BS5308 / PAS5308 Instrumentation Cables TEBAOFLEX

BS5308 / PAS5308 Part 1 Type 2 Armoured Instrumentation Cable 300/500 V

BS5308 / PAS5308 Part 1 Type 2 armoured instrumentation cable: polyethylene insulated, galvanised steel wire armoured, collectively or individually and collectively screened. Confirm conductor size, unit count, screening arrangement, route and documentation requirements at RFQ.

Product information
Brand
TEBAOFLEX
Product overview

BS5308 Part 1 Type 2 armoured instrumentation cable carries analogue and digital signals between field instruments and control systems on routes that need mechanical protection. Part 1 denotes polyethylene insulation, which gives lower mutual capacitance and a wider temperature band than the PVC insulated Part 2 family. Type 2 denotes galvanised steel wire armour over a bedding layer, making the construction suitable for direct burial and for exposed routes where crushing, impact or rodent damage is credible.

Screening is a separate decision from Part and Type. A collective aluminium/polyester screen with a common tinned copper drain wire suits cables whose circuits share a signal type and an earthing reference. Individual pair or triad screens plus an overall screen suit mixed signal levels, low-level analogue circuits and any arrangement where intrinsically safe circuits must be segregated. State the screening arrangement explicitly; Part 1 Type 2 alone does not define the cable.

The armour is a mechanical element and is not a substitute for the screen. Screen and armour are terminated separately, and armour bonding must be resolved as part of the earthing design rather than assumed. Confirm gland type and armour termination method with the route drawings.

Standard status. BS 5308 Parts 1 and 2 were withdrawn in 2005 and PAS 5308-1:2009 was withdrawn by BSI on 3 April 2024. The current document covering these cables is BS EN 50288-7:2005. Cable can still be manufactured and supplied to the withdrawn constructions, but a project specifying them will normally need to record a deviation. Read the PAS 5308 specification guide before issuing a cable schedule.

Construction

Construction

ElementReference constructionBuyer check
ConductorPlain annealed copper to BS EN 60228, Class 1 solid, Class 2 stranded or Class 5 flexible.Confirm class, cross-sectional area and core identification.
InsulationPolyethylene Type 03 to BS 6234 (Part 1 family).Confirm compound where XLPE or a fire-resistant variant is required.
FormationConductors twisted as pairs, or as triads where three conductors are required.Confirm number of pairs or triads and any mixed formation.
ScreenAluminium/polyester tape, collective (CAM) or individual and collective (ICAM), with tinned copper drain wire.Confirm arrangement, drain wire size and screen bonding at both ends.
BeddingExtruded layer beneath the armour.Confirm compound where a specific fire or chemical performance is required.
ArmourGalvanised steel wire armour (SWA) over the bedding.Confirm gland type, armour termination and earthing arrangement.
SheathPVC Type TM1 to BS EN 50363, or low smoke zero halogen.Confirm compound, colour and whether blue IS identification is required.
Applications

Applications

  • Direct buried instrument and control signal routes between field areas and control buildings.
  • Exposed plant routes where crushing, impact or rodent damage is credible.
  • Analogue 4-20 mA loops, digital fieldbus and low-level transmitter signals.
  • Intrinsically safe circuits, where loop certification is held at system level and blue sheath identification is used.
  • Petrochemical, refinery, power generation and water treatment field routes.

Where the route runs entirely inside tray, trunking or conduit and no armour is required, specify the unarmoured Type 1 construction instead.

Specifications

Specifications

PropertyReference valueBuyer check
Voltage rating300/500 V (Uo/U)Confirm where a higher rating is specified for the circuit.
Conductor sizes0.5, 0.75, 1.0, 1.5 and 2.5 mm² reference rangeConfirm the size required and availability in the chosen class.
Conductor classClass 1 solid, Class 2 stranded or Class 5 flexible to BS EN 60228Solid conductors suit fixed terminations; stranded suit repeated handling.
ScreeningCollective, or individual and collectiveState explicitly. Required for IS circuit segregation.
ArmourGalvanised steel wire over beddingConfirm wire diameter, gland selection and armour earthing.
Operating temperatureReference range −30 °C to +75 °C, fixed installationConfirm against the ordered compound and the route ambient.
Minimum bending radiusReference 18 × overall diameter, fixed installationArmoured constructions are stiffer. Confirm before tray and gland detailing.
Loop parametersInductance and capacitance per unit length available on requestRequired for intrinsically safe loop verification. Request with the RFQ.
Fire performanceFlame propagation references to BS EN/IEC 60332-1 and 60332-3-24Confirm the category required by the project specification.
Standards

Standards

  • PAS 5308-1:2009 construction reference. Withdrawn by BSI on 3 April 2024.
  • BS 5308-1 construction reference. Withdrawn and superseded by EN 50288-7 in 2005.
  • BS EN 50288-7:2005, the current sectional specification for instrumentation and control cables.
  • BS EN 60228 conductor reference.
  • BS 6234 polyethylene insulation reference.
  • BS EN 50363 sheath compound reference.
  • BS EN/IEC 60332-1 and 60332-3-24 flame propagation references where specified.

Because PAS 5308 is withdrawn, no certification body issues conformity certificates against it and no supplier can offer one. Request the model-specific test and inspection documents in the RFQ. Standards names are selection references, not an approval claim.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.