SiHF-P & SiHF/GLS-P GSWB Armoured Silicone Cable (300/500 V, 180 °C)
TEBAOFLEX SiHF-P (also specified as SiHF-GL-P and SiHF/GLS-P) is a 300/500 V mechanically armoured high-temperature multicore cable pairing IEC 60228 Class 5 tinned copper conductors (2×0.75 mm² to 4G35 mm² and up to 24G1.5 mm²), halogen-free silicone core insulation and inner sheath, a glass-fibre barrier layer, and an external galvanized steel wire braid (GSWB) for -60 °C to +180 °C (+200 °C peak) hot-zone duty.
TEBAOFLEX SiHF-P (cross-referenced on European steelplant drawings as SiHF-GL-P and SiHF/GLS-P) is a 300/500 V (2,000 V AC test) armoured multicore power and control cable engineered with IEC 60228 Class 5 tinned copper conductors, cross-linked silicone rubber core insulation and brick-red inner bedding, a woven glass-fibre thermal barrier, and an exposed galvanized steel wire braid (GSWB) across 7.5 mm to 30.4 mm outer diameter.
Unarmoured SiHF-J silicone jackets stay supple at +180 °C, but hot metal chips, grate edges, foundry slag splash and mechanical abrasion can cut unreinforced silicone during maintenance. Wrapping a glass-fibre tape/braid and a high-tensile galvanized steel wire braid around the brick-red silicone bedding delivers crush, cut-through and rodent protection while maintaining a 10x OD fixed and 15x OD occasional flexing bend radius from -60 °C to +180 °C.
Specify SiHF-P / SiHF/GLS-P for exposed cable trays, kiln damper actuators, furnace lance drives, glass-annealing lehrs and petrochemical heat-tracing junction runs; select EMC copper-braided SiHFC / SiHF-C-Si instead where high-frequency VFD/sensor shielding is the primary requirement, or unarmoured SiHF-J inside protected conduits. Supplied from a 50 m minimum order quantity with a 7 to 45 working days lead time.
Explore the high-temperature wire and cable range for related configurations.
SiHF-P & SiHF/GLS-P GSWB Armoured Silicone Construction
Manufactured in accordance with DIN VDE 0250 / EN 50525-2-83 silicone elastomer guidelines, IEC 60228 Class 5 stranding and galvanized steel wire armouring practices.

| Component | Material and construction |
|---|---|
| 1. Fine-Stranded Tinned Copper Conductors (Class 5) | Electrolytic tin-plated copper wires stranded to IEC 60228 / VDE 0295 Class 5 (0.75 mm² to 35 mm²) to prevent high-temperature copper scaling and preserve low contact resistance. |
| 2. Silicone Rubber Core Insulation & Core Identification | Heat-vulcanized halogen-free silicone rubber (EI2 / 2GI1 grade); colour-coded per DIN VDE 0293-308 (HD 308 S2) up to 5 cores, and black cores with white sequential numbers plus green-yellow earth from 6 cores upward. |
| 3. Extruded Brick-Red Silicone Inner Sheath (Bedding) | Concentric brick-red silicone rubber inner sheath filling core interstices to establish a firm, circular moisture-resistant bedding beneath the armour. |
| 4. Glass-Fibre Thermal Barrier & Galvanized Steel Wire Braid (GSWB) | Lapped/braided E-glass fibre anti-chafe separator overlaid with a corrosion-resistant galvanized steel wire braid (~75%–85% optical coverage) providing mechanical impact, abrasion and rodent defence. |
SiHF-P, SiHF-GL-P & SiHF/GLS-P Code Breakdown
- Si: Heat-resistant halogen-free silicone rubber core insulation and inner bedding (-60 °C to +180 °C)
- HF: Fine-stranded flexible IEC 60228 Class 5 tinned copper conductors for multi-core power/control
- GL / GLS: Woven or lapped glass-fibre thermal and anti-chafe barrier beneath the steel braid
- P: External galvanized steel wire braid (`Panzergeflecht` / GSWB) for cut, impact and rodent protection
- G / X: `G` denotes inclusion of one green-yellow protective earth core (e.g., 4G2.5); `X` omits green-yellow (e.g., 2x1.5)
SiHF-P Steelworks, Foundry & Glass-Furnace Applications
Deploy SiHF-P / SiHF-GL-P / SiHF/GLS-P wherever ambient radiant heat (-60 °C to +180 °C) coincides with mechanical abrasion, metal swarf or exposed tray routing.

- Steelworks continuous-casting runout tables, blast-furnace tuyere instrumentation, ladle preheater blowers and hot-rolling mill auxiliary drives.
- Glass-melting tank regenerators, float-glass annealing lehrs, ceramic tunnel kilns and aluminium extrusion billet heaters.
- Foundry shakeout decks, die-casting cell hydraulic valve manifolds, cement clinker cooler fans and industrial incinerator dampers.
- Cold-storage blast freezers (-60 °C), marine engine-room hot exhaust zones and industrial plant zones requiring halogen-free rodent-resistant cabling.
SiHF-P (GSWB) vs SiHFC (EMC) vs Unarmoured SiHF-J
| Cable Type | Outer Metallic Layer | Primary Protection Duty | When to Specify |
|---|---|---|---|
| SiHF-P / SiHF/GLS-P (this page) | Exposed galvanized steel wire braid (GSWB) | Mechanical crush, slag splash, swarf & rodent defence | Exposed steelworks, foundry, glass-furnace & kiln trays at -60 to +180 °C |
| SiHFC / SiHF-C-Si | Tinned copper braid (~85%) + outer silicone sheath | High-frequency EMC / EMI signal & VFD screening | Thermocouple extensions, encoder/sensor buses & inverter leads in hot zones |
| SiHF / SiHF-J | None (smooth brick-red silicone sheath) | Maximum flexibility (5x OD fixed) without mechanical load | Protected conduit runs, luminaire drops & enclosed oven cabinets |
| SIMH FE180 PH120 | None (orange FR silicone + ceramifiable core) | 180-min fire circuit integrity (IEC 60331 / EN 50200 PH120) | Emergency life-safety alarms, smoke extractors & tunnel fire circuits |
Note: Galvanized steel wire braid (GSWB) on SiHF-P is a mechanical armour, not a low-impedance high-frequency EMC shield; specify tinned-copper-braided SiHFC / SiHF-C-Si for EMC-critical instrument circuits.
SiHF-P Armoured Silicone Cable RFQ Specification Checklist
- Core count and conductor cross-section (e.g., 3G1.5, 4G2.5, 12G1.5, 24G1.5 or 4G16 mm²; specify `G` with green-yellow earth or `X` without earth).
- Bedding barrier preference: standard glass-tape bedding (`SiHF-P / SiHF-GL-P`) vs full woven glass-fibre braid under GSWB (`SiHF/GLS-P`), or optional transparent/silicone outer oversheath over GSWB.
- Operating ambient temperature profile (-60 °C to +180 °C), radiant heat exposure, and brass armour-clamping cable gland thread size.
- Total project meterage and individual drum cut lengths (50 m MOQ; 500 m or 1,000 m wooden export drums standard).
- Required routine factory test reports (2,000 V AC dielectric test, 20 °C DC conductor resistance, GSWB coverage check) and target delivery window (7 to 45 working days).
Related selection resources
- Complete high-temperature silicone, fiberglass and fluoropolymer cable catalog
- Unarmoured SiHF & SiHF-J 300/500 V 180 °C flexible multicore silicone cable
- SiHFC & SiHF-C-Si tinned-copper EMC screened 180 °C silicone control cable
- N2GFAF VDE 0250-502 single-core fiberglass-braided silicone wire
- Engineering guide: Calculating fixed vs flexing bend radius on braided cables
SiHF-P & SiHF/GLS-P GSWB Silicone Cable FAQ
What does the designation SiHF-P / SiHF-GL-P / SiHF/GLS-P stand for?
Silicone-insulated (`Si`), fine-stranded (`HF`), glass-fibre barrier (`GL`/`GLS`) and galvanized steel wire braid armoured (`P`, Panzergeflecht) multicore cable rated 300/500 V and -60 °C to +180 °C.
Can the galvanized steel wire braid (GSWB) on SiHF-P replace a tinned copper EMC shield?
No. Steel wire braid provides magnetic/mechanical armouring against impacts, hot metal chips and rodents, but its higher RF transfer impedance cannot match an 85% tinned copper braid; specify SiHFC or SiHF-C-Si for VFD and analogue sensor EMC shielding.
Does SiHF-P have an outer plastic or silicone jacket over the steel braid?
No on standard SiHF-P / SiHF/GLS-P: the galvanized steel wire braid sits on the outside so it can absorb direct abrasion, slag splatter and clamping inside armour-earthing brass glands. An optional outer silicone oversheath (SiHF-P-Si) can be extruded to custom order.
What is the minimum bending radius for GSWB armoured SiHF-P cable?
10x overall cable diameter (`10 × OD`) for fixed routing and 15x overall diameter (`15 × OD`) for occasional flexing without tensile load. Avoid continuous drag-chain or high-speed reeling duty.
What are the minimum order quantity and delivery lead time for SiHF-P cable?
50 m minimum order quantity per cross-section, supplied on export-fumigated wooden reels with a production lead time of 7 to 45 working days depending on core count and GSWB schedule.
SiHF-P / SiHF/GLS-P 300/500 V Dimensional & Current Schedule
SiHF-P Key Voltage, Temperature, GSWB & Bend Radius Summary
- External GSWB mechanical armour: Close-woven galvanized steel wire braid over a glass-fibre thermal tape protects soft silicone elastomer from metal swarf, slag splatter, impact and rodent damage
- Extreme thermal envelope: -60 °C to +180 °C continuous conductor rating (+200 °C short-term peak) with zero plasticizer embrittlement in steelworks, foundries and glass furnaces
- Class 5 tinned copper cores: Fine-stranded tin-plated copper per IEC 60228 Class 5 resists conductor oxidation at 180 °C and simplifies crimping into high-temperature ferrules
- Halogen-free fire behaviour: Flame-retardant per IEC 60332-1-2 and halogen-free / low-corrosivity per IEC 60754-1 & IEC 60754-2, forming insulating SiO2 ash under flame
- Full control & feeder range: 2x0.75 mm² up to 24G1.5 mm² numbered control cables and 4G35 mm² furnace feeders; 50 m MOQ, 7 to 45 working days factory lead time
| Parameter | Value |
|---|---|
| Rated voltage | 300/500 V AC nominal (Uo/U) with 2000 V AC 50 Hz factory spark and dielectric test voltage |
| Conductor and core range | IEC 60228 Class 5 tinned copper in 2 to 24 cores from 0.75 mm2 to 35 mm2 (colour-coded up to 5G, numbered 6G to 24G) |
| Insulation and armouring | Halogen-free silicone core insulation, brick-red silicone inner sheath, glass-fibre barrier and outer galvanized steel wire braid (GSWB) |
| Temperature range and bend radius | -60 C to +180 C continuous (+200 C short-term peak); minimum bend radius 10x OD fixed installation and 15x OD occasional flexing |
| Minimum order and lead time | 50 m minimum order quantity in custom drum lengths with 7 to 45 working days manufacturing lead time |
| Fire and halogen performance | Flame-retardant to IEC 60332-1-2 (VDE 0482-332-1-2) and halogen-free / non-corrosive combustion gases to IEC 60754-1 and IEC 60754-2 |
| Electrical parameters | Minimum insulation resistance 2000 MOhm*km at 20 C; nominal operating capacitance approx. 52 nF/km |
SiHF-P / SiHF-GL-P / SiHF/GLS-P Armoured Dimensional & Electrical Schedule
| Model & Core Size (mm²) | Max. DC Resistance at 20 °C (Ω/km) | Ref. Current at 30 °C Air (A) | Approx. OD over GSWB (mm) | Copper Index (kg/km) | Approx. Cable Weight (kg/km) | Next step |
|---|---|---|---|---|---|---|
| SiHF-P 2x0.75 | 26.7 | 12 | 7.5 – 7.9 | 14.4 | 84 – 94 | Request this size |
| SiHF-P 3G0.75 | 26.7 | 12 | 7.9 – 8.3 | 21.6 | 95 – 108 | Request this size |
| SiHF-P 4G0.75 | 26.7 | 12 | 8.6 – 9.3 | 29.0 | 116 – 125 | Request this size |
| SiHF-P 5G0.75 | 26.7 | 12 | 9.7 – 10.1 | 36.0 | 140 – 157 | Request this size |
| SiHF-P 7G0.75 | 26.7 | 9 | 10.2 – 10.7 | 50.4 | 176 – 177 | Request this size |
| SiHF-P 3G1 | 20.0 | 15 | 8.2 – 8.9 | 28.8 | 110 – 115 | Request this size |
| SiHF-P 4G1 | 20.0 | 15 | 9.0 – 9.4 | 38.4 | 142 – 146 | Request this size |
| SiHF-P 5G1 | 20.0 | 15 | 9.8 – 10.4 | 48.0 | 155 – 173 | Request this size |
| SiHF-P 2x1.5 | 13.7 | 18 | 8.8 – 9.1 | 28.8 | 119 – 126 | Request this size |
| SiHF-P 3G1.5 | 13.7 | 18 | 9.2 – 9.5 | 43.2 | 137 – 154 | Request this size |
| SiHF-P 4G1.5 | 13.7 | 18 | 9.9 – 10.3 | 57.6 | 170 – 180 | Request this size |
| SiHF-P 5G1.5 | 13.7 | 18 | 10.8 – 11.1 | 72.0 | 193 – 209 | Request this size |
| SiHF-P 7G1.5 | 13.7 | 13 | 11.6 – 12.1 | 100.8 | 198 – 259 | Request this size |
| SiHF-P 12G1.5 | 13.7 | 10 | 15.1 – 15.5 | 172.8 | 328 – 457 | Request this size |
| SiHF-P 18G1.5 | 13.7 | 9 | 18.5 – 18.7 | 259.2 | 440 – 646 | Request this size |
| SiHF-P 24G1.5 | 13.7 | 8 | 21.3 – 21.5 | 345.6 | 600 – 855 | Request this size |
| SiHF-P 3G2.5 | 8.21 | 26 | 10.9 – 11.2 | 72.0 | 194 – 214 | Request this size |
| SiHF-P 4G2.5 | 8.21 | 26 | 11.8 – 12.1 | 96.0 | 263 – 278 | Request this size |
| SiHF-P 5G2.5 | 8.21 | 26 | 12.8 – 13.3 | 120.0 | 304 – 317 | Request this size |
| SiHF-P 4G4 | 5.09 | 34 | 13.8 – 14.2 | 153.6 | 369 – 385 | Request this size |
| SiHF-P 4G6 | 3.39 | 44 | 15.8 – 16.4 | 230.4 | 525 – 545 | Request this size |
| SiHF-P 4G10 | 1.95 | 61 | 20.8 | 384.0 | 845 | Request this size |
| SiHF-P 4G16 | 1.24 | 82 | 22.7 | 614.4 | 1,171 | Request this size |
| SiHF-P 4G25 | 0.795 | 108 | 27.9 | 960.0 | 1,785 | Request this size |
| SiHF-P 4G35 | 0.565 | 135 | 30.4 | 1,344.0 | 2,310 | Request this size |
Reference ampacity values at 30 °C free air apply DIN VDE 0298-4 thermal derating above +150 °C ambient (for example, 0.75 factor at +155 °C, 0.50 factor at +170 °C and 0.35 factor at +175 °C for 180 °C silicone elastomer).
Outer diameter and finished cable mass vary slightly between standard glass-tape bedding (SiHF-P) and heavy woven glass-braid bedding (SiHF/GLS-P); exact armour wire diameter and gland clamping OD are confirmed on the quotation drawing.
Ensure adequate air ventilation where operating temperatures exceed +100 °C continuously, as hermetically sealed steam/oil atmospheres accelerate silicone hydrolysis.
ASCII part references for BOM and ERP entry: TF-SIHFP-3G1.5; TF-SIHFP-4G1.5; TF-SIHFP-5G1.5; TF-SIHFP-7G1.5; TF-SIHFP-12G1.5; TF-SIHFP-24G1.5; TF-SIHFP-4G2.5; TF-SIHFP-4G4; TF-SIHFP-4G6; TF-SIHFP-4G16; TF-SIHFP-4G35.
SiHF-P DIN VDE 0250, IEC 60228 & IEC 60754 Standards
| Standard or specification | Application |
|---|---|
| DIN VDE 0250 / EN 50525-2-83 (Silicone Compound & Construction Reference) | Design guideline for 300/500 V cross-linked heat-resistant silicone rubber core insulation and inner bedding operating up to +180 °C continuous. |
| IEC 60228 / DIN VDE 0295 Class 5 (Flexible Tinned Copper Conductors) | Governs strand diameter and maximum 20 °C DC conductor resistance across 0.75 mm² through 35 mm² tinned copper cores. |
| IEC 60332-1-2 & IEC 60754-1 / IEC 60754-2 (Flame & Halogen-Free Verification) | Single-cable vertical flame propagation test and zero-halogen / low-acid-gas emission verification for enclosed industrial plants. |
| DIN VDE 0293-308 / HD 308 S2 (Core Identification) | Colour coding up to 5 cores and white-numbered black cores with green-yellow protective conductor (`G`) from 6 to 24 cores. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and routine factory inspection records
IEC 60754-1 — Halogen acid gas determination for halogen-free silicone compounds
DIN VDE 0250 / EN 50525-2-83 — Heat-resistant silicone rubber insulated flexible cables
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
FEP/PFA-GSWB & PFA-SSWB 0.6/1 kV Steel-Braided High-Temp Power Cable (200–260 °C)
A related cable option for a different application or duty profile.
View productKFF, KFFP, KFFRP, KFFP2-22 & DJFPFP 450/750 V Fluoroplastic Control & Computer Cable
A related cable option for a different application or duty profile.
View productSiHF & SiHF-J Multi-Core Flexible Silicone Cable (300/500 V, 180 °C)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.