Style 3304 & Style 3573 10 kV Silicone Ignition Wire
10 kV silicone ignition wire in Style 3304 and Style 3573 constructions is a silicone-insulated, braid-reinforced choice for stated burner and piezo-electric ignition circuits. The supplied data lists −60°C to +200°C continuous operation, 10 kV AC pulse voltage and UL 758 recognition under File No. E101965.
This 10 kV silicone ignition wire family offers conductor, braid and size choices that should be matched to the existing wire marking and equipment route.
- Temperature: −60°C to +200°C continuous operation
- Pulse voltage: 10 kV AC
- Insulation: silicone rubber, 1.0 mm average thickness in supplied data
- Reinforcement: Style-specific fibreglass braid construction
- Sizes: 0.34 to 4.0 mm² as listed, plus other cross-sections on request
- Standard colours: white, black, brick red and colourless
Send the required style, conductor material, size, colour, length, burner or appliance type and documentation requirement for a 10 kV silicone ignition wire quotation.
Style 3304 and Style 3573 10 kV silicone ignition wire
TEBAOFLEX Style 3304 and Style 3573 10 kV silicone ignition wire covers two silicone-insulated, reinforcement-braid constructions for ignition circuits and electric-arc generation. The supplied material identifies use with piezo-electric components in household electrical appliances and with gas or oil burners in boiler and professional-appliance equipment. The stated −60°C to +200°C continuous range and 10 kV AC pulse voltage give buyers a defined starting point for high-temperature ignition-circuit selection.
The two 10 kV silicone ignition wire styles use different braid arrangements. Style 3304 is shown with a silicone-coated fibreglass braid, while Style 3573 is shown with a fibreglass braid and silicone-rubber layers. This page records the shared supplied ratings and nominal diameters, but the final choice must follow the exact equipment drawing, wire marking, termination and routing conditions.
- Suitable for: stated burner, boiler, professional-appliance and piezo-electric ignition circuits.
- Confirm before ordering: Style 3304 or 3573, conductor material, size, temperature, pulse-voltage requirement, colour, length and termination.
- Choose another construction when: the route needs a screen, armour or an environmental rating not supplied for this 10 kV silicone ignition wire family.
Explore the high-temperature cable range for other heat-resistant constructions. The Construction, Applications, Specifications and Standards tabs provide the product-specific 10 kV silicone ignition wire details.
10 kV silicone ignition wire construction
This 10 kV silicone ignition wire family combines a copper conductor, silicone-rubber insulation and a reinforcement braid. The supplied source identifies bare, tin-plated, nickel-plated or silver-plated copper conductor options; Style 3304 is illustrated with a silicone-coated fibreglass braid, while Style 3573 adds a fibreglass braid within a silicone-insulated construction.
Select the 10 kV silicone ignition wire construction by the required conductor material, equipment temperature, route and handling conditions. The supplied information does not establish a universal replacement relationship between Style 3304 and Style 3573, so the existing wire marking and the specified style should be confirmed before quotation.
10 kV silicone ignition wire construction choice
| Construction element | Supplied 10 kV silicone ignition wire reference |
|---|---|
| Conductor choices | Bare copper, tin-plated copper, nickel-plated copper or silver-plated copper |
| Insulation | Silicone rubber |
| Style 3304 reinforcement | Silicone-coated fibreglass braid |
| Style 3573 reinforcement | Fibreglass braid with silicone-rubber layers as illustrated in supplied material |
| Standard insulation colours | White, black, brick red and colourless |
The 10 kV silicone ignition wire drawing shown in the supplied product image is an illustration of the two construction styles. Confirm the final conductor plating, braid treatment and colour against the approved order specification.
10 kV silicone ignition wire applications
The supplied 10 kV silicone ignition wire applications are ignition circuits and electric-arc generation for piezo-electric components in household electrical appliances, plus gas or oil burners for boilers and professional appliances.

10 kV silicone ignition wire selection checks
- Confirm the stated 10 kV AC pulse-voltage requirement against the ignition-system design.
- Confirm the continuous operating-temperature requirement against the supplied −60°C to +200°C range.
- Specify Style 3304 or Style 3573, conductor material, nominal cross-section, insulation colour, length and termination.
- For a route exposed to abrasion, movement, liquids or other conditions not supplied for this product, define the required protection with the equipment designer before selecting the 10 kV silicone ignition wire.
Send the existing marking, ignition equipment type, required 10 kV silicone ignition wire style, size, route, quantity and documentation requirement for a technical quotation.
10 kV silicone ignition wire specifications
The following nominal data is transcribed from the supplied Style 3304 and Style 3573 material. Both 10 kV silicone ignition wire styles are listed with 1.0 mm average insulation thickness and a continuous operating range of −60°C to +200°C.
10 kV silicone ignition wire operating reference
| Style 3304 rating entry | 200°C – 10000 V |
|---|---|
| Style 3573 rating entry | 200°C – 10000 V |
| Pulse voltage | 10 kV AC |
| Thermal and UV characteristic stated in supplied material | Good resistance to thermal shock and UV |
10 kV silicone ignition wire nominal size and diameter data
| AWG | Nominal cross-section (mm²) | Style 3304 average insulation thickness (mm) | Style 3304 nominal diameter (mm) | Style 3573 average insulation thickness (mm) | Style 3573 nominal diameter (mm) |
|---|---|---|---|---|---|
| 22 | 0.34 | 1.0 | 3.1 | 1.0 | 3.2 |
| – | 0.5 | 1.0 | 3.2 | 1.0 | 3.4 |
| 20 | 0.6 | 1.0 | 3.4 | 1.0 | 3.6 |
| – | 0.75 | 1.0 | 3.5 | 1.0 | 3.7 |
| 18 | 0.93 | 1.0 | 3.5 | 1.0 | 3.7 |
| – | 1.0 | 1.0 | 3.7 | 1.0 | 3.9 |
| 16 | 1.34 | 1.0 | 3.8 | 1.0 | 4.1 |
| – | 1.5 | 1.0 | 4.0 | 1.0 | 4.3 |
| 14 | – | 1.0 | 4.3 | 1.0 | 4.6 |
| – | 2.5 | 1.0 | 4.5 | 1.0 | 4.8 |
| 12 | – | 1.0 | 4.8 | 1.0 | 5.0 |
| – | 4.0 | 1.0 | 5.0 | 1.0 | 5.3 |
Nominal diameter is provided for selection information and may vary with conductor stranding. The supplied source identifies other nominal cross-sections and conductor stranding as quotation options. Bending radius, current capacity, oil resistance and installation-method limits are not supplied for this 10 kV silicone ignition wire family.
10 kV silicone ignition wire standards
The supplied 10 kV silicone ignition wire material lists UL approval under UL 758, File No. E101965. It also identifies a horizontal flame test under the UL approval.
| UL approval reference | UL 758, File No. E101965 |
|---|---|
| Halogen-free reference | IEC 60754-1 / EN 60754-1 |
| Flame-test wording in supplied material | “Horizontal flame test” as per UL approval |
| Optional test stated in supplied material | Vertical flame test VW-1: contact us |
When comparing the 10 kV silicone ignition wire marking to the specified appliance requirement, confirm the requested style, conductor, size and document scope. The supplied optional VW-1 wording is retained as an option, not an included performance claim.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
ECS-HT VDE Ignition Wire 1.8/3.0 kV Silicone
A related cable option for a different application or duty profile.
View productBraidless Silicone Rubber Cable 5kV 200°C Single Core
A related cable option for a different application or duty profile.
View productSiF Silicone 180 Single Core Flexible Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.