High Temperature Cables TEBAOFLEX

ECS-HT VDE Ignition Wire 1.8/3.0 kV Silicone

ECS-HT VDE ignition wire is a flexible silicone-insulated wire for ignition circuits and electric-arc generation in stated piezo-electric and gas- or oil-burner equipment. The supplied construction has a class 5 tin-plated copper conductor, type EI2 silicone-rubber insulation, a continuous operating range of −60°C to +180°C, 1.8/3.0 kV rated voltage and 10 kV pulse voltage.

The ECS-HT VDE ignition wire is supplied in 0.75, 1.0 and 1.5 mm² flexible constructions.

  • Conductor: flexible tin-plated copper, class 5
  • Insulation: silicone rubber type EI2
  • Temperature: −60°C to +180°C continuous operation
  • Voltage: 1.8/3.0 kV rated; 10 kV pulse
  • Flexible sizes: 0.75, 1.0 and 1.5 mm²
  • Standard colours: white, black, brick red and colourless
  • VDE: approval stated in supplied source, Licence No. 106491

Send the required size, colour, cable marking, burner or appliance type, route length and documentation requirement for a technical quotation.

Product information
Brand
TEBAOFLEX
Product overview

ECS-HT VDE silicone ignition wire for burner and appliance circuits

TEBAOFLEX ECS-HT VDE ignition wire is a flexible silicone-insulated single-core wire for ignition circuits that create an electric arc. The supplied information identifies piezo-electric components in household electrical appliances and gas or oil burners for boilers and professional appliances as the intended equipment. With a stated continuous operating range of −60°C to +180°C, the ECS-HT VDE ignition wire provides a defined option where an ordinary appliance wire would not match the system’s temperature or pulse-voltage requirements.

The supplied flexible ECS-HT VDE ignition wire sizes are 0.75, 1.0 and 1.5 mm². Each uses a class 5 tin-plated copper conductor and EI2 silicone-rubber insulation. The product data gives a 1.8/3.0 kV rated voltage and 10 kV pulse voltage; it should not be treated as a substitute for a screened, armoured or mechanically protected cable where the equipment route requires those features.

  • Suitable for: stated ignition circuits, piezo-electric components, and gas or oil burner equipment.
  • Confirm before ordering: ECS-HT VDE ignition wire system voltage, pulse requirement, size, colour, cable length, route and termination.
  • Choose another construction when: the installation needs a screen, mechanical protection or an environmental performance rating not supplied for this ECS-HT VDE ignition wire.

See the high-temperature cable range for other heat-resistant cable constructions. Detailed ECS-HT VDE ignition wire construction, applications, nominal data and standard references are in the technical tabs.

Construction

ECS-HT VDE ignition wire construction

The supplied ECS-HT VDE ignition wire construction is a single flexible, tin-plated copper conductor with silicone-rubber insulation. The conductor is class 5 under IEC 60228 / DIN VDE 0295, and the supplied insulation reference is silicone rubber type EI2 under DIN EN 50363-1.

For an ignition circuit, this simple single-core construction should be selected against the required voltage, conductor size, termination and routing conditions. The ECS-HT VDE ignition wire is not a screened or armoured cable; confirm any mechanical protection, separation and termination requirements in the equipment design.

Specifying the ECS-HT VDE ignition wire construction

Construction elementSupplied ECS-HT VDE ignition wire reference
ConductorFlexible tin-plated copper core
Conductor classClass 5 according to IEC 60228 / DIN VDE 0295
InsulationSilicone rubber, type EI2, DIN EN 50363-1
Standard insulation coloursWhite, black, brick red and colourless

The supplied catalogue also identifies a separate solid-core RECS-HT VDE option. That option is not represented as an ECS-HT VDE ignition wire size in the table below; confirm the required conductor class before quotation.

Applications

ECS-HT VDE ignition wire applications

The supplied ECS-HT VDE ignition wire is intended for ignition circuits and the creation of an electric arc. The supplied application examples are piezo-electric components in household electrical appliances and gas or oil burners for boilers and professional appliances.

ECS-HT VDE ignition wire used for piezo ignition and gas or oil burner equipment
Illustrative ignition-system applications for ECS-HT VDE wire; confirm the final equipment and routing requirements.

Selection checks for ECS-HT VDE ignition wire

  • Confirm the ignition-system voltage, pulse requirement, conductor size and total route length.
  • Check the equipment temperature profile against the stated continuous operating range of −60°C to +180°C.
  • Confirm the required silicone-insulation colour, sheath marking and termination arrangement.
  • Where the route is exposed to abrasion, movement, liquids or other external conditions, define the required protection with the equipment design; those conditions are not supplied as ECS-HT VDE ignition wire performance ratings.

For a technical quotation, send the existing cable marking or model, required ECS-HT VDE ignition wire cross-section, colour, length, quantity, burner or appliance type, and any requested documentation.

Specifications

ECS-HT VDE ignition wire specifications

The following nominal data are transcribed from the supplied ECS-HT VDE ignition wire information for flexible class 5 constructions. Confirm the final conductor size, colour and equipment requirements before order release.

The ECS-HT VDE ignition wire operating values below are product-specific reference data, not a substitute for the final equipment design.

Continuous operating temperature−60°C to +180°C
Rated voltage1.8/3.0 kV
Pulse voltage10 kV
General characteristics stated in supplied materialGood resistance to thermal shock and UV

ECS-HT VDE ignition wire size and resistance data

Nominal cross-section (mm²)Nominal strandingMaximum linear resistance at 20°C (Ω/km)Nominal insulation thickness (mm)Nominal outer diameter (mm)Approximate linear weight (kg/km)
0.7524 × 0.2026.71.33.822.0
1.032 × 0.2020.01.33.924.6
1.530 × 0.2513.71.34.230.7

These ECS-HT VDE ignition wire values apply to the supplied flexible constructions. Bending radius, current-carrying capacity, flame behaviour, oil resistance and installation-method limits were not supplied and are not stated as product claims.

Standards

ECS-HT VDE ignition wire standards

The supplied ECS-HT VDE ignition wire material lists the following approval and standard references. Include the requested document, standard edition and final conductor size in the RFQ.

Use these ECS-HT VDE ignition wire references when comparing the cable marking and requested documentation.

VDE approvalVDE approval; Licence No. 106491
Conductor class referenceIEC 60228 / DIN VDE 0295, class 5
Insulation material referenceDIN EN 50363-1, silicone rubber type EI2
Halogen-free referenceIEC 60754-1 / EN 60754-1

The VDE approval and standards wording above is retained from the supplied ECS-HT VDE ignition wire material. Confirm the requested configuration and documentation scope for the order.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    Optional: attach a cable specification, drawing, data sheet or product image (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG or PNG; maximum 10 MB).

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.