High Temperature Cables TEBAOFLEX

SiHF-P & SiHF/GLS-P GSWB Armoured Silicone Cable (300/500 V, 180 °C)

TEBAOFLEX SiHF-P (also specified as SiHF-GL-P and SiHF/GLS-P) is a 300/500 V mechanically armoured high-temperature multicore cable pairing IEC 60228 Class 5 tinned copper conductors (2×0.75 mm² to 4G35 mm² and up to 24G1.5 mm²), halogen-free silicone core insulation and inner sheath, a glass-fibre barrier layer, and an external galvanized steel wire braid (GSWB) for -60 °C to +180 °C (+200 °C peak) hot-zone duty.

Product information
SKU
SiHF-P
Brand
TEBAOFLEX
Product overview

TEBAOFLEX SiHF-P (cross-referenced on European steelplant drawings as SiHF-GL-P and SiHF/GLS-P) is a 300/500 V (2,000 V AC test) armoured multicore power and control cable engineered with IEC 60228 Class 5 tinned copper conductors, cross-linked silicone rubber core insulation and brick-red inner bedding, a woven glass-fibre thermal barrier, and an exposed galvanized steel wire braid (GSWB) across 7.5 mm to 30.4 mm outer diameter.

Unarmoured SiHF-J silicone jackets stay supple at +180 °C, but hot metal chips, grate edges, foundry slag splash and mechanical abrasion can cut unreinforced silicone during maintenance. Wrapping a glass-fibre tape/braid and a high-tensile galvanized steel wire braid around the brick-red silicone bedding delivers crush, cut-through and rodent protection while maintaining a 10x OD fixed and 15x OD occasional flexing bend radius from -60 °C to +180 °C.

Specify SiHF-P / SiHF/GLS-P for exposed cable trays, kiln damper actuators, furnace lance drives, glass-annealing lehrs and petrochemical heat-tracing junction runs; select EMC copper-braided SiHFC / SiHF-C-Si instead where high-frequency VFD/sensor shielding is the primary requirement, or unarmoured SiHF-J inside protected conduits. Supplied from a 50 m minimum order quantity with a 7 to 45 working days lead time.

Explore the high-temperature wire and cable range for related configurations.

Construction

SiHF-P & SiHF/GLS-P GSWB Armoured Silicone Construction

Manufactured in accordance with DIN VDE 0250 / EN 50525-2-83 silicone elastomer guidelines, IEC 60228 Class 5 stranding and galvanized steel wire armouring practices.

Clean 2D engineering cross-section of 4G2.5 mm² SiHF-P armoured silicone cable showing four Class 5 tinned copper cores with brown, black, grey and green-yellow silicone insulation, brick-red silicone inner sheath, glass barrier ring and outer galvanized steel wire braid
SiHF-P 4G cross-section: Class 5 tinned copper conductors, VDE colour-coded silicone insulation, brick-red silicone inner sheath, glass barrier and GSWB armour.
SiHF-P & SiHF/GLS-P GSWB Armoured Silicone Cable (300/500 V, 180 °C) construction
ComponentMaterial and construction
1. Fine-Stranded Tinned Copper Conductors (Class 5)Electrolytic tin-plated copper wires stranded to IEC 60228 / VDE 0295 Class 5 (0.75 mm² to 35 mm²) to prevent high-temperature copper scaling and preserve low contact resistance.
2. Silicone Rubber Core Insulation & Core IdentificationHeat-vulcanized halogen-free silicone rubber (EI2 / 2GI1 grade); colour-coded per DIN VDE 0293-308 (HD 308 S2) up to 5 cores, and black cores with white sequential numbers plus green-yellow earth from 6 cores upward.
3. Extruded Brick-Red Silicone Inner Sheath (Bedding)Concentric brick-red silicone rubber inner sheath filling core interstices to establish a firm, circular moisture-resistant bedding beneath the armour.
4. Glass-Fibre Thermal Barrier & Galvanized Steel Wire Braid (GSWB)Lapped/braided E-glass fibre anti-chafe separator overlaid with a corrosion-resistant galvanized steel wire braid (~75%–85% optical coverage) providing mechanical impact, abrasion and rodent defence.

SiHF-P, SiHF-GL-P & SiHF/GLS-P Code Breakdown

  • Si: Heat-resistant halogen-free silicone rubber core insulation and inner bedding (-60 °C to +180 °C)
  • HF: Fine-stranded flexible IEC 60228 Class 5 tinned copper conductors for multi-core power/control
  • GL / GLS: Woven or lapped glass-fibre thermal and anti-chafe barrier beneath the steel braid
  • P: External galvanized steel wire braid (`Panzergeflecht` / GSWB) for cut, impact and rodent protection
  • G / X: `G` denotes inclusion of one green-yellow protective earth core (e.g., 4G2.5); `X` omits green-yellow (e.g., 2x1.5)
Applications

SiHF-P Steelworks, Foundry & Glass-Furnace Applications

Deploy SiHF-P / SiHF-GL-P / SiHF/GLS-P wherever ambient radiant heat (-60 °C to +180 °C) coincides with mechanical abrasion, metal swarf or exposed tray routing.

Steelworks continuous-casting furnace zone showing galvanized steel wire braided SiHF-P high-temperature silicone cables clamped in brass armour glands along a hot-metal structural walkway
Foundry and steelworks hot-zone actuator wiring protected against slag splash and abrasion by GSWB armoured SiHF-P cable.
  • Steelworks continuous-casting runout tables, blast-furnace tuyere instrumentation, ladle preheater blowers and hot-rolling mill auxiliary drives.
  • Glass-melting tank regenerators, float-glass annealing lehrs, ceramic tunnel kilns and aluminium extrusion billet heaters.
  • Foundry shakeout decks, die-casting cell hydraulic valve manifolds, cement clinker cooler fans and industrial incinerator dampers.
  • Cold-storage blast freezers (-60 °C), marine engine-room hot exhaust zones and industrial plant zones requiring halogen-free rodent-resistant cabling.

SiHF-P (GSWB) vs SiHFC (EMC) vs Unarmoured SiHF-J

SiHF-P (GSWB Steel Armoured) vs SiHFC / SiHF-C-Si (Copper EMC Screened) vs Unarmoured SiHF-J vs SIMH FE180
Cable TypeOuter Metallic LayerPrimary Protection DutyWhen to Specify
SiHF-P / SiHF/GLS-P (this page)Exposed galvanized steel wire braid (GSWB)Mechanical crush, slag splash, swarf & rodent defenceExposed steelworks, foundry, glass-furnace & kiln trays at -60 to +180 °C
SiHFC / SiHF-C-SiTinned copper braid (~85%) + outer silicone sheathHigh-frequency EMC / EMI signal & VFD screeningThermocouple extensions, encoder/sensor buses & inverter leads in hot zones
SiHF / SiHF-JNone (smooth brick-red silicone sheath)Maximum flexibility (5x OD fixed) without mechanical loadProtected conduit runs, luminaire drops & enclosed oven cabinets
SIMH FE180 PH120None (orange FR silicone + ceramifiable core)180-min fire circuit integrity (IEC 60331 / EN 50200 PH120)Emergency life-safety alarms, smoke extractors & tunnel fire circuits

Note: Galvanized steel wire braid (GSWB) on SiHF-P is a mechanical armour, not a low-impedance high-frequency EMC shield; specify tinned-copper-braided SiHFC / SiHF-C-Si for EMC-critical instrument circuits.

SiHF-P Armoured Silicone Cable RFQ Specification Checklist

  • Core count and conductor cross-section (e.g., 3G1.5, 4G2.5, 12G1.5, 24G1.5 or 4G16 mm²; specify `G` with green-yellow earth or `X` without earth).
  • Bedding barrier preference: standard glass-tape bedding (`SiHF-P / SiHF-GL-P`) vs full woven glass-fibre braid under GSWB (`SiHF/GLS-P`), or optional transparent/silicone outer oversheath over GSWB.
  • Operating ambient temperature profile (-60 °C to +180 °C), radiant heat exposure, and brass armour-clamping cable gland thread size.
  • Total project meterage and individual drum cut lengths (50 m MOQ; 500 m or 1,000 m wooden export drums standard).
  • Required routine factory test reports (2,000 V AC dielectric test, 20 °C DC conductor resistance, GSWB coverage check) and target delivery window (7 to 45 working days).

Related selection resources

SiHF-P & SiHF/GLS-P GSWB Silicone Cable FAQ

What does the designation SiHF-P / SiHF-GL-P / SiHF/GLS-P stand for?

Silicone-insulated (`Si`), fine-stranded (`HF`), glass-fibre barrier (`GL`/`GLS`) and galvanized steel wire braid armoured (`P`, Panzergeflecht) multicore cable rated 300/500 V and -60 °C to +180 °C.

Can the galvanized steel wire braid (GSWB) on SiHF-P replace a tinned copper EMC shield?

No. Steel wire braid provides magnetic/mechanical armouring against impacts, hot metal chips and rodents, but its higher RF transfer impedance cannot match an 85% tinned copper braid; specify SiHFC or SiHF-C-Si for VFD and analogue sensor EMC shielding.

Does SiHF-P have an outer plastic or silicone jacket over the steel braid?

No on standard SiHF-P / SiHF/GLS-P: the galvanized steel wire braid sits on the outside so it can absorb direct abrasion, slag splatter and clamping inside armour-earthing brass glands. An optional outer silicone oversheath (SiHF-P-Si) can be extruded to custom order.

What is the minimum bending radius for GSWB armoured SiHF-P cable?

10x overall cable diameter (`10 × OD`) for fixed routing and 15x overall diameter (`15 × OD`) for occasional flexing without tensile load. Avoid continuous drag-chain or high-speed reeling duty.

What are the minimum order quantity and delivery lead time for SiHF-P cable?

50 m minimum order quantity per cross-section, supplied on export-fumigated wooden reels with a production lead time of 7 to 45 working days depending on core count and GSWB schedule.

Specifications

SiHF-P / SiHF/GLS-P 300/500 V Dimensional & Current Schedule

SiHF-P Key Voltage, Temperature, GSWB & Bend Radius Summary

  • External GSWB mechanical armour: Close-woven galvanized steel wire braid over a glass-fibre thermal tape protects soft silicone elastomer from metal swarf, slag splatter, impact and rodent damage
  • Extreme thermal envelope: -60 °C to +180 °C continuous conductor rating (+200 °C short-term peak) with zero plasticizer embrittlement in steelworks, foundries and glass furnaces
  • Class 5 tinned copper cores: Fine-stranded tin-plated copper per IEC 60228 Class 5 resists conductor oxidation at 180 °C and simplifies crimping into high-temperature ferrules
  • Halogen-free fire behaviour: Flame-retardant per IEC 60332-1-2 and halogen-free / low-corrosivity per IEC 60754-1 & IEC 60754-2, forming insulating SiO2 ash under flame
  • Full control & feeder range: 2x0.75 mm² up to 24G1.5 mm² numbered control cables and 4G35 mm² furnace feeders; 50 m MOQ, 7 to 45 working days factory lead time
SiHF-P & SiHF/GLS-P GSWB Armoured Silicone Cable (300/500 V, 180 °C) technical data
ParameterValue
Rated voltage300/500 V AC nominal (Uo/U) with 2000 V AC 50 Hz factory spark and dielectric test voltage
Conductor and core rangeIEC 60228 Class 5 tinned copper in 2 to 24 cores from 0.75 mm2 to 35 mm2 (colour-coded up to 5G, numbered 6G to 24G)
Insulation and armouringHalogen-free silicone core insulation, brick-red silicone inner sheath, glass-fibre barrier and outer galvanized steel wire braid (GSWB)
Temperature range and bend radius-60 C to +180 C continuous (+200 C short-term peak); minimum bend radius 10x OD fixed installation and 15x OD occasional flexing
Minimum order and lead time50 m minimum order quantity in custom drum lengths with 7 to 45 working days manufacturing lead time
Fire and halogen performanceFlame-retardant to IEC 60332-1-2 (VDE 0482-332-1-2) and halogen-free / non-corrosive combustion gases to IEC 60754-1 and IEC 60754-2
Electrical parametersMinimum insulation resistance 2000 MOhm*km at 20 C; nominal operating capacitance approx. 52 nF/km

SiHF-P / SiHF-GL-P / SiHF/GLS-P Armoured Dimensional & Electrical Schedule

SiHF-P / SiHF-GL-P / SiHF/GLS-P (300/500 V, 180 °C) — Core Size, Resistance, 30 °C Current, OD over GSWB & Weight Schedule
Model & Core Size (mm²)Max. DC Resistance at 20 °C (Ω/km)Ref. Current at 30 °C Air (A)Approx. OD over GSWB (mm)Copper Index (kg/km)Approx. Cable Weight (kg/km)Next step
SiHF-P 2x0.7526.7127.5 – 7.914.484 – 94Request this size
SiHF-P 3G0.7526.7127.9 – 8.321.695 – 108Request this size
SiHF-P 4G0.7526.7128.6 – 9.329.0116 – 125Request this size
SiHF-P 5G0.7526.7129.7 – 10.136.0140 – 157Request this size
SiHF-P 7G0.7526.7910.2 – 10.750.4176 – 177Request this size
SiHF-P 3G120.0158.2 – 8.928.8110 – 115Request this size
SiHF-P 4G120.0159.0 – 9.438.4142 – 146Request this size
SiHF-P 5G120.0159.8 – 10.448.0155 – 173Request this size
SiHF-P 2x1.513.7188.8 – 9.128.8119 – 126Request this size
SiHF-P 3G1.513.7189.2 – 9.543.2137 – 154Request this size
SiHF-P 4G1.513.7189.9 – 10.357.6170 – 180Request this size
SiHF-P 5G1.513.71810.8 – 11.172.0193 – 209Request this size
SiHF-P 7G1.513.71311.6 – 12.1100.8198 – 259Request this size
SiHF-P 12G1.513.71015.1 – 15.5172.8328 – 457Request this size
SiHF-P 18G1.513.7918.5 – 18.7259.2440 – 646Request this size
SiHF-P 24G1.513.7821.3 – 21.5345.6600 – 855Request this size
SiHF-P 3G2.58.212610.9 – 11.272.0194 – 214Request this size
SiHF-P 4G2.58.212611.8 – 12.196.0263 – 278Request this size
SiHF-P 5G2.58.212612.8 – 13.3120.0304 – 317Request this size
SiHF-P 4G45.093413.8 – 14.2153.6369 – 385Request this size
SiHF-P 4G63.394415.8 – 16.4230.4525 – 545Request this size
SiHF-P 4G101.956120.8384.0845Request this size
SiHF-P 4G161.248222.7614.41,171Request this size
SiHF-P 4G250.79510827.9960.01,785Request this size
SiHF-P 4G350.56513530.41,344.02,310Request this size

Reference ampacity values at 30 °C free air apply DIN VDE 0298-4 thermal derating above +150 °C ambient (for example, 0.75 factor at +155 °C, 0.50 factor at +170 °C and 0.35 factor at +175 °C for 180 °C silicone elastomer).

Outer diameter and finished cable mass vary slightly between standard glass-tape bedding (SiHF-P) and heavy woven glass-braid bedding (SiHF/GLS-P); exact armour wire diameter and gland clamping OD are confirmed on the quotation drawing.

Ensure adequate air ventilation where operating temperatures exceed +100 °C continuously, as hermetically sealed steam/oil atmospheres accelerate silicone hydrolysis.

ASCII part references for BOM and ERP entry: TF-SIHFP-3G1.5; TF-SIHFP-4G1.5; TF-SIHFP-5G1.5; TF-SIHFP-7G1.5; TF-SIHFP-12G1.5; TF-SIHFP-24G1.5; TF-SIHFP-4G2.5; TF-SIHFP-4G4; TF-SIHFP-4G6; TF-SIHFP-4G16; TF-SIHFP-4G35.

Standards

SiHF-P DIN VDE 0250, IEC 60228 & IEC 60754 Standards

SiHF-P & SiHF/GLS-P GSWB Armoured Silicone Cable (300/500 V, 180 °C) standards and test references
Standard or specificationApplication
DIN VDE 0250 / EN 50525-2-83 (Silicone Compound & Construction Reference)Design guideline for 300/500 V cross-linked heat-resistant silicone rubber core insulation and inner bedding operating up to +180 °C continuous.
IEC 60228 / DIN VDE 0295 Class 5 (Flexible Tinned Copper Conductors)Governs strand diameter and maximum 20 °C DC conductor resistance across 0.75 mm² through 35 mm² tinned copper cores.
IEC 60332-1-2 & IEC 60754-1 / IEC 60754-2 (Flame & Halogen-Free Verification)Single-cable vertical flame propagation test and zero-halogen / low-acid-gas emission verification for enclosed industrial plants.
DIN VDE 0293-308 / HD 308 S2 (Core Identification)Colour coding up to 5 cores and white-numbered black cores with green-yellow protective conductor (`G`) from 6 to 24 cores.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and routine factory inspection records

IEC 60754-1 — Halogen acid gas determination for halogen-free silicone compounds

DIN VDE 0250 / EN 50525-2-83 — Heat-resistant silicone rubber insulated flexible cables

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.