ECS-HT VDE Ignition Wire 1.8/3.0 kV Silicone
ECS-HT VDE ignition wire is a flexible silicone-insulated wire for ignition circuits and electric-arc generation in stated piezo-electric and gas- or oil-burner equipment. The supplied construction has a class 5 tin-plated copper conductor, type EI2 silicone-rubber insulation, a continuous operating range of −60°C to +180°C, 1.8/3.0 kV rated voltage and 10 kV pulse voltage.
The ECS-HT VDE ignition wire is supplied in 0.75, 1.0 and 1.5 mm² flexible constructions.
- Conductor: flexible tin-plated copper, class 5
- Insulation: silicone rubber type EI2
- Temperature: −60°C to +180°C continuous operation
- Voltage: 1.8/3.0 kV rated; 10 kV pulse
- Flexible sizes: 0.75, 1.0 and 1.5 mm²
- Standard colours: white, black, brick red and colourless
- VDE: approval stated in supplied source, Licence No. 106491
Send the required size, colour, cable marking, burner or appliance type, route length and documentation requirement for a technical quotation.
ECS-HT VDE silicone ignition wire for burner and appliance circuits
TEBAOFLEX ECS-HT VDE ignition wire is a flexible silicone-insulated single-core wire for ignition circuits that create an electric arc. The supplied information identifies piezo-electric components in household electrical appliances and gas or oil burners for boilers and professional appliances as the intended equipment. With a stated continuous operating range of −60°C to +180°C, the ECS-HT VDE ignition wire provides a defined option where an ordinary appliance wire would not match the system’s temperature or pulse-voltage requirements.
The supplied flexible ECS-HT VDE ignition wire sizes are 0.75, 1.0 and 1.5 mm². Each uses a class 5 tin-plated copper conductor and EI2 silicone-rubber insulation. The product data gives a 1.8/3.0 kV rated voltage and 10 kV pulse voltage; it should not be treated as a substitute for a screened, armoured or mechanically protected cable where the equipment route requires those features.
- Suitable for: stated ignition circuits, piezo-electric components, and gas or oil burner equipment.
- Confirm before ordering: ECS-HT VDE ignition wire system voltage, pulse requirement, size, colour, cable length, route and termination.
- Choose another construction when: the installation needs a screen, mechanical protection or an environmental performance rating not supplied for this ECS-HT VDE ignition wire.
See the high-temperature cable range for other heat-resistant cable constructions. Detailed ECS-HT VDE ignition wire construction, applications, nominal data and standard references are in the technical tabs.
ECS-HT VDE ignition wire construction
The supplied ECS-HT VDE ignition wire construction is a single flexible, tin-plated copper conductor with silicone-rubber insulation. The conductor is class 5 under IEC 60228 / DIN VDE 0295, and the supplied insulation reference is silicone rubber type EI2 under DIN EN 50363-1.
For an ignition circuit, this simple single-core construction should be selected against the required voltage, conductor size, termination and routing conditions. The ECS-HT VDE ignition wire is not a screened or armoured cable; confirm any mechanical protection, separation and termination requirements in the equipment design.
Specifying the ECS-HT VDE ignition wire construction
| Construction element | Supplied ECS-HT VDE ignition wire reference |
|---|---|
| Conductor | Flexible tin-plated copper core |
| Conductor class | Class 5 according to IEC 60228 / DIN VDE 0295 |
| Insulation | Silicone rubber, type EI2, DIN EN 50363-1 |
| Standard insulation colours | White, black, brick red and colourless |
The supplied catalogue also identifies a separate solid-core RECS-HT VDE option. That option is not represented as an ECS-HT VDE ignition wire size in the table below; confirm the required conductor class before quotation.
ECS-HT VDE ignition wire applications
The supplied ECS-HT VDE ignition wire is intended for ignition circuits and the creation of an electric arc. The supplied application examples are piezo-electric components in household electrical appliances and gas or oil burners for boilers and professional appliances.

Selection checks for ECS-HT VDE ignition wire
- Confirm the ignition-system voltage, pulse requirement, conductor size and total route length.
- Check the equipment temperature profile against the stated continuous operating range of −60°C to +180°C.
- Confirm the required silicone-insulation colour, sheath marking and termination arrangement.
- Where the route is exposed to abrasion, movement, liquids or other external conditions, define the required protection with the equipment design; those conditions are not supplied as ECS-HT VDE ignition wire performance ratings.
For a technical quotation, send the existing cable marking or model, required ECS-HT VDE ignition wire cross-section, colour, length, quantity, burner or appliance type, and any requested documentation.
ECS-HT VDE ignition wire specifications
The following nominal data are transcribed from the supplied ECS-HT VDE ignition wire information for flexible class 5 constructions. Confirm the final conductor size, colour and equipment requirements before order release.
The ECS-HT VDE ignition wire operating values below are product-specific reference data, not a substitute for the final equipment design.
| Continuous operating temperature | −60°C to +180°C |
|---|---|
| Rated voltage | 1.8/3.0 kV |
| Pulse voltage | 10 kV |
| General characteristics stated in supplied material | Good resistance to thermal shock and UV |
ECS-HT VDE ignition wire size and resistance data
| Nominal cross-section (mm²) | Nominal stranding | Maximum linear resistance at 20°C (Ω/km) | Nominal insulation thickness (mm) | Nominal outer diameter (mm) | Approximate linear weight (kg/km) |
|---|---|---|---|---|---|
| 0.75 | 24 × 0.20 | 26.7 | 1.3 | 3.8 | 22.0 |
| 1.0 | 32 × 0.20 | 20.0 | 1.3 | 3.9 | 24.6 |
| 1.5 | 30 × 0.25 | 13.7 | 1.3 | 4.2 | 30.7 |
These ECS-HT VDE ignition wire values apply to the supplied flexible constructions. Bending radius, current-carrying capacity, flame behaviour, oil resistance and installation-method limits were not supplied and are not stated as product claims.
ECS-HT VDE ignition wire standards
The supplied ECS-HT VDE ignition wire material lists the following approval and standard references. Include the requested document, standard edition and final conductor size in the RFQ.
Use these ECS-HT VDE ignition wire references when comparing the cable marking and requested documentation.
| VDE approval | VDE approval; Licence No. 106491 |
|---|---|
| Conductor class reference | IEC 60228 / DIN VDE 0295, class 5 |
| Insulation material reference | DIN EN 50363-1, silicone rubber type EI2 |
| Halogen-free reference | IEC 60754-1 / EN 60754-1 |
The VDE approval and standards wording above is retained from the supplied ECS-HT VDE ignition wire material. Confirm the requested configuration and documentation scope for the order.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Braidless Silicone Rubber Cable 5kV 200°C Single Core
A related cable option for a different application or duty profile.
View productSiF Silicone 180 Single Core Flexible Cable
A related cable option for a different application or duty profile.
View productH03S-K Single Core Silicone Rubber High Temperature Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.