MINING & TUNNELING CABLES TEBAOFLEX

Flat Type G 2C Mining Cable with Ground, 2 kV

Flat Type G 2C cable is a 2 kV mining trailing cable with two power conductors and one shaped grounding conductor.

  • Flexible tinned-copper conductors.
  • EPR insulation with black and white power-core identification.
  • One grounding conductor between the power cores.
  • Textile reinforcement and a black CPE jacket.
  • Sizes: 6, 4, 2, 1, 1/0 and 2/0 AWG.
  • Maximum continuous conductor temperature: 90 °C.
Product information
Brand
TEBAOFLEX
Product overview

Flat Type G 2C cable for DC mining equipment

Flat Type G 2C cable is a 2 kV trailing cable with two power cores and one shaped grounding conductor. Its flat assembly combines flexible tinned-copper conductors, EPR insulation, synthetic-yarn reinforcement and a black CPE jacket.

This arrangement serves two-conductor DC circuits on off-track mining equipment, including shuttle cars, drills, cutters and loading machines. The grounding conductor lies between the two insulated power cores. The separate power and protective-ground functions are visible in the construction diagram and in the size-specific conductor schedule.

  • Circuit selection: match the two power conductors and grounding-conductor size to the equipment drawing.
  • Size selection: compare six AWG options together, from 6 AWG to 2/0 AWG.
  • Route clearance: use both cable height and width when checking guides, equipment entries and termination space.
  • Thermal selection: the ampacity table states continuous-duty values at 90 °C conductor temperature and 40 °C ambient.

This Type G construction has one grounding conductor and no separate ground-check core. Browse the mining cable range for other conductor arrangements, or read the grounding and ground-check cable comparison when selecting the protection-circuit configuration.

Construction

Two power conductors and one shaped ground

The flat assembly places one flexible grounding conductor between two EPR-insulated power cores. Synthetic yarn reinforces the assembly beneath the CPE outer jacket.

Flat Type G 2C cross-section: two power cores and one grounding conductor
Flat Type G 2C cross-section: two power cores and one grounding conductor.
Flat Type G 2C construction
ElementConstruction
Power conductorsTwo flexible tinned-copper conductors
InsulationEPR
Power-core identificationBlack and white
Grounding conductorOne shaped flexible tinned-copper conductor between the power cores
ReinforcementSynthetic textile yarn
Outer jacketBlack heavy-duty CPE
Ground-check coreNone
Applications

DC mining-equipment trailing connections

Flat Type G 2C serves two-conductor DC power circuits on off-track mining machinery.

Trailing-cable connection to underground DC mining equipment
Trailing-cable connection to underground DC mining equipment.
  • Shuttle cars: flat trailing leads with a separate protective-ground conductor.
  • Drilling and cutting equipment: two-power-conductor DC connections matched to the machine circuit.
  • Loading equipment: flexible cable connections between the supply and mobile machine.

Grounding and monitoring

This construction contains one grounding conductor and no separate ground-check core. For a monitored circuit, compare the Type G-GC cable with ground-check conductor.

Flat-cable routing

Use the finished height and width to check guide clearance and cable orientation. Maintain the intended bending plane and avoid twisting the flat assembly. Current-rating selection uses the installation method and the thermal conditions stated in Specifications.

Specifications

Flat Type G 2C sizes and specifications

Flat Type G 2C rating and circuit summary
ParameterValue
Rated voltage2 kV
Power / ground arrangement2 power conductors + 1 grounding conductor
Maximum continuous conductor temperature90 °C
Ampacity ambient temperature40 °C
Nominal sizes shown6, 4, 2, 1, 1/0 and 2/0 AWG
Power and grounding conductor schedule
ConfigurationWires per power conductorGround size (AWG)Ground wiresEPR thickness (mil / mm)
Flat Type G 2C × 6 AWG133 (7 × 19)8270 (6 × 45)60 / 1.524
Flat Type G 2C × 4 AWG259 (7 × 37)7180 (6 × 30)60 / 1.524
Flat Type G 2C × 2 AWG259 (7 × 37)5168 (6 × 28)60 / 1.524
Flat Type G 2C × 1 AWG259 (7 × 37)4168 (6 × 28)80 / 2.032
Flat Type G 2C × 1/0 AWG259 (7 × 37)3204 (6 × 34)80 / 2.032
Flat Type G 2C × 2/0 AWG329 (7 × 47)2246 (6 × 41)80 / 2.032
Nominal flat-cable dimensions, mass and ampacity
ConfigurationHeight × width (in)Height × width (mm)Mass (lb/1000 ft)Mass (kg/km)Ampacity (A)
Flat Type G 2C × 6 AWG0.56 × 1.0214.22 × 25.9150074495
Flat Type G 2C × 4 AWG0.61 × 1.1515.49 × 29.21660982127
Flat Type G 2C × 2 AWG0.73 × 1.3518.54 × 34.299901473167
Flat Type G 2C × 1 AWG0.81 × 1.5520.57 × 39.3712301830191
Flat Type G 2C × 1/0 AWG0.93 × 1.6723.62 × 42.4215402292217
Flat Type G 2C × 2/0 AWG0.99 × 1.8525.15 × 46.9918702783250

Ampacity is based on continuous duty at 90 °C conductor temperature and 40 °C ambient. Apply installation and grouping correction factors for the circuit. Dimensions and mass are nominal; metric figures are rounded conversions of the inch and lb/1000 ft values.

Standards

Flat Type G construction standards

The mining-cable design reference is ICEA S-75-381 / NEMA WC 58 — portable and mining power-feeder cables.

  • ASTM B172: rope-lay-stranded copper conductors.
  • ASTM B33: tinned soft or annealed copper wire.
  • Rated voltage: 2 kV.
  • Core arrangement: two power conductors and one grounding conductor.
Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.