SiF Single-Core Flexible Silicone Wire & Power Lead (300/500 V, 180 °C)
TEBAOFLEX SiF is a 300/500 V (2,000 V AC test) halogen-free single-core flexible silicone wire and furnace power lead pairing IEC 60228 Class 5 tinned copper conductors (0.25 mm² fine hook-up gauges right through 240 mm² heavy busbar feeders) with extruded -60 °C to +180 °C (+200 °C short-term peak) cross-linked silicone rubber insulation.
TEBAOFLEX SiF (manufactured to DIN VDE 0250-502 / EN 50525-2-41 H05S-K construction geometry) is a 300/500 V (2,000 V AC test) single-core flexible conductor insulated with halogen-free heat-vulcanized silicone rubber over IEC 60228 Class 5 tinned copper across 19 standard metric cross-sections from 0.25 mm² (1.9 mm OD, 7 kg/km) up to 240 mm² (25.6 mm OD, 2,540 kg/km).
Inside high-temperature switchgear, commercial ovens, LED floodlight housings, traction resistor banks and metallurgical furnace terminal boxes, PVC H05V-K/H07V-K single cores embrittle above +70 °C while bare copper strands oxidize above +120 °C. Pairing tin-plated Class 5 copper with pure cross-linked silicone elastomer maintains supple 4x–6x OD fixed routing flexibility from -60 °C to +180 °C (+200 °C short-term peak) without shed glass particulates.
Choose SiF for protected internal cabinet, luminaire, heating-bank and busbar jumper runs; switch to extra-flexible Class 6 `SiFF` for dense hinged panel doors, solid Class 1 `SiD` for push-in PCB/luminaire blocks, glass-braided `H05SJ-K (SiF/GL)` where wires rub metal edges, or `N2GFAF` for 500 V VDE 0250-502 thicker-wall braided duty. Fine sizes (0.25–2.5 mm²) ship on 300 m / 500 m spools per colour, while heavy leads (4–240 mm²) carry a 50 m MOQ, with a 7 to 45 working days lead time.
Explore the high-temperature wire and cable range for related configurations.
SiF 180 °C Single-Core Class 5 Silicone Wire Construction
Extruded as a clean single-layer silicone elastomer core over tin-plated Class 5 copper per DIN VDE 0250 and IEC 60228.

| Component | Material and construction |
|---|---|
| 1. Fine-Stranded Tinned Copper Conductor (IEC 60228 Class 5) | Annealed tin-plated copper wires stranded to IEC 60228 / DIN VDE 0295 Class 5 across 0.25 mm² to 240 mm² (bare copper `SiF-BC` or nickel-plated copper for >200 °C available to order). |
| 2. Extruded Silicone Rubber Insulation (EI2 / 2GI1) | Smooth, braidless cross-linked silicone rubber wall (0.6 mm nominal wall on 0.25–1.0 mm² climbing to 2.4 mm on 240 mm²) formulated for -60 °C to +180 °C continuous service. |
| 3. 12-Colour Identification Range | Stocked pigment formulations in brick-red (red-brown), black, blue, brown, white, red, grey, yellow, green, violet, orange, transparent and dual-extruded green-yellow earth. |
SiF, SiF-BC & H05S-K Designation Breakdown
- Si: Heat-resistant halogen-free cross-linked silicone rubber insulation (-60 °C to +180 °C, +200 °C peak)
- F: Fine-stranded flexible conductor per IEC 60228 / DIN VDE 0295 Class 5 (tinned copper standard)
- 1x (0.25–240): Single-core unbraided hook-up wire (`0.25–2.5 mm²`) or single-core cabinet/furnace power lead (`4–240 mm²`)
- H05S-K: Harmonized EN 50525-2-41 300/500 V 180 °C single-core silicone reference covering 0.5 to 2.5 mm²
SiF Oven, Luminaire, Switchgear & Furnace Busbar Applications
Deploy SiF single-core flexible wires inside protected enclosures, conduits, luminaires and high-temperature power distribution cabinets without continuous mechanical abrasion.

- Internal wiring of commercial baking ovens, catering warmers, laboratory furnaces, autoclaves, sauna controllers and HVAC electric duct heaters (0.25 to 6 mm²).
- High-intensity industrial luminaires, UV curing lamps, infrared drying tunnels and stage/studio spotlight housings.
- Switchgear cubicles, metallurgical transformer secondary jumpers, braking resistor banks, generator terminal boxes and DC busbar risers (10 to 240 mm²).
- Plastics extruder heater-band jumpers and -60 °C cryogenic refrigeration control panels.
SiF vs Class 6 SiFF / Solid SiD vs Braided H05SJ-K & UL 3139
| Single-Core Silicone Model | Stranding & Outer Layer | Voltage & Temp Rating | When to Specify |
|---|---|---|---|
| SiF (this page) | Class 5 tinned Cu + smooth braidless silicone | 300/500 V, -60 to +180 °C | Standard metric cabinet hook-up (0.25–2.5 mm²) & heavy furnace busbars (4–240 mm²) |
| SiFF / SiD / SiZ | Class 6 extra-fine (`SiFF`), Class 1 solid (`SiD`) or twin (`SiZ`) | 300/500 V, -60 to +180 °C | Tight hinged cabinet doors (`SiFF`), push-in blocks (`SiD`) or 2-wire sensors (`SiZ`) |
| H05SJ-K (SiF/GL) & N2GFAF | Class 5 tinned Cu + silicone + outer fiberglass braid | 300/500 V (`H05SJ-K`) / 500 V (`N2GFAF`), 180 °C | Abrasive sheet-metal knockouts, heater element studs & hot motor boxes |
| UL 3139 & UL 3367 (AWG) | Solid/stranded tinned Cu + 45-mil or 15-mil braidless silicone | 600 V (`Style 3139`) / 300 V (`Style 3367`), 200 °C | North American OEM equipment specifying AWG gauges and 200 °C UL 758 wall profiles |
Select braidless SiF inside clean enclosures and automated wire-stripping machines; choose fiberglass-braided H05SJ-K (SiF/GL) or N2GFAF if single cores rub against metal edges.
SiF Single-Core Silicone Wire (0.25–240 mm²) RFQ Checklist
- Conductor cross-section in mm² (0.25 mm² to 240 mm²) and conductor finish (standard Class 5 tinned copper vs bare copper `SiF-BC`).
- Insulation colour breakdown and quantity per colour (300 m / 500 m standard spools on 0.25–2.5 mm²; 50 m minimum cut/drum length on 4–240 mm²).
- Operating voltage (up to 300/500 V AC; advise if 1.1 kV or 3.3 kV thick-wall SiF-HV silicone wall is needed) and ambient temperature peak.
- Termination method (automated rotary stripping, ultrasonic welding or heavy compression lugs on 35–240 mm²).
- Required batch inspection documents (2,000 V AC spark/dielectric test, 20 °C DC conductor resistance, halogen-free certificate) and target shipment date (7 to 45 working days).
Related selection resources
- High-temperature silicone, fiberglass and fluoropolymer wire catalog
- SiFF (Class 6), SiD (Class 1 solid) & SiZ twin silicone hook-up wires
- H05SJ-K & SiF/GL fiberglass-braided 180 °C single-core silicone wire
- N2GFAF VDE 0250-502 500 V fiberglass-braided silicone single-core cable
- Engineering guide: Silicone 180 °C vs PTFE 260 °C vs Mica 450 °C insulation limits
SiF 180 °C Single-Core Silicone Wire FAQ
What is the difference between SiF, SiFF, SiD and SiF/GL silicone wire?
Class 5 vs Class 6 vs Class 1 conductor stranding and outer fiberglass braiding. `SiF` uses IEC 60228 Class 5 flexible tinned copper without a braid; `SiFF` upgrades to ultra-fine Class 6 stranding; `SiD` uses a Class 1 solid conductor; and `SiF/GL` (`H05SJ-K`) adds a protective glass-fibre braid over `SiF`.
What is the minimum order quantity for fine SiF hook-up sizes versus heavy SiF power cables?
300 m or 500 m standard factory spools per colour on fine 0.25 mm² to 2.5 mm² hook-up sizes, and 50 m cut-length MOQ on 4 mm² to 240 mm² single-core power leads, with a 7 to 45 working days lead time.
Can SiF single-core silicone wire operate at +200 °C?
Short-term peaks up to +200 °C are permitted on DIN/VDE SiF compounds, while continuous conductor rating is -60 °C to +180 °C. For continuous +200 °C AWG equipment specs, select wires engineered to UL 3139 / UL 3367 (braidless) or UL 3513 / SF-2 (braided); above +200 °C, select PTFE/PFA (250–260 °C) or mica-glass MGT (450 °C).
Why is tinned copper standard on TEBAOFLEX SiF up to 240 mm²?
Tin plating prevents rapid copper oxide scaling between +120 °C and +180 °C, keeping lug and ferrule contact resistance stable over years of thermal cycling.
Can SiF single-core wires be laid directly on exposed cable trays without conduit?
No. SiF is a single-core insulated equipment/cabinet wire (300/500 V) without a mechanical outer sheath; route it inside enclosures, conduits or trunking, or specify multi-core sheathed SiHF-J / armoured SiHF-P for external tray runs.
SiF 300/500 V (0.25 mm² to 240 mm²) Dimensional & Current Schedule
SiF Key Voltage, Stranding, Spool/Drum MOQ & Temperature Summary
- Full 0.25 mm² to 240 mm² span: Covers 0.25–2.5 mm² control/appliance hook-up wires (1.9 to 3.4 mm OD) and 4–240 mm² single-core furnace/motor power leads (up to 25.6 mm OD)
- Class 5 tinned copper core: Electrolytic tin-plated fine copper strands per IEC 60228 Class 5 resist high-temperature oxidation and green-rot corrosion up to +180 °C
- Clean braidless stripping: Smooth unbraided EI2 silicone elastomer strips cleanly on automated crimping lines without glass-fibre dust (for glass-braided abrasion protection, see SiF/GL)
- Zero-halogen & flame retardant: Complies with IEC 60754-1/2 halogen-free gas tests and IEC 60332-1-2 flame retardance, leaving non-conductive silica ash in fire conditions
- Tiered spool & drum MOQ: 300 m / 500 m standard factory spools per colour on 0.25–2.5 mm² hook-up wires; 50 m cut-length MOQ on 4–240 mm² power leads; 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 300/500 V AC nominal (Uo/U, up to 500 V protected internal cabinet routing) with 2000 V AC test voltage |
| Cross-section and stranding | 0.25 mm2 to 240 mm2 fine-stranded IEC 60228 Class 5 tinned copper single-core conductor |
| Insulation material | Braidless halogen-free cross-linked silicone rubber (EI2 / 2GI1 grade) in 12 standard colours plus green-yellow |
| Temperature range and bend radius | -60 C to +180 C continuous (+200 C short-term peak); minimum fixed bend radius 5x to 6x overall diameter |
| Put-up MOQ and lead time | 300 m or 500 m standard spools per colour on 0.25 to 2.5 mm2; 50 m cut-length MOQ on 4 to 240 mm2 power leads; 7 to 45 working days |
| Fire and halogen tests | Flame-retardant per IEC 60332-1-2 and halogen-free / non-corrosive per IEC 60754-1 and IEC 60754-2; min. 200 MOhm*km insulation resistance |
| Harmonized cross-reference | Corresponds to DIN VDE 0250 SiF and EN 50525-2-41 H05S-K (0.5 to 2.5 mm2) / H07S-K style metric silicone single cores |
SiF Single-Core 180 °C Silicone Wire (0.25 mm² to 240 mm²) Master Schedule
| Model & Size (mm²) | Max. DC Resistance at 20 °C (Ω/km) | Ref. Current at 30 °C Free Air (A) | Nominal Outer Diameter (mm) | Copper Index (kg/km) | Nominal Weight (kg/km) | Standard Put-Up / MOQ | Next step |
|---|---|---|---|---|---|---|---|
| SiF 1x0.25 | 82.0 | 6 | 1.9 | 2.4 | 7.0 | 500 m spool | Request this size |
| SiF 1x0.5 | 40.1 | 10 | 2.1 | 4.8 | 9.0 | 500 m spool | Request this size |
| SiF 1x0.75 | 26.7 | 15 | 2.4 | 7.2 | 12.0 | 300 m / 500 m spool | Request this size |
| SiF 1x1 | 20.0 | 19 | 2.5 | 9.6 | 14.4 | 300 m / 500 m spool | Request this size |
| SiF 1x1.5 | 13.7 | 24 | 2.8 | 14.4 | 20.0 | 300 m / 500 m spool | Request this size |
| SiF 1x2.5 | 8.21 | 32 | 3.4 | 24.0 | 32.0 | 300 m spool | Request this size |
| SiF 1x4 | 5.09 | 42 | 4.2 | 38.0 | 50.0 | 50 m cut / 100 m coil | Request this size |
| SiF 1x6 | 3.39 | 54 | 5.0 | 58.0 | 73.0 | 50 m cut / 100 m coil | Request this size |
| SiF 1x10 | 1.95 | 73 | 6.6 | 96.0 | 119.0 | 50 m MOQ / drum | Request this size |
| SiF 1x16 | 1.24 | 98 | 7.4 | 154.0 | 177.0 | 50 m MOQ / drum | Request this size |
| SiF 1x25 | 0.795 | 129 | 9.2 | 240.0 | 274.0 | 50 m MOQ / drum | Request this size |
| SiF 1x35 | 0.565 | 158 | 10.3 | 336.0 | 370.0 | 50 m MOQ / drum | Request this size |
| SiF 1x50 | 0.393 | 198 | 12.2 | 480.0 | 526.0 | 50 m MOQ / drum | Request this size |
| SiF 1x70 | 0.277 | 245 | 14.2 | 672.0 | 721.0 | 50 m MOQ / drum | Request this size |
| SiF 1x95 | 0.210 | 292 | 16.6 | 912.0 | 976.0 | 50 m MOQ / drum | Request this size |
| SiF 1x120 | 0.164 | 344 | 18.0 | 1,152.0 | 1,212.0 | 50 m MOQ / drum | Request this size |
| SiF 1x150 | 0.132 | 391 | 20.0 | 1,440.0 | 1,514.0 | 50 m MOQ / drum | Request this size |
| SiF 1x185 | 0.108 | 448 | 22.5 | 1,776.0 | 1,870.0 | 50 m MOQ / drum | Request this size |
| SiF 1x240 | 0.0817 | 528 | 25.6 | 2,304.0 | 2,540.0 | 50 m MOQ / drum | Request this size |
Also available in 0.35 mm² (2.0 mm OD, 7.6 kg/km, 500 m spool) and custom 300 mm² heavy busbar leads, as well as thick-wall 3.3 kV / 6.6 kV single-core HV silicone motor leads on request.
30 °C free-air reference currents require DIN VDE 0298-4 thermal derating when ambient temperatures exceed +145 °C (0.75 at +155 °C, 0.50 at +170 °C, 0.35 at +175 °C) and grouping derating when bundled inside conduits.
Single-core fine sizes (`0.25 mm²` to `2.5 mm²`) are supplied on 300 m or 500 m standard factory spools per colour; medium/heavy power cross-sections (`4 mm²` to `240 mm²`) are supplied from a 50 m cut-length MOQ.
ASCII part references for BOM and ERP entry: TF-SIF-0.5; TF-SIF-0.75; TF-SIF-1.0; TF-SIF-1.5; TF-SIF-2.5; TF-SIF-4; TF-SIF-6; TF-SIF-10; TF-SIF-16; TF-SIF-25; TF-SIF-50; TF-SIF-95; TF-SIF-150; TF-SIF-240.
SiF DIN VDE 0250, EN 50525-2-41 & IEC 60228 Standards
| Standard or specification | Application |
|---|---|
| DIN VDE 0250 & EN 50525-2-41 (Metric Silicone Single-Core Reference) | Construction and elastomer basis for 300/500 V single-core flexible silicone insulated conductors (aligned with H05S-K in 0.5–2.5 mm²). |
| IEC 60228 / DIN VDE 0295 Class 5 (Tinned Copper Stranding) | Specifies fine-wire strand diameter and maximum 20 °C DC resistance for tinned copper conductors from 0.25 mm² through 240 mm². |
| IEC 60332-1-2 & IEC 60754-1 / IEC 60754-2 (Flame & Halogen-Free) | Verifies single-wire vertical flame self-extinguishing performance and zero halogen acid gas evolution. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and routine electrical test records
IEC 60228 — Conductors of insulated cables (Class 5 tinned copper resistance)
DIN VDE 0250 / EN 50525-2-41 — Heat-resistant silicone rubber single-core wires
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
SiFF Class 6 Extra-Flexible, SiD Solid & SiZ Twin Silicone Wire (300/500 V, 180 °C)
A related cable option for a different application or duty profile.
View productH05SJ-K & SiF/GL Fiberglass-Braided Silicone Wire (300/500 V, 180 °C)
A related cable option for a different application or duty profile.
View productN2GFAF & (N)2GFAF Silicone Single-Core Wire (DIN VDE 0250-502, 300/300 V)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.