Get a Quote
Oil and Gas Cables TEBAOFLEX

Type P Control Cable 600V / 0.6/1kV 18 AWG Armored and Sheathed

Type P Control Cable 600V / 0.6/1kV 18 AWG Armored and Sheathed: procurement-ready Type P construction and project-selection data. Confirm size, voltage, screening, armor, route and certification requirements at RFQ.

Product information
SKU
Type P Control Cable 600V / 0.6/1kV 18 AWG Armored and Sheathed
Brand
TEBAOFLEX
Product overview

Type P control cable 18 AWG is a Type P offshore cable selection for marine and drilling control circuits, with a 600 V or 0.6/1 kV rating and a multi-conductor, armored and sheathed construction. The current reference configuration uses soft annealed stranded tinned copper, chemically cross-linked polyolefin (XLPO) insulation, a flame-retardant thermosetting CPE jacket and braided bronze armor. Its 125°C continuous conductor temperature, oil/abrasion/moisture/sunlight resistance and cold-bend reference to -40°C support engineering review for harsh routes.

Use this page when the cable schedule calls for Type P control, auxiliary, signal or low-power instrumentation wiring with mechanical protection. Confirm the number of cores, conductor class, screen or drain-wire arrangement, armor bonding, gland system, minimum bend radius and final ampacity before release. The 18 AWG listing is a reference configuration; project-specific core counts and jacket options are quoted to order. Use the approved cable schedule to verify each termination and route.

For procurement, send voltage, core count, route, temperature, hazardous-area classification, fire test, mud/oil exposure and required certificates. Compare the Oil & Gas Cables range, the Type P 1C power cable and the Type P VFD cable before submitting an RFQ.

Construction

Construction

The reference build is a flexible multi-conductor Type P cable with mechanical protection. Final core count, colour code, armour coverage and sheath compound follow the approved project datasheet.

ElementReference constructionBuyer check
ConductorSoft annealed stranded tinned copper; high-strand-count flexibility is available by design.Confirm conductor class, stranding and core identification.
InsulationChemically cross-linked polyolefin (XLPO), Type P marine/offshore insulation system.Confirm voltage level and insulation thickness.
JacketFlame-retardant thermosetting CPE; project jacket options are reviewed at RFQ.State oil, mud, sunlight and temperature exposure.
Armor / sheathBraided bronze armor with an outer sheath for the armored and sheathed configuration.Confirm braid material, bonding and gland compatibility.
Applications

Applications

  • Control and auxiliary circuits on offshore platforms, MODUs, drilling rigs and marine vessels.
  • Fixed equipment, module and cable-tray routes in oil and gas facilities.
  • Signal or low-power instrumentation circuits where the approved schedule calls for Type P control cable.
  • Routes exposed to oil, abrasion, moisture, vibration or sunlight when the selected jacket evidence covers the exposure.

Installation boundary: armored Type P cable is not automatically a fire-resistant, mud-resistant or hazardous-area approval. Confirm the required classification, fire-integrity test, bonding method and installation standard in the RFQ.

Specifications

Specifications

ItemReference valueRFQ confirmation
Voltage600 V or 0.6/1 kVState U0/U, test voltage and system frequency.
Conductor size18 AWG multi-conductor referenceConfirm core count and allowable size range.
Temperature125°C continuous conductor referenceCheck ampacity derating and ambient temperature.
Cold performance-40°C cold bend and -35°C cold impact referencesConfirm the required project test scope.
Electrical dataResistance, capacitance, inductance, OD, weight and ampacity vary by core count.Request the approved size datasheet.
Standards

Standards

Use the standards named in the approved purchase specification and request model-specific evidence. The current Type P reference data identifies the following design and test references:

  • IEEE 1580 and IEEE 45 marine shipboard cable references.
  • UL 1309 marine shipboard cable reference and applicable CSA marine cable references.
  • IEEE 1202 and IEC 60332-3-22 Category A flame-propagation references where required.
  • IEC 60092 and ASTM B33 references may be specified for international marine projects.

Standards listed here are selection references, not a blanket approval claim. List the required certificate, classification society, fire test, hazardous-area and inspection documents in the RFQ.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.