UL 10503 PFA Equipment Wire, 250°C 600V
UL 10503 is a UL-certified PFA wire rated 250°C and 600 V AC for internal equipment wiring. The listed configurations extend from 30 AWG to 10 AWG, allowing the same product page to support both small connection leads and larger conductor selections.
- Voltage: 600 V AC
- Temperature: 250°C
- Insulation / covering: extruded PFA
- Size selection: 30–10 AWG in dimension table
- Certification: UL-certified AWM; UL 758
UL 10503 wire selection
UL 10503 is a UL-certified PFA wire rated 250°C and 600 V AC for internal equipment wiring. The listed configurations extend from 30 AWG to 10 AWG, allowing the same product page to support both small connection leads and larger conductor selections.
The insulation wall changes within the table: 18–30 AWG rows use a nominal 0.20 mm wall, while 10–16 AWG rows use 0.30 mm. Each row also identifies stranding, conductor diameter, minimum wall, finished diameter and conductor resistance at 20°C. Keeping the model and AWG together makes it easier to specify the intended configuration when requesting a replacement or comparing harness drawings.
Review conductor size, wall thickness and finished diameter together before changing an existing PFA lead. A larger conductor can change the entry clearance and terminal geometry as well as the electrical characteristics. Where a small-gauge alternative is being considered, compare the exact style marking and conductor construction; a shared 600 V and 250°C rating does not make two products dimensionally identical.
See the Specifications tab for the model and size tables. Browse the high-temperature cable range for related constructions. Compare UL 10485 for small gauges and the PFA wire family for other PFA voltage or temperature options.
Construction
UL 10503 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

| Component | Construction detail |
|---|---|
| Conductor | Copper; bare or plated construction selected for the temperature and termination |
| Insulation | Extruded PFA |
| Construction | Single insulated conductor |
Applications
UL 10503 is used for internal wiring of appliances or electronic equipment where the specified PFA construction, conductor size and temperature rating match the circuit.

UL 10503 replacement selection
For replacement enquiries, include the existing wire marking and the equipment connection drawing so the conductor, insulation and terminal arrangement can be matched.
Specifications
| Parameter | Specification |
|---|---|
| UL style | UL 10503 |
| Voltage rating | 600 V AC |
| Temperature rating | 250°C |
| Insulation / covering | extruded PFA |
| Conductor size coverage | 30–10 AWG in dimension table |
| Resistance reference temperature | 20°C |
| Dimensional units | mm |
| Strand-diameter tolerance in table | ±0.005 mm |
| Nominal / minimum wall, 18–30 AWG | 0.20 / 0.15 mm |
| Nominal / minimum wall, 10–16 AWG | 0.30 / 0.27 mm |
Dimensions and resistance are nominal catalogue values for the listed constructions. Solid and stranded versions must be specified separately. Use the agreed drawing for termination tolerances.
| Model and conductor size | Stranding (No./mm) | Conductor dia. (mm) | Nominal wall (mm) | Minimum wall (mm) | Nominal OD / tolerance (mm) | Conductor resistance at 20°C (Ω/km) |
|---|---|---|---|---|---|---|
| UL 10503 10 AWG | 37/0.42 | 2.94 | 0.30 | 0.27 | 3.54 ±0.15 | 3.54 |
| UL 10503 12 AWG | 37/0.374 | 2.62 | 0.30 | 0.27 | 3.22 ±0.15 | 5.64 |
| UL 10503 14 AWG | 19/0.361 | 1.85 | 0.30 | 0.27 | 2.41 ±0.10 | 8.96 |
| UL 10503 16 AWG | 19/0.287 | 1.50 | 0.30 | 0.27 | 2.04 ±0.10 | 14.60 |
| UL 10503 18 AWG | 19/0.235 | 1.18 | 0.20 | 0.15 | 1.57 ±0.10 | 23.20 |
| UL 10503 20 AWG | 19/0.19 | 0.95 | 0.20 | 0.15 | 1.36 ±0.10 | 36.70 |
| UL 10503 22 AWG | 19/0.15 | 0.76 | 0.20 | 0.15 | 1.15 ±0.10 | 59.40 |
| UL 10503 24 AWG | 7/0.20 | 0.61 | 0.20 | 0.15 | 1.00 ±0.10 | 94.20 |
| UL 10503 26 AWG | 7/0.16 | 0.48 | 0.20 | 0.15 | 0.88 ±0.10 | 150.00 |
| UL 10503 28 AWG | 1/0.32 | 0.32 | 0.20 | 0.15 | 0.72 ±0.10 | 227.00 |
| UL 10503 30 AWG | 1/0.254 | 0.254 | 0.20 | 0.15 | 0.66 ±0.10 | 361.00 |
Selecting the specified construction
State UL 10503, AWG and solid or stranded construction on the enquiry. Check the conductor finish, finished diameter and strip dimensions before substituting another PFA style.
For tight-clearance connections, use the agreed finished-diameter drawing: nominal conductor diameter and nominal wall values in the table do not always sum exactly to the listed outside diameter.
Standards
TEBAOFLEX UL 10503 wire is UL-certified appliance wiring material.
| Item | Requirement or reference |
|---|---|
| Certification | UL-certified AWM |
| Style designation | UL 10503 |
| Construction standard | UL 758 — Appliance Wiring Material |
| Style flame classification | Horizontal flame |
Identify the UL style, conductor size, voltage and temperature grade on the purchasing specification. Include the required product identification and certification documents with the enquiry.
Request a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.