High Temperature Cables TEBAOFLEX

UL 10086, UL 1516 & UL 1523 Extruded ETFE Hook-Up Wire (150–200 °C, 300/600 V)

UL 10086, UL 1644, UL 1516, UL 1523 and UL 1422 extruded ETFE hook-up wires (150 V to 600 V AC, -70 °C to +150/+200 °C) combine tinned, silver-plated or nickel-plated copper conductors (30 AWG to 10 AWG) with high-modulus ethylene-tetrafluoroethylene fluoropolymer insulation for cut-through, radiation and chemical resistance.

Product information
SKU
TF-ETFE-UL10086-1516
Brand
TEBAOFLEX
Product overview

UL 10086, UL 1644, UL 1516, UL 1523 and UL 1422 extruded ETFE single-core equipment wires fill the mechanical-toughness gap between standard PVC/XLPE cabinet wire and softer perfluoropolymers, spanning 0.51 mm (0.020 in) ultra-thin backplane wire at 30 AWG up to 4.27 mm (0.168 in) heavy 600 V power leads at 10 AWG across -70 °C to +200 °C.

Where PTFE and FEP cold-flow or notch under tight cable-tie clamping, robotic arm flexing, pump stator winding pressure or sheet-metal feedthroughs, ethylene-tetrafluoroethylene (ETFE) combines fluoropolymer chemical inertness and low dielectric constant (2.6) with engineering-plastic abrasion resistance and radiation tolerance up to 10^5 Gy. Melt-extrudable rheology allows long, continuous, splice-free production runs without PTFE paste-billet joints.

Specify UL 10086 (200 °C, 600 V, 0.25–0.51 mm wall) with silver- or nickel-plated stranded copper for compact motor leads and hot process cabinets, UL 1644 (150 °C, 600 V) or UL 1516 / UL 1523 (150 °C, 300 V) with tinned copper for high-density industrial control harnesses, or solid silver-plated UL 1422 (30–24 AWG) for automated wire-wrap backplanes (305 m or 500 m spools, 7 to 45 working days).

Explore the high-temperature wire and cable range for related configurations.

Construction

UL 10086, UL 1516 & UL 1644 ETFE Wire Construction

TEBAOFLEX manufactures single-core ETFE equipment wires on precision corrosion-resistant alloy melt extruders with inline laser diameter control and high-frequency spark testing.

Clean 2D engineering cross-section of UL 10086 extruded ETFE hook-up wire showing concentric cobalt-blue fluoropolymer wall over 19 silver-plated copper strands
UL 10086 cross-section: concentric cut-through-resistant ETFE insulation surrounding 19-strand copper conductor.
UL 10086, UL 1516 & UL 1523 Extruded ETFE Hook-Up Wire (150–200 °C, 300/600 V) construction
ComponentMaterial and construction
1. Plated Copper Conductor (30 AWG to 10 AWG)Concentric or unidirectional stranded annealed tinned copper (ASTM B33, up to +150 °C), silver-plated copper (ASTM B298, up to +200 °C on UL 10086), or nickel-plated copper (ASTM B355); solid silver-plated copper on UL 1422 / 1516 wire-wrap gauges.
2. Melt-Extruded ETFE Fluoropolymer InsulationHigh-purity ethylene-tetrafluoroethylene copolymer wall extruded to 0.11 mm (4.5–5 mil ultra-thin on UL 1516/1523), 0.25–0.38 mm (10–15 mil thin wall on UL 10086), or 0.51 mm (20 mil standard wall on UL 1644).
3. Colour Coding & Laser/Hot-Stamp StripingSolid pigment colours (black, white, red, blue, yellow, green, brown, orange, violet, grey) plus optional spiral tracer stripes for multi-wire industrial looms.

UL 10086 & UL 1516 ETFE Style Code Breakdown

  • ETFE: Ethylene-tetrafluoroethylene melt-extrudable fluoropolymer copolymer (high tensile & cut-through strength)
  • UL 10086: 600 V AC, +200 °C thin-wall (10–20 mil) extruded ETFE equipment wire (30–10 AWG)
  • UL 1644: 600 V AC, +150 °C standard-wall (20 mil) extruded ETFE motor and appliance lead wire
  • UL 1516 / 1523: 300 V AC, +150 °C ultra-thin-wall (5–6 mil) extruded ETFE harness and instrument wire
  • UL 1422: Solid silver-plated copper ultra-thin ETFE wire-wrap backplane conductor (30–24 AWG)
Applications

UL 10086 & UL 1516 Robotics, Pump & Backplane Applications

Engineered for equipment harnesses where chemical splash, high vibration, tight bend radii, radiation or sharp chassis edges rule out silicone or soft PTFE.

Industrial robotics and semiconductor wet-process equipment control cabinet wired with cobalt-blue and white UL 10086 and UL 1516 ETFE hook-up wire harnesses
High-density industrial actuator and wet-bench terminal cabinet wired with abrasion-resistant ETFE hook-up leads.
  • Industrial articulated robots, semiconductor wet-etch benches, electroplating rectifiers and automated pick-and-place gantry harnesses.
  • Submersible chemical transfer pump stator leads, Class F / Class H motor interconnect leads and hermetically sealed compressor terminals.
  • Nuclear instrumentation, medical sterilization autoclaves, analytical chromatographs and radiation-exposed sensor cabinets.
  • High-density PCB wire-wrap backplanes, test-fixture bed-of-nails wiring and compact instrumentation racks (UL 1422 / UL 1516 / UL 1523).

UL 10086 ETFE vs FEP vs PFA vs PTFE Hook-Up Wire

Extruded ETFE (UL 10086 / 1516) vs FEP (UL 1330 / 1332) vs PFA (UL 1727 / 10362) vs PTFE (UL 1180 / 1213)
Fluoropolymer FamilyTemp. EnvelopeMechanical Cut-Through & RadiationPrimary Selection Rule
ETFE — UL 10086 / 1516 (this page)-70 °C to +150 / +200 °CHighest tensile (42 MPa), pinch & 10 Mrad radiation toughnessRobotics, pump stators, wire-wrap backplanes & high-vibration chemical looms
FEP — UL 1330 / 1332-70 °C to +150 / +200 °CLower dielectric constant (2.1), softer wall, 1 Mrad limitGeneral 200 °C heaters, sensors & continuous splice-free appliance harnesses
PFA — UL 1726 / 1727 / 10362-80 °C to +250 / +260 °CContinuous 260 °C melt-extruded splice-free chemical immunitySemiconductor wet benches, 250 °C chemical reactors & long splice-free runs
PTFE — UL 1180 / 1213 / 1815-190 °C to +200 / +260 °CNon-melting sintered wall (soldering-iron proof), billet-length limitDense hand-soldered electronics, cryogenic leads & 260 °C dry instrument bays

Choose ETFE whenever abrasion, tie-wrap pinch force or gamma radiation degrades PTFE or FEP insulation.

UL 10086 & UL 1516 ETFE Wire RFQ Specification Checklist

  • Target UL AWM style reference (UL 10086 600 V 200 °C, UL 1644 600 V 150 °C, UL 1516/1523 300 V thin-wall, or solid UL 1422).
  • AWG size (30 AWG to 10 AWG) and conductor stranding (solid 1-wire, 7-strand, 19-strand or 37-strand).
  • Conductor plating (tinned copper up to +150 °C, silver-plated copper up to +200 °C, or nickel-plated copper).
  • Insulation base colour, optional spiral stripe code, and spool put-up (MOQ 305 m / 1,000 ft or 500 m per colour, 7 to 45 working days).

Related selection resources

UL 10086 & UL 1516 Extruded ETFE Wire FAQ

What is the difference between UL 10086 and UL 1516 ETFE hook-up wire?

2 core ratings separate them: UL 10086 uses a 10–20 mil (0.25–0.51 mm) ETFE wall rated 600 V and +200 °C with silver- or nickel-plated copper, whereas UL 1516 uses a 5–6 mil (0.13–0.15 mm) ultra-thin ETFE wall rated 300 V and +150 °C for compact electronic harnesses and backplanes.

Why specify UL 10086 ETFE instead of PTFE or FEP hook-up wire?

42 MPa tensile strength and 2x–3x higher cut-through resistance allow UL 10086 ETFE to survive sharp chassis bulkheads, robotic flexing, stator slot wedging and up to 10 Mrad radiation where soft PTFE or FEP cold-flows or cracks.

Does TEBAOFLEX supply UL 10086 and UL 1516 ETFE wire in continuous splice-free spools?

Yes — because ETFE is melt-extruded rather than billet paste-extruded like PTFE, TEBAOFLEX delivers 305 m (1,000 ft) and 500 m spools in 100 % continuous, spark-tested single lengths.

Which conductor plating is required for +200 °C continuous service on UL 10086?

Silver-plated copper (SPC) or nickel-plated copper (NPC) is required for continuous +200 °C duty; tinned copper (TPC) conductors are limited to +150 °C continuous to prevent tin-copper intermetallic embrittlement.

Do these UL 10086 and UL 1516 wires carry a third-party UL AWM Recognition mark?

No — TEBAOFLEX manufactures these ETFE hook-up wires engineered to UL 758 Style 10086, 1644, 1516, 1523 and 1422 dimensional and spark-test specifications (third-party UL/CSA mark is not claimed); minimum order is 305 m (1,000 ft) per colour with a 7 to 45 working days lead time.

Specifications

UL 10086, UL 1644, UL 1516 & UL 1422 Dimensional Schedule

UL 10086 & UL 1516 Key Voltage, Thermal & Spool Summary

  • Complete ETFE style coverage: Engineered to UL 758 Styles 10086 (200 °C, 600 V), 1644 (150 °C, 600 V), 1516 / 1523 (150 °C, 300 V) and solid 1422 backplane wire
  • Superior mechanical toughness: Extruded ETFE delivers 2x to 3x higher tensile strength (42 MPa) and pinch/cut-through resistance than soft PTFE or FEP hook-up wire
  • Radiation & chemical stability: Withstands up to 10 Mrad gamma radiation, aggressive acids, bases, ketones, hydraulic fluids and -70 °C cryogenic flexing
  • Plated copper to match duty: Stranded or solid tinned copper up to +150 °C, silver-plated copper up to +200 °C (UL 10086), or nickel-plated copper for corrosive atmospheres
  • Standard factory spool put-up: Supplied on 305 m (1,000 ft) or 500 m continuous melt-extruded factory spools per colour with 7 to 45 working days lead time
UL 10086, UL 1516 & UL 1523 Extruded ETFE Hook-Up Wire (150–200 °C, 300/600 V) technical data
ParameterValue
Rated voltage600 V AC (Styles 10086 and 1644), 300 V AC (Styles 1516 and 1523), or electronic backplane duty (Style 1422), spark-tested at 2500 V to 6000 V AC
Conductor and gauge range30 AWG to 10 AWG (0.05 mm2 to 5.26 mm2) in stranded (7 or 19 or 37 wires) or solid tinned, silver-plated or nickel-plated copper
Fluoropolymer insulation systemMelt-extruded ethylene-tetrafluoroethylene (ETFE) with 42 MPa tensile strength, 2.6 dielectric constant and VW-1 / FT1 flame resistance
Operating temperature and bend radius-70 C to +200 C continuous on UL 10086 (SPC/NPC) and -70 C to +150 C on UL 1516 / 1523 / 1644 (TPC), with 5x OD minimum fixed bend radius
Standard put-up and lead time305 m (1000 ft) or 500 m continuous splice-free factory spools per colour (MOQ 305 m / 300 m) in 7 to 45 working days
Standards compliance noteEngineered and manufactured to UL 758 AWM Styles 10086, 1644, 1516, 1523 and 1422 dimensional and electrical criteria (third-party UL/CSA mark is not claimed)
Radiation and fluid resistanceMaintains mechanical elongation up to 10 Mrad (10^5 Gy) gamma dose and resists acids, alkalis, halogens, alcohols and synthetic hydraulic oils

UL 10086 (200 °C) & UL 1644 (150 °C) 600 V ETFE Wire Schedule

Extruded ETFE Hook-Up Wire Engineered to UL 10086 (200 °C, 600 V) & UL 1644 (150 °C, 600 V) — Dimensional & Weight Schedule
Style & AWG GaugeTemp. / VoltageStranding (Wires/AWG)Conductor Ø (mm)Nom. Wall (mm / mil)Nom. OD (mm / in)Approx. Weight (kg/km)Standard Spool MOQNext step
UL 10086 26 AWG (SPC)200 °C / 600 V19/380.480.25 / 100.99 / 0.0392.4305 m / 500 mRequest this size
UL 10086 24 AWG (SPC)200 °C / 600 V19/360.610.25 / 101.12 / 0.0443.4305 m / 500 mRequest this size
UL 10086 22 AWG (SPC)200 °C / 600 V19/340.760.25 / 101.27 / 0.0504.9305 m / 500 mRequest this size
UL 10086 20 AWG (SPC)200 °C / 600 V19/320.970.25 / 101.47 / 0.0587.4305 m / 500 mRequest this size
UL 10086 18 AWG (SPC)200 °C / 600 V19/301.220.28 / 111.78 / 0.07011.3305 m / 500 mRequest this size
UL 10086 16 AWG (SPC)200 °C / 600 V19/291.450.30 / 122.06 / 0.08115.6305 m / 500 mRequest this size
UL 10086 14 AWG (SPC)200 °C / 600 V19/271.830.33 / 132.49 / 0.09824.1305 m spoolRequest this size
UL 10086 12 AWG (SPC)200 °C / 600 V37/282.290.38 / 153.05 / 0.12037.2305 m spoolRequest this size
UL 10086 10 AWG (SPC)200 °C / 600 V37/262.900.51 / 203.91 / 0.15459.8305 m spoolRequest this size
UL 1644 20 AWG (TPC)150 °C / 600 V7/280.970.51 / 201.98 / 0.0789.8305 m / 500 mRequest this size
UL 1644 18 AWG (TPC)150 °C / 600 V19/301.220.51 / 202.24 / 0.08813.9305 m / 500 mRequest this size
UL 1644 16 AWG (TPC)150 °C / 600 V19/291.450.51 / 202.46 / 0.09718.4305 m / 500 mRequest this size
UL 1644 14 AWG (TPC)150 °C / 600 V19/271.830.51 / 202.84 / 0.11227.5305 m spoolRequest this size
UL 1644 12 AWG (TPC)150 °C / 600 V19/252.310.51 / 203.33 / 0.13141.0305 m spoolRequest this size

UL 1516, UL 1523 & UL 1422 Thin-Wall 300 V & Wire-Wrap ETFE Schedule

Ultra-Thin-Wall & Solid Wire-Wrap ETFE Schedule Engineered to UL 1516, UL 1523 (150 °C, 300 V) & UL 1422
Style & AWG GaugeConductor BuildTemp. / VoltageNom. Wall (mm / mil)Nom. OD (mm / in)Approx. Weight (kg/km)Standard Spool MOQNext step
UL 1516 / UL 1422 30 AWGSolid 1/30 SPC150 °C / 300 V0.13 / 5.00.51 / 0.0200.8305 m / 500 mRequest this size
UL 1523 / UL 1422 28 AWGSolid 1/28 SPC150 °C / 300 V0.14 / 5.50.61 / 0.0241.2305 m / 500 mRequest this size
UL 1523 / UL 1422 26 AWGSolid 1/26 SPC150 °C / 300 V0.14 / 5.50.69 / 0.0271.8305 m / 500 mRequest this size
UL 1516 26 AWG Stranded7/34 TPC or SPC150 °C / 300 V0.15 / 6.00.79 / 0.0312.0305 m / 500 mRequest this size
UL 1516 24 AWG Stranded7/32 or 19/36150 °C / 300 V0.15 / 6.00.91 / 0.0362.9305 m / 500 mRequest this size
UL 1516 22 AWG Stranded7/30 or 19/34150 °C / 300 V0.15 / 6.01.07 / 0.0424.3305 m / 500 mRequest this size
UL 1516 20 AWG Stranded7/28 or 19/32150 °C / 300 V0.15 / 6.01.27 / 0.0506.5305 m / 500 mRequest this size

ASCII part references for BOM and ERP entry: TF-UL10086-24AWG, TF-UL10086-20AWG, TF-UL10086-18AWG, TF-UL10086-16AWG, TF-UL10086-12AWG, TF-UL1644-16AWG, TF-UL1516-24AWG, TF-UL1422-30AWG.

Continuous +200 °C rating on UL 10086 requires silver-plated (SPC) or nickel-plated (NPC) copper conductors; tinned copper (TPC) builds are rated to +150 °C continuous.

Standards

UL 10086 & UL 1516 Reference Standards & Test Protocol

UL 10086, UL 1516 & UL 1523 Extruded ETFE Hook-Up Wire (150–200 °C, 300/600 V) standards and test references
Standard or specificationApplication
UL 758 (Engineered to AWM Styles 10086, 1644, 1516, 1523 & 1422)Dimensional wall thickness, 2,500–6,000 V AC spark test, thermal aging and VW-1 vertical flame geometry for single-core ETFE appliance and equipment wire (third-party UL mark is not claimed).
ASTM B33 / ASTM B298 / ASTM B355Tinned copper, silver-plated copper and nickel-plated copper conductor stranding and DC resistance limits.
IEC 60332-1-2 / CSA FT1Single-wire vertical flame-retardant self-extinguishing performance without dripping flaming particles.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and routine spark/dielectric test records

UL 758 — Standard for Appliance Wiring Material (AWM)

IEC 60332-1-2 — Vertical flame propagation test for a single insulated wire or cable

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.