(N)TMCHXOEU 12/20 kV LSOH Single-Core Wind Turbine Cable

(N)TMCHXOEU 12/20 kV single-core LSOH wind turbine cable reference with Class 5 bare copper, EPR-3GI3 insulation, a spiral tinned-copper screen and black HXM1 rubber sheath.

Product information
Product overview

(N)TMCHXOEU 12/20 kV is a single-core screened cable designation for wind-turbine medium-voltage connections subject to medium mechanical stress. The supplied reference shows three single-core sizes rather than a multicore tower cable. Use it when the electrical design calls for a separate phase cable and the routing, support and screen-bonding arrangement are defined at system level.

Its catalogue construction pairs fine-stranded Class 5 bare copper with EPR-3GI3 rubber insulation, inner and outer semiconductive field-control layers, a spiral layer of tinned-copper screen wires and a black vulcanized HXM1 outer sheath. The source identifies the series as low-smoke, zero-halogen (LSOH) and gives a fixed-installation ambient range of −40°C to +80°C; for fully flexible operation, the lower ambient bound is −25°C. The size table reports minimum bend radius separately for fixed and free-moving service.

Specify the voltage, phase size, screen cross-section, single-core arrangement, bonding design, cable support and movement before asking for a quotation. The source-listed 1×50/16, 1×120/16 and 1×150/25 mm² configurations are separate from the multicore (N)TSCGEHXOEU wind turbine cable. If the turbine requires 36/60–69 kV, review the high-voltage model instead. The industrial cable range gives the wider selection context.

Construction

Construction

The single-core design uses a fine-stranded bare-copper conductor and EPR-3GI3 rubber insulation between semiconductive field-control layers. A spiral tinned-copper-wire screen surrounds the insulated core, and a black HXM1 vulcanized rubber outer sheath completes the reference construction.

PropertySource catalogue reference
ConductorBare copper, fine-stranded Class 5 to IEC 60228 / DIN EN 60228
InsulationEPR-3GI3 rubber compound
Electrical field controlInner and outer semiconductive rubber layers
Metallic screenSpiral tinned-copper wire layer
Outer sheathBlack vulcanized HXM1 rubber compound
FormSingle-core; screen size included after slash in catalogue configuration
(N)TMCHXOEU 12/20 kV single-core wind cable construction cross-section showing the conductor and layers
(N)TMCHXOEU 12/20 kV LSOH Single-Core Wind Turbine Cable construction illustration; verify the ordered build against its approved drawing.
Applications

Applications

The source places (N)TMCHXOEU in wind turbines under medium mechanical stress. Size the cable for the voltage and current, then check the route for fixed or moving service: the supplied lower ambient limit is −40°C when fixed and −25°C when fully flexible. Cable cleats, screen bonding and terminations should be engineered as a single-core system.

How does it differ from (N)TSCGEHXOEU?

This (N)TMCHXOEU reference is single-core with a spiral tinned-copper screen and EPR-3GI3 insulation. The (N)TSCGEHXOEU medium-voltage wind page carries three-core and 3+3 catalogue configurations with HEPR and a different size table. Select by circuit layout and cable formation before comparing diameters or ampacities.

(N)TMCHXOEU 12/20 kV single-core wind cable, single-core medium-voltage cable routed inside a wind-turbine tower
Illustrative application setting for (N)TMCHXOEU 12/20 kV LSOH Single-Core Wind Turbine Cable; final cable route and terminations depend on the equipment design.
Specifications

Specifications

PropertySource catalogue reference
Type designation(N)TMCHXOEU
Rated voltage12/20 kV
Maximum permissible operating voltageAC 13.9/24 kV; DC 18/36 kV
AC test voltage29 kV in supplied reference
Maximum conductor / short-circuit temperature90°C / 250°C
Ambient temperature, fixed−40°C to +80°C
Ambient temperature, fully flexible−25°C to +80°C
Maximum tensile load on conductor15 N/mm²
Reference torsional stress±100°/m
(N)TMCHXOEU 12/20 kV single-core catalogue configurations
Model + source configurationInsulation nom. (mm)OD min–max (mm)Bend min. fixed / moving (mm)Approx. weight (kg/km)Tensile max (N)Conductor R20 max (Ω/km)Capacitance (µF/km)Ampacity (A)1 s short-circuit (kA)
(N)TMCHXOEU 12/20 kV 1×50/16 mm²5.527–30150 / 3001 4407500.3860.242757.15
(N)TMCHXOEU 12/20 kV 1×120/16 mm²5.536.4–38.9233.4 / 3892 3501 8000.1640.2850517.16
(N)TMCHXOEU 12/20 kV 1×150/25 mm²5.536–40248.4 / 4142 7302 2500.1320.2958221.45

The source defines current ratings for three loaded conductors, spaced. Confirm installation, grouping, bonding and thermal correction factors for the actual circuit. Values are catalogue references pending the order-specific production drawing.

Standards

Standards

The supplied (N)TMCHXOEU reference lists DIN VDE 0250-813 as the product design standard and IEC 60228 / DIN EN 60228 for the Class 5 conductor. It lists HXM1 sheath material to DIN VDE 0266. Specify the exact acceptance tests and documentation in the project technical schedule.

PropertySource catalogue reference
Flame propagationIEC 60332-1-2 referenced
Oil resistanceEN 60811-404 test reference
Ozone resistanceDIN EN 50396, clause 8.1.3 referenced
Bend selectionDIN VDE 0298 Part 3 referenced; size values in Specifications
LSOH descriptionLSOH construction: request smoke-density and halogen-acidity test reports for the ordered cable
Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.