Type 240 Underground Coal Mine Cable 1.1kV to 11kV
Type 240 Underground Coal Mine Cable 1.1kV to 11kV is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. The supplied cross-section and cutaway illustrate three screened phase conductors together with three smaller pilot conductors. The visible braid belongs to the phase-core screen; it is not a substitute for verifying the intended earthing and bonding arrangement at the equipment termination. The following selection table reproduces the supplied nominal dimensions. Send the exact size, length, installation duty and documentation requirements for a technical quotation.
Type 240 Underground Coal Mine Cable 1.1kV to 11kV is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. The supplied cross-section and cutaway illustrate three screened phase conductors together with three smaller pilot conductors. The visible braid belongs to the phase-core screen; it is not a substitute for verifying the intended earthing and bonding arrangement at the equipment termination. The following selection table reproduces the supplied nominal dimensions. It is an ordering aid; confirm the final cable schedule and any full electrical data required for the project before release. Manual review: the supplied 240.1 row for 35mm² shows 53.6mm nominal diameter, while the following 50mm² row shows 48.4mm. This may be a source-table anomaly; confirm the 35mm² outer diameter before production or replacement ordering. The stated application is general use in underground coal mines, excluding shuttle cars. The supplied reference also identifies use in underground mine environments where explosive gases and dust may accumulate. This application statement does not by itself confirm hazardous-area approval, so the mine’s electrical and safety requirements must be checked for every installation. Type 240 underground coal mine cable is a screened 3+3 core mine power cable family for general underground coal-mine service, excluding shuttle-car duty. The source record places this product in mining & tunneling cables. Before ordering, confirm the exact product variant, conductor or core arrangement, system rating, route conditions, equipment connection and required documentation against the project specification.
Type 240 Underground Coal Mine Cable 1.1kV to 11kV construction
Cable Construction
The supplied cross-section and cutaway illustrate three screened phase conductors together with three smaller pilot conductors. The visible braid belongs to the phase-core screen; it is not a substitute for verifying the intended earthing and bonding arrangement at the equipment termination.

- Conductor: flexible stranded tinned copper phase conductors.
- Separator and insulation: semiconductive layers where specified and R-EP-90 insulation.
- Phase-core screen: tinned copper/nylon braid over each phase core.
- Pilot system: three interstitial pilot cores among the phase cores.
- Lay-up and sheath: semiconductive cradle and heavy-duty elastomeric outer sheath.
Type 240 Underground Coal Mine Cable 1.1kV to 11kV applications
Applications
The stated application is general use in underground coal mines, excluding shuttle cars. The supplied reference also identifies use in underground mine environments where explosive gases and dust may accumulate. This application statement does not by itself confirm hazardous-area approval, so the mine’s electrical and safety requirements must be checked for every installation.

Selection Notes for Buyers
- Select Type 240.1, 240.3, 240.6 or 240.11 from the system voltage, then select conductor area from load current and permissible voltage drop.
- Check the nominal outer diameter and mass against cable-route space, supports and handling equipment.
- Confirm the three pilot-core purpose and its termination at both ends before substituting another cable family.
- Do not treat the general underground-mine application as proof of Ex or hazardous-area certification; request the project’s required approval and documentation separately.
- For a replacement, provide the complete sheath marking, voltage type, conductor area, pilot details and a photo of the termination.
Selection checks
Confirm the equipment interface, installation method, route length, movement or flexing duty, environmental exposure, conductor or core requirements and project documentation before final selection.
Type 240 Underground Coal Mine Cable 1.1kV to 11kV specifications
The source-listed technical notes are retained below. Confirm the final size, tolerance, installation basis and ordered configuration before release.
Dimensions and Weight
The following selection table reproduces the supplied nominal dimensions. It is an ordering aid; confirm the final cable schedule and any full electrical data required for the project before release.
Manual review: the supplied 240.1 row for 35mm² shows 53.6mm nominal diameter, while the following 50mm² row shows 48.4mm. This may be a source-table anomaly; confirm the 35mm² outer diameter before production or replacement ordering.
Source-listed technical tables
The tables below retain the original product data, including units, ranges and ordering examples.
| Suitable for | General underground coal-mine power circuits, except shuttle cars, where the supplied Type 240 construction and voltage grade are appropriate. |
|---|---|
| Confirm before use | System voltage, conductor area, route length, voltage drop, pilot function, termination, mechanical duty and site requirements. |
| Not established by supplied data | Minimum bend radius, tensile load, reeling/trailing cycle life, temperature range, oil/water/UV performance and formal hazardous-area approval. |
| Product type | Type 240 underground coal mine cable |
|---|---|
| Core configuration | 3 phase cores + 3 interstitial pilot cores |
| Voltage / test voltage | 240.1: 1.1/1.1kV / 4.2kV; 240.3: 3.3/3.3kV / 12kV; 240.6: 6.6/6.6kV / 22kV; 240.11: 11/11kV / 30kV |
| Conductor | Electrolytic, flexible multi-stranded circular tinned copper wire (rope lay), AS/NZS 1125.2.10 |
| Separator layers | Semiconductive layer for 3.3/3.3kV and above, except pilot cores |
| Insulation | R-EP-90, referenced to AS/NZS 3808 |
| Phase-core screen | Tinned copper / nylon braid |
| Lay-up | Phase cores laid over a semiconductive cradle; phase cores do not contact each other and contact the interstitial pilot cores |
| Outer sheath | Heavy-duty elastomeric outer sheath, referenced to AS/NZS 3808 |
| Standard reference | AS/NZS 1802 |
| Type | Nominal area | Insulation thickness | Nominal cable diameter | Nominal weight |
|---|---|---|---|---|
| 240.1 | 6 / 10 / 16 / 25 / 35 / 50 / 70 / 95 / 120 / 150 / 185 / 240 / 300mm² | 1.5 / 1.5 / 1.6 / 1.6 / 1.6 / 1.7 / 1.8 / 2.0 / 2.1 / 2.3 / 2.5 / 2.8 / 3.0mm | 30.0 / 32.6 / 35.8 / 39.7 / 53.6 / 48.4 / 54.0 / 58.8 / 64.6 / 70.3 / 77.5 / 86.1 / 95.2mm | 131 / 159 / 202 / 265 / 326 / 404 / 533 / 635 / 775 / 940 / 1140 / 1410 / 1775kg/100m |
| 240.3 | 16 / 25 / 35 / 50 / 70 / 95 / 120 / 150 / 185 / 240mm² | 3.0mm | 46.7 / 50.6 / 54.0 / 58.1 / 63.0 / 66.7 / 72.6 / 78.6 / 83.8 / 90.8mm | 306 / 379 / 444 / 525 / 656 / 750 / 910 / 1115 / 1280 / 1540kg/100m |
| 240.6 | 16 / 25 / 35 / 50 / 70 / 95 / 120 / 150 / 185 / 240mm² | 5.0mm | 57.9 / 61.7 / 65.2 / 69.0 / 74.3 / 78.3 / 83.5 / 89.5 / 95.1 / 101.8mm | 440 / 521 / 593 / 685 / 830 / 954 / 1111 / 1335 / 1515 / 1788kg/100m |
| 240.11 | 25 / 35 / 50 / 70 / 95 / 120 / 150mm² | 7.6mm | 76.0 / 80.1 / 84.0 / 89.1 / 94.1 / 99.9 / 104.0mm | 752 / 860 / 961 / 1125 / 1300 / 1470 / 1659kg/100m |
Original product attributes
These product attributes are retained as supplied and should be checked against the ordered construction.
| Product Type | Type 240 underground coal mine cable |
|---|---|
| Model | Type 240.1 / 240.3 / 240.6 / 240.11 |
| Voltage Rating | 1.1/1.1kV; 3.3/3.3kV; 6.6/6.6kV; 11/11kV |
| Test Voltage | 4.2kV; 12kV; 22kV; 30kV |
| Core Configuration | 3 phase cores + 3 interstitial pilot cores |
| Conductor | Flexible multi-stranded tinned copper |
| Insulation | R-EP-90 |
| Phase Core Screen | Tinned copper / nylon braid |
| Outer Sheath | Heavy-duty elastomeric outer sheath |
| Standard Reference | AS/NZS 1802 |
| Application | General underground coal-mine use, excluding shuttle cars |
Type 240 Underground Coal Mine Cable 1.1kV to 11kV standards and compliance
The following standard references are carried over from the original product record. They identify the source basis and do not replace project-specific certification or inspection requirements.
- Conductor Electrolytic, flexible multi-stranded circular tinned copper wire (rope lay), AS/NZS 1125.2.10
- Insulation R-EP-90, referenced to AS/NZS 3808
- Outer sheath Heavy-duty elastomeric outer sheath, referenced to AS/NZS 3808
- Standard reference AS/NZS 1802
Where a project requires a test report, certificate, marking record or inspection release, include that requirement in the quotation request.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Type 241.1 Mining Cable 1.1 kV | Type 241 Family
A related cable option for a different application or duty profile.
View productType MP-GC 15kV Mine Power Feeder Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.