SiHF-J Silicone 180 Multi Core Flexible Cable
SiHF-J Silicone 180 Multi Core Flexible Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. SiHF-J cable is a multi core silicone rubber flexible cable designed for connecting electrical appliances in high temperature or low temperature environments where no mechanical stress is present. The source record places this product in high temperature cables. Before ordering, confirm the exact product variant, conductor or core arrangement, system rating, route conditions, equipment connection and required documentation against the project specification. Send the exact size, length, installation duty and documentation requirements for a technical quotation.
SiHF-J Silicone 180 Multi Core Flexible Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. SiHF-J cable is a multi core silicone rubber flexible cable designed for connecting electrical appliances in high temperature or low temperature environments where no mechanical stress is present. The source record places this product in high temperature cables. Before ordering, confirm the exact product variant, conductor or core arrangement, system rating, route conditions, equipment connection and required documentation against the project specification. The requested SiHF-J Silicone 180 Multi Core Flexible Cable should be evaluated as a complete cable assembly: review its intended equipment, conductor arrangement, installation method, movement duty, environment, terminations, dimensions and required documentation together. The V2 layout keeps the source-listed construction, application, technical and standard information available for a controlled engineering and procurement review. Use the Request Quote section to confirm the exact configuration, route conditions and documentation requirements before production or replacement ordering. For a reliable quotation, provide the cable marking, requested length, installation environment, load or signal duty, termination details and any required test or compliance documents.
SiHF-J Silicone 180 Multi Core Flexible Cable construction
Cable Construction
- Conductor: Class 5 flexible stranded tinned copper conductor.
- Insulation: Silicone rubber insulation for high and low temperature performance.
- Outer Sheath: Silicone rubber sheath with resistance to most oils, acids, lyes and oxidants.
- Core Identification: 3 cores: green/yellow, blue and brown; 4 cores: green/yellow, blue, black and grey; 5 cores: green/yellow, blue, brown, black and grey; more than 5 cores: black numbered cores plus green/yellow.
SiHF-J Silicone 180 Multi Core Flexible Cable applications
Applications
- Connection of electrical appliances without mechanical stress
- Equipment wiring in high ambient temperature areas
- Steelworks and heat-exposed industrial environments
- Low temperature installations requiring flexible silicone cable
- Appliance and machinery connections exposed to oils, acids, lyes or oxidants
- Industrial control and power connections where multi core silicone cable is required
Where steel-processing, kiln or glass-plant equipment runs hotter than the SiHF-J silicone rating allows, the 450°C multicore mica-glass high-temperature cable groups glass-reinforced mica tape insulated conductors under a finished fibreglass outer braid.
Selection checks
Confirm the equipment interface, installation method, route length, movement or flexing duty, environmental exposure, conductor or core requirements and project documentation before final selection.
SiHF-J Silicone 180 Multi Core Flexible Cable specifications
The source-listed technical notes are retained below. Confirm the final size, tolerance, installation basis and ordered configuration before release.
SiHF-J Cable for High Temperature Appliance Connections
SiHF-J cable is a 300/500V multi core silicone rubber cable used for the connection of electrical appliances in demanding temperature conditions. It is suitable for fixed or limited-flexing installations without mechanical stress, including high temperature areas such as steelworks and low temperature environments where ordinary PVC cables may become unsuitable.
Available Core and Size Options
SiHF-J Silicone 180 cable is available in 3, 4, 5, 7, 12, 18, 24 and 25 core constructions. Common conductor sizes include 0.75mm², 1mm², 1.5mm², 2.5mm², 4mm², 6mm², 10mm², 16mm², 25mm², 35mm² and 50mm², depending on the number of cores required for the installation.
Source-listed technical tables
The tables below retain the original product data, including units, ranges and ordering examples.
| Product Name | SiHF-J Silicone 180 Multi Core Flexible Cable |
| Cable Type | Multi core silicone rubber flexible cable |
| Voltage Rating | 300/500V |
| Temperature Rating | Fixed installation: -60°C to +180°C |
| Conductor | Class 5 flexible stranded tinned copper |
| Insulation | Silicone rubber |
| Outer Sheath | Silicone rubber |
| Sheath Colour | Red |
| Core Range | 3 cores to 25 cores |
| Conductor Size Range | 0.75mm² to 50mm² depending on core count |
| Minimum Bending Radius | Fixed: 5 x overall diameter; flexed: 15 x overall diameter |
| Standard | VDE 0482-332-1-2 |
| Flame Retardant Standard | IEC 60332-1-2 |
SiHF-J Silicone 180 Multi Core Flexible Cable standards and compliance
The following standard references are carried over from the original product record. They identify the source basis and do not replace project-specific certification or inspection requirements.
- Flame retardant performance: Flame retardant according to IEC 60332-1-2.
- Standard VDE 0482-332-1-2
- Flame Retardant Standard IEC 60332-1-2
Where a project requires a test report, certificate, marking record or inspection release, include that requirement in the quotation request.
Request a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.