTM B33 Reference Standards
| Standard or specification | Application |
|---|---|
| SAE J2031 Type 1 Class E Reference | High-tension ignition cable construction and thermal endurance reference for metallic-conductor (Type 1) +180 °C / 356 °F (Class E) reinforced elastomer leads. |
| ISO 3808 Class E Reference | International dimensional (5 mm, 7 mm, 8 mm nominal OD), high-voltage dielectric breakdown, saltwater immersion and thermal-shock reference for unscreened ignition cables. |
| ASTM B33 / IEC 60228 Tinned Copper | Tin-plated annealed copper strand coating and DC resistance standard ensuring corrosion-free crimp and solder joints. |
| UL 3257 / Industrial HV Dielectric Comparison | For +250 °C all-silicone appliance/burner leads without EPDM inner core, compare our Style 3257 (10 kV AC / 25 kV DC) or halogen-free FZLSi 10/12 kV cables. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and factory high-voltage dielectric testing
ASTM B33 — Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
7/10 kV Silicone Ignition Cable
A related cable option for a different application or duty profile.
View productUL 3257 Silicone Ignition Wire, 250°C 10kV AC / 25kV DC
A related cable option for a different application or duty profile.
View productFlare Stack Ignition & Igniter Cable 25 kV DC / 10 kV AC, 250°C
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.