MCP & MCPTJ Coal Cutter and Shearer Screened Flexible Cable (0.66/1.14–1.9/3.3 kV)
Heavy-duty screened flexible coal cutter and longwall shearer cables (MCP 0.66/1.14 kV, MCPTJ 0.66/1.14 kV, MCP 1.9/3.3 kV and MCPTJ 1.9/3.3 kV) designed and manufactured to MT/T 818.2, MT/T 818.3 and MT/T 818.4 (GB/T 12972 series). Combines three screened Class 5 power cores, an interstitial earth conductor and a jacketed multi-core control/monitoring unit for continuous flexing inside armoured face conveyor cable handler chains.
MCP and MCPTJ coal cutter and shearer cables provide combined traction/cutter power, earth-fault protection and multi-core pilot control for longwall drum shearers moving back and forth along armoured face conveyors (AFC). Built to MT/T 818.2-2009, MT/T 818.3-2009 and MT/T 818.4-2009 (GB/T 12972.2–12972.4), the cable integrates three screened power cores (16 mm² to 150 mm²), one interstitial grounding conductor and a dedicated multi-core control sub-assembly (typically 4 × 4 mm² or 4 × 6 mm²) within a torsion-balanced round profile.
Type MCP uses extruded semiconductive elastomer screens over each +90 °C EPR-insulated power core for 0.66/1.14 kV and 1.9/3.3 kV shearer systems, whereas Type MCPTJ incorporates a tinned-copper wire and synthetic-yarn composite metallic phase screen plus pilot monitoring cores (J) for enhanced ground-fault sensitivity and interlock protection on high-output longwall faces.
To survive thousands of reverse-bending cycles inside Bretby-type shearer cable handler chains, the cabled core assembly is cushioned by a semiconductive elastomeric center cradle, bound with anti-torsion reinforcing braid and protected by a high-tear-strength flame-retardant polychloroprene (PCP) outer jacket.
State the required model (MCP or MCPTJ), rated voltage (0.66/1.14 kV or 1.9/3.3 kV), power and control core cross-sections, and shearer cable handler chain inner dimensions when requesting a quote. TEBAOFLEX supplies custom shearer cable lengths from a 50 m minimum order quantity with a standard lead time of 7–45 working days.
Explore the mining and tunneling cable range for related configurations.
For general underground coal face trailing cables and DIN VDE 0.6/1 kV coal cutter cables, compare these specifications: MYP & MYPT Screened Flexible Coal Mining Cable (0.38/0.66–1.9/3.3 kV) (for 0.38/0.66 kV to 1.9/3.3 kV mobile underground drills, shuttle cars, and auxiliary face equipment); NSSHKCGEOEU 0.6/1kV Coal Cutter Trailing Cable (for VDE 0.6/1 kV coal cutter trailing service with individual core screens and high tear resistance). Verify power core cross-section, pilot bundle core count, and monitoring circuit type (MCP vs MCPTJ) before ordering.
Construction
The representative construction illustrates MCPTJ 1.9/3.3 kV 3×95 + 1×35 + 4×6 mm²: three equal Class 5 flexible tinned-copper power cores with +90 °C EPR insulation and composite metallic screens, one uninsulated flexible tinned-copper earth core in the lower interstitial valley, and one round jacketed four-core control sub-assembly (4 × 6 mm²) in the upper interstitial valley, cabled around a central profile cradle and enclosed in a braid-reinforced black flame-retardant rubber outer jacket.

| Component | Material and construction |
|---|---|
| Power conductors | Three extra-flexible Class 5 rope-lay stranded tinned or annealed copper conductors per GB/T 3956 / IEC 60228 (16 mm² to 150 mm²). |
| Power core insulation | +90 °C ethylene-propylene rubber (EPR / XJ-30A) engineered for high dielectric strength and thermal stability under cyclic shearer cutter loads. |
| Individual phase screen | MCP: semiconductive elastomer screen over each power core. MCPTJ: semiconductive elastomer layer plus tinned-copper wire and polyester-yarn composite metallic shield. |
| Control & monitoring unit | Round elastomeric-jacketed control sub-assembly cabled in the upper interstice containing four insulated flexible control/pilot conductors (4 × 4 mm² or 4 × 6 mm²). |
| Earth / grounding conductor | One flexible stranded tinned-copper grounding conductor (10 mm² to 50 mm²) positioned in the opposite interstitial valley. |
| Anti-torsion reinforcement & jacket | Elastomeric inner bedding, open-weave synthetic anti-torsion braid and heavy-duty flame-retardant polychloroprene (PCP / XH-03A) outer sheath. |
Applications
Size the power cores for the combined cutter-motor and haulage-drive load, and verify that the cable outside diameter fits freely inside the longwall shearer cable handler troughs.

- 0.66/1.14 kV MCP and MCPTJ longwall drum shearer trailing cables guided in Bretby-type articulated cable handler chains.
- 1.9/3.3 kV MCP and MCPTJ high-power longwall coal cutter cables for medium- and thick-seam automated longwall faces.
- Combined power, haulage control, emergency-stop interlock and pilot earth-continuity monitoring in a single round shearer cable.
- Continuous reverse bending along the armoured face conveyor pan line at a minimum dynamic bending radius of 6 × D (0.66/1.14 kV) to 10 × D (1.9/3.3 kV).
When engineering longwall shearer cable handler chains and medium-voltage cutter feeds, review these pages: Mining Cable Solutions for Mobile Equipment and Tunneling (for underground longwall, room-and-pillar, and TBM tunneling cable system engineering); NTSKCGECWOEU 1.8/3–3.6/6 kV Coal Cutter Chain Cable (for 1.8/3 kV and 3.6/6 kV VDE coal cutter chain cables on high-output longwall faces). Confirm Bretby chain inner trough width, minimum dynamic bend radius, and axial tensile load.
Specifications
| Parameter | Value |
|---|---|
| Rated voltage (U0/U) | 0.66/1.14 kV and 1.9/3.3 kV |
| Maximum continuous conductor temperature | +90 °C (+250 °C short-circuit, 5 s max.) |
| Core configuration | 3 screened power cores + 1 interstitial earth core + 4-core jacketed control/monitoring unit |
| Control core rated voltage | 250 V AC control & pilot monitoring circuit (4 × 4 mm² or 4 × 6 mm²) |
| Power frequency AC test voltage | 3.5 kV / 5 min (0.66/1.14 kV power cores); 6.5 kV / 5 min (1.9/3.3 kV power cores); 2.0 kV / 5 min (control cores) |
| Minimum dynamic bending radius | 6 × cable outside diameter (0.66/1.14 kV); 10 × cable outside diameter (1.9/3.3 kV) |
| Flame retardancy | Complies with single and bundled vertical flame tests per MT 386 |
| Commercial supply terms | Minimum order quantity 50 m; manufacturing lead time 7–45 working days |
| Model & voltage rating | Nominal cross-section (power + earth + control, mm²) | Power insulation thickness (mm) | Nominal outside diameter min–max (mm) | Max. power DC resistance at 20 °C (Ω/km) | Continuous ampacity at 25 °C ambient (A) | Approx. weight (kg/km) |
|---|---|---|---|---|---|---|
| MCP / MCPTJ-0.66/1.14 kV | 3×16 + 1×10 + 4×4 | 1.8 | 34.5 – 38.2 | 1.21 | 85 | 1,720 |
| MCP / MCPTJ-0.66/1.14 kV | 3×25 + 1×16 + 4×4 | 2.0 | 38.0 – 42.1 | 0.780 | 113 | 2,240 |
| MCP / MCPTJ-0.66/1.14 kV | 3×35 + 1×16 + 4×4 | 2.0 | 40.6 – 45.0 | 0.554 | 138 | 2,690 |
| MCP / MCPTJ-0.66/1.14 kV | 3×50 + 1×16 + 4×4 | 2.2 | 45.2 – 49.8 | 0.386 | 173 | 3,480 |
| MCP / MCPTJ-0.66/1.14 kV | 3×70 + 1×25 + 4×6 | 2.2 | 50.4 – 55.4 | 0.272 | 215 | 4,560 |
| MCP / MCPTJ-0.66/1.14 kV | 3×95 + 1×35 + 4×6 | 2.4 | 55.8 – 61.2 | 0.206 | 260 | 5,780 |
| MCP / MCPTJ-0.66/1.14 kV | 3×120 + 1×35 + 4×6 | 2.4 | 59.6 – 65.4 | 0.161 | 300 | 6,890 |
| MCP / MCPTJ-1.9/3.3 kV | 3×35 + 1×16 + 4×4 | 3.4 | 47.8 – 52.8 | 0.554 | 138 | 3,420 |
| MCP / MCPTJ-1.9/3.3 kV | 3×50 + 1×16 + 4×4 | 3.4 | 51.6 – 56.9 | 0.386 | 173 | 4,180 |
| MCP / MCPTJ-1.9/3.3 kV | 3×70 + 1×25 + 4×6 | 3.4 | 56.4 – 62.1 | 0.272 | 215 | 5,290 |
| MCP / MCPTJ-1.9/3.3 kV | 3×95 + 1×35 + 4×6 | 3.4 | 61.2 – 67.3 | 0.206 | 260 | 6,540 |
| MCP / MCPTJ-1.9/3.3 kV | 3×120 + 1×35 + 4×6 | 3.4 | 65.0 – 71.5 | 0.161 | 300 | 7,710 |
| MCP / MCPTJ-1.9/3.3 kV | 3×150 + 1×50 + 4×6 | 3.4 | 69.8 – 76.6 | 0.129 | 345 | 9,120 |
These are the standards this construction is designed and manufactured to (MT/T 818.2, MT/T 818.3, MT/T 818.4 and GB/T 12972).
Continuous ampacities are rated at +90 °C conductor temperature in +25 °C ambient air; apply appropriate grouping correction when multiple cables are stacked inside enclosed troughs.
Custom control core counts (such as 7 × 2.5 mm² or integrated optical fibres) can be manufactured to match specific shearer OEM pinouts.
Standards
| Standard or specification | Application |
|---|---|
| MT/T 818.2-2009 / GB/T 12972.2 | Coal cutter screened flexible rubber-sheathed cables rated 0.66/1.14 kV (Type MCP). |
| MT/T 818.3-2009 / GB/T 12972.3 | Coal cutter metallic-screened and monitored flexible rubber-sheathed cables rated 0.66/1.14 kV (Type MCPTJ). |
| MT/T 818.4-2009 / GB/T 12972.4 | Coal cutter metallic-screened flexible rubber-sheathed cables rated 1.9/3.3 kV (Types MCP and MCPTJ). |
| MT 386 | Flame-retardant test specification for underground mining cables. |
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
MYP & MYPT Screened Flexible Coal Mining Cable (0.38/0.66–1.9/3.3 kV)
A related cable option for a different application or duty profile.
View productMYPTJ Monitored Medium-Voltage Mining Trailing Cable (3.6/6–8.7/10 kV)
A related cable option for a different application or duty profile.
View productSHD-GC Cable 2kV-25kV Mining Power Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.