High Temperature Cables

TGGT Wire — PTFE-Glass High Temperature Lead Wire 250°C, 300/600 V

TGGT stands for the four layers it is made of — Teflon, glass, glass, Teflon. It is the wire for equipment that runs hot, wet and chemically unpleasant at the same time: 250 °C in damp or dry service, with the chemical and moisture resistance of PTFE and the abrasion resistance of an impregnated glass braid. TEBAOFLEX builds it on nickel-plated copper from 18 AWG to 4/0.

  • Construction references: UL AWM style 5256 (18–2 AWG) and style 5251 (1/0 AWG and larger); CSA AWM I A/B FT1
  • Temperature: 250 °C, wet and dry
  • Voltage: 600 V; 300 V constructions available
  • Conductor: flexible stranded 2% nickel-coated copper to ASTM B355, B8, B173 and B174
  • Insulation: two PTFE tapes with a fiberglass serve
  • Jacket: braided fiberglass with a high-temperature finish, impregnated against moisture, heat and flame
  • Sizes: 18 AWG to 4/0 AWG

Send the AWG size, voltage, hot-spot temperature, length and any documentation requirement for a technical quotation.

Product information
Product overview

Cross-reference: a buyer quoting Chem-Gard 200 RTD 40551 or 40552 can compare it on the Chem-Gard 200 RTD reference review; for mica-glass Thermo-Trex 2800 RTD 41250 leads, the Thermo-Trex 41250 reference review lists the original construction before a TEBAOFLEX offer is prepared.

Construction

Construction

The name is the specification. TGGT is Teflon, glass, glass, Teflon — a four-layer composite in which no single layer does more than one job, which is why it holds together in conditions that defeat an extruded wire.

TGGT construction, from the copper outward
LayerWhat it isWhat it is there for
ConductorFlexible stranded soft-drawn copper, 2% nickel coated, to ASTM B355, B8, B173 and B174Above about 200 °C bare copper oxidises and goes brittle. A light nickel coating stops that, and improves conductance at the same time.
Inner PTFETwo non-extruded PTFE tapes, wrappedThe dielectric, and the chemical barrier. Tape rather than extrusion is what lets the wall stay thin without losing coverage on a stranded conductor.
Glass serveFiberglass tape wrapped over the PTFEMechanical reinforcement and thermal spacing between the dielectric and the outside world.
Outer braidBraided fiberglass with a high-temperature finish, impregnated against moisture, heat and flameAbrasion resistance and handling strength. This is the layer that survives being pulled through a machine frame.

2% nickel here, 27% on MGT. Both wires use nickel-plated copper, but the coating weight follows the temperature the conductor has to survive, not the product family. A 250 °C wire does not need — and should not be priced as though it needs — the heavy coating that a 450 °C wire depends on.

Why the wall is wrapped, not extruded

An extruded PTFE wire gives you a smoother, more exact wall. A tape-wrapped wall gives you something an extrusion cannot: layers that can move slightly against each other as the wire is bent hot, without the dielectric splitting. That is the reason TGGT survives thermal cycling in equipment that is switched on and off every day for years.

Cutaway of TGGT wire showing the braided fiberglass jacket, fiberglass serve, PTFE tapes and nickel-plated copper conductor
Four layers, and the name says so: Teflon, glass, glass, Teflon. The PTFE is applied as tape, which is why the wall survives being bent hot.

Reading the size range correctly

The available sizes track the UL style rather than the product name: style 5256 covers 18 AWG through 2 AWG, and style 5251 picks up at 1/0 AWG and larger. A specification that names TGGT without naming the style will usually still be quotable, but naming the style removes a round of questions. On the reasoning behind temperature ratings generally, see what a 200 °C insulation rating actually guarantees.

Applications

Applications

TGGT is apparatus and motor lead wire for the internal wiring of domestic, commercial and industrial heating equipment, cooking equipment, and the control and power circuits attached to them — anywhere high temperature and abrasion arrive together and the circuit may also be damp.

Equipment this wire is built for

Typical TGGT duty
WhereWhat it does thereWhy TGGT rather than a silicone or a plain PTFE wire
Industrial and bakery ovensInternal looms and element leads250 °C soak with steam, grease and repeated cleaning
Paint drying and curing tunnelsPower and control wiringSolvent exposure that would attack a silicone jacket
Steel rolling mills and furnacesHot-spot wiring near the lineAbrasion plus radiant heat; the glass braid takes the contact
Cement kilns and glass manufactureEquipment wiring in severe hot spotsContinuous dust abrasion at temperature
Dryers and commercial cooking equipmentInternal appliance wiringDamp-duty rating, and a wall thin enough for dense terminations
Halogen, metal halide and arc lampsLamp lead wireHigh local temperature in a very small space
Beige fiberglass-braided TGGT wire loom clipped along the wall of an industrial curing oven
A curing-oven loom: clipped clear of the plenum, through a grommeted penetration, in a chamber that is hot, damp and cleaned regularly.

Where TGGT is the wrong answer

  • Above 250 °C. PTFE begins to decompose above about 300 °C, and the fumes are a genuine health hazard, not a performance footnote. Above 250 °C the answer is MGT mica-glass lead wire at 450 °C.
  • Continuous flexing. This is lead wire and fixed internal wiring, not a flexing cable.
  • Ordinary panel and equipment wiring below 200 °C. A silicone hook up wire or a PTFE hook up wire will be cheaper, more flexible and entirely adequate.

Oven and hot-equipment circuits above 250 °C that must be specified by UL style can also be compared with the UL 5334 and UL 5335 mica-glass wires, rated 450 °C, with separate 300 V AC and 600 V AC constructions.

TGGT or MGT?

Both are sold as high-temperature lead wire, both use nickel-plated copper and an impregnated glass braid, and they are routinely substituted for each other by mistake. The dividing line is temperature, and the second line is moisture.

Choosing between TGGT and MGT
TGGTMGTChoose this when
Temperature250 °C450 °C UL, 538 °C factoryTGGT at or below 250 °C; MGT above it
InsulationPTFE tape with fiberglass serveGlass-reinforced mica tapeTGGT for chemical and moisture duty; MGT where nothing may melt
Wet dutyRated damp or dryReview before specifyingTGGT where moisture is part of the duty
Conductor coating2% nickel27% nickelFollows the temperature, and it is a real cost difference
HandlingThinner wall, more flexibleThicker wall, stifferTGGT where the loom is tight or terminations are dense
Specifications

Specifications

Ratings at a glance

Temperature
250 °C, wet and dry
Voltage
600 V; 300 V constructions available by style
Sizes
18 AWG to 4/0 AWG, by style
Conductor
Flexible stranded soft-drawn copper, 2% nickel coated, ASTM B355 / B8 / B173 / B174
Insulation
Two PTFE tapes with a fiberglass serve
Jacket
Braided fiberglass, high-temperature finish, impregnated against moisture, heat and flame
Flame
VW-1 flame test; CSA AWM I A/B FT1 construction reference

TGGT 250 °C / 600 V — dimensional data

Nominal construction data. All values nominal and subject to correction against the ordered cable.
SizeStrandsPTFE wall (mm)Glass wrap (mm)Braid (mm)Overall dia. (mm)Min. bend radius (in)Net weight (lbs/kft)
TGGT 18 AWG190.380.250.132.290.729
TGGT 16 AWG260.380.250.132.720.8614
TGGT 14 AWG410.380.250.133.050.9620
TGGT 12 AWG650.380.380.253.531.1129
TGGT 10 AWG1050.380.380.134.171.3143
TGGT 8 AWG1330.380.380.135.361.6966
TGGT 6 AWG1330.510.380.186.532.0699
TGGT 4 AWG1330.510.380.188.512.68164
TGGT 2 AWG1330.510.380.1810.193.21248
TGGT 1/0 AWG2590.890.510.2513.494.25404
TGGT 2/0 AWG2590.890.510.2514.784.66499
TGGT 4/0 AWG2590.890.510.2517.835.62762

3/0 AWG is not shown in the reference construction data and is quoted on request. Ampacity falls sharply with temperature — a size that carries 35 A at 30 °C ambient may carry only about a third of that at 200 °C — so size the conductor against the hot-spot temperature, not the room.

Standards

Standards

What the style numbers mean here

TGGT is published across several UL AWM styles that differ in PTFE tape thickness and the number of fiberglass layers, which is why two wires both sold as TGGT can have different walls and different size ranges. TEBAOFLEX builds to the construction requirements of the following styles.

Construction and test references for TGGT
ReferenceWhat it covers in this construction
UL AWM style 5256250 °C, 600 V construction in 18 AWG through 2 AWG
UL AWM style 5251250 °C, 600 V construction in 1/0 AWG and larger
UL AWM styles 5196 / 5214 / 5180Related 250 °C constructions with different PTFE and fiberglass thicknesses; named on the enquiry where a project specifies them
CSA AWM I A/B FT1Canadian appliance wiring material designation and vertical flame test reference
UL VW-1Vertical wire flame test
ASTM B355, B8, B173, B174Nickel-coated copper wire, and rope-lay / bunch stranded conductor references

These are the standards this construction is designed and manufactured to. Certificate scope for a specific style is confirmed per order — send the style number with your enquiry and we confirm what documentation can be issued before you commit.

A safety boundary worth stating plainly

PTFE begins measurable thermal decomposition above roughly 380 °C, and its pyrolysis products cause polymer fume fever from about 300 °C upward. This is why the 250 °C rating on a PTFE-based construction is a hard design limit and not a conservative estimate, and why equipment that can overshoot into that range needs ventilation and a mica-based wire rather than a hotter-rated fluoropolymer.

Documentation supplied with an order

  • Confirm the required style number, voltage, size and any sheath marking on the purchase specification
  • Request conductor, insulation, dimensional and flame test records where the project requires them
  • State any third-party inspection, witness testing, drum schedule, custom print or packing requirement before production
Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.