FZLSi 10 kV & 12 kV High-Voltage Silicone Ignition Cable (180 °C)
FZLSi high-voltage silicone ignition cable (10 kV and 12 kV nominal ignition rating, 20 kV AC routine test voltage) combines an IEC 60228 Class 5 tinned copper conductor (1.0, 1.5 or 2.5 mm²) with a high-dielectric silicone inner core, an intermediate braided glass-fibre reinforcing sheath and a halogen-free silicone rubber outer jacket rated -50 °C to +180 °C (+200 °C short-time).
FZLSi 10 kV and 12 kV high-voltage ignition cables provide mechanically reinforced, halogen-free spark-electrode power transmission across -50 °C to +180 °C (+200 °C transient) thermal process zones, covering 1×1.0 mm², 1×1.5 mm² and 1×2.5 mm² Class 5 tinned copper cross-sections with 7.2 mm to 8.8 mm nominal outer diameter, 60 kg/km to 105 kg/km cable mass and 20 kV AC test withstand.
Single-wall unbraided 7 kV or 10 kV silicone ignition leads frequently suffer radial insulation cracking, gland pinch-through or mechanical tear when routed past vibrating gas-train valves, hot boiler sight-ports and sheet-metal burner housings. FZLSi embeds a high-tensile braided glass-fibre inner armour directly between the high-dielectric inner silicone insulation and the outer weather- and ozone-resistant silicone sheath, arresting crack propagation while preserving tight 7.5x OD fixed routing flexibility.
Specify FZLSi 10 kV or 12 kV whenever industrial gas/oil burners, kilnpilot igniters, thermal oxidizers or HVAC/refrigeration corona units experience combined transient radiant heat and mechanical vibration; choose compact 1.8/3.0 kV ECS-HT for low-energy domestic piezo/electronic igniters, or 25 kV flare-stack ignition cable above 12 kV AC (MOQ 50 m, 100 m standard reels, 7 to 45 working days).
Explore the high-temperature wire and cable range for related configurations.
FZLSi 10 kV & 12 kV Tri-Layer Silicone-Glass-Silicone Construction
Every TEBAOFLEX FZLSi high-voltage ignition cable is extruded and braided as a concentric four-element assembly so the outer elastomer stays smooth and waterproof while the internal fiberglass braid carries pull and clamp loads.

| Component | Material and construction |
|---|---|
| 1. Flexible Tinned Copper Conductor (IEC 60228 Class 5) | Fine-stranded annealed tin-plated copper in 1.0 mm² (max 20.0 Ohm/km at 20 °C), 1.5 mm² (max 13.7 Ohm/km) or 2.5 mm² (max 8.21 Ohm/km) for corrosion-free screw/crimp termination on ignition transformers and ceramic spark rods. |
| 2. High-Dielectric Inner Silicone Rubber Insulation | Void-free extruded high-voltage silicone compound engineered for corona and ozone resistance under repetitive 10 kV to 12 kV ignition transformer firing cycles. |
| 3. Intermediate Braided Glass-Fibre Reinforcing Sheath | Concentric alkali-free E-glass yarn braid locked around the HV core to distribute gland compression, resist cut-through and stabilize core concentricity during tight bends. |
| 4. Halogen-Free Silicone Rubber Outer Jacket | Smooth wipe-clean brick-red (RD), black (BK) or blue (BU) silicone elastomer outer sheath (-50 °C to +180 °C) compliant with IEC 60754 / DIN EN 50267 halogen-free requirements. |
FZLSi High-Voltage Ignition Designation Breakdown
- FZ / Zündleitung: High-voltage flexible ignition lead designed for pulsed transformer spark-electrode circuits
- L (Litze): Fine-stranded flexible IEC 60228 Class 5 tinned copper conductor (1.0, 1.5 or 2.5 mm²)
- Si (Inner): High-dielectric corona-resistant silicone rubber primary HV core insulation
- GL (Interlayer): Embedded braided glass-fibre inner reinforcing sheath preventing radial cracking and gland cut-through
- Si (Outer): Halogen-free wipe-clean outer silicone rubber jacket (-50 °C to +180 °C, 10 kV / 12 kV)
FZLSi Industrial Burner, Kiln, Boiler & Oxidizer Applications
Install FZLSi 10 kV and 12 kV reinforced silicone ignition cables on industrial combustion, thermal process, melting furnace and environmental exhaust treatment systems.

- Industrial gas and dual-fuel burners on steam boilers, steel reheat furnaces, aluminum melting ovens, ceramic tunnel kilns and glass forehearths.
- Thermal oxidizers (RTO / TO), petrochemical pilot igniters, biogas/landfill-gas flare manifolds and hot-gas generators.
- Commercial heating plants, paint-curing oven burner trains and refrigeration/air-conditioning electrostatic or corona discharge modules.
- Long-run ignition transformer-to-electrode interconnects where zero-resistance Class 5 tinned copper prevents voltage drop across 5 m to 25 m conduit runs.
FZLSi 10/12 kV vs 7/10 kV Unbraided vs ECS-HT vs 25 kV Flare Cable
| Ignition Cable Type | Voltage & Test Rating | Dielectric & Mechanical Wall | When to Specify |
|---|---|---|---|
| FZLSi 10 kV & 12 kV (this page) | 10 kV / 12 kV (20 kV AC test), 180 °C | Silicone + internal glass braid + silicone (7.2–8.8 mm OD) | Industrial gas/oil burners & kilns needing cut/crush reinforcement & wipe-clean outer silicone |
| 7/10 kV Silicone Ignition Cable | 7 kV / 10 kV, 180 °C | Single-extrusion unbraided heavy-wall silicone (5.0–7.0 mm OD) | Enclosed burner housings & routing tubes without sharp mechanical pinch points |
| ECS-HT VDE Silicone Ignition Wire | 1.8/3.0 kV AC, 180 °C | Compact single-wall EI2 silicone (2.8–4.4 mm OD) | Compact commercial catering ovens, pellet stoves & low-voltage electronic igniters |
| 25 kV Flare Stack Ignition Cable | 10 kV AC / 25 kV DC, 250 °C (up to 538 °C) | PTFE/silicone/mica-glass high-energy HV construction | Refinery elevated flare stacks, high-energy exciter boxes & >200 °C radiant zones |
Specify FZLSi 10 kV or 12 kV whenever burner housings combine high-voltage corona, oil/soot mist and gland pinch forces up to +180 °C.
FZLSi 10 kV & 12 kV Burner Ignition Cable RFQ Checklist
- Ignition transformer secondary output voltage (10 kV or 12 kV peak/RMS) and firing duty (intermittent pilot vs continuous spark).
- Conductor cross-section (1x1.0 mm², 1x1.5 mm² or 1x2.5 mm²) and maximum ignition cable run length from transformer to electrode.
- Required nominal outer diameter window (e.g., 7.2 mm, 7.6 mm, 7.8 mm or 8.1 mm) to match existing M16/PG7 burner cable glands and ceramic insulators.
- Outer silicone jacket colour (brick red RD, black BK, or blue BU for dual-burner circuit identification) and ambient temperature exposure.
- Total meterage and reel put-up (MOQ 50 m; 100 m or 500 m bulk reels, 7 to 45 working days lead time).
Related selection resources
- High-temperature silicone and industrial burner ignition cable catalog
- Unbraided 7/10 kV single-wall silicone ignition cable for enclosed burner tubes
- ECS-HT 1.8/3.0 kV compact silicone ignition wire for commercial appliances
- 25 kV DC / 10 kV AC 250 °C petrochemical flare-stack ignition cable
- Engineering guide: Selecting high-temperature insulation for furnace & burner zones
FZLSi High-Voltage Silicone Ignition Cable FAQ
What does the FZLSi cable designation stand for?
4 concentric functional elements: FZLSi denotes a high-voltage flexible ignition cable (Fahrzeug-/Feuerungs-Zündleitung) with a Class 5 tinned copper core, silicone HV inner insulation, an internal braided glass-fibre reinforcing sheath, and an outer silicone jacket (-50 °C to +180 °C).
Why choose internal glass-braided FZLSi over an external fiberglass-braided ignition wire?
10 kV to 12 kV moisture and oil-tracking prevention. An exposed external glass braid wicks burner oil mist and condensation, whereas FZLSi encapsulates the glass-fibre braid beneath a smooth outer silicone jacket so the cable stays wipe-clean and tear-resistant.
What test voltage is applied to FZLSi 10 kV and 12 kV ignition cables?
20 kV AC. TEBAOFLEX verifies FZLSi 1x1.0 mm², 1x1.5 mm² and 1x2.5 mm² ignition cables at 20 kV AC routine dielectric test voltage alongside 20 °C DC conductor resistance checks (20.0 Ohm/km for 1.0 mm² and 13.7 Ohm/km for 1.5 mm²).
Does FZLSi come with pre-moulded spark plug boots or in bulk industrial reels?
No pre-moulded car boots; FZLSi ships on 50 m, 100 m and 500 m bulk industrial reels (MOQ 50 m) so OEM burner builders and plant maintenance teams can cut exact conduit lengths and fit screw-in or crimp Rajah/M4 electrode terminals.
Can FZLSi operate continuously at +180 °C near boiler sight-ports?
Yes. Both the inner HV dielectric and outer jacket use cross-linked halogen-free silicone rubber rated from -50 °C to +180 °C continuous (+200 °C short-term peaks). Above +200 °C radiant heat, upgrade to our 250 °C / 538 °C flare-stack igniter cable.
FZLSi 10 kV & 12 kV Dimensional, Resistance & 20 kV Test Schedule
FZLSi Key Voltage, Conductor Resistance, OD & Reel Summary
- Triple-layer HV geometry: Extruded silicone HV core dielectric + intermediate braided fiberglass reinforcement + outer silicone jacket prevents corona puncture and thermal splitting
- 10 kV & 12 kV ignition classes: Engineered for continuous 10 kV and 12 kV high-voltage transformer ignition pulses with 20 kV AC factory dielectric verification
- Low-loss Class 5 tinned copper: 1x1.0 mm² (20.0 Ohm/km), 1x1.5 mm² (13.7 Ohm/km) and 1x2.5 mm² (8.21 Ohm/km) fine-stranded tinned copper delivers full spark energy over long burner runs
- Halogen-free & thermal shock proof: -50 °C to +180 °C fixed/flexible service temperature and halogen-free acid-gas compliance per IEC 60754-1 / DIN EN 50267
- Industrial burner bulk reels: Supplied in red, black or blue outer sheaths on 100 m coils/reels with a 50 m minimum order quantity and 7 to 45 working days lead time
| Parameter | Value |
|---|---|
| Rated voltage | 10 kV and 12 kV high-voltage ignition service rating with 20 kV AC factory dielectric withstand test |
| Conductor and DC resistance | IEC 60228 Class 5 tinned copper in 1x1.0 mm2 (20.0 Ohm/km), 1x1.5 mm2 (13.7 Ohm/km) and 1x2.5 mm2 (8.21 Ohm/km) |
| Tri-layer insulation system | High-dielectric silicone inner core plus intermediate braided glass-fibre sheath plus outer halogen-free silicone jacket |
| Operating temperature and bend radius | -50 C to +180 C continuous (+200 C transient) with 7.5x OD minimum fixed bend radius and 12x OD flexing radius |
| Standard put-up and lead time | MOQ 50 m (standard 100 m and 500 m bulk reels in red, black or blue) with 7 to 45 working days manufacturing lead time |
| Halogen-free and ozone resistance | Halogen-free per IEC 60754-1 / DIN EN 50267; inherently resistant to HV corona ozone, condensation, UV and burner oil mist |
| EMI engineering note | Metallic low-resistance copper conductor provides maximum spark energy without resistive suppression; route separately from 4-20 mA flame-scanner signal cables |
FZLSi 10 kV & 12 kV Tinned Copper + Glass-Braid + Silicone Schedule
| Model, Size & Voltage | Sheath Colour | Max. Conductor Resistance at 20 °C (Ω/km) | Nominal OD (mm) | Copper Index (kg/km) | Approx. Cable Weight (kg/km) | Test Voltage (kV AC) | Next step |
|---|---|---|---|---|---|---|---|
| FZLSi 1x1.0 mm² 10 kV RD | Brick Red (RD) | 20.0 | 7.2 | 9.6 | 60 | 20 kV | Request this size |
| FZLSi 1x1.0 mm² 10 kV BK | Black (BK) | 20.0 | 7.2 | 9.6 | 60 | 20 kV | Request this size |
| FZLSi 1x1.5 mm² 10 kV BK | Black (BK) | 13.7 | 8.1 | 14.4 | 70 | 20 kV | Request this size |
| FZLSi 1x1.5 mm² 10 kV RD | Brick Red (RD) | 13.7 | 8.1 | 14.4 | 70 | 20 kV | Request this size |
| FZLSi 1x1.5 mm² 12 kV RD | Brick Red (RD) | 13.7 | 7.6 | 14.4 | 71 | 20 kV | Request this size |
| FZLSi 1x1.5 mm² 12 kV BU | Blue (BU) | 13.7 | 7.8 | 14.4 | 95 | 20 kV | Request this size |
| FZLSi 1x2.5 mm² 10 kV RD | Brick Red (RD) | 8.21 | 8.6 | 24.0 | 98 | 20 kV | Request this size |
| FZLSi 1x2.5 mm² 12 kV RD | Brick Red (RD) | 8.21 | 8.8 | 24.0 | 105 | 20 kV | Request this size |
Electrical and dimensional values follow European FZLSi thermal-process ignition cable geometry using IEC 60228 Class 5 tinned copper, extruded silicone HV core dielectric, braided glass-fibre intermediate reinforcement and outer silicone rubber jacket; final values are confirmed on the quotation drawing.
Because FZLSi uses a metallic Class 5 tinned copper conductor (13.7 to 20.0 Ohm/km) with zero carbon-core RFI suppression, segregate HV ignition conduits at least 150 to 300 mm from UV flame-detector and thermocouple signal cables.
Minimum order quantity is 50 m per cross-section and sheath colour (supplied on 50 m, 100 m or 500 m bulk factory reels/coils, without automotive spark-plug boots attached), with a 7 to 45 working days production lead time.
ASCII part references for BOM and ERP entry: TF-FZLSI-1X1.0-10KV-RD; TF-FZLSI-1X1.0-10KV-BK; TF-FZLSI-1X1.5-10KV-BK; TF-FZLSI-1X1.5-10KV-RD; TF-FZLSI-1X1.5-12KV-RD; TF-FZLSI-1X1.5-12KV-BU; TF-FZLSI-1X2.5-10KV-RD; TF-FZLSI-1X2.5-12KV-RD.
FZLSi IEC 60228, IEC 60754 Halogen-Free & 20 kV Test Standards
| Standard or specification | Application |
|---|---|
| IEC 60228 / DIN EN 60228 Class 5 | Flexible fine-stranded tinned copper conductor construction and maximum 20 °C DC conductor resistance (20.0 Ohm/km on 1.0 mm²; 13.7 Ohm/km on 1.5 mm²). |
| DIN EN 50267 / IEC 60754-1 & IEC 60754-2 | Halogen-free material verification ensuring zero corrosive hydrohalic acid gas release around boiler instrumentation and stainless burner manifolds. |
| DIN VDE 0250 / Industrial FZLSi HV Test Protocol (20 kV AC) | Concentric silicone-glass-silicone wall integrity and 20 kV AC dielectric withstand verification for 10 kV and 12 kV ignition transformer secondary circuits. |
| IEC 60332-1-2 | Flame-retardant behaviour on single vertical insulated wire and inorganic SiO2 + glass-braid ash retention. |
Certifications and document support
TEBAOFLEX ISO 9001 manufacturing quality system and HV test documentation
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
7/10 kV Silicone Ignition Cable
A related cable option for a different application or duty profile.
View productECS-HT VDE Ignition Wire 1.8/3.0 kV Silicone
A related cable option for a different application or duty profile.
View productStyle 3304 & Style 3573 10 kV Silicone Ignition Wire
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.