Get a Quote
High Temperature Cables

UL 10503 PFA Equipment Wire, 250°C 600V

UL 10503 is a UL-certified PFA wire rated 250°C and 600 V AC for internal equipment wiring. The listed configurations extend from 30 AWG to 10 AWG, allowing the same product page to support both small connection leads and larger conductor selections.

  • Voltage: 600 V AC
  • Temperature: 250°C
  • Insulation / covering: extruded PFA
  • Size selection: 30–10 AWG in dimension table
  • Certification: UL-certified AWM; UL 758
Product information
Product overview

UL 10503 wire selection

UL 10503 is a UL-certified PFA wire rated 250°C and 600 V AC for internal equipment wiring. The listed configurations extend from 30 AWG to 10 AWG, allowing the same product page to support both small connection leads and larger conductor selections.

The insulation wall changes within the table: 18–30 AWG rows use a nominal 0.20 mm wall, while 10–16 AWG rows use 0.30 mm. Each row also identifies stranding, conductor diameter, minimum wall, finished diameter and conductor resistance at 20°C. Keeping the model and AWG together makes it easier to specify the intended configuration when requesting a replacement or comparing harness drawings.

Review conductor size, wall thickness and finished diameter together before changing an existing PFA lead. A larger conductor can change the entry clearance and terminal geometry as well as the electrical characteristics. Where a small-gauge alternative is being considered, compare the exact style marking and conductor construction; a shared 600 V and 250°C rating does not make two products dimensionally identical.

See the Specifications tab for the model and size tables. Browse the high-temperature cable range for related constructions. Compare UL 10485 for small gauges and the PFA wire family for other PFA voltage or temperature options.

Construction

Construction

UL 10503 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

Illustrative UL 10503 single-core conductor and insulation construction cutaway
Illustrative UL 10503 construction; layer dimensions are not to scale.
UL 10503 construction layers
ComponentConstruction detail
ConductorCopper; bare or plated construction selected for the temperature and termination
InsulationExtruded PFA
ConstructionSingle insulated conductor
Applications

Applications

UL 10503 is used for internal wiring of appliances or electronic equipment where the specified PFA construction, conductor size and temperature rating match the circuit.

Illustrative UL 10503 insulated lead routed inside industrial equipment
Illustrative UL 10503 equipment application; shown as an installation concept.

UL 10503 replacement selection

For replacement enquiries, include the existing wire marking and the equipment connection drawing so the conductor, insulation and terminal arrangement can be matched.

Specifications

Specifications

UL 10503 technical data
ParameterSpecification
UL styleUL 10503
Voltage rating600 V AC
Temperature rating250°C
Insulation / coveringextruded PFA
Conductor size coverage30–10 AWG in dimension table
Resistance reference temperature20°C
Dimensional unitsmm
Strand-diameter tolerance in table±0.005 mm
Nominal / minimum wall, 18–30 AWG0.20 / 0.15 mm
Nominal / minimum wall, 10–16 AWG0.30 / 0.27 mm

Dimensions and resistance are nominal catalogue values for the listed constructions. Solid and stranded versions must be specified separately. Use the agreed drawing for termination tolerances.

UL 10503 size and dimension table
Model and conductor sizeStranding (No./mm)Conductor dia. (mm)Nominal wall (mm)Minimum wall (mm)Nominal OD / tolerance (mm)Conductor resistance at 20°C (Ω/km)
UL 10503 10 AWG37/0.422.940.300.273.54 ±0.153.54
UL 10503 12 AWG37/0.3742.620.300.273.22 ±0.155.64
UL 10503 14 AWG19/0.3611.850.300.272.41 ±0.108.96
UL 10503 16 AWG19/0.2871.500.300.272.04 ±0.1014.60
UL 10503 18 AWG19/0.2351.180.200.151.57 ±0.1023.20
UL 10503 20 AWG19/0.190.950.200.151.36 ±0.1036.70
UL 10503 22 AWG19/0.150.760.200.151.15 ±0.1059.40
UL 10503 24 AWG7/0.200.610.200.151.00 ±0.1094.20
UL 10503 26 AWG7/0.160.480.200.150.88 ±0.10150.00
UL 10503 28 AWG1/0.320.320.200.150.72 ±0.10227.00
UL 10503 30 AWG1/0.2540.2540.200.150.66 ±0.10361.00

Selecting the specified construction

State UL 10503, AWG and solid or stranded construction on the enquiry. Check the conductor finish, finished diameter and strip dimensions before substituting another PFA style.

For tight-clearance connections, use the agreed finished-diameter drawing: nominal conductor diameter and nominal wall values in the table do not always sum exactly to the listed outside diameter.

Standards

Standards

TEBAOFLEX UL 10503 wire is UL-certified appliance wiring material.

UL 10503 certification and standards
ItemRequirement or reference
CertificationUL-certified AWM
Style designationUL 10503
Construction standardUL 758 — Appliance Wiring Material
Style flame classificationHorizontal flame

Identify the UL style, conductor size, voltage and temperature grade on the purchasing specification. Include the required product identification and certification documents with the enquiry.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.