NTSCGECCWOEU Armoured Monitored Mining Cable 3.6/6-6/10kV
NTSCGECCWOEU 3.6/6 kV and 6/10 kV armoured monitored mining cable to DIN VDE 0250 Part 813, for high-voltage equipment on mine and tunnel power lines under particularly high mechanical loads.
- Conductor: fine stranded tinned copper with conductive rubber smoothing layer.
- Insulation: heat-resistant 3GI3 EPR compound with outer field-limiting layer.
- Monitoring shield: conductive rubberized textile tape and copper-steel spiral.
- Armour: braided galvanised steel wires forming an earthed external shield.
- Outer sheath: red chlorinated rubber 5GM5.
Send voltage, machine or transformer data, route and termination requirements for RFQ review.
NTSCGECCWOEU Armoured Monitored Mining Cable
NTSCGECCWOEU is a medium-voltage trailing cable to DIN VDE 0250 Part 813 with a monitoring shield and, as its defining feature, a braided armour of galvanised steel wires fitted below the outer sheath. That armour is the difference between this designation and the otherwise similar NTSCGECWOEU: it takes particularly high mechanical loads and at the same time forms an external earthed shield.
The letter sequence matters. NTSCGECCWOEU carries two C positions and is armoured; NTSCGECWOEU has one and is not; NTSCGECECWÖU is a different monitoring construction again. These are separate cables, not spelling variants of each other, and substituting one for another on a transformer feed is a real failure mode.
- Rated voltage: 3.6/6 kV and 6/10 kV.
- Armour: braided galvanised steel wires, also acting as an earthed external shield.
- Bending radius: 4 × D static, 7.5 × D mobile.
- Monitoring: conductive rubberized textile tape plus a copper-steel spiral shield.
The phase-concentric earth conductor and the common concentric monitoring shield, used with a high-voltage protection circuit, allow the cable to be monitored for insulation faults and for damage from external influences. For the unarmoured build see (N)TSCGECWÖU TBM cable; for the separate-earth monitoring construction see (N)TSCGECECWÖU.
NTSCGECCWOEU Cable Construction
The layer sequence below is the armoured build. Positions 1 to 11 are shared with the unarmoured construction; position 12, the galvanised steel wire braid, is what makes this NTSCGECCWOEU.

| No. | Layer | Construction |
|---|---|---|
| 1 | Conductor | Fine stranded tinned copper wires |
| 2 | Conductor smoothing | Conductive rubber layer |
| 3 | Insulation | Heat-resistant 3GI3 rubber compound on EPR basis |
| 4 | Field limiting | Outer conductive rubber layer |
| 5 | Earth conductor | Spiral of tinned copper wires over the outer semi-conductive layer of the cores |
| 6 | Pilot cores | Flexible design with coloured EPR (3GI3) insulation |
| 7 | Lay-up | Cores laid up with the pilot cores in the outer interstices |
| 8 | Wrapping | Film wrapping |
| 9 | Inner sheath | GM1b rubber compound of high mechanical strength |
| 10 | Monitoring shield | Conductive rubberized textile tape and a spiral of copper and steel wires |
| 11 | Intermediate sheath | GM1b rubber compound of high mechanical strength |
| 12 | Armour | Braided armour of galvanised steel wires, also forming an external earthed shield |
| 13 | Outer sheath | Chlorinated rubber compound 5GM5, red, abrasion- and tear-resistant, oil-resistant, flame retardant |
Designation elements
3E denotes the three-part earth arrangement, ST a control core and ÜL the monitoring conductor. A build written 3 × 25 + 3 × 16/3E + 3 × 2.5 ST + ÜL therefore has three 25 mm² phase cores, a 16 mm² earth in three parts, three 2.5 mm² control cores and one monitoring conductor.
Supply form
The cables are supplied in matched lengths, typically 100 m or 200 m, with both ends fitted with terminations adapted to the entry fitting of the high-voltage connection box. Termination type and entry fitting must be stated with the enquiry, since they are made to the box, not to the cable alone.
NTSCGECCWOEU Applications
NTSCGECCWOEU connects electrical equipment in mines and underground excavations with hazardous environments, under particularly high mechanical loads. The typical case is a high-voltage transformer on an underground mining or tunnelling power line, where the cable must stay live and monitored while equipment is repositioned.

- High-voltage transformers on underground mine and tunnel power lines.
- Routes where mechanical protection beyond an unarmoured trailing cable is required.
- Installations needing an earthed external metallic shield in addition to the monitoring shield.
- Equipment that must be moved while running, within the stated bending limits.
Application boundaries
The flexibility of the cable allows operating equipment to be moved while running. It is a trailing construction rather than a high-speed reeling cable, and the terminations are built to the high-voltage connection box on the equipment, so the box type and entry fitting are stated with the order.
Related monitored medium-voltage references
Compare (N)TSCGECWÖU TBM cable, the unarmoured build of the same family, and (N)TSCGECECWÖU TBM reeling cable, which uses a different monitoring and earth arrangement at 8.7/15 and 12/20 kV.
Reference note: enquiries arriving marked TENAX-HP or NTSCGECCWÖU are handled on this page; TEBAOFLEX manufactures to the designation and construction shown, and is not affiliated with the trademark holder.
Reference designation cross-reference
This armoured monitored cable is catalogued under a reference name of its own, and it is the armoured counterpart of the unarmoured monitored build.
| Reference designation | TEBAOFLEX designation and build | Rated voltage | What the reference name marks |
|---|---|---|---|
| TENAX-HP / NTSCGECCWOEU | NTSCGECCWOEU armoured monitored mining cable | 3.6/6 and 6/10 kV | The tinned steel wire braid armour is what the P marks |
| TENAX-H / NTSCGECWOEU | (N)TSCGECWÖU monitored TBM reeling cable | 3.6/6 to 18/30 kV | The same monitoring concept without the armour; see the TBM page |
For the counterpart construction see (N)TSCGECWÖU monitored TBM cable.
For the full list of reference designations and the TEBAOFLEX build each one maps to, see the mining cable designation cross-reference.
Trademark note: TENAX®, TROMMELFLEX®, FELTOFLEX® and SCHRÄM® are trademarks of their respective owners, and TEBAOFLEX is neither affiliated with those companies nor reselling their cable. What we supply is the equivalent construction: we manufacture to the same VDE type designation and published construction, and every designation listed here can be quoted and supplied as a TEBAOFLEX build. The names appear so that an enquiry written in those terms reaches the matching construction, which is made to the standards and construction confirmed for the order.
NTSCGECCWOEU Specifications
| Rated voltage U₀/U | 3.6/6 kV and 6/10 kV |
|---|---|
| Standard | DIN VDE 0250 Part 813 |
| Cable-surface temperature, static | -40 °C to +80 °C |
| Cable-surface temperature, flexing | -25 °C to +80 °C |
| Minimum bending radius, static | 4 × D |
| Minimum bending radius, mobile application | 7.5 × D |
| Outer sheath colour | Red |
| Standard supply length | Matched lengths of 100 m or 200 m with terminations fitted |
| Diameter notation | D = cable diameter |
NTSCGECCWOEU 3.6/6 kV size table
| Code and cross-section | Outer diameter approx. | Weight approx. | Inductive resistance at 50 Hz | Conductor-earth capacitance |
|---|---|---|---|---|
| NTSCGECCWOEU 3.6/6 kV 3 × 25 + 3 × 16/3E + 3 × 2.5 ST + ÜL | 58-63 mm | 4920 kg/km | 0.121 Ω/km | 0.34 µF/km |
| NTSCGECCWOEU 3.6/6 kV 3 × 35 + 3 × 16/3E + 3 × 2.5 ST + ÜL | 60-66 mm | 5540 kg/km | 0.115 Ω/km | 0.38 µF/km |
| NTSCGECCWOEU 3.6/6 kV 3 × 50 + 3 × 25/3E + 3 × 2.5 ST + ÜL | 65-71 mm | 6580 kg/km | 0.109 Ω/km | 0.42 µF/km |
| NTSCGECCWOEU 3.6/6 kV 3 × 70 + 3 × 35/3E + 3 × 2.5 ST + ÜL | 69-75 mm | 7750 kg/km | 0.103 Ω/km | 0.48 µF/km |
| NTSCGECCWOEU 3.6/6 kV 3 × 95 + 3 × 50/3E + 3 × 2.5 ST + ÜL | 75-82 mm | 9250 kg/km | 0.099 Ω/km | 0.53 µF/km |
NTSCGECCWOEU 6/10 kV size table
| Code and cross-section | Outer diameter approx. | Weight approx. | Inductive resistance at 50 Hz | Conductor-earth capacitance |
|---|---|---|---|---|
| NTSCGECCWOEU 6/10 kV 3 × 25 + 3 × 16/3E + 3 × 2.5 ST + ÜL | 59-64 mm | 5140 kg/km | 0.124 Ω/km | 0.31 µF/km |
| NTSCGECCWOEU 6/10 kV 3 × 35 + 3 × 16/3E + 3 × 2.5 ST + ÜL | 63-69 mm | 5900 kg/km | 0.118 Ω/km | 0.34 µF/km |
| NTSCGECCWOEU 6/10 kV 3 × 50 + 3 × 25/3E + 3 × 2.5 ST + ÜL | 66-72 mm | 6810 kg/km | 0.111 Ω/km | 0.38 µF/km |
All listed builds are available to order. The 6/10 kV range is offered to 3 × 50 mm²; larger sizes at that voltage are quoted against the project drawing. Dimensions and weights are nominal values.
NTSCGECCWOEU Standards, Approvals and Order Documentation
| Reference | Scope | Order confirmation |
|---|---|---|
| DIN VDE 0250 Part 813 | Rubber-insulated flexible cables, medium-voltage series | State the required edition with the full designation. |
| DIN VDE 0207 Part 20 | 3GI3 EPR insulating compound | Insulation compound type is fixed at 3GI3. |
| DIN VDE 0207 Part 21 | 5GM5 chlorinated rubber sheathing compound | Sheath compound type is fixed at 5GM5. |
Approvals
| Approval | Status |
|---|---|
| Manufacturing conformity, DIN VDE 0250 Part 813 | Held |
| Use in mines and underground excavations with hazardous environments | Held |
| Medium-voltage routine electrical and partial discharge test package | Held |
Order package
State the rated voltage, phase and earth cross-sections, control and monitoring core requirement, the transformer or equipment connection box and its entry fitting, required matched lengths, the protection and monitoring circuit in use, and any project inspection or documentation scope.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
(N)TSCGECWÖU - TBM Medium Voltage Cable for Tunnel Boring Machines
A related cable option for a different application or duty profile.
View product(N)TSCGECECWÖU 8.7/15kV 12/20kV TBM Reeling Cable
A related cable option for a different application or duty profile.
View productNTSCGEWOEU / (N)TSCGEWÖU Medium Voltage Crane Reeling Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.