NTMCGCWÖU Single-Core MV Cable 3.6/6kV to 18/30kV
NTMCGCWÖU / NTMCGCWOEU is a screened single-core flexible MV cable for short transformer, switchgear, mining and industrial power links.
- Voltage family: 3.6/6kV through 18/30kV by confirmed construction
- Conductor: Class 5 finely stranded tinned copper
- Insulation: EPR with semiconductive field-control layers
- Screen: Tinned-copper wire screen
- Sheath: Heavy-duty red rubber compound
- Ordering: RFQ only; confirm voltage, size, bonding, route and duty
NTMCGCWÖU Single-Core Medium-Voltage Cable
NTMCGCWÖU cable is a flexible, screened single-core rubber cable for short medium-voltage connections in mines, mobile transformer substations, switchgear, railway equipment and heavy industrial power systems. International specifications may write the same designation as NTMCGCWOEU or NTMCGCWOU when the “Ö” character is unavailable. This page consolidates those spellings and the former separate 18/30kV listing into one technical selection path.
The cable family combines a Class 5 finely stranded tinned-copper conductor, semiconductive electrical-field-control layers, EPR insulation, a tinned-copper wire screen and a heavy-duty red rubber sheath. The general family can be reviewed from 3.6/6kV through 18/30kV; the detailed table below records the existing 18/30kV reference construction with a 43kV test voltage and 1×25/16mm² to 1×240/25mm² size range.
NTMCGCWÖU is intended for short flexible links and connection work, not automatically for continuous drum reeling. Selection requires system voltage, conductor cross-section, screen size and bonding method, route length, bending radius, installation mode, short-circuit duty, ambient conditions and required standards. Final ampacity, diameter and weight must be confirmed on the order datasheet. For dynamic movement, compare the R-(N)TSCGEWÖU reeling cable or send the installation drawing through the engineering enquiry form.
NTMCGCWÖU Cable Construction
| Layer | Construction | Selection purpose |
|---|---|---|
| Conductor | Class 5 finely stranded tinned electrolytic copper | Supports flexible installation and conductor surface protection. |
| Conductor screen | Semiconductive layer | Controls electrical stress at the conductor-insulation interface. |
| Insulation | EPR compound | Provides the dielectric layer for the selected MV class. |
| Insulation screen | Semiconductive layer over insulation | Controls the outer insulation interface. |
| Metallic screen | Tinned-copper wires; 16mm² or 25mm² in the 18/30kV reference range | Provides the metallic screen and fault-current path defined by the system design. |
| Outer sheath | Red 5GM3 rubber in the 18/30kV reference construction | External mechanical and environmental protection. |
The screen cross-section, sheath compound, insulation thickness and completed diameter change with voltage and conductor size. Confirm all layer dimensions on the quotation drawing.
Applications and Cable-Type Boundaries
- Short connections between mobile transformer substations and overhead-line interfaces.
- Medium-voltage switchgear, control-panel and transformer-house links.
- Mining and heavy-industrial distribution connections with limited routing space.
- Railway vehicle or equipment connections when the project specification accepts the construction.
When another cable is required
Use a dedicated reeling cable for continuous drum winding, repeated high-speed movement or tightly controlled S-bend routes. Use a multicore mine-distribution cable when the circuit requires three phase cores, earth, control or monitoring elements in one construction. Useful alternatives include (N)TSCGEWÖU mine-distribution cable and (N)TMCETMPU portable trailing cable.
RFQ data
Provide system voltage, conductor and screen cross-sections, current and fault duty, route length, termination and bonding arrangement, minimum bend radius, installation temperature, oil/UV/moisture exposure, drum length and required test documentation.
NTMCGCWÖU Specifications
| Product family | Flexible screened single-core medium-voltage rubber cable |
|---|---|
| Designations | NTMCGCWÖU / NTMCGCWOEU / NTMCGCWOU |
| Voltage family | 3.6/6kV, 6/10kV, 8.7/15kV, 12/20kV, 14/25kV and 18/30kV by confirmed construction |
| Conductor | Class 5 finely stranded tinned copper |
| Insulation and field control | EPR insulation with semiconductive layers |
| Metallic screen | Tinned-copper wire screen sized for the circuit fault duty |
| Primary use | Short flexible single-core MV connections; not an automatic drum-reeling selection |
18/30kV Reference Construction
| Product Name | 18/30 kV NTMCGCWOEU Cable |
| Cable Type | Flexible single core medium voltage power cable |
| Type Reference | NTMCGCWOEU / SCANFLEX-type construction |
| Rated Voltage | 18/30 kV |
| Test Voltage | 43 kV |
| Conductor | Class 5 finely stranded tinned electrolytic copper |
| Insulation | Ethylene propylene rubber (EPR) |
| Screen | Spinning of tinned copper wires, 16 or 25 mm² |
| Outer Sheath | Red 5GM3 rubber compound |
| Temperature Range | Fixed: -40°C to +90°C; flexible: -25°C to +60°C |
| Bending Radius | Fixed: 6 x cable diameter; flexible: 10 x cable diameter |
| Packaging | Drum |
18/30kV Size Reference
| Dimension | Current Value | Diameter | Weight |
| 1x25/16 mm² | 189 A | 35.3 mm | 1600 kg/km |
| 1x35/16 mm² | 234 A | 37.3 mm | 1830 kg/km |
| 1x50/16 mm² | 294 A | 38.9 mm | 2030 kg/km |
| 1x70/16 mm² | 360 A | 41.0 mm | 2325 kg/km |
| 1x95/16 mm² | 434 A | 42.4 mm | 2600 kg/km |
| 1x120/16 mm² | 505 A | 43.9 mm | 2900 kg/km |
| 1x150/25 mm² | 582 A | 46.8 mm | 3385 kg/km |
| 1x185/25 mm² | 664 A | 50.0 mm | 3940 kg/km |
| 1x240/25 mm² | 782 A | 51.8 mm | 4485 kg/km |
Data-use note: these tables preserve the former 18/30kV product page data. Confirm the current project datasheet, ampacity method, screen fault duty, dimensions and bending radius before ordering.
Standards and Documentation
| Reference | Role | Order control |
|---|---|---|
| DIN VDE 0250-813 | Design reference used for flexible rubber-insulated MV cable constructions | Confirm the applicable construction and edition. |
| EN / IEC 60228 | Conductor class and resistance reference | Verify on the final technical data sheet. |
| DIN VDE 0298 | Installation and use reference | Bending and current conditions remain route-specific. |
| IEC 60332-1-2 | Single-cable flame-propagation test reference | Claim only when included in the supplied test scope. |
| IEC 60811-404 | Oil-resistance test reference | Confirm the exact sheath compound and result. |
RoHS, railway or other project compliance must be supported by order-specific documentation. A standards list on this page is not a certificate or approval statement.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
(N)TSCGEWÖU Cable 3.6/6kV to 12/20kV Mine Distribution Cable
A related cable option for a different application or duty profile.
View productR-(N)TSCGEWÖU Medium Voltage Reeling Cable 3.6/6–18/30 kV
For continuous drum reeling and higher dynamic movement.
View product(N)TMCETMPU Cable 6/10 kV to 14/25 kV Portable Mining Trailing Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.