NTSCGECCWOEU Armoured Monitored Mining Cable 3.6/6-6/10kV

NTSCGECCWOEU 3.6/6 kV and 6/10 kV armoured monitored mining cable to DIN VDE 0250 Part 813, for high-voltage equipment on mine and tunnel power lines under particularly high mechanical loads.

  • Conductor: fine stranded tinned copper with conductive rubber smoothing layer.
  • Insulation: heat-resistant 3GI3 EPR compound with outer field-limiting layer.
  • Monitoring shield: conductive rubberized textile tape and copper-steel spiral.
  • Armour: braided galvanised steel wires forming an earthed external shield.
  • Outer sheath: red chlorinated rubber 5GM5.

Send voltage, machine or transformer data, route and termination requirements for RFQ review.

Product information
Brand
TEBAOFLEX
Product overview

NTSCGECCWOEU Armoured Monitored Mining Cable

NTSCGECCWOEU is a medium-voltage trailing cable to DIN VDE 0250 Part 813 with a monitoring shield and, as its defining feature, a braided armour of galvanised steel wires fitted below the outer sheath. That armour is the difference between this designation and the otherwise similar NTSCGECWOEU: it takes particularly high mechanical loads and at the same time forms an external earthed shield.

The letter sequence matters. NTSCGECCWOEU carries two C positions and is armoured; NTSCGECWOEU has one and is not; NTSCGECECWÖU is a different monitoring construction again. These are separate cables, not spelling variants of each other, and substituting one for another on a transformer feed is a real failure mode.

  • Rated voltage: 3.6/6 kV and 6/10 kV.
  • Armour: braided galvanised steel wires, also acting as an earthed external shield.
  • Bending radius: 4 × D static, 7.5 × D mobile.
  • Monitoring: conductive rubberized textile tape plus a copper-steel spiral shield.

The phase-concentric earth conductor and the common concentric monitoring shield, used with a high-voltage protection circuit, allow the cable to be monitored for insulation faults and for damage from external influences. For the unarmoured build see (N)TSCGECWÖU TBM cable; for the separate-earth monitoring construction see (N)TSCGECECWÖU.

Construction

NTSCGECCWOEU Cable Construction

The layer sequence below is the armoured build. Positions 1 to 11 are shared with the unarmoured construction; position 12, the galvanised steel wire braid, is what makes this NTSCGECCWOEU.

NTSCGECCWOEU cross-section showing screened power cores, copper-steel monitoring spiral and galvanised steel wire braid armour
Flat cross-section of the NTSCGECCWOEU armoured monitored mining cable.
NTSCGECCWOEU armoured monitored cable construction
No.LayerConstruction
1ConductorFine stranded tinned copper wires
2Conductor smoothingConductive rubber layer
3InsulationHeat-resistant 3GI3 rubber compound on EPR basis
4Field limitingOuter conductive rubber layer
5Earth conductorSpiral of tinned copper wires over the outer semi-conductive layer of the cores
6Pilot coresFlexible design with coloured EPR (3GI3) insulation
7Lay-upCores laid up with the pilot cores in the outer interstices
8WrappingFilm wrapping
9Inner sheathGM1b rubber compound of high mechanical strength
10Monitoring shieldConductive rubberized textile tape and a spiral of copper and steel wires
11Intermediate sheathGM1b rubber compound of high mechanical strength
12ArmourBraided armour of galvanised steel wires, also forming an external earthed shield
13Outer sheathChlorinated rubber compound 5GM5, red, abrasion- and tear-resistant, oil-resistant, flame retardant

Designation elements

3E denotes the three-part earth arrangement, ST a control core and ÜL the monitoring conductor. A build written 3 × 25 + 3 × 16/3E + 3 × 2.5 ST + ÜL therefore has three 25 mm² phase cores, a 16 mm² earth in three parts, three 2.5 mm² control cores and one monitoring conductor.

Supply form

The cables are supplied in matched lengths, typically 100 m or 200 m, with both ends fitted with terminations adapted to the entry fitting of the high-voltage connection box. Termination type and entry fitting must be stated with the enquiry, since they are made to the box, not to the cable alone.

Applications

NTSCGECCWOEU Applications

NTSCGECCWOEU connects electrical equipment in mines and underground excavations with hazardous environments, under particularly high mechanical loads. The typical case is a high-voltage transformer on an underground mining or tunnelling power line, where the cable must stay live and monitored while equipment is repositioned.

Underground mine power line with a mobile high-voltage transformer connected by the armoured cable
NTSCGECCWOEU connecting a mobile high-voltage transformer underground.
  • High-voltage transformers on underground mine and tunnel power lines.
  • Routes where mechanical protection beyond an unarmoured trailing cable is required.
  • Installations needing an earthed external metallic shield in addition to the monitoring shield.
  • Equipment that must be moved while running, within the stated bending limits.

Application boundaries

The flexibility of the cable allows operating equipment to be moved while running. It is a trailing construction rather than a high-speed reeling cable, and the terminations are built to the high-voltage connection box on the equipment, so the box type and entry fitting are stated with the order.

Related monitored medium-voltage references

Compare (N)TSCGECWÖU TBM cable, the unarmoured build of the same family, and (N)TSCGECECWÖU TBM reeling cable, which uses a different monitoring and earth arrangement at 8.7/15 and 12/20 kV.

Reference note: enquiries arriving marked TENAX-HP or NTSCGECCWÖU are handled on this page; TEBAOFLEX manufactures to the designation and construction shown, and is not affiliated with the trademark holder.

Reference designation cross-reference

This armoured monitored cable is catalogued under a reference name of its own, and it is the armoured counterpart of the unarmoured monitored build.

Reference designation cross-reference
Reference designationTEBAOFLEX designation and buildRated voltageWhat the reference name marks
TENAX-HP / NTSCGECCWOEUNTSCGECCWOEU armoured monitored mining cable3.6/6 and 6/10 kVThe tinned steel wire braid armour is what the P marks
TENAX-H / NTSCGECWOEU(N)TSCGECWÖU monitored TBM reeling cable3.6/6 to 18/30 kVThe same monitoring concept without the armour; see the TBM page

For the counterpart construction see (N)TSCGECWÖU monitored TBM cable.

For the full list of reference designations and the TEBAOFLEX build each one maps to, see the mining cable designation cross-reference.

Trademark note: TENAX®, TROMMELFLEX®, FELTOFLEX® and SCHRÄM® are trademarks of their respective owners, and TEBAOFLEX is neither affiliated with those companies nor reselling their cable. What we supply is the equivalent construction: we manufacture to the same VDE type designation and published construction, and every designation listed here can be quoted and supplied as a TEBAOFLEX build. The names appear so that an enquiry written in those terms reaches the matching construction, which is made to the standards and construction confirmed for the order.

Specifications

NTSCGECCWOEU Specifications

NTSCGECCWOEU operating data
Rated voltage U₀/U3.6/6 kV and 6/10 kV
StandardDIN VDE 0250 Part 813
Cable-surface temperature, static-40 °C to +80 °C
Cable-surface temperature, flexing-25 °C to +80 °C
Minimum bending radius, static4 × D
Minimum bending radius, mobile application7.5 × D
Outer sheath colourRed
Standard supply lengthMatched lengths of 100 m or 200 m with terminations fitted
Diameter notationD = cable diameter

NTSCGECCWOEU 3.6/6 kV size table

Code and cross-sectionOuter diameter approx.Weight approx.Inductive resistance at 50 HzConductor-earth capacitance
NTSCGECCWOEU 3.6/6 kV 3 × 25 + 3 × 16/3E + 3 × 2.5 ST + ÜL58-63 mm4920 kg/km0.121 Ω/km0.34 µF/km
NTSCGECCWOEU 3.6/6 kV 3 × 35 + 3 × 16/3E + 3 × 2.5 ST + ÜL60-66 mm5540 kg/km0.115 Ω/km0.38 µF/km
NTSCGECCWOEU 3.6/6 kV 3 × 50 + 3 × 25/3E + 3 × 2.5 ST + ÜL65-71 mm6580 kg/km0.109 Ω/km0.42 µF/km
NTSCGECCWOEU 3.6/6 kV 3 × 70 + 3 × 35/3E + 3 × 2.5 ST + ÜL69-75 mm7750 kg/km0.103 Ω/km0.48 µF/km
NTSCGECCWOEU 3.6/6 kV 3 × 95 + 3 × 50/3E + 3 × 2.5 ST + ÜL75-82 mm9250 kg/km0.099 Ω/km0.53 µF/km

NTSCGECCWOEU 6/10 kV size table

Code and cross-sectionOuter diameter approx.Weight approx.Inductive resistance at 50 HzConductor-earth capacitance
NTSCGECCWOEU 6/10 kV 3 × 25 + 3 × 16/3E + 3 × 2.5 ST + ÜL59-64 mm5140 kg/km0.124 Ω/km0.31 µF/km
NTSCGECCWOEU 6/10 kV 3 × 35 + 3 × 16/3E + 3 × 2.5 ST + ÜL63-69 mm5900 kg/km0.118 Ω/km0.34 µF/km
NTSCGECCWOEU 6/10 kV 3 × 50 + 3 × 25/3E + 3 × 2.5 ST + ÜL66-72 mm6810 kg/km0.111 Ω/km0.38 µF/km

All listed builds are available to order. The 6/10 kV range is offered to 3 × 50 mm²; larger sizes at that voltage are quoted against the project drawing. Dimensions and weights are nominal values.

Standards

NTSCGECCWOEU Standards, Approvals and Order Documentation

Standards applied
ReferenceScopeOrder confirmation
DIN VDE 0250 Part 813Rubber-insulated flexible cables, medium-voltage seriesState the required edition with the full designation.
DIN VDE 0207 Part 203GI3 EPR insulating compoundInsulation compound type is fixed at 3GI3.
DIN VDE 0207 Part 215GM5 chlorinated rubber sheathing compoundSheath compound type is fixed at 5GM5.

Approvals

Certification held for this construction
ApprovalStatus
Manufacturing conformity, DIN VDE 0250 Part 813Held
Use in mines and underground excavations with hazardous environmentsHeld
Medium-voltage routine electrical and partial discharge test packageHeld

Order package

State the rated voltage, phase and earth cross-sections, control and monitoring core requirement, the transformer or equipment connection box and its entry fitting, required matched lengths, the protection and monitoring circuit in use, and any project inspection or documentation scope.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.