UL 10086, UL 1516 & UL 1523 Extruded ETFE Hook-Up Wire (150–200 °C, 300/600 V)
UL 10086, UL 1644, UL 1516, UL 1523 and UL 1422 extruded ETFE hook-up wires (150 V to 600 V AC, -70 °C to +150/+200 °C) combine tinned, silver-plated or nickel-plated copper conductors (30 AWG to 10 AWG) with high-modulus ethylene-tetrafluoroethylene fluoropolymer insulation for cut-through, radiation and chemical resistance.
UL 10086, UL 1644, UL 1516, UL 1523 and UL 1422 extruded ETFE single-core equipment wires fill the mechanical-toughness gap between standard PVC/XLPE cabinet wire and softer perfluoropolymers, spanning 0.51 mm (0.020 in) ultra-thin backplane wire at 30 AWG up to 4.27 mm (0.168 in) heavy 600 V power leads at 10 AWG across -70 °C to +200 °C.
Where PTFE and FEP cold-flow or notch under tight cable-tie clamping, robotic arm flexing, pump stator winding pressure or sheet-metal feedthroughs, ethylene-tetrafluoroethylene (ETFE) combines fluoropolymer chemical inertness and low dielectric constant (2.6) with engineering-plastic abrasion resistance and radiation tolerance up to 10^5 Gy. Melt-extrudable rheology allows long, continuous, splice-free production runs without PTFE paste-billet joints.
Specify UL 10086 (200 °C, 600 V, 0.25–0.51 mm wall) with silver- or nickel-plated stranded copper for compact motor leads and hot process cabinets, UL 1644 (150 °C, 600 V) or UL 1516 / UL 1523 (150 °C, 300 V) with tinned copper for high-density industrial control harnesses, or solid silver-plated UL 1422 (30–24 AWG) for automated wire-wrap backplanes (305 m or 500 m spools, 7 to 45 working days).
Explore the high-temperature wire and cable range for related configurations.
UL 10086, UL 1516 & UL 1644 ETFE Wire Construction
TEBAOFLEX manufactures single-core ETFE equipment wires on precision corrosion-resistant alloy melt extruders with inline laser diameter control and high-frequency spark testing.

| Component | Material and construction |
|---|---|
| 1. Plated Copper Conductor (30 AWG to 10 AWG) | Concentric or unidirectional stranded annealed tinned copper (ASTM B33, up to +150 °C), silver-plated copper (ASTM B298, up to +200 °C on UL 10086), or nickel-plated copper (ASTM B355); solid silver-plated copper on UL 1422 / 1516 wire-wrap gauges. |
| 2. Melt-Extruded ETFE Fluoropolymer Insulation | High-purity ethylene-tetrafluoroethylene copolymer wall extruded to 0.11 mm (4.5–5 mil ultra-thin on UL 1516/1523), 0.25–0.38 mm (10–15 mil thin wall on UL 10086), or 0.51 mm (20 mil standard wall on UL 1644). |
| 3. Colour Coding & Laser/Hot-Stamp Striping | Solid pigment colours (black, white, red, blue, yellow, green, brown, orange, violet, grey) plus optional spiral tracer stripes for multi-wire industrial looms. |
UL 10086 & UL 1516 ETFE Style Code Breakdown
- ETFE: Ethylene-tetrafluoroethylene melt-extrudable fluoropolymer copolymer (high tensile & cut-through strength)
- UL 10086: 600 V AC, +200 °C thin-wall (10–20 mil) extruded ETFE equipment wire (30–10 AWG)
- UL 1644: 600 V AC, +150 °C standard-wall (20 mil) extruded ETFE motor and appliance lead wire
- UL 1516 / 1523: 300 V AC, +150 °C ultra-thin-wall (5–6 mil) extruded ETFE harness and instrument wire
- UL 1422: Solid silver-plated copper ultra-thin ETFE wire-wrap backplane conductor (30–24 AWG)
UL 10086 & UL 1516 Robotics, Pump & Backplane Applications
Engineered for equipment harnesses where chemical splash, high vibration, tight bend radii, radiation or sharp chassis edges rule out silicone or soft PTFE.

- Industrial articulated robots, semiconductor wet-etch benches, electroplating rectifiers and automated pick-and-place gantry harnesses.
- Submersible chemical transfer pump stator leads, Class F / Class H motor interconnect leads and hermetically sealed compressor terminals.
- Nuclear instrumentation, medical sterilization autoclaves, analytical chromatographs and radiation-exposed sensor cabinets.
- High-density PCB wire-wrap backplanes, test-fixture bed-of-nails wiring and compact instrumentation racks (UL 1422 / UL 1516 / UL 1523).
UL 10086 ETFE vs FEP vs PFA vs PTFE Hook-Up Wire
| Fluoropolymer Family | Temp. Envelope | Mechanical Cut-Through & Radiation | Primary Selection Rule |
|---|---|---|---|
| ETFE — UL 10086 / 1516 (this page) | -70 °C to +150 / +200 °C | Highest tensile (42 MPa), pinch & 10 Mrad radiation toughness | Robotics, pump stators, wire-wrap backplanes & high-vibration chemical looms |
| FEP — UL 1330 / 1332 | -70 °C to +150 / +200 °C | Lower dielectric constant (2.1), softer wall, 1 Mrad limit | General 200 °C heaters, sensors & continuous splice-free appliance harnesses |
| PFA — UL 1726 / 1727 / 10362 | -80 °C to +250 / +260 °C | Continuous 260 °C melt-extruded splice-free chemical immunity | Semiconductor wet benches, 250 °C chemical reactors & long splice-free runs |
| PTFE — UL 1180 / 1213 / 1815 | -190 °C to +200 / +260 °C | Non-melting sintered wall (soldering-iron proof), billet-length limit | Dense hand-soldered electronics, cryogenic leads & 260 °C dry instrument bays |
Choose ETFE whenever abrasion, tie-wrap pinch force or gamma radiation degrades PTFE or FEP insulation.
UL 10086 & UL 1516 ETFE Wire RFQ Specification Checklist
- Target UL AWM style reference (UL 10086 600 V 200 °C, UL 1644 600 V 150 °C, UL 1516/1523 300 V thin-wall, or solid UL 1422).
- AWG size (30 AWG to 10 AWG) and conductor stranding (solid 1-wire, 7-strand, 19-strand or 37-strand).
- Conductor plating (tinned copper up to +150 °C, silver-plated copper up to +200 °C, or nickel-plated copper).
- Insulation base colour, optional spiral stripe code, and spool put-up (MOQ 305 m / 1,000 ft or 500 m per colour, 7 to 45 working days).
Related selection resources
- Browse all High-Temperature Fluoropolymer, Silicone & Mica Cables
- Compare UL 1330, UL 1331, UL 1332 & UL 1333 Extruded FEP Hook-Up Wire
- Upgrade to 250 °C UL 1726, UL 1727 & UL 10362 Extruded PFA Wire
- Compare UL 1180, UL 1213 & UL 1815 Extruded PTFE Equipment Wire
- Engineering guide: High-temperature wire insulation ratings compared
UL 10086 & UL 1516 Extruded ETFE Wire FAQ
What is the difference between UL 10086 and UL 1516 ETFE hook-up wire?
2 core ratings separate them: UL 10086 uses a 10–20 mil (0.25–0.51 mm) ETFE wall rated 600 V and +200 °C with silver- or nickel-plated copper, whereas UL 1516 uses a 5–6 mil (0.13–0.15 mm) ultra-thin ETFE wall rated 300 V and +150 °C for compact electronic harnesses and backplanes.
Why specify UL 10086 ETFE instead of PTFE or FEP hook-up wire?
42 MPa tensile strength and 2x–3x higher cut-through resistance allow UL 10086 ETFE to survive sharp chassis bulkheads, robotic flexing, stator slot wedging and up to 10 Mrad radiation where soft PTFE or FEP cold-flows or cracks.
Does TEBAOFLEX supply UL 10086 and UL 1516 ETFE wire in continuous splice-free spools?
Yes — because ETFE is melt-extruded rather than billet paste-extruded like PTFE, TEBAOFLEX delivers 305 m (1,000 ft) and 500 m spools in 100 % continuous, spark-tested single lengths.
Which conductor plating is required for +200 °C continuous service on UL 10086?
Silver-plated copper (SPC) or nickel-plated copper (NPC) is required for continuous +200 °C duty; tinned copper (TPC) conductors are limited to +150 °C continuous to prevent tin-copper intermetallic embrittlement.
Do these UL 10086 and UL 1516 wires carry a third-party UL AWM Recognition mark?
No — TEBAOFLEX manufactures these ETFE hook-up wires engineered to UL 758 Style 10086, 1644, 1516, 1523 and 1422 dimensional and spark-test specifications (third-party UL/CSA mark is not claimed); minimum order is 305 m (1,000 ft) per colour with a 7 to 45 working days lead time.
UL 10086, UL 1644, UL 1516 & UL 1422 Dimensional Schedule
UL 10086 & UL 1516 Key Voltage, Thermal & Spool Summary
- Complete ETFE style coverage: Engineered to UL 758 Styles 10086 (200 °C, 600 V), 1644 (150 °C, 600 V), 1516 / 1523 (150 °C, 300 V) and solid 1422 backplane wire
- Superior mechanical toughness: Extruded ETFE delivers 2x to 3x higher tensile strength (42 MPa) and pinch/cut-through resistance than soft PTFE or FEP hook-up wire
- Radiation & chemical stability: Withstands up to 10 Mrad gamma radiation, aggressive acids, bases, ketones, hydraulic fluids and -70 °C cryogenic flexing
- Plated copper to match duty: Stranded or solid tinned copper up to +150 °C, silver-plated copper up to +200 °C (UL 10086), or nickel-plated copper for corrosive atmospheres
- Standard factory spool put-up: Supplied on 305 m (1,000 ft) or 500 m continuous melt-extruded factory spools per colour with 7 to 45 working days lead time
| Parameter | Value |
|---|---|
| Rated voltage | 600 V AC (Styles 10086 and 1644), 300 V AC (Styles 1516 and 1523), or electronic backplane duty (Style 1422), spark-tested at 2500 V to 6000 V AC |
| Conductor and gauge range | 30 AWG to 10 AWG (0.05 mm2 to 5.26 mm2) in stranded (7 or 19 or 37 wires) or solid tinned, silver-plated or nickel-plated copper |
| Fluoropolymer insulation system | Melt-extruded ethylene-tetrafluoroethylene (ETFE) with 42 MPa tensile strength, 2.6 dielectric constant and VW-1 / FT1 flame resistance |
| Operating temperature and bend radius | -70 C to +200 C continuous on UL 10086 (SPC/NPC) and -70 C to +150 C on UL 1516 / 1523 / 1644 (TPC), with 5x OD minimum fixed bend radius |
| Standard put-up and lead time | 305 m (1000 ft) or 500 m continuous splice-free factory spools per colour (MOQ 305 m / 300 m) in 7 to 45 working days |
| Standards compliance note | Engineered and manufactured to UL 758 AWM Styles 10086, 1644, 1516, 1523 and 1422 dimensional and electrical criteria (third-party UL/CSA mark is not claimed) |
| Radiation and fluid resistance | Maintains mechanical elongation up to 10 Mrad (10^5 Gy) gamma dose and resists acids, alkalis, halogens, alcohols and synthetic hydraulic oils |
UL 10086 (200 °C) & UL 1644 (150 °C) 600 V ETFE Wire Schedule
| Style & AWG Gauge | Temp. / Voltage | Stranding (Wires/AWG) | Conductor Ø (mm) | Nom. Wall (mm / mil) | Nom. OD (mm / in) | Approx. Weight (kg/km) | Standard Spool MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| UL 10086 26 AWG (SPC) | 200 °C / 600 V | 19/38 | 0.48 | 0.25 / 10 | 0.99 / 0.039 | 2.4 | 305 m / 500 m | Request this size |
| UL 10086 24 AWG (SPC) | 200 °C / 600 V | 19/36 | 0.61 | 0.25 / 10 | 1.12 / 0.044 | 3.4 | 305 m / 500 m | Request this size |
| UL 10086 22 AWG (SPC) | 200 °C / 600 V | 19/34 | 0.76 | 0.25 / 10 | 1.27 / 0.050 | 4.9 | 305 m / 500 m | Request this size |
| UL 10086 20 AWG (SPC) | 200 °C / 600 V | 19/32 | 0.97 | 0.25 / 10 | 1.47 / 0.058 | 7.4 | 305 m / 500 m | Request this size |
| UL 10086 18 AWG (SPC) | 200 °C / 600 V | 19/30 | 1.22 | 0.28 / 11 | 1.78 / 0.070 | 11.3 | 305 m / 500 m | Request this size |
| UL 10086 16 AWG (SPC) | 200 °C / 600 V | 19/29 | 1.45 | 0.30 / 12 | 2.06 / 0.081 | 15.6 | 305 m / 500 m | Request this size |
| UL 10086 14 AWG (SPC) | 200 °C / 600 V | 19/27 | 1.83 | 0.33 / 13 | 2.49 / 0.098 | 24.1 | 305 m spool | Request this size |
| UL 10086 12 AWG (SPC) | 200 °C / 600 V | 37/28 | 2.29 | 0.38 / 15 | 3.05 / 0.120 | 37.2 | 305 m spool | Request this size |
| UL 10086 10 AWG (SPC) | 200 °C / 600 V | 37/26 | 2.90 | 0.51 / 20 | 3.91 / 0.154 | 59.8 | 305 m spool | Request this size |
| UL 1644 20 AWG (TPC) | 150 °C / 600 V | 7/28 | 0.97 | 0.51 / 20 | 1.98 / 0.078 | 9.8 | 305 m / 500 m | Request this size |
| UL 1644 18 AWG (TPC) | 150 °C / 600 V | 19/30 | 1.22 | 0.51 / 20 | 2.24 / 0.088 | 13.9 | 305 m / 500 m | Request this size |
| UL 1644 16 AWG (TPC) | 150 °C / 600 V | 19/29 | 1.45 | 0.51 / 20 | 2.46 / 0.097 | 18.4 | 305 m / 500 m | Request this size |
| UL 1644 14 AWG (TPC) | 150 °C / 600 V | 19/27 | 1.83 | 0.51 / 20 | 2.84 / 0.112 | 27.5 | 305 m spool | Request this size |
| UL 1644 12 AWG (TPC) | 150 °C / 600 V | 19/25 | 2.31 | 0.51 / 20 | 3.33 / 0.131 | 41.0 | 305 m spool | Request this size |
UL 1516, UL 1523 & UL 1422 Thin-Wall 300 V & Wire-Wrap ETFE Schedule
| Style & AWG Gauge | Conductor Build | Temp. / Voltage | Nom. Wall (mm / mil) | Nom. OD (mm / in) | Approx. Weight (kg/km) | Standard Spool MOQ | Next step |
|---|---|---|---|---|---|---|---|
| UL 1516 / UL 1422 30 AWG | Solid 1/30 SPC | 150 °C / 300 V | 0.13 / 5.0 | 0.51 / 0.020 | 0.8 | 305 m / 500 m | Request this size |
| UL 1523 / UL 1422 28 AWG | Solid 1/28 SPC | 150 °C / 300 V | 0.14 / 5.5 | 0.61 / 0.024 | 1.2 | 305 m / 500 m | Request this size |
| UL 1523 / UL 1422 26 AWG | Solid 1/26 SPC | 150 °C / 300 V | 0.14 / 5.5 | 0.69 / 0.027 | 1.8 | 305 m / 500 m | Request this size |
| UL 1516 26 AWG Stranded | 7/34 TPC or SPC | 150 °C / 300 V | 0.15 / 6.0 | 0.79 / 0.031 | 2.0 | 305 m / 500 m | Request this size |
| UL 1516 24 AWG Stranded | 7/32 or 19/36 | 150 °C / 300 V | 0.15 / 6.0 | 0.91 / 0.036 | 2.9 | 305 m / 500 m | Request this size |
| UL 1516 22 AWG Stranded | 7/30 or 19/34 | 150 °C / 300 V | 0.15 / 6.0 | 1.07 / 0.042 | 4.3 | 305 m / 500 m | Request this size |
| UL 1516 20 AWG Stranded | 7/28 or 19/32 | 150 °C / 300 V | 0.15 / 6.0 | 1.27 / 0.050 | 6.5 | 305 m / 500 m | Request this size |
ASCII part references for BOM and ERP entry: TF-UL10086-24AWG, TF-UL10086-20AWG, TF-UL10086-18AWG, TF-UL10086-16AWG, TF-UL10086-12AWG, TF-UL1644-16AWG, TF-UL1516-24AWG, TF-UL1422-30AWG.
Continuous +200 °C rating on UL 10086 requires silver-plated (SPC) or nickel-plated (NPC) copper conductors; tinned copper (TPC) builds are rated to +150 °C continuous.
UL 10086 & UL 1516 Reference Standards & Test Protocol
| Standard or specification | Application |
|---|---|
| UL 758 (Engineered to AWM Styles 10086, 1644, 1516, 1523 & 1422) | Dimensional wall thickness, 2,500–6,000 V AC spark test, thermal aging and VW-1 vertical flame geometry for single-core ETFE appliance and equipment wire (third-party UL mark is not claimed). |
| ASTM B33 / ASTM B298 / ASTM B355 | Tinned copper, silver-plated copper and nickel-plated copper conductor stranding and DC resistance limits. |
| IEC 60332-1-2 / CSA FT1 | Single-wire vertical flame-retardant self-extinguishing performance without dripping flaming particles. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and routine spark/dielectric test records
UL 758 — Standard for Appliance Wiring Material (AWM)
IEC 60332-1-2 — Vertical flame propagation test for a single insulated wire or cable
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
FEP Hook-Up Wire — UL 1330, UL 1331, UL 1332 & UL 1333 Wire (150–200 °C, 300/600 V)
A related cable option for a different application or duty profile.
View productPFA Hook-Up Wire — UL 1726, UL 1727 & UL 10362 Extruded Wire (250 °C, 300/600 V)
A related cable option for a different application or duty profile.
View productPTFE Hook-Up Wire — UL 1180, UL 1199, UL 1213, UL 1815 & UL 1584 (200–260 °C)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.