Get a Quote
Submersible Pump Cables TEBAOFLEX

Flygt SUBCAB MAS 800 Enquiry — Composite Pump Cable Specification Review — TEBAOFLEX

TEBAOFLEX specification review for Flygt SUBCAB cable enquiries involving the MAS 800 pump-monitoring system. Match motor cores, screened twisted sensor pairs, VFD screen, cable-entry seal and wet-duty requirements from the actual pump drawing.

Product information
Brand
TEBAOFLEX
Product overview

Flygt SUBCAB MAS 800 cable specification review

A buyer asking for a Flygt SUBCAB MAS 800 cable usually needs a composite submersible pump motor cable that carries both power and monitoring signals. MAS 800 is Flygt’s pump supervision system, not a unique cable part number in the supplied brochure. Within the SUBCAB family, Flygt describes screened, twisted-pair control elements adapted for that system. TEBAOFLEX can evaluate a replacement enquiry against the pump and cable documentation, then quote a defined construction under its own brand.

The replacement decision depends on more than matching conductor size. The monitoring cores must land on the correct terminals and retain the intended screening arrangement. A VFD pump may also require a screen around the power circuit. At the pump entry, the finished cable diameter and sheath compression must suit the seal sleeve; a near-match in core count can still fail the sealing check. The three SUBCAB sections shown in the source document are examples of different power and control layouts, not three confirmed MAS 800-specific cable SKUs.

Send the pump model and serial details, the original cable marking or Flygt part number, the wiring diagram, starting method, installed cable outside diameter, gland/sleeve size, immersion depth and fluid temperature. For general composite pump cable searches without an MAS 800 interface requirement, see the existing SUBCAB-style pump cable page.

How a 6/10 kV replacement cable manufactured by Jiangsu TEBAOFLEX for a Xylem Flygt pump with a 6000 V motor was specified, including its screened control pairs, the 54 mm cable-entry limit and the wording agreed for the quotation, is described on the medium-voltage submersible pump cable replacement case page.

Construction

Construction

The Flygt source illustrates several original SUBCAB layouts rather than one MAS 800 cable cross-section. They combine copper motor conductors, EPR or HEPR-insulated cores, control elements and, in selected designs, a screened control pair and a larger power-cable screen. The brochure describes a CPE outer sheath for its original product range. A TEBAOFLEX replacement must be drawn around the actual pump circuit and entry seal.

Flygt SUBCAB source construction examples for MAS 800 interface review
Interface elementOriginal source exampleDrawing check for a TEBAOFLEX quotation
Motor cores7G2.5, 4G10 or larger screened power arrangement shown as different examplesMotor current, phase/starting method, earth/PE design and insulation
Monitoring pairT1–T2 pair; shielded/twisted construction shown for 4G10 + S(2 × 0.5)Pair count, conductor gauge, screen/drain termination and MAS 800 wiring
Power screenShown on a separate large screened SUBCAB exampleVFD requirement and screen earthing scheme
Outer sheath and sealOriginal SUBCAB family describes CPE outer sheath and controlled diameterMeasured outside diameter, entry sleeve compression and wet-duty material
Illustrative composite pump cable section with power and monitoring elements
Illustrative reference construction; confirm layer details and dimensions against the approved drawing.
Applications

Applications

This page is for pump operators and OEM buyers who need to cross-check a SUBCAB composite cable against a Flygt pump fitted with MAS 800 supervision. The key task is to preserve the monitored signals while supplying the motor and maintaining the pump-entry seal. It is not a promise of plug-and-play compatibility.

  • Verify which pump sensors report to MAS 800, and obtain the original terminal and colour identification.
  • State whether the drive is direct-on-line, star-delta or VFD; the power-core and screening routes differ.
  • Confirm permanent immersion, water chemistry, temperature, depth and cable support or clamping.
  • Match finished outside diameter and jacket properties to the actual cable-entry sleeve and pressure seal.

The source brochure's performance and approvals concern genuine Flygt parts. The replacement quotation needs its own evidence for the selected pump and installation.

Illustrative composite cable entering a submersible pump through a cable gland
Illustrative application setting; confirm routing and installation conditions for the project.
Specifications

Specifications

Flygt MAS 800 is a pump supervision system. The supplied Flygt document does not provide a single cable ordering code called “MAS 800 cable”; it describes a SUBCAB range with some screened, twisted-pair monitoring constructions adapted for that system. The following are original Flygt references for identifying an existing cable, not TEBAOFLEX product ratings.

Original Flygt SUBCAB brochure illustrations; none is identified as a universal MAS 800 cable
Original SUBCAB illustrated markingWhat the source illustration establishesMAS 800 matching task
SUBCAB 7G2.5 + 2 × 1.5Seven power/ground cores with two T1–T2 control cores; EPR insulation shownConfirm whether this unscreened control-core layout matches the actual pump and monitor
SUBCAB 4G10 + S(2 × 0.5)Four power/ground cores and a screened T1–T2 control element; HEPR insulation and an inset with copper screen/drain wire shownCheck signal-pair screening, terminal assignment and cable-entry sleeve
SUBCAB S3 × 70 + 3 × 25/3 + S2(2 × 0.5)Screened power-cable section and control element marked T1–T4 in the illustrationConfirm complete pump drawing, each circuit, overall screen and gland geometry
Flygt SUBCAB original range data for comparison, not TEBAOFLEX specifications
Source-family referenceFlygt brochure statement
Screened SUBCAB voltage classes600/1000 V for Europe; 600 V for CSA/UL versions
Insulation familyEPR/HEPR 3GI3 described for selected constructions; 90°C material rating
Outer sheathCPE, VDE/5GM5 type described for original SUBCAB family
Wet-service catalogue envelopeUp to 70°C water, 50 m water depth and pH 3–10 are original-family brochure claims, not universal per-size MAS 800 values
VFD optionScreened SUBCAB versions are listed for VFD duty; monitor pairs remain a separate circuit-compatibility check

For a TEBAOFLEX quotation, identify the installed Flygt pump and cable marking, motor voltage/current, start method or VFD, power-core layout, screened-pair count and gauge, T1–T4 terminal assignments, cable outside diameter, entry-seal sleeve, immersion conditions and required approvals.

Standards

Standards

The supplied Flygt brochure cites standards and approvals for the original SUBCAB assortment, not for a single MAS 800 cable part number. A TEBAOFLEX quotation must state the exact tests and approvals required for the offered cable and pump installation.

Flygt SUBCAB source standards and approvals; not assigned to TEBAOFLEX
Original Flygt brochure referenceStated scope
IEC 60228 Class 5Conductor reference in original assortment
EN 50525-2-21 / VDE 0298-300Original brochure references for submersible/wet-use cable
IEC 60811-1-1 / VDE 0472Original materials and oil-test references
IEC 60332-1 / IEC 60332-2Original flame-test references
FM / INERISOriginal Flygt pump-and-cable application approval statements
CSA / CCC / VDEOriginal assortment approval and standards references
Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.